scholarly journals Now you see it, now you don't: optimal parameters for interslice stimulation in concurrent TMS-fMRI

2021 ◽  
Author(s):  
Catriona L Scrivener ◽  
Jade B Jackson ◽  
Marta Morgado Correia ◽  
Marius Mada ◽  
Alexandra Woolgar

The powerful combination of transcranial magnetic stimulation (TMS) concurrent with functional magnetic resonance imaging (fMRI) provides rare insights into the causal relationships between brain activity and behaviour. Despite a recent resurgence in popularity, TMS-fMRI remains technically challenging. Here we examined the feasibility of applying TMS during short gaps between fMRI slices to avoid incurring artefacts in the fMRI data. We quantified signal dropout and changes in temporal signal-to-noise ratio (tSNR) for TMS pulses presented at timepoints from 100ms before to 100ms after slice onset. Up to 3 pulses were delivered per volume using MagVenture's MR-compatible TMS coil. We used a spherical phantom, two 7-channel TMS-dedicated surface coils, and a multiband (MB) sequence (factor=2) with interslice gaps of 100ms and 40ms, on a Siemens 3T Prisma-fit scanner. For comparison we repeated a subset of parameters with a more standard single-channel TxRx (birdcage) coil, and with a human participant and surface coil set up. We found that, even at 100% stimulator output, pulses applied at least -40ms/+50ms from the onset of slice readout avoid incurring artifacts. This was the case for all three setups. Thus, an interslice protocol can be achieved with a frequency of up to ~10 Hz, using a standard EPI sequence (slice acquisition time: 62.5ms, interslice gap: 40ms). Faster stimulation frequencies would require shorter slice acquisition times, for example using in-plane acceleration. Interslice TMS-fMRI protocols provide a promising avenue for retaining flexible timing of stimulus delivery without incurring TMS artifacts.

2021 ◽  
pp. 1-12
Author(s):  
Lin Wu ◽  
Tian He ◽  
Jie Yu ◽  
Hang Liu ◽  
Shuang Zhang ◽  
...  

BACKGROUND: Addressing intensity inhomogeneity is critical in magnetic resonance imaging (MRI) because associated errors can adversely affect post-processing and quantitative analysis of images (i.e., segmentation, registration, etc.), as well as the accuracy of clinical diagnosis. Although several prior methods have been proposed to eliminate or correct intensity inhomogeneity, some significant disadvantages have remained, including alteration of tissue contrast, poor reliability and robustness of algorithms, and prolonged acquisition time. OBJECTIVE: In this study, we propose an intensity inhomogeneity correction method based on volume and surface coils simultaneous reception (VSSR). METHODS: The VSSR method comprises of two major steps: 1) simultaneous image acquisition from both volume and surface coils and 2) denoising of volume coil images and polynomial surface fitting of bias field. Extensive in vivo experiments were performed considering various anatomical structures, acquisition sequences, imaging resolutions, and orientations. In terms of correction performance, the proposed VSSR method was comparatively evaluated against several popular methods, including multiplicative intrinsic component optimization and improved nonparametric nonuniform intensity normalization bias correction methods. RESULTS: Experimental results show that VSSR is more robust and reliable and does not require prolonged acquisition time with the volume coil. CONCLUSION: The VSSR may be considered suitable for general implementation.


2019 ◽  
Vol 6 (2) ◽  
pp. 138-153
Author(s):  
Aasrith Ganti ◽  
Jenshan Lin ◽  
Tracy Wynn ◽  
Timothy Ortiz

