Characterization and Failure Analysis of 3D Integrated Systems using a novel plasma-FIB system

Author(s):  
Laurens Kwakman ◽  
German Franz ◽  
Maaike Margrete Visser Taklo ◽  
Armin Klumpp ◽  
Peter Ramm ◽  
...  
2011 ◽  
Vol 2011 (DPC) ◽  
pp. 002071-002111
Author(s):  
Peter Ramm ◽  
Armin Klumpp ◽  
German Franz ◽  
Laurens Kwakman

Today 3D integration based on through silicon vias (TSV) is a well-accepted approach to overcome the performance bottleneck and simultaneously shrink the form factor. According to the ITRS road map [1] there is a variety of reasons for application of 3D integration, such as miniaturization, improved circuit performance, lower power consumption and heterogeneous integration. World-wide, several full 3D process flows have been demonstrated. However, there is a strong demand for considering the behaviour and reliability of 3D-integrated systems [2]. Explicitly, the impact of 3D processes on the system, e.g. thermo-mechanical stresses, has to be evaluated before the implementation to production lines. A test chip for reliability evaluation of 3D TSV technologies was designed and fabricated by Fraunhofer EMFT. The 3D-integrated reliability test chip is a 3-level-stack with TSVs through a middle (2nd) device layer to connect structures on the bottom (1st) level with the top (3rd) level device. The layout is modular, so you can test basic assembly processing with the combination of level 1 with level 2 only and the influence of additional processing when adding level 3. For reliability testing, temperature cycling following the JEDEC standard was performed from −55 C ° to +150 °C (at a soak time of 5 minutes). Additionally, analysis was done by cross sectioning and reversed engineering. The 3D-integrated test chips were fabricated by application of Fraunhofer EMFT's TSV SLID technology. The applied 3D TSV process is based on intermetallic compound (IMC) bonding and TSV formation before stacking [3]. Reliability issues related to thermo-mechanical stress caused by the 3D integration process have to be considered. Failures of 3D integrated systems caused by TSV formation and the permanent bonding process were analysed by a novel high rate milling Focussed Ion Beam equipment. Figure 1 schematically shows the application of the novel FIB analysis technique for the areas of interest (IMC bond, TSV cross sections). Compared to classical FIB systems, the new equipment allows to remove material significantly faster while maintaining good resolution at low beam currents, important for the subsequent analysis. Cross sections of the 3-layer stack are shown in Figure 2. The merits of the novel plasma FIB and the resulting failure analysis will be discussed in detail.


2019 ◽  
Vol 42 ◽  
Author(s):  
J. Alfredo Blakeley-Ruiz ◽  
Carlee S. McClintock ◽  
Ralph Lydic ◽  
Helen A. Baghdoyan ◽  
James J. Choo ◽  
...  

Abstract The Hooks et al. review of microbiota-gut-brain (MGB) literature provides a constructive criticism of the general approaches encompassing MGB research. This commentary extends their review by: (a) highlighting capabilities of advanced systems-biology “-omics” techniques for microbiome research and (b) recommending that combining these high-resolution techniques with intervention-based experimental design may be the path forward for future MGB research.


Author(s):  
John R. Devaney

Occasionally in history, an event may occur which has a profound influence on a technology. Such an event occurred when the scanning electron microscope became commercially available to industry in the mid 60's. Semiconductors were being increasingly used in high-reliability space and military applications both because of their small volume but, also, because of their inherent reliability. However, they did fail, both early in life and sometimes in middle or old age. Why they failed and how to prevent failure or prolong “useful life” was a worry which resulted in a blossoming of sophisticated failure analysis laboratories across the country. By 1966, the ability to build small structure integrated circuits was forging well ahead of techniques available to dissect and analyze these same failures. The arrival of the scanning electron microscope gave these analysts a new insight into failure mechanisms.


Author(s):  
Evelyn R. Ackerman ◽  
Gary D. Burnett

Advancements in state of the art high density Head/Disk retrieval systems has increased the demand for sophisticated failure analysis methods. From 1968 to 1974 the emphasis was on the number of tracks per inch. (TPI) ranging from 100 to 400 as summarized in Table 1. This emphasis shifted with the increase in densities to include the number of bits per inch (BPI). A bit is formed by magnetizing the Fe203 particles of the media in one direction and allowing magnetic heads to recognize specific data patterns. From 1977 to 1986 the tracks per inch increased from 470 to 1400 corresponding to an increase from 6300 to 10,800 bits per inch respectively. Due to the reduction in the bit and track sizes, build and operating environments of systems have become critical factors in media reliability.Using the Ferrofluid pattern developing technique, the scanning electron microscope can be a valuable diagnostic tool in the examination of failure sites on disks.


Sign in / Sign up

Export Citation Format

Share Document