Enhanced confinement in diverted negative-triangularity L-mode plasmas in TCV

Author(s):  
Stefano Coda ◽  
Antoine Merle ◽  
Olivier Sauter ◽  
Laurie Porte ◽  
Filippo Bagnato ◽  
...  

Abstract The favourable confinement properties of negative-triangularity (NT) tokamak configurations were discovered in the TCV tokamak in the late 1990’s and were documented over the two following decades, through investigations of predominantly electron-heated plasmas in limited topologies. The most recent experimental campaign in TCV has marked a leap forward, characterized by the development of a variety of diverted NT shapes that are robustly stable with basic Ohmic heating. The application of auxiliary heating, directed now at both electrons and ions (using electron-cyclotron resonance heating as well as neutral-beam injection), has enabled the achievement of record performances for L-mode plasmas, with normalized β values reaching 2.8 transiently (as well as 2 in steady state, but reverting to a limited configuration) and with comparable ion and electron temperatures. The systematic confinement enhancement with NT is confirmed in these experiments. The L-mode existence space is broader than at positive triangularity, with only sporadic transitions to Hmode observed up to 1.4-MW heating power regardless of the magnetic-field-gradient direction relative to the X-point. These experiments are planned to be continued with even higher power following a heating-source upgrade.

1992 ◽  
Vol 258 ◽  
Author(s):  
F.S. Pool ◽  
J.M. Essick ◽  
Y.H. Shing ◽  
R.T. Mather

ABSTRACTThe magnetic field profile of an electron cyclotron resonance (ECR) microwave plasma was systematically altered to determine subsequent effects on a-Si:H film quality. Films of a-Si:H were deposited at pressures of 0.7 mTorr and 5 mTorr with a H2/SiH4 ratio of approximately three. The mobility gap density of states ND, deposition rate and light to dark conductivity were determined for the a-Si:H films. This data was correlated to the magnetic field profile of the plasma, which was characterized by Langmuir probe measurements of the ion current density. By variation of the magnetic field profile ND could be altered by more than an order of magnitude, from 1×1016 to 1×1017 at 0.7 mTorr and 1×1016 to 5×1017 at 5 mTorr. Two deposition regimes were found to occur for the conditions of this study. Highly divergent magnetic fields resulted in poor quality a-Si:H, while for magnetic field profiles defining a more highly confined plasma, the a-Si:H was of device quality and relatively independent of the magnetic field configuration.


2011 ◽  
Vol 268-270 ◽  
pp. 1755-1758
Author(s):  
Xiao Ping Luo ◽  
Peng Ying Du ◽  
Ying Qi Ge

The negative high-voltage power supply of Electron Cyclotron Resonance Heating (ECRH) is a nonlinear system with serve sensitivity and it is not well for traditional controller to meet restrict demand on stability and quick response. Based on the concept of credit a novel CMAC is designed to accelerate the convergence of traditional CMAC and also is used as an intelligent controller for the power of ECRH based on the idea on direct inverse control. Experiment results show that ICA-CMAC can control the power of ECRH well with shorter settling time and less CPU consumption thus the validity of ICA-CMAC is determined.


2021 ◽  
Author(s):  
Shengyu Shi ◽  
Jiale Chen ◽  
Clarisse Bourdelle ◽  
Xiang Jian ◽  
Tomas Odstrcil ◽  
...  

Abstract The behavior of heavy/high-Z impurity tungsten (W) in an improved high-performance fully non-inductive discharge on EAST with ITER-like divertor (ILD) is analyzed. It is found that W could be well controlled. The causes of no W accumulation are clarified by analyzing the background plasma parameters and modeling the W transport. It turns out that the electron temperature (T_e) and its gradient are usually high while the toroidal rotation and density peaking of the bulk plasma are small. In this condition, the modeled W turbulent diffusion coefficient is big enough to offset the total turbulent and neoclassical pinch, so that W density profile for zero particle flux will not be very peaked. Combining NEO and TGLF for the W transport coefficient and the impurity transport code STRAHL, not only the core W density profile is predicted but also the radiated information mainly produced by W in the experiment can be closely reconstructed. At last, the physics of controlling W accumulation by electron cyclotron resonance heating (ECRH) is illustrated considering the effects of changed T_e by ECRH on ionization balance and transport of W. It shows that the change of ionization and recombination balance by changed T_e is not enough to explain the experimental observation of W behavior, which should be attributed to the changed W transport. By comparing the W transport coefficients in two kinds of plasmas with different T_e profiles, it is shown that high T_e and its gradient play a key role to generate large turbulent diffusion through increasing the growth rate of linear instability so that W accumulation is prevented.


