scholarly journals Influence of a prophylaxis paste on surface roughness of different composites, porcelain, enamel and dentin surfaces

2012 ◽  
Vol 06 (01) ◽  
pp. 001-008 ◽  
Author(s):  
Haktan Yurdaguven ◽  
Arzu Aykor ◽  
Emre Ozel ◽  
Hilmi Sabuncu ◽  
Mubin Soyman

ABSTRACTObjective: To investigate the effect of a prophylaxis paste on surface roughness of different composites, enamel, dentin and porcelain surfaces.Methods: Three different composites (FiltekZ250/Group1, Filtek Supreme XT/Group2, Premise/ Group3), enamel/Group4, dentin/Group5 and porcelain/Group6 samples were used in this study. All specimens were prepared flat by SiC discs and polished with a diamond polishing paste. The surface roughness measurements were determined with a profilometer after polishing (initial surface roughness). Prophylaxis paste was applied to the samples for 12 seconds, renewing every 6 seconds. After cleaning the samples, roughness values were measured again. Data were analyzed by Kruskal Wallis and Dunn’s multiple comparison test. Wilcoxon test was performed for the comparison of the initial and final surface roughness values (P<.05). The results were evaluated within the P<.05 confidence level.Results: The mean %SMHC was:C=77.27%, CL= 72.45%, SL=78.43%, G=66.65% and P=67.95%. Comparing the %SMHC promoted by 5 soft drinks, SL = C > CL > P = G (P<.05). There was not significant correlation between %SMHC and the other variables tested for the five drinks (P>>.05)Results: The initial and final surface roughness values (μm) were determined as follows: Group1: 0.039±0.009 and 0.157±0.018, Group2: 0.023±0.005 and 0.145±0.027, Group3: 0.028±0.008 and 0.109±0.012, Group4: 0.024±0.006 and 0.071±0.015, Group5: 0.030±0.007 and 0.143±0.029, Group6: 0.024±0.006 and 0.064±0.014. Significant difference was determined between the initial and final values for all groups.Conclusions: Composite and dentin surfaces were more affected by the application of prophylaxis paste than enamel and porcelain surfaces. The prophylaxis paste increased the surface roughness of all groups, but did not reach the bacterial retention roughness rate of 0.2μm. (Eur J Dent 2012;6:1-8)

2003 ◽  
Vol 11 (4) ◽  
pp. 348-353 ◽  
Author(s):  
Leonardo Gonçalves Cunha ◽  
Roberta Caroline Bruschi Alonso ◽  
Paulo Henrique dos Santos ◽  
Mário Alexandre Coelho Sinhoreti

The aim of this study was to evaluate the surface roughness of two Ormocer-based resin composites before and after mechanical toothbrushing. The study compared the brands Admira and Definite with composites based on conventional monomer systems (Bis-GMA, Bis-EMA, UEDMA e TEGDMA), Z250 and A110. Eight samples of each material with 4mm in diameter and 2mm in height were prepared using a metallic mold. After 24 hours they were polished and examined with a profilometer for measurement of the initial surface roughness (Ra, mm) before mechanical toothbrushing (30,000 cycles). After toothbrushing, the samples were taken to the profilometer once again to check the final surface roughness. The results were submitted to ANOVA and Tukey test (5%). The Admira composite presented a higher mean of surface roughness before toothbrushing (0.132mm), with a statistical difference from the composite A110 (0.082mm). Definite (0.110mm) and Z250 (0.105mm) composites showed no differences between themselves or among the other composites. No statistical differences were observed after toothbrushing between the composites Definite (0.178mm), Z250 (0.187mm), Admira (0.181mm), and A110 (0.193mm). All composites showed a statistically significant increase in the surface roughness after toothbrushing.