AbstractRadiofrequency surface coils used as receivers in magnetic resonance imaging (MRI) rely on cables for communication and power from the MRI system. Complex surface coil arrays are being designed for improving acquisition speed and signal-to-noise ratio. This, in-turn makes the cables bulky, expensive, and the currents induced on cables by time-varying magnetic fields of the MRI system may cause patient harm. Though wireless power transfer (WPT) can eliminate cables and make surface coils safer, MRI poses a challenging electromagnetic environment for WPT antennas because the antennas made using long conductors interact with the static and dynamic fields of the MRI system. This paper analyses the electromagnetic compatibility of WPT antennas and reveals that commercially available antennas are not compatible with MRI systems, presenting a safety risk for patients. Even when the risk is minimized, the antennas couple with surface coils leading to misdiagnosis. This paper presents an approach to eliminate safety risks and minimize coupling using a filter named “floating filter.” A WPT antenna without a filter has a distortion of 27%, and floating filters reduce the distortion to 2.3%. Secondly, the floating filter does not affect the power transfer efficiency, and the transfer efficiency of 60% is measured with and without filters.


Author(s):  
G. Botton ◽  
G. L’Espérance ◽  
M.D. Ball ◽  
C.E. Gallerneault

The recently developed parallel electron energy loss spectrometers (PEELS) have led to a significant reduction in spectrum acquisition time making EELS more useful in many applications in material science. Dwell times as short as 50 msec per spectrum with a PEELS coupled to a scanning transmission electron microscope (STEM), can make quantitative EEL images accessible. These images would present distribution of elements with the high spatial resolution inherent to EELS. The aim of this paper is to briefly investigate the effect of acquisition time per pixel on the signal to noise ratio (SNR), the effect of thickness variation and crystallography and finally the energy stability of spectra when acquired in the scanning mode during long periods of time.The configuration of the imaging system is the following: a Gatan PEELS is coupled to a CM30 (TEM/STEM) electron microscope, the control of the spectrometer and microscope is performed through a LINK AN10-85S MCA which is interfaced to a IBM RT 125 (running under AIX) via a DR11W line.


Author(s):  
D. C. Joy ◽  
R. D. Bunn

The information available from an SEM image is limited both by the inherent signal to noise ratio that characterizes the image and as a result of the transformations that it may undergo as it is passed through the amplifying circuits of the instrument. In applications such as Critical Dimension Metrology it is necessary to be able to quantify these limitations in order to be able to assess the likely precision of any measurement made with the microscope.The information capacity of an SEM signal, defined as the minimum number of bits needed to encode the output signal, depends on the signal to noise ratio of the image - which in turn depends on the probe size and source brightness and acquisition time per pixel - and on the efficiency of the specimen in producing the signal that is being observed. A detailed analysis of the secondary electron case shows that the information capacity C (bits/pixel) of the SEM signal channel could be written as :


Author(s):  
Arjan Mels ◽  
Frank Zachariasse

Abstract Although RIL, SDL and LADA are slightly different, the main operating principle is the same and the theory for defect localization presented in this paper is applicable to all three methods. Throughout this paper the authors refer to LADA, as all experimental results in this paper were obtained with a 1064nm laser on defect free circuits. This paper first defines mathematically what 'signal strength' actually means in LADA and then demonstrates a statistical model of the LADA situation that explains the optimal conditions for signal collection and the parameters involved. The model is tested against experimental data and is also used to optimise the acquisition time. Through this model, equations were derived for the acquisition time needed to discern a LADA response from the background noise. The model offers a quantitative tool to estimate the feasibility of a given LADA measurement and a guide to optimising the required experimental set-up.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Richard J. Smith ◽  
Fernando Pérez-Cota ◽  
Leonel Marques ◽  
Matt Clark

AbstractBrillouin light scattering (BLS) is an emerging method for cell imaging and characterisation. It allows elasticity-related contrast, optical resolution and label-free operation. Phonon microscopy detects BLS from laser generated coherent phonon fields to offer an attractive route for imaging since, at GHz frequencies, the phonon wavelength is sub-optical. Using phonon fields to image single cells is challenging as the signal to noise ratio and acquisition time are often poor. However, recent advances in the instrumentation have enabled imaging of fixed and living cells. This work presents the first experimental characterisation of phonon-based axial resolution provided by the response to a sharp edge. The obtained axial resolution is up to 10 times higher than that of the optical system used to take the measurements. Validation of the results are obtained with various polymer objects, which are in good agreement with those obtained using atomic force microscopy. Edge localisation, and hence profilometry, of a phantom boundary is measured with accuracy and precision of approximately 60 nm and 100 nm respectively. Finally, 3D imaging of fixed cells in culture medium is demonstrated.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Amara Khan ◽  
Andrea Markus ◽  
Thomas Rittmann ◽  
Jonas Albers ◽  
Frauke Alves ◽  
...  

