scholarly journals Analytical performances of the COVISTIX and Panbio antigen rapid tests for SARS-CoV-2 detection in an unselected population (all commers)

Author(s):  
Francisco Garcia-Cardenas ◽  
Alba Franco ◽  
Ricardo Cortes ◽  
Jenny Bertin ◽  
Rafael Valdez ◽  
...  

Importance: A steady increase in acute respiratory syndrome coronavirus 2 (SARS-CoV-2) cases worldwide is causing some regions of the world to withstand a third or even fourth wave of contagion. Swift detection of SARS-CoV-2 infection is paramount for the containment of cases, prevention of sustained contagion; and most importantly, for the reduction of mortality. Objective: To evaluate the performance and validity of the COVISTIXTM rapid antigen test, for the detection of SARS-CoV-2 in an unselected population and compare it to PanbioTM rapid antigen test and RT-PCR. Design: This is comparative effectiveness study; samples were collected at two point-of-care facilities in Mexico City between May and August 2021. Participants: Recruited individuals were probable COVID-19 cases, either symptomatic or asymptomatic persons that were at risk of infection due to close contact to SARS-CoV-2 positive cases. Diagnostic intervention: RT-PCR was used as gold standard for detection of SARS-CoV-2 in nasal and nasopharyngeal swabs, study subjects were tested in parallel either with the COVISTIXTM or with PanbioTM rapid antigen test. Main outcome: Diagnostic performance of the COVISTIXTM assay is adequate in all commers since its accuracy parameters were not affected in samples collected after 7 days of symptom onset, and it detected almost 65% of samples with a Ct-value between 30 and 34. Results: For the population tested with COVISTIXTM (n=783), specificity and sensitivity of the was 96.0% (CI95% 94.0-98.0) and 81% (CI95% 76.0-85.0), as for the PanbioTM (n=2202) population, was 99.0% (CI95%: 0.99-1.00) and 62% (CI%: 58.0-64.0%), respectively. Conclusions and relevance: The COVISTIXTM rapid antigen test shows a high performance in all comers, thus, this test is also adequate for testing patients who have passed the peak of viral shedding or for asymptomatic patients.

Author(s):  
Mar Masiá ◽  
Marta Fernández-González ◽  
Manuel Sánchez ◽  
Mar Carvajal ◽  
José Alberto García ◽  
...  

Abstract Background Performance of point-of-care tests in different clinical scenarios and on different samples remains undetermined. We comprehensively evaluated the performance of the nasopharyngeal Panbio COVID-19 antigen Rapid-Test-Device. Method Prospective study including consecutive patients attending three primary care centers (PCC) and an emergency department. The antigen test was performed at point-of-care in nasopharyngeal and nasal swabs, and in saliva. Positive and negative percent agreement (PPA, NPA) were calculated with the RT-PCR assay as reference standard. Results Of 913 patients included, 296 (32.3%) were asymptomatic and 690 (75.6%) came from the PCC. Nasopharyngeal swabs were collected from 913, nasal swabs from 659, and saliva from 611 patients. RT-PCR was positive in 196 (21.5%) nasopharyngeal samples (NPS). Overall PPA (95% CI) in NPS was 60.5% (53.3-67.4), and it was lower in nasal swabs (44.7%) and saliva (23.1%). Test performance in NPS was largely dependent on the cycle threshold (Ct) in RT-PCR, with PPA of 94% for Ct≤25 and 80% for Ct<30. In symptomatic patients, the PPA was 95% for Ct≤25; 85% for Ct<30, and 89% for the symptom triad of fever, cough and malaise. Performance was also dependent on age, with PPA of 100% in symptomatic patients >50 years with Ct<25. In asymptomatic patients, the PPA was 86% for Ct<25. In all cases, NPA was 100%. Conclusion The nasopharyngeal Panbio COVID-19 antigen test performed at point-of-care has a good sensitivity in symptomatic patients with Ct<30 and older age. The test was useful to identify asymptomatic patients with lower Ct values.