2019 ◽  
Vol 44 (3) ◽  
pp. E122-E132 ◽  
Author(s):  
L St-Pierre ◽  
C Martel ◽  
H Crépeau ◽  
MA Vargas

SUMMARY Objectives: The objective of this in vitro study was to compare, with a threshold value of 200 nm, the surface roughness obtained when using 12 different polishing systems on four different composite resins (microfill, nanofill, and two nanohybrids). Methods and Materials: A total of 384 convex specimens were made using Durafill VS, Filtek Supreme Ultra, Grandio SO, and Venus Pearl. After sandblasting and finishing with a medium-grit finishing disc, initial surface roughness was measured using a surface roughness tester. Specimens were polished using 12 different polishing systems: Astropol, HiLuster Plus, D♦Fine, Diacomp, ET Illustra, Sof-Lex Wheels, Sof-Lex XT discs, Super-Snap, Enhance/Pogo, Optrapol, OneGloss and ComposiPro Brush (n=8). The final surface roughness was measured, and data were analyzed using two-way analysis of variance. Pairwise comparisons were made using protected Fisher least significant difference. Results: There were statistical differences in the final surface roughness between polishing systems and between composite resins (p&lt;0.05). The highest surface roughness was observed for all composite resins polished with OneGloss and ComposiPro Brush. Enhance/Pogo and Sof-Lex Wheels produced a mean surface roughness greater than the 200-nm threshold on Filtek Supreme Ultra, Grandio SO, and Venus Pearl. Data showed that there was an interaction between the composite resins and the polishing systems. Conclusions: A single polishing system does not perform equally with all composite resins. Except for Optrapol, multi-step polishing systems performed generally better than one-step systems. Excluding Enhance/Pogo, diamond-impregnated polishers led to lower surface roughness. Durafill VS, a microfill composite resin, may be polished more predictably with different polishers.


2007 ◽  
Vol 77 (4) ◽  
pp. 723-728 ◽  
Author(s):  
YŞinasi Saraç ◽  
Selma Elekdag-Turk ◽  
Duygu Saraç ◽  
Tamer Turk

Abstract Objective: To investigate the effects of three surface conditioning methods on shear bond strength (SBS) and on surface roughness (Ra) of a feldspathic ceramic, and to compare the efficiency of three polishing techniques. Materials and Methods: A total of 106 feldspathic specimens were used. Thirty specimens were divided into three groups according to the surface conditioning methods: air-particle abrasion (APA) with 25-μm aluminum trioxide (Al2O3) (group A); hydrofluoric acid (HFA) (group H); APA and HFA (group AH). Metal brackets were bonded and subjected to SBS testing. Sixty-three specimens were divided into three groups according to the surface conditioning method. Ra was evaluated profilometrically. Then, each group was divided into three subgroups according to the polishing technique, ie, adjustment kit, diamond polishing paste, adjustment kit + diamond polishing paste. Following polishing, the second Ra values were obtained. Results: The lowest SBS was obtained for group H. This value was significantly different from the values of groups A and AH (P &lt; .05). The lowest Ra value was observed for group H (P &lt; .001). There was no significant difference between groups A and AH (P &gt; .05). No significant differences between the subgroups in which a polishing paste was used were observed (P &gt; .05). There was no significant difference between the adjustment kit and the adjustment kit + a diamond polishing paste (P &gt; .05). Conclusion: APA or APA + HFA created rougher porcelain surfaces than HFA alone. Both adjustment kit use and the adjustment kit + polishing paste application were effective to smooth the porcelain, but one was not found superior to the other.


2017 ◽  
Vol 6 (1) ◽  
pp. 1
Author(s):  
Astrid Yudith

Surface roughness is one of the important properties to determine the aesthetic and long-term durability of a dental restoration materials such as glass ionomer cements. In the oral cavity, the intervention of food, drink or other materials such as mouthwash can affect the properties of restorative materials. The aim of this study was to evaluate the effect of alcohol containing mouthwash to the surface roughness of conventional glass ionomer cement. This was an experimental laboratory study with time-series design. Samples were conventional glass ionomer cement (Fuji IX, GC, Japan) in disk shaped with 10 mm in diameter and 2 mm thick. Totally 10 samples were made and measured the initial surface roughness. Then the samples were stored in the alcohol containing mouthwash (Listerine® Cool Mint, Johnson & Johnson, Indonesia) for 30 seconds and measured the surface roughness again. The treatment and surface roughness measurements of samples is repeated up to 2 times for data 60 and 90 seconds. Roughness measurements made using profilometer tester (Mitutoyo, Japan). Data were analyzed by one-way ANOVA (p=0,05) post hoc LSD. The results showed the average value of surface roughness of glass ionomer cements early, after soaking 30, 60, and 90 seconds of 0.56 ± 0.11 µm, 0.71 µm ± 0.23, 0.96 ± 0.16 µm and 1.02 ± 0.13 µm. Data analysis shows the difference in surface roughness values   were significantly (p <0.05) between groups immersion and significant difference was found between groups of 30 seconds to 60 seconds and a group of 60 seconds to 90 seconds. The conclusion that there  is influence of alcoholic mouthwash to the surface roughness  of glass ionomer cement and the longer the soaking time with a mouthwash that contains alcohol, the surface roughness of glass ionomer cement will increase.


