scholarly journals Structural stability of SARS-CoV-2 degrades with temperature

2020 ◽  
Author(s):  
A. Sharma ◽  
B. Preece ◽  
H Swann ◽  
X. Fan ◽  
R.J. McKenney ◽  
...  

AbstractSARS-CoV-2 is a novel coronavirus which has caused the COVID-19 pandemic. Other known coronaviruses show a strong pattern of seasonality, with the infection cases in humans being more prominent in winter. Although several plausible origins of such seasonal variability have been proposed, its mechanism is unclear. SARS-CoV-2 is transmitted via airborne droplets ejected from the upper respiratory tract of the infected individuals. It has been reported that SARS-CoV-2 can remain infectious for hours on surfaces. As such, the stability of viral particles both in liquid droplets as well as dried on surfaces is essential for infectivity. Here we have used atomic force microscopy to examine the structural stability of individual SARS-CoV-2 virus like particles at different temperatures. We demonstrate that even a mild temperature increase, commensurate with what is common for summer warming, leads to dramatic disruption of viral structural stability, especially when the heat is applied in the dry state. This is consistent with other existing non-mechanistic studies of viral infectivity, provides a single particle perspective on viral seasonality, and strengthens the case for a resurgence of COVID-19 in winter.Statement of Scientific SignificanceThe economic and public health impact of the COVID-19 pandemic are very significant. However scientific information needed to underpin policy decisions are limited partly due to novelty of the SARS-CoV-2 pathogen. There is therefore an urgent need for mechanistic studies of both COVID-19 disease and the SARS-CoV-2 virus. We show that individual virus particles suffer structural destabilization at relatively mild but elevated temperatures. Our nanoscale results are consistent with recent observations at larger scales. Our work strengthens the case for COVID-19 resurgence in winter.

RSC Advances ◽  
2015 ◽  
Vol 5 (1) ◽  
pp. 10-15 ◽  
Author(s):  
Yang Liu ◽  
Cheng-Lu Liang ◽  
Rui-Ying Bao ◽  
Guo-Qiang Qi ◽  
Wei Yang ◽  
...  

The stability of rGO hydrogels prepared at different temperatures was investigated. The network of rGO hydrogel formed at 40 °C showed the best structural stability, the lowest electrical resistance and highest mechanical strength.


Holzforschung ◽  
2008 ◽  
Vol 62 (3) ◽  
Author(s):  
Cihat Tascioglu ◽  
Paul Cooper ◽  
Tony Ung

Abstract Red pine (Pinus resinosa Ait.) sapwood samples treated with alkaline (amine) copper quaternary (ACQ) were conditioned at different temperatures and under wet or dry conditions to evaluate the stability of copper (Cu) to leaching and conversion of divalent copper (Cu-II) to monovalent copper (Cu-I). Significant Cu-II was reduced to Cu-I during post-treatment stabilization, especially at elevated temperatures (105°C and 120°C). The percent conversion to Cu-I was higher at lower retentions; in some cases, at low retentions and high fixation temperatures, all of the cupric Cu was reduced to Cu-I, raising the possibility of reduced activity of Cu as a biocide when high temperature conditions are used to fix ACQ treated wood. However, exposure of wood to a leaching procedure (rewetting, re-drying) generally resulted in a significant component of the Cu-I in wood being oxidized back to Cu-II. Steaming of weathered ACQ treated wood at 120°C also converted significant amounts of Cu-II to Cu-I.


Author(s):  
J. L. Brimhall ◽  
H. E. Kissinger ◽  
B. Mastel

Some information on the size and density of voids that develop in several high purity metals and alloys during irradiation with neutrons at elevated temperatures has been reported as a function of irradiation parameters. An area of particular interest is the nucleation and early growth stage of voids. It is the purpose of this paper to describe the microstructure in high purity nickel after irradiation to a very low but constant neutron exposure at three different temperatures.Annealed specimens of 99-997% pure nickel in the form of foils 75μ thick were irradiated in a capsule to a total fluence of 2.2 × 1019 n/cm2 (E > 1.0 MeV). The capsule consisted of three temperature zones maintained by heaters and monitored by thermocouples at 350, 400, and 450°C, respectively. The temperature was automatically dropped to 60°C while the reactor was down.


The analysis of the previous results of the study on concrete stress-strain behavior at elevated temperatures has been carried out. Based on the analysis, the main reasons for strength retrogression and elastic modulus reduction of concrete have been identified. Despite a significant amount of research in this area, there is a large spread in experimental data received, both as a result of compression and tension. In addition, the deformation characteristics of concrete are insufficiently studied: the coefficient of transverse deformation, the limiting relative compression deformation corresponding to the peak load and the almost complete absence of studies of complete deformation diagrams at elevated temperatures. The two testing chambers provided creating the necessary temperature conditions for conducting studies under bending compression and tension have been developed. On the basis of the obtained experimental data of physical and mechanical characteristics of concrete at different temperatures under conditions of axial compression and tensile bending, conclusions about the nature of changes in strength and deformation characteristics have been drawn. Compression tests conducted following the method of concrete deformation complete curves provided obtaining diagrams not only at normal temperature, but also at elevated temperature. Based on the experimental results, dependences of changes in prism strength and elastic modulus as well as an equation for determining the relative deformation and stresses at elevated temperatures at all stages of concrete deterioration have been suggested.