2005 ◽  
Vol 47 (2) ◽  
pp. 108-118 ◽  
Author(s):  
E. Westerhof ◽  
J. A. Hoekzema ◽  
G. M. D. Hogeweij ◽  
R. J. E. Jaspers ◽  
F. C. Schüller ◽  
...  

2018 ◽  
Author(s):  
Mahendran Subramanian ◽  
Arkadiusz Miaskowski ◽  
Stuart Iain Jenkins ◽  
Jenson Lim ◽  
Jon Dobson

AbstractThe manipulation of magnetic nanoparticles (MNPs) using an external magnetic field, has been demonstrated to be useful in various biomedical applications. Some techniques have evolved utilizing this non-invasive external stimulus but the scientific community widely adopts few, and there is an excellent potential for more novel methods. The primary focus of this study is on understanding the manipulation of MNPs by a time-varying static magnetic field and how this can be used, at different frequencies and displacement, to manipulate cellular function. Here we explore, using numerical modeling, the physical mechanism which underlies this kind of manipulation, and we discuss potential improvements which would enhance such manipulation with its use in biomedical applications, i.e., increasing the MNP response by improving the field parameters. From our observations and other related studies, we infer that such manipulation depends mostly on the magnetic field gradient, the magnetic susceptibility and size of the MNPs, the magnet array oscillating frequency, the viscosity of the medium surrounding MNPs, and the distance between the magnetic field source and the MNPs. Additionally, we demonstrate cytotoxicity in neuroblastoma (SH-SY5Y) and hepatocellular carcinoma (HepG2) cells in vitro. This was induced by incubation with MNPs, followed by exposure to a magnetic field gradient, physically oscillating at various frequencies and displacement amplitudes. Even though this technique reliably produces MNP endocytosis and/or cytotoxicity, a better biophysical understanding is required to develop the mechanism used for this precision manipulation of MNPs, in vitro.


2019 ◽  
Vol 13 (4) ◽  
pp. 221-225
Author(s):  
Wojciech Horak ◽  
Marcin Szczęch ◽  
Bogdan Sapiński

Abstract This article deals with experimental testing of magnetorheological fluid (MRF) behaviour in the oscillatory squeeze mode. The authors investigate and analyse the influence of excitation frequency and magnetic field density level on axial force in MRFs that differ in particle volume fraction. The results show that, under certain conditions, the phenomenon of self-sealing can occur as a result of the magnetic field gradient and a vacuum in the working gap of the system.


2012 ◽  
Vol 59 (3) ◽  
pp. 154-159
Author(s):  
Djurica Grga ◽  
Marina Marjanovic ◽  
Igor Hut ◽  
Bojan Dzeletovic ◽  
Djuro Koruga

Emerging technologies and new nanoscale information have potential to transform dental practice by improving all aspects of diagnostics and therapy. Nanocharacterization allows understanding of oral diseases at molecular and cellular levels which eventually can increase the success of prevention and treatment. Opto-magnetic spectroscopy (OMS) is a promising new technique based on light-matter interaction which allows insight into the quantum state of matter. Since biomolecules and tissues are usually paramagnetic or diamagnetic materials it is possible to determine the dynamics of para-and diamagnetism at different teeth structures using that method. The topography of the surface of a sample can be obtained with a very high resolution using atomic force microscopy (AFM), which allows observation of minimal changes up to 10 nm, while magnetic force microscopy (MFM) is used to record the magnetic field gradient and its distribution over the surface of a sample. The aim of this study was to determine the possibility of AFM and MFM for the characterization of dental calculus, and a potential application of OMS for the detection of subgingival dental calculus.


Sign in / Sign up

Export Citation Format

Share Document