2019 ◽  
Vol 11 (1) ◽  
pp. 12-15
Author(s):  
Asli Topaloglu-Ak ◽  
Dilara Çayırgan ◽  
Melisa Uslu

Aim: To compare the effect of mylar strip and glycerin topical application on the surface roughness of composite, compomer, and carbomer during polymerization. Materials and Method: Each of 45 disc-shaped specimens of Z250, Dyract, Carbomer, were prepared according to manufacturer’s instructions and molded in silicone rubber molds by one operator (5 mm diameter × 2 mm thickness; n = 135). Each restorative group was divided into 3 groups as oxygen group (control), mylar strip, and glycerin group (n = 15). In the control group, specimens were light cured in the open air for 40 s, whereas in the test groups they were covered either with a mylar strip or a drop of glycerin solution and cured for 40 s. Glycerin was rinsed off before polishing. Sof-Lex discs were used for polishing before the surface roughness measurements by a profilometer. The obtained data were statistically analyzed using two-way analysis of variance at a confidence level of 95% ( P < .05). Results: The mean surface roughness values of composite, compomer, and carbomer polymerized in air, through mylar strip and glycerin showed no statistically significant difference ( P > .05). Conclusion: Mylar strip and glycerin application did not affect the surface roughness of the composite, compomer, and carbomer. Polishing may mask the effect of different curing conditions.


1993 ◽  
Vol 69 (01) ◽  
pp. 035-040 ◽  
Author(s):  
A M H P van den Besselaar ◽  
R M Bertina

SummaryFour thromboplastin reagents were tested by 18 laboratories in Europe, North-America, and Australasia, according to a detailed protocol. One thromboplastin was the International Reference Preparation for ox brain thromboplastin combined with adsorbed bovine plasma (coded OBT/79), and the second was a certified reference material for rabbit brain thromboplastin, plain (coded CRM 149R). The other two thromboplastin reagents were another rabbit plain brain thromboplastin (RP) with a lower ISI than CRM 149R and a rabbit brain thromboplastin combined with adsorbed bovine plasma (RC). Calibration of the latter two reagents was performed according to methods recommended by the World Health Organization (W. H. O.).The purpose of this study was to answer the following questions: 1) Is the calibration of the RC reagent more precise against the bovine/combined (OBT/79) than against the rabbit/plain reagent (CRM 149R)? 2) Is the precision of calibration influenced by the magnitude of the International Sensitivity Index (ISI)?The lowest inter-laboratory variation of ISI was observed in the calibration of the rabbit/plain reagent (RP) against the other rabbit/plain reagent (CRM 149R) (CV 1.6%). The highest interlaboratory variation was obtained in the calibration of rabbit/plain (RP) against bovine/combined (OBT/79) (CV 5.1%). In the calibration of the rabbit/combined (RC) reagent, there was no difference in precision between OBT/79 (CV 4.3%) and CRM 149R (CV 4.2%). Furthermore, there was no significant difference in the precision of the ISI of RC obtained with CRM 149R (ISI = 1.343) and the rabbit/plain (RP) reagent with ISI = 1.14. In conclusion, the calibration of RC could be performed with similar precision with either OBT/79 or CRM 149R, or RP.The mean ISI values calculated with OBT/79 and CRM 149R were practically identical, indicating that there is no bias in the ISI of these reference preparations and that these reference preparations have been stable since their original calibration studies in 1979 and 1987, respectively.International Normalized Ratio (INR) equivalents were calculated for a lyophilized control plasma derived from patients treated with oral anticoagulants. There were small but significant differences in the mean INR equivalents between the bovine and rabbit thromboplastins. There were no differences in the interlaboratory variation of the INR equivalents, when the four thromboplastins were compared.


