The experimental behavior of CFRP-strengthened reinforced concrete slabs with fire protection systems subjected to standard fire exposure

Author(s):  
Saeed Bakhtiyari ◽  
Arsalan Kalali ◽  
Leila Taghi Akbari ◽  
Farhang Farahbod

PurposeThis paper aims to evaluate fire resistance of carbon fiber-reinforced polymer (CFRP)-strengthened concrete slabs in two forms of unprotected and protected against fire. Design/methodology/approachTo achieve the objective, an unstrengthened and two CFRP-strengthened concrete slabs were first subjected to increasing gravity loading until failure. Subsequently, the unstrengthened concrete slab was placed on a furnace and was subjected to a constant service gravity load and then, the temperature of the furnace was increased according to a standard temperature–time curve until the failure of the slab occurred. This slab was strengthened by CFRP with two different amounts and then, in two cases of unprotected and protected against fire, was tested in accordance with the aforementioned method. FindingsThe gravity test results revealed that CFRP strips bonded to concrete slabs increased the load-bearing capacity considerably. So, this method can be suitable for flexural strengthening of concrete slabs. The fire test results showed that because of more load-bearing capacity and subsequently increase in service gravity load, the strengthened concrete slab failed in a short time due to the lack of CFRP resistance against fire. By contrast, the protected specimens resisted the fire in a considerable time. In addition, it was revealed that details of fire protective coating had an important effect on fire resistance duration. Originality/valueIt is notable that in the literature, there is a lack of data on the fire endurance of fiber-reinforced polymer-strengthened concrete slabs alone without any fire protection system. Furthermore, the applicability and effectiveness of a new kind of spray mineral fire protective coatings was evaluated.

2011 ◽  
Vol 18 (1-2) ◽  
pp. 69-77 ◽  
Author(s):  
Sevket Ozden ◽  
Hilal Meydanli Atalay

AbstractThe strength and post-peak performance of reinforced concrete corbels, strengthened with epoxy bonded glass fiber reinforced polymer (GFRP) overlays, were experimentally investigated. The test variables were the corbel shear span to depth ratio, corbel main reinforcement ratio, and the number and orientation of the GFRP fibers. In total, 24 normal strength concrete, one-third scale, corbel specimens, without hoop reinforcement, were tested to failure under quasi-static gravity loading. Test results revealed that GFRP overlays can easily be used for the enhancement of corbel load bearing capacity, depending on the fiber orientation. The main reinforcement ratio and the number of GFRP plies were found to be the two main variables affecting the level of strength gain in the corbel specimens.


2012 ◽  
Vol 4 (2) ◽  
pp. 45-58
Author(s):  
Gediminas Razma ◽  
Audronis Kazimieras Kvedaras

The paper presents fire design of composite steel-concrete slabs and a description of the use of the advantages of such a structure. Following the review of scientific literature on composite steel-concrete slabs, behaviour under fire temperature may confirm that this solution has no negative consequences for the construction of the building in fire. Profiled steel sheet is a very important building component, because it helps ensuring integrity and insulation properties. Such sheeting serves as a restraint preventing the spread of fire and hot gases, as well as protects the concrete from direct heat action not allowing its chipping off. Fire tests show that the construction of composite steel-concrete slabs without a protective coating under influence of fire is an important bracing frame provided by these conditions. In addition, it may be too conservative to establish the fire resistance coefficient for each element. Maybe it is not necessary to protect all load bearing steel elements in a building from fire, especially when they are in one setup with composite steel-concrete slabs. Fire protection methods make it possible for composite steel-concrete slabs to behave under a plastic bending moment allowing increased temperatures and distributing evenly in an element. The paper provides a brief description of methods for fire design. It analyzes the fire design method according to EN 1994-1-2:2005 regarding unprotected composite steel-concrete slabs exposed to fire from the bottom according to the standard temporary temperature curve. The paper provides an example of the calculation of composite steel-concrete slab according to described method without longitudinal reinforcement and the composite slab with longitudinal reinforcement. Results of calculations let to designate fire resistance of composite slab to heat isolation (I parameter) and the resistance value of the bending moment. Solutions for extra fire protection or increasing bending moment value depend on estimated results. Santrauka Straipsnyje nagrinėjamas kompozitinių plieninių-betoninių plokščių elgsena ugnyje. Pateikiamas kompozitinės plieninės-betoninės plokštės aprašymas ir tokios konstrukcijos naudojimo pranašumai. Trumpai aprašyti konstrukcijų elgsenos ugnyje skaičiavimo būdai. Pristatomas neapsaugotųjų kompozitinių plokščių, iš apačios veikiamų gaisro pagal standartinę laikinę temperatūros kreivę, elgsenos ugnyje skaičiavimo modelis pagal EN 1994-1-2:2005. Pagal aptartą modelį atlikti teoriniai kompozitinės plieninės-betoninės plokštės laikomojo lenkiamojo momento skaičiavimai, kai nėra išilginės armatūros ir kai plokštė armuota išilgine armatūra.


2014 ◽  
Vol 1079-1080 ◽  
pp. 258-265
Author(s):  
Chen Ning Cai ◽  
Shan He ◽  
Li Na Liu ◽  
Shi Kun Ou

Thispaper presents an experimental study to strengthen an existing bridge usingpre-stressed carbon fiber reinforced polymer (CFRP) and glass fiber reinforced polymer(GFRP) materials. The method using pre-stressed hybrid fiber reinforced polymer(HFRP) to strengthened structural members is an emerging pre-stressed strengtheningtechnology. In this study, experimental data selected from result of staticloading test conducted to hollow slabs with CFRP/GFRP has been compared with specimenswithout strengthening. Test results showed that the strengthening methoddeveloped in this study could effectively reduce the stress in hollow slab,improving the flexural rigidity and inhibiting the concrete from fracture.


