A study on different techniques of restoration of fire damaged reinforced concrete flexural members

2017 ◽  
Vol 8 (2) ◽  
pp. 131-148
Author(s):  
Danie Roy Anasco Bastin ◽  
Umesh Kumar Sharma ◽  
Pradeep Bhargava

Purpose The main aim of this research was to investigate the effectiveness of various strengthening techniques in restoring the structural performance of reinforced concrete (RC) beams damaged by elevated temperatures. Design/methodology/approach Three different strengthening techniques, namely, high-strength fibre reinforced concrete (HSFRC), ferrocement (FC) jacketing and externally bonded fibre-reinforced polymer (FRP) were used. Series of RC beams were casted, heated, strengthened and tested to investigate the influence of various variables. The variables of the study were type of strengthening and level of heat damage. Findings Externally bonded FRP was found to be the best among the various techniques, especially with respect to strength and stiffness restoration. On the contrary, the FRP strengthening was not that effective in restoring the energy absorption capacity of beams compared to HSFRC and FC techniques of strengthening. The chosen strengthening techniques were able to restore the failure mode of beams to flexural failure, which was found to have changed to shear failure in case of heated unstrenghthened beams. Originality/value This research program has contributed to the fundamental understanding of designing post fire retrofit solutions for RC beams.

2012 ◽  
Vol 18 (2) ◽  
pp. 217-226 ◽  
Author(s):  
Guray Arslan

The shear failure of reinforced concrete beams is one of the fundamental problems in civil engineering; however, the diagonal tension strength of reinforced concrete (RC) beams without stirrups is still in question. This paper focuses on the prediction of diagonal cracking strength of RC slender beams without stirrups. In slender beams, flexural cracks develop in the tension zone prior to a diagonal cracking. Using the basic principles of mechanics, but cracking included, and theory of elasticity, a diagonal cracking strength equation is proposed for both normal and high strength concrete beams. The proposed equation, the requirements of six codes of practice and seven equations proposed by different researchers are compared to the experimental results of 282 beams available in the literature. It is found that the predictions from the proposed equation are in good agreement with the experimental results. Santrauka Gelžbetoninių sijų suirimas įstrižajame pjūvyje – viena pagrindinių problemų statybos inžinerijoje. Tačiau skersine armatūra nearmuotų gelžbetoninių sijų įstrižasis tempiamasis stipris nėra visiškai ištirtas. Šiame straipsnyje nagrinėjamas siaurų, be skersinės armatūros gelžbetoninių sijų įstrižojo pjūvio pleišėjimas. Siaurose sijose plyšiai tempiamojoje zonoje atsiranda anksčiau negu įstrižajame pjūvyje. Taikant klasikinius mechanikos principus ir tamprumo teoriją, pasiūlyta normalaus stiprio arba stipriojo betono sijų istrižojo pjūvio atsparumo pleišėjimui apskaičiavimo lygtis. Siūloma lygtis, pagrįsta šešių projektavimo normų reikalavimais ir septyniomis kitų autorių lygtimis bei palyginta su literatūroje pateiktais 282 sijų eksperimentinių tyrimų rezultatais. Nustatyta, kad pagal siūlomą lygtį atlikti skaičiavimai gerai sutampa su eksperimentiniais rezultatais.


2018 ◽  
Vol 15 (2) ◽  
pp. 744-751
Author(s):  
S. Margaret Jesse ◽  
V. M. Shanthi

Strengthening Reinforced Concrete (RC) beams using FRP laminate becomes one of the main strengthening techniques. Failure of these beams is usually controlled by the bond strength between the laminate and the concrete. This paper presents the results of experimental investigation on six reinforced concrete beams, with various types, which were tested under two-point loading. The aim of the work was to study the efficacy of Carbon Fiber Reinforced Polymer (CFRP) sheets in enhancing the beam strength and stiffness from shear failure or flexural failure. The strengthening and deflection of the beams were carried out with cyclic loading. Experimental data on ultimate load, deflection and failure modes of each of the beams were obtained. For the comparison of CFRP sheet with cement concrete and the retrofitted specimens absorbs more energy, the CFRP beams yield a good result.