2021 ◽  
Vol 10 (12) ◽  
pp. 2637
Author(s):  
Mª. Ángeles del Buey-Sayas ◽  
Elena Lanchares-Sancho ◽  
Pilar Campins-Falcó ◽  
María Dolores Pinazo-Durán ◽  
Cristina Peris-Martínez

Purpose: To evaluate and compare corneal hysteresis (CH), corneal resistance factor (CRF), and central corneal thickness (CCT), measurements were taken between a healthy population (controls), patients diagnosed with glaucoma (DG), and glaucoma suspect patients due to ocular hypertension (OHT), family history of glaucoma (FHG), or glaucoma-like optic discs (GLD). Additionally, Goldmann-correlated intraocular pressure (IOPg) and corneal-compensated IOP (IOPcc) were compared between the different groups of patients. Methods: In this prospective analytical-observational study, a total of 1065 patients (one eye of each) were recruited to undergo Ocular Response Analyzer (ORA) testing, ultrasound pachymetry, and clinical examination. Corneal biomechanical parameters (CH, CRF), CCT, IOPg, and IOPcc were measured in the control group (n = 574) and the other groups: DG (n = 147), FHG (n = 78), GLD (n = 90), and OHT (n = 176). We performed a variance analysis (ANOVA) for all the dependent variables according to the different diagnostic categories with multiple comparisons to identify the differences between the diagnostic categories, deeming p < 0.05 as statistically significant. Results: The mean CH in the DG group (9.69 mmHg) was significantly lower compared to controls (10.75 mmHg; mean difference 1.05, p < 0.001), FHG (10.70 mmHg; mean difference 1.00, p < 0.05), GLD (10.63 mmHg; mean difference 0.93, p < 0.05) and OHT (10.54 mmHg; mean difference 0.84, p < 0.05). No glaucoma suspects (FHG, GLD, OHT groups) presented significant differences between themselves and the control group (p = 1.00). No statistically significant differences were found in the mean CRF between DG (11.18 mmHg) and the control group (10.75 mmHg; mean difference 0.42, p = 0.40). The FHG and OHT groups showed significantly higher mean CRF values (12.32 and 12.41 mmHg, respectively) than the DG group (11.18 mmHg), with mean differences of 1.13 (p < 0.05) and 1.22 (p < 0.001), respectively. No statistically significant differences were found in CCT in the analysis between DG (562 μ) and the other groups (control = 556 μ, FHG = 576 μ, GLD = 569 μ, OHT = 570 μ). The means of IOPg and IOPcc values were higher in the DG patient and suspect groups than in the control group, with statistically significant differences in all groups (p < 0.001). Conclusion: This study presents corneal biomechanical values (CH, CRF), CCT, IOPg, and IOPcc for diagnosed glaucoma patients, three suspected glaucoma groups, and a healthy population, using the ORA. Mean CH values were markedly lower in the DG group (diagnosed with glaucoma damage) compared to the other groups. No significant difference was found in CCT between the DG and control groups. Unexpectedly, CRF showed higher values in all groups than in the control group, but the difference was only statistically significant in the suspect groups (FHG, GLD, and OHT), not in the DG group.


1995 ◽  
Vol 35 (4) ◽  
pp. 461 ◽  
Author(s):  
DL Hopkins ◽  
PJ Holst ◽  
DG Hall