2020 ◽  
Author(s):  
Mar Masiá ◽  
Marta Fernández-González ◽  
Manuel Sánchez ◽  
Mar Carvajal ◽  
José Alberto García ◽  
...  

ABSTRACTBackgroundPerformance of point-of-care tests in clinical practice remains undetermined. We aimed to evaluate the performance of the nasopharyngeal Panbio COVID-19 antigen Rapid Test Device in real-life conditions in different clinical scenarios.MethodProspective study conducted in three primary care centers (PCC) and an emergency department. The antigen test was performed at point-of-care in nasopharyngeal and nasal swabs, and in saliva. Positive and negative percent agreement (PPA, NPA) were calculated with the RT-PCR assay as reference standard.ResultsOf 913 patients included, 296 (32.3%) were asymptomatic and 690 (75.6%) came from the PCC. Nasopharyngeal swabs were collected from 913, nasal swabs from 659, and saliva from 611 patients. RT-PCR was positive in 196 (21.5%) nasopharyngeal samples (NPS). Overall PPA (95% CI) in NPS was 60.5% (53.3-67.4), and it was lower in nasal swabs (44.7%) and saliva (23.1%). Test performance in NPS was largely dependent on the cycle threshold (Ct) in RT-PCR, with PPA>90% for Ct≤25 and ≥80% for Ct<30. In symptomatic patients, the PPA was 95% for Ct≤25; ≥85% for Ct<30, and 89% for the symptom triad of fever, cough and malaise. Performance was also dependent on age, with PPA of 100% in symptomatic patients >50 years with Ct<25. In asymptomatic patients, the PPA was 86% for Ct<25. In all cases, NPA was 100%.ConclusionThe nasopharyngeal Panbio COVID-19 antigen test performed at point-of-care is highly sensitive in symptomatic patients, particularly with Ct<30 and older age. The test was useful to identify asymptomatic patients with lower Ct values and therefore with contagious risk.Key pointsThe nasopharyngeal Panbio-COVID-19 antigen test performed in real-life conditions at point-of-care is highly sensitive in symptomatic patients, particularly with Ct<30 and older age. The test is useful to identify asymptomatic patients with lower Ct values and therefore with contagious risk.


2021 ◽  
Vol 8 (7) ◽  
pp. 98
Author(s):  
Ernst Emmanuel Etienne ◽  
Bharath Babu Nunna ◽  
Niladri Talukder ◽  
Yudong Wang ◽  
Eon Soo Lee

COVID-19, also known as SARS-CoV-2 is a novel, respiratory virus currently plaguing humanity. Genetically, at its core, it is a single-strand positive-sense RNA virus. It is a beta-type Coronavirus and is distinct in its structure and binding mechanism compared to other types of coronaviruses. Testing for the virus remains a challenge due to the small market available for at-home detection. Currently, there are three main types of tests for biomarker detection: viral, antigen and antibody. Reverse Transcription-Polymerase Chain Reaction (RT-PCR) remains the gold standard for viral testing. However, the lack of quantitative detection and turnaround time for results are drawbacks. This manuscript focuses on recent advances in COVID-19 detection that have lower limits of detection and faster response times than RT-PCR testing. The advancements in sensing platforms have amplified the detection levels and provided real-time results for SARS-CoV-2 spike protein detection with limits as low as 1 fg/mL in the Graphene Field Effect Transistor (FET) sensor. Additionally, using multiple biomarkers, detection levels can achieve a specificity and sensitivity level comparable to that of PCR testing. Proper biomarker selection coupled with nano sensing detection platforms are key in the widespread use of Point of Care (POC) diagnosis in COVID-19 detection.


Author(s):  
Eliseo Albert ◽  
Ignacio Torres ◽  
Felipe Bueno ◽  
Dixie Huntley ◽  
Estefanía Molla ◽  
...  

AbstractWe evaluated the Panbio™ COVID-19 AG Rapid Test Device (RAD) for the diagnosis of COVID-19 in symptomatic patients attended in primary healthcare centers (n=412). Overall specificity and sensitivity of RAD was 100% and 79.6%, respectively, taking RT-PCR as the reference. SARS-CoV-2 could not be cultured from specimens yielding RT-PCR+/RAD- results.