2021 ◽  
Vol 11 (6) ◽  
pp. 2736
Author(s):  
Min Sook Kim ◽  
Young Hak Lee

In this study, the structural behavior of reinforced concrete flat plates shear reinforced with vertical grids made of a glass fiber reinforced polymer (GFRP) was experimentally evaluated. To examine the shear strength, experiments were performed on nine concrete slabs with different amounts and spacings of shear reinforcement. The test results indicated that the shear strength increased as the amount of shear reinforcement increased and as the spacing of the shear reinforcement decreased. The GFRP shear reinforcement changed the cracks and failure mode of the specimens from a brittle punching to flexure one. In addition, the experimental results are compared with a shear strength equation provided by different concrete design codes. This comparison demonstrates that all of the equations underestimate the shear strength of reinforced concrete flat plates shear reinforced with GFRP vertical grids. The shear strength of the equation by BS 8110 is able to calculate the punching shear strength reasonably for a concrete flat plate shear reinforced with GFRP vertical grids.


2021 ◽  
pp. 136943322199249
Author(s):  
Xing Li ◽  
Jiwen Zhang ◽  
Jun Cheng

This paper presents fatigue behaviors and the stiffness degradation law of concrete continuous beams with external prestressed carbon fiber-reinforced polymer (CFRP) tendons. Three specimens were tested under fatigue loading, and the influence of different load levels on the stiffness degradation and fatigue life were studied, and it was found that the stiffness degradation of three test specimens exhibited a three-stage change rule, namely rapid decrease, stable degradation, and sharp decline, but there are obvious differences in the rate and amplitude of stiffness degradation. The load level has a significant influence on the fatigue life of the test specimens. An analytical model with load level considered was proposed to calculate the residual stiffness and predict the stiffness degradation, which is in good agreement with the test results. The model of stiffness degradation presents a possible solution for practical engineering applications of concrete continuous beams with externally prestressed CFRP tendons subjected to different fatigue loadings.


2017 ◽  
Vol 747 ◽  
pp. 220-225
Author(s):  
Alberto Pedro Busnelli ◽  
Ruben Edgardo López ◽  
Jorge Carlos Adue

This is the presentation of the research carried out by the Faculty of Engineering at Universidad Nacional de Rosario on the use of pultruded Glass Fiber Reinforced Polymer (GFRP) plates to increase the flexural strength of reinforced concrete beams.Pultruded plates are the type of elements made of composite materials which are most widely used for this kind of strengthening. Although around the world the material used for these plates is carbon fibers, its high cost prevents its widespread use in our country.One of the aims of our research program is, precisely, to verify whether it is possible to substitute such plates for significantly cheaper glass fiber elements manufactured in Argentina. The test results have proved that this alternative is feasible.What's more, the greater thickness of the glass fiber plates allows the use of additional anchor bolts. These bolts provide the system with post-critical resistance and ductility-characteristics which are absolutely necessary, for example, in structures in seismic areas.


2008 ◽  
Vol 35 (3) ◽  
pp. 312-320 ◽  
Author(s):  
A. Zaidi ◽  
R. Masmoudi

The difference between the transverse coefficients of thermal expansion of fiber reinforced polymer (FRP) bars and concrete generates radial pressure at the FRP bar – concrete interface, which induces tensile stresses within the concrete under temperature increase and, eventually, failure of the concrete cover if the confining action of concrete is insufficient. This paper presents the results of an experimental study to investigate the thermal effect on the behaviour of FRP bars and concrete cover, using concrete slab specimens reinforced with glass FRP bars and subjected to thermal loading from –30 to +80 °C. The experimental results show that failure of concrete cover was produced at temperatures varying between +50 and +60 °C for slabs having a ratio of concrete cover thickness to FRP bar diameter (c/db) less than or equal to 1.4. A ratio of c/db greater than or equal to 1.6 seems to be sufficient to avoid splitting failure of concrete cover for concrete slabs subjected to high temperatures up to +80 °C. Also, the first cracks appear in concrete at the FRP bar – concrete interface at temperatures around +40 °C. Comparison between experimental and analytical results in terms of thermal loads and thermal strains is presented.


2017 ◽  
Vol 2017 ◽  
pp. 1-14 ◽  
Author(s):  
S.-K. Lee ◽  
S.-Y. Yoo ◽  
C.-G. Park

This study evaluated the performance of a hybrid panel that can overcome the current problem of corrosion of the steel panels of improved movable weirs when they are exposed to a sulfate and calcium chloride environment such as sea water. A hybrid panel with glass fiber-reinforced polymer (GFRP) layers on both sides of a steel panel means that the central panel is not exposed to the external elements, which can avoid corrosion problems. In this study, to maximize the hybrid panel’s strength and durability, the moisture absorption characteristics and the durability in an accelerated environment were evaluated. The test results were considered to indicate no durability issues as the final absorption ratio was approximately 2.0% or less in all environments. Also, from the accelerated deterioration test results when the steel panel processed by sand blasting was applied in all accelerated deterioration environments, it satisfied the residual strength level of 65% or more. However, in the case without surface processing, upon exposure to MgSO4 solution, it did not satisfy the standard residual strength level of 65%. These results show that sand blasting on the surface of a steel panel is adequate for hybrid panels for improved movable weirs.


Sign in / Sign up

Export Citation Format

Share Document