2020 ◽  
Vol 17 (12) ◽  
pp. 1458-1464
Author(s):  
Sweta Kamboj ◽  
Rohit Kamboj ◽  
Shikha Kamboj ◽  
Kumar Guarve ◽  
Rohit Dutt

Background: In the 1960s, the human coronavirus was designated, which is responsible for the upper respiratory tract disease in children. Back in 2003, mainly 5 new coronaviruses were recognized. This study directly pursues to govern knowledge, attitude and practice of viral and droplet infection isolation safeguard among the researchers during the outbreak of the COVID-19. Introduction: Coronavirus is a proteinaceous and infectious pathogen. It is an etiological agent of severe acute respiratory syndrome (SARS) and the Middle East respiratory syndrome (MERS). Coronavirus, appeared in China from the seafood and poultry market last year, which has spread in various countries, and has caused several deaths. Methods: The literature data has been taken from different search platforms like PubMed, Science Direct, Embase, Web of Science, who.int portal and complied. Results: Corona virology study will be more advanced and outstanding in recent years. COVID-19 epidemic is a threatening reminder not solely for one country but all over the universe. Conclusion: In this review article, we encapsulated the pathogenesis, geographical spread of coronavirus worldwide, also discussed the perspective of diagnosis, effective treatment, and primary recommendations by the World Health Organization, and guidelines of the government to slow down the impact of the virus are also optimistic, efficacious and obliging for the public health. However, it will take a prolonged time in the future to overcome this epidemic.


Nanomaterials ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 1885
Author(s):  
Xinyu Wu ◽  
Feng Yang ◽  
Jian Gan ◽  
Zhangqian Kong ◽  
Yan Wu

The silver particles were grown in situ on the surface of wood by the silver mirror method and modified with stearic acid to acquire a surface with superhydrophobic and antibacterial properties. Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and X-ray energy spectroscopy (XPS) were used to analyze the reaction mechanism of the modification process. Scanning electron microscopy (SEM) and contact angle tests were used to characterize the wettability and surface morphology. A coating with a micro rough structure was successfully constructed by the modification of stearic acid, which imparted superhydrophobicity and antibacterial activity to poplar wood. The stability tests were performed to discuss the stability of its hydrophobic performance. The results showed that it has good mechanical properties, acid and alkali resistance, and UV stability. The durability tests demonstrated that the coating has the function of water resistance and fouling resistance and can maintain the stability of its hydrophobic properties under different temperatures of heat treatment.


1971 ◽  
Vol 125 (4) ◽  
pp. 1009-1018 ◽  
Author(s):  
R. E. Chambers ◽  
J. R. Clamp

The stability of monosaccharides in methanolic hydrochloric acid of different strengths and at different temperatures was determined. They are generally stable for 24h in methanolic 1m- and 2m-hydrochloric acid at both 85°C and 100°C, but undergo considerable destruction in methanolic 4m- and 6m-hydrochloric acid at 100°C. Analysis of glycopeptides and oligosaccharides of known composition showed that release of carbohydrate was complete within 3h in methanolic 1m-hydrochloric acid at 85°C. Removal of methanolic hydrochloric acid by rotary evaporation resulted in considerable losses of monosaccharides, which could be prevented by prior neutralization. Methanolysis caused extensive de-N-acetylation of acetamidohexoses, so that a re-N-acetylation step is necessary in the analytical procedure. The addition of acetic anhydride for this purpose also prevented loss of internal standard by adsorption on the insoluble silver salts used in neutralization. Several trimethylsilylating agents were studied and suitable conditions are recommended. The effects on the analytical system of water and some common organic and inorganic contaminants are assessed.


2020 ◽  
Vol 2020 (1) ◽  
Author(s):  
N. H. Sweilam ◽  
S. M. Al-Mekhlafi ◽  
A. O. Albalawi ◽  
D. Baleanu

Abstract In this paper, a novel coronavirus (2019-nCov) mathematical model with modified parameters is presented. This model consists of six nonlinear fractional order differential equations. Optimal control of the suggested model is the main objective of this work. Two control variables are presented in this model to minimize the population number of infected and asymptotically infected people. Necessary optimality conditions are derived. The Grünwald–Letnikov nonstandard weighted average finite difference method is constructed for simulating the proposed optimal control system. The stability of the proposed method is proved. In order to validate the theoretical results, numerical simulations and comparative studies are given.


Author(s):  
Josep Miquel Bauça ◽  
Andrea Caballero ◽  
Carolina Gómez ◽  
Débora Martínez-Espartosa ◽  
Isabel García del Pino ◽  
...  

AbstractObjectivesThe stability of the analytes most commonly used in routine clinical practice has been the subject of intensive research, with varying and even conflicting results. Such is the case of alanine aminotransferase (ALT). The purpose of this study was to determine the stability of serum ALT according to different variables.MethodsA multicentric study was conducted in eight laboratories using serum samples with known initial catalytic concentrations of ALT within four different ranges, namely: <50 U/L (<0.83 μkat/L), 50–200 U/L (0.83–3.33 μkat/L), 200–400 U/L (3.33–6.67 μkat/L) and >400 U/L (>6.67 μkat/L). Samples were stored for seven days at two different temperatures using four experimental models and four laboratory analytical platforms. The respective stability equations were calculated by linear regression. A multivariate model was used to assess the influence of different variables.ResultsCatalytic concentrations of ALT decreased gradually over time. Temperature (−4%/day at room temperature vs. −1%/day under refrigeration) and the analytical platform had a significant impact, with Architect (Abbott) showing the greatest instability. Initial catalytic concentrations of ALT only had a slight impact on stability, whereas the experimental model had no impact at all.ConclusionsThe constant decrease in serum ALT is reduced when refrigerated. Scarcely studied variables were found to have a significant impact on ALT stability. This observation, added to a considerable inter-individual variability, makes larger studies necessary for the definition of stability equations.


Sign in / Sign up

Export Citation Format

Share Document