2021 ◽  
Vol 15 (10) ◽  
pp. 3356-3358
Author(s):  
Ambreen Fatima ◽  
Nidda Yaseen ◽  
Amna Fareed ◽  
Kashif Ali Samin ◽  
Shumaela Kanwal ◽  
...  

Background and Aim: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) rapid emergence postured significant challenges on the health system in recent years. The early detection of cases is thought to be critical in preventing this pandemic by coronavirus disease (COVID-19), especially important in the obstetrical population due to theirs numerous interactions with another parturient when hospitalized for delivery. Therefore, the present study aimed to assess the COVID antigen test performance in COVID-positive obstetrics patients. Materials and Methods: This cross-sectional study was conducted on 1296 Covid-19 asymptomatic women admitted to the Obstetrics and Gynaecology Department of Muhammad Teaching Hospital & Medical College, Peshawar and Fauji Foundation Hospital, Rawalpindi for the duration of six months from February 2021 to July 2021. Antigen-based test rapid diagnostic test (RDT) was used for screening out COVID-19 positive obstetrics patients or women through nasopharyngeal swabs. Women with negative rapid antigen test results were confirmed with RT-polymers chain reaction test of nucleic acid amplification tests (NAAT). Ethical approval and informed consent were taken from the hospital ethical committee and each individual respectively. All the known positive COVID-19 patients during admission were excluded. SPSS version 24 was used for data analysis. Results: The overall prevalence of rapid antigen-positive tested patients was 13.2% (171/1296). The prevalence of positive tested women through rapid antigen test, Nucleic Acid Amplification Test (NAAT), and RT-PCR were 27 (2.1%), 51 (3.9%), and 93 (7.2%) respectively. Of the total 1296 rapid antigen tests, 27 were positive, and the false-negative confirmed positive by NAAT was 144.Thus the sensitivity of the rapid antigen test was 15.8% and the negative predictive value was 93.7%. Of the total 298 Nucleic Acid Amplification Tested had sensitivity and negative predictive value of 89.6% and 99.06% respectively. RT-PCR was carried out on 972 patients, positive diagnosed cases were 36 while 15 were initially negative and were positive with the test was repeated. The sensitivity and negative predictive value was 71.45% and 95.8% respectively. Conclusion: Our study found that Ag-RDT plays a significant role in SARS-CoV-2 early detection in infected individuals, with high specificity and sensitivity to disease infectious stage, whether symptomatic or asymptomatic, and can be used as a decision supported tool. Early detection of COVID-19 status in women admitted for delivery could benefit neonatal protection care. Keywords: Covid-19; Rapid antigen test; RT-PCR test


2021 ◽  
Author(s):  
Jesse Gitaka ◽  
Eva Muthamia ◽  
Samuel Mbugua ◽  
Mary Mungai ◽  
Gama Bandawe ◽  
...  

Abstract Background: The COVID-19 pandemic has resulted in a need for rapid identification of infectious cases. Testing barriers have prohibited adequate screening for SARS COV2, resulting in significant delays in treatment provision and commencement of outbreak control measures. This study aimed to generate evidence on the performance and implementation characteristics of the BD Veritor rapid antigen test as compared to the gold standard test for diagnosis of SARS COV2 in Kenya. Methods: This was a field test performance evaluation in symptomatic and asymptomatic adults undergoing testing for SARS COV2. Recruited participants were classified as SARS-CoV2-positive based on the locally implemented gold standard reverse transcription polymerase chain reaction (RT-PCR) test performed on nasopharyngeal swabs. 272 antigen tests were performed with simultaneous gold standard testing, allowing us to estimate sensitivity, specificity, positive and negative predictive values for the BD Veritor rapid antigen test platform. Implementation characteristics were assessed using the Consolidated Framework for Implementation Research for feasibility, acceptability, turn-around time, and ease-of-use metrics. Results and Discussion: We enrolled 97 PCR negative symptomatic and 128 PCR negative asymptomatic, and 28 PCR positive symptomatic and 19 PCR positive asymptomatic participants. Compared to the gold standard, the sensitivity of the BD Veritor antigen test was 94% (95% confidence interval [CI] 86.6 to 100.0) while the specificity was 98% (95% confidence interval [CI] 96 to 100). The sensitivity of BD Veritor antigen test was higher among symptomatic (100%) compared to asymptomatic (84%) participants, although this difference was not statistically significant. There was also a lack of association between cycle threshold value and sensitivity of BD Veritor test. The BD Veritor test had quick turnaround time and minimal resource requirements, and laboratory personnel conducting testing felt that it was easier to use than the gold standard RT-PCR. Conclusion: The BD Veritor rapid antigen test exhibited excellent sensitivity and specificity when used to detect SARS-CoV-2 infection among both symptomatic and asymptomatic individuals in varied population settings in Kenya. It was feasible to implement and easy to use, with rapid turnaround time.