Objective and subjective tests for quality were performed on the meat from 40 cryptorchid second-cross lambs fed lucerne only (L; n = 8), lucerne plus an oat grain supplement ad libitum (LO; n = lo), lucerne plus wilted lucerne silage ad libitum (LS; n = 11), or an oat-lupin grain (3:1) supplement at 90% of ad libitum while grazing dry summer annual pasture (OL; n = 11). All carcasses complied with the Elite lamb specification of weight >22 kg and GR measurement 6-15 mm. There was no significant difference between groups for hot carcass weight, the mean (� s.e) values being 25.1 0.43, 25.2 � 0.36,25.2 � 0.38, and 25.3 � 0.36 kg for L, LS, LO, and OL groups, respectively. When the GR and fat depth over the eye muscle at the 12th rib were adjusted to a common carcass weight of 25.2 kg there was no significant difference between groups. There was no significant difference between groups for pH, or the colour values a*, b*, and L* of the M. longissimus thoracis et lumborum (a* is relative redness, b* relative yellowness, and L* relative lightness). The shear force values for the loin muscle were significantly (P<0.05) greater for lambs from group OL than for those from group LO. Cooking loss for the loin muscle was significantly (P<0.05) greater for OL lambs than all other groups. A comparison of the mean values for aroma and flavour showed the lambs from group OL produced meat that was considered significantly (P<0.05) less desirable for these characteristics, with other groups being similar. Meat from OL-fed lambs was considered oilier and less meaty than meat from lambs fed the other diets. There was a significant (P<0.05) difference in absolute scores between panellists, but their ranking was not affected and there was no panellist x sample interaction. Because many producers use grain supplements such as oats and lupins for finishing lambs on dry forages, further study is recommended that focuses on the interaction between supplement and the base forage.


2016 ◽  
Vol 10 (02) ◽  
pp. 170-175 ◽  
Author(s):  
Gabriela Migliorin da Rosa ◽  
Luciana Mendonça da Silva ◽  
Márcio de Menezes ◽  
Hugo Felipe do Vale ◽  
Diego Ferreira Regalado ◽  
...  

ABSTRACT Objectives: The present study verified the influence of whitening dentifrices on the surface roughness of a nanohybrid composite resin. Materials and Methods: Thirty-two specimens were prepared with Filtek™ Z350 XT (3M/ESPE) and randomly divided into four groups (n = 08) that were subjected to brushing simulation equivalent to the period of 1 month. The groups assessed were a control group with distilled water (G1), Colgate Total 12 Professional Clean (G2), Sensodyne Extra Whitener Extra Fresh (G3), and Colgate Luminous White (G4). A sequence of 90 cycles was performed for all the samples. The initial roughness of each group was analyzed by the Surface Roughness Tester (TR 200-TIME Group Inc., CA, USA). After the brushing period, the final roughness was measured, and the results were statistically analyzed using nonparametric Kruskal–Wallis and Dunn tests for intergroup roughness comparison in the time factor. For intragroup and “Δ Final − Initial” comparisons, the Wilcoxon test and (one-way) ANOVA were, respectively, performed (α = 0.05). Results: The roughness mean values before and after brushing showed no statistically significant difference when the different dentifrices were used. None of the dentifrices analyzed increased significantly the nanohybrid composite resin surface roughness in a 1 month of tooth brushing simulation. Conclusions: These results suggest that no hazardous effect on the roughness of nanohybrid composite resin can be expected when whitening dentifrices are used for a short period. Similar studies should be conducted to analyze other esthetic composite materials.


2017 ◽  
Vol 40 (2) ◽  
pp. 82-87 ◽  
Author(s):  
Faika Y. Abdelmegid ◽  
Fouad S. Salama ◽  
Waleed M. Al-Mutairi ◽  
Saud K. Al-Mutairi ◽  
Sultan O. Baghazal

Introduction The aim of this in vitro study was to assess and compare the effect of different intermediary bases on microleakage between tooth and a nanocomposite interface in Class II box cavities in primary teeth. Methods Standard Class II box cavities were prepared in 52 primary molars and randomly divided into 9 groups according to the intermediary base used (Multicore Flow, Fuji II LC, SDR, Smart Dentin Replacement, and Biodentine). All specimens were subjected to thermocycling and prepared for microleakage testing and evaluation. Results There was significant difference in the mean ranks of microleakage between the 9 groups, which was observed in the gingival side (p<0.0001) and the occlusal side (p<0.0001). The mean ranks microleakage was significantly higher with experimental SDR, experimental Multicore Flow, and positive control materials when compared with the other 6 groups. The microleakage mean ranks were statistically significantly lower in experimental Fuji II LC, experimental Biodentine, and all negative control groups when compared with the other 3 groups. Conclusions Microleakage is affected by the application of intermediate material. Experimental Biodentine and Fuji II LC showed the lowest microleakage while experimental SDR and experimental Multicore Flow showed the highest microleakage.


Sign in / Sign up

Export Citation Format

Share Document