AbstractX-ray based lung function (XLF) as a planar method uses dramatically less X-ray dose than computed tomography (CT) but so far lacked the ability to relate its parameters to pulmonary air volume. The purpose of this study was to calibrate the functional constituents of XLF that are biomedically decipherable and directly comparable to that of micro-CT and whole-body plethysmography (WBP). Here, we developed a unique set-up for simultaneous assessment of lung function and volume using XLF, micro-CT and WBP on healthy mice. Our results reveal a strong correlation of lung volumes obtained from radiographic XLF and micro-CT and demonstrate that XLF is superior to WBP in sensitivity and precision to assess lung volumes. Importantly, XLF measurement uses only a fraction of the radiation dose and acquisition time required for CT. Therefore, the redefined XLF approach is a promising tool for preclinical longitudinal studies with a substantial potential of clinical translation.


2018 ◽  
Vol 170 ◽  
pp. 09005 ◽  
Author(s):  
M.-L. Gallin-Martel ◽  
L. Abbassi ◽  
A. Bes ◽  
G. Bosson ◽  
J. Collot ◽  
...  

The MoniDiam project is part of the French national collaboration CLaRyS (Contrôle en Ligne de l’hAdronthérapie par RaYonnements Secondaires) for on-line monitoring of hadron therapy. It relies on the imaging of nuclear reaction products that is related to the ion range. The goal here is to provide large area beam detectors with a high detection efficiency for carbon or proton beams giving time and position measurement at 100 MHz count rates (beam tagging hodoscope). High radiation hardness and intrinsic electronic properties make diamonds reliable and very fast detectors with a good signal to noise ratio. Commercial Chemical Vapor Deposited (CVD) poly-crystalline, heteroepitaxial and monocrystalline diamonds were studied. Their applicability as a particle detector was investigated using α and β radioactive sources, 95 MeV/u carbon ion beams at GANIL and 8.5 keV X-ray photon bunches from ESRF. This facility offers the unique capability of providing a focused (~1 μm) beam in bunches of 100 ps duration, with an almost uniform energy deposition in the irradiated detector volume, therefore mimicking the interaction of single ions. A signal rise time resolution ranging from 20 to 90 ps rms and an energy resolution of 7 to 9% were measured using diamonds with aluminum disk shaped surface metallization. This enabled us to conclude that polycrystalline CVD diamond detectors are good candidates for our beam tagging hodoscope development. Recently, double-side stripped metallized diamonds were tested using the XBIC (X Rays Beam Induced Current) set-up of the ID21 beamline at ESRF which permits us to evaluate the capability of diamond to be used as position sensitive detector. The final detector will consist in a mosaic arrangement of double-side stripped diamond sensors read out by a dedicated fast-integrated electronics of several hundreds of channels.


2001 ◽  
Vol 685 ◽  
Author(s):  
M. Fernandes ◽  
Yu. Vygranenko ◽  
J. Martins ◽  
M. Vieira

AbstractWe suggest to enhance the performance of image acquisition systems based on large area amorphous silicon based sensors by optimizing the readout parameters such as the intensity and cross-section of scanner beam, acquisition time and bias conditions. The main output device characteristics as image responsivity, signal to noise ratio and spatial resolution were analyzed in open circuit, short circuit and photodiode modes. The result show that the highest signal to noise ratio and best dark to bright ratio can be achieved in short circuit mode.It was shown that the sensor resolution is related to the basic device parameters and, in practice, limited by the acquisition time and scanning beam properties. The scanning beam spot size limits the resolution due to the overlapping of dark and illuminated zones leading to a blurring effect on the final image and a consequent degradation in the resolution.