2021 ◽  
Author(s):  
Hiromichi Suzuki ◽  
Yusaku Akashi ◽  
Atsuo Ueda ◽  
Yoshihiko Kiyasu ◽  
Yuto Takeuchi ◽  
...  

Introduction: Digital immunoassays are generally regarded as superior tests for the detection of infectious disease pathogens, but there have been insufficient data concerning SARS-CoV-2 immunoassays. Methods: We prospectively evaluated a novel digital immunoassay (RapidTesta SARS-CoV-2). Two nasopharyngeal samples were simultaneously collected for antigen tests and RT-PCR. Real-time RT-PCR for SARS-CoV-2, using a method developed by the National Institute of Infectious Diseases, Japan, served as the reference RT-PCR method. Results: During the study period, 1,127 nasopharyngeal samples (symptomatic patients: 802, asymptomatic patients: 325) were evaluated. For digital immunoassay antigen tests, the sensitivity was 78.3% (95% CI: 67.3%-87.1%) and the specificity was 97.6% (95% CI: 96.5%-98.5%). When technicians visually analyzed the antigen test results, the sensitivity was 71.6% (95% CI: 59.9%-81.5%) and the specificity was 99.2% (95% CI: 98.5%-99.7%). Among symptomatic patients, the sensitivity was 89.4% (95% CI; 76.9%-96.5%) with digital immunoassay antigen tests, and 85.1% (95% CI; 71.7%-93.8%) with visually analyzed the antigen test, respectively. Conclusions: The findings indicated that RapidTesta SARS-CoV-2 analysis with the DIA device had sufficient analytical performance for the detection of SARS-CoV-2 in nasopharyngeal samples. When positive DIA results are recorded without a visually recognizable red line at the positive line location on the test cassette, additional RT-PCR evaluation should be performed.


2019 ◽  
Vol 20 (24) ◽  
pp. 6260 ◽  
Author(s):  
Tobiloba Sojinrin ◽  
Kangze Liu ◽  
Kan Wang ◽  
Daxiang Cui ◽  
Hugh J. Byrne ◽  
...  

Lateral flow immunochromatographic assays are a powerful diagnostic tool for point-of-care tests, based on their simplicity, specificity, and sensitivity. In this study, a rapid and sensitive gold nanoparticle (AuNP) immunochromatographic strip is produced for detecting aflatoxin B1 (AFB1) in suspicious fungi-contaminated food samples. The 10 nm AuNPs were encompassed by bovine serum albumin (BSA) and AFB1 antibody. Thin-layer chromatography, gel electrophoresis and nuclear magnetic resonance spectroscopy were employed for analysing the chemical complexes. Various concentrations of AFB1 antigen (0–16 ng/mL) were tested with AFB1 antibody–BSA–AuNPs (conjugated AuNPs) and then analysed by scanning electron microscopy, ultraviolet–visible spectroscopy, and Zetasizer. The results showed that the AFB1 antibody was coupled to BSA by the N-hydroxysuccinimide ester method. The AuNPs application has the potential to contribute to AFB1 detection by monitoring a visible colour change from red to purple-blue, with a detection limit of 2 ng/mL in a 96-well plate. The lateral flow immunochromatographic strip tests are rapid, taking less than 10 min., and they have a detection capacity of 10 ng/g. The smartphone analysis of strips provided the results in 3 s, with a detection limit of 0.3 ng/g for AFB1 when the concentration was below 10 ng/g. Excellent agreement was found with AFB1 determination by high-performance liquid chromatography in the determination of AFB1 among 20 samples of peanuts, corn, rice, and bread.


2021 ◽  
Author(s):  
Laura Ford ◽  
Melissa J. Whaley ◽  
Melisa M. Shah ◽  
Phillip P. Salvatore ◽  
Hannah E. Segaloff ◽  
...  

Background: Performance characteristics of SARS-CoV-2 antigen tests among children are limited despite the need for point-of-care testing in school and childcare settings. We describe children seeking SARS-CoV-2 testing at a community site and compare antigen test performance to real-time reverse transcription-polymerase chain reaction (RT-PCR) and viral culture. Methods: Two anterior nasal specimens were self-collected for BinaxNOW antigen and RT-PCR testing, along with demographics, symptoms, and exposure information from individuals ≥5 years at a community testing site. Viral culture was attempted on residual antigen or RT-PCR positive specimens. Demographic and clinical characteristics, and the performance of SARS-CoV-2 antigen tests, were compared among children (<18 years) and adults. Results: About one in ten included specimens were from children (225/2110); 16.4% (37/225) were RT-PCR positive. Cycle threshold values were similar among RT-PCR positive specimens from children and adults (22.5 vs 21.3, p=0.46) and among specimens from symptomatic and asymptomatic children (22.5 vs 23.2, p=0.39). Sensitivity of antigen test compared to RT-PCR was 73.0% (27/37) among specimens from children and 80.8% (240/297) among specimens from adults; among specimens from children, specificity was 100% (188/188), positive and negative predictive value were 100% (27/27) and 94.9% (188/198) respectively. Virus was isolated from 51.4% (19/37) of RT-PCR positive pediatric specimens; all 19 had positive antigen test results. Conclusions : With lower sensitivity relative to RT-PCR, antigen tests may not diagnose all positive COVID-19 cases; however, antigen testing identified children with live SARS-CoV-2 virus.


2020 ◽  
Author(s):  
Paul K. Drain ◽  
Madhavi Ampajwala ◽  
Christopher Chappel ◽  
Andre B. Gvozden ◽  
Melanie Hoppers ◽  
...  

AbstractBackgroundThe LumiraDx SARS-CoV-2 antigen test, which uses a high-sensitivity, microfluidic immunoassay to detect the nucleocapsid protein of SARS-CoV-2, was evaluated for diagnosing acute COVID-19 in adults and children across point-of-care settings.MethodsTwo paired anterior nasal swabs or two paired nasopharyngeal swabs were collected from each participant. Swabs were tested by the LumiraDx SARS-CoV-2 antigen test and compared with real-time PCR (rt-PCR; Roche cobas 6800 platform). Positive- and negative predictive values and likelihood ratios were calculated. Results stratified based on gender, age, duration of symptoms, and rt-PCR cycle threshold.ResultsOut of the 512 participants, aged 0-90 years, of this prospective validation study, 414 (81%) were symptomatic for COVID-19 and 123 (24%) swabs were positive for SARS-CoV-2 based on rt-PCR testing. Compared with rt-PCR, the 12-minute swab test had 97.6% sensitivity and 96.6% specificity within 12 days of symptom onset, representing the period of infectivity. All (100%) samples detected within 33 rt-PCR cycles were also identified using the antigen test. Results were consistent across age and gender. Despite being performed by minimally trained healthcare workers, the user error rate of the test system was 1%.ConclusionThe rapid high-sensitivity assay using nasopharyngeal or anterior nasal sampling may offer significant improvements for diagnosing acute SARS-CoV-2 infection in clinic- and community-based settings.SummaryA 12-minute nasal swab test detects 97.6% of COVID-19 infections, compared to gold standard real-time PCR testing, up to 12 days following symptom onset using a microfluidic immunoassay for SARS-CoV-2 nucleocapsid protein.