2020 ◽  
Vol 6 ◽  
pp. 69-85
Author(s):  
Mahir M. Hason ◽  
Ammar N. Hanoon ◽  
Ahmed W. Al Zand ◽  
Ali A. Abdulhameed ◽  
Ali O. Al-Sulttani

The impacts of numerous important factors on the Energy Absorption (EA) of torsional Reinforced Concrete (RC) beams strengthened with external FRP is the main purpose and innovation of the current research. A total of 81 datasets were collected from previous studies, focused on the investigation of EA behaviour. The impact of nine different parameters on the Torsional EA of RC-beams was examined and evaluated, namely the concrete compressive strength (f’c), steel yield strength (fy), FRP thickness (tFRP), width-to-depth of the beam section (b/h), horizontal (ρh) and vertical (ρv) steel ratio, angle of twist (θu), ultimate torque (Tu), and FRP ultimate strength (fy-FRP). For the evaluation of the energy absorption capacity at different levels, Response Surface Methodology (RSM) was implemented in this study. Also, to fit the measured results, Quadratic and Line models were created. The results show that the RSM technique is a highly significant tool that can be applied not only to energy absorption-related problems examined in this research, but also to other engineering problems. An agreement is observed between Pareto and standardized charts with the literature showing that the EA capacity of the torsional FRP-RC beams is mostly affected by the concrete compressive strength, followed by the vertical reinforcement ratio. The newly suggested model in this article exhibits a satisfactory correlation co-efficient (R), of about 80%, with an adequate level of accuracy. The obtained results also reveal that the EA acts as a safety index for the FRP-strengthened RC beams exposed to torsional loadings to avoid sudden structural damage. Doi: 10.28991/cej-2020-SP(EMCE)-07 Full Text: PDF


2008 ◽  
Vol 64 (3) ◽  
pp. 435-448
Author(s):  
Tetsuo KAWAGUCHI ◽  
Makoto KATAGIRI ◽  
Kazuyoshi SHIRAI ◽  
Junichiro NIWA

2012 ◽  
Vol 18 (31) ◽  
pp. 222-229
Author(s):  
Chunyakom Sivaleepunth ◽  
Toshimichi Ichinomiya ◽  
Shinichi Yamanobe ◽  
Tetsuya Kono ◽  
Naoki Sogabe ◽  
...  

2016 ◽  
Vol 2 (5) ◽  
pp. 168-179
Author(s):  
Kian Aghani ◽  
Hassan Afshin

Different methods are used for retrofitting RC members. One of the new methods in this field is using externally bonded fiber-reinforced Concrete (FRC) sheets in order to increase RC member’s shear and flexural strength. In this study, applicability of ultra-high performance fiber-reinforced concrete sheets in shear and flexural retrofitting of RC beams was investigated. In total, eight RC beams (dimensions 10×20×150 cm) with two different bending capacity and lack of shear strength were used and were tested in 3-points bending test. Of these, four were control beams and four were retrofitted with laterally bonded UHPFRC sheets. Dimensions of the sheets used for retrofitting were (3×15×126 cm). Also FEM analysis was used to model the effect of The method. the results show that this method can be well used for retrofitting RC beams. In this method the way of connecting sheets to beam’s surfaces has a fundamental role in behavior of retrofitted beams.


2021 ◽  
Vol 28 (1) ◽  
pp. 71-83
Author(s):  
Mazin Abdulrahman ◽  
Shakir Salih ◽  
Rusul Abduljabbar

In this research, an experimental study is conducted to investigate the behavior and strength of high strength reinforced concrete corbels externally bonded with CFRP fabric sheets and Plates with different patterns taking into account the effect of adopted variables in enhancing the ultimate strength; the effect of shear span to effective depth (a/d), configuration, type and amount of bonding. Eleven high strength reinforced corbels were cast and tested under vertical loads. Test results showed there was an improvement in the behavior and load carrying capacity of all strengthened corbels. An increasing in the ultimate strength of strengthened corbel by inclined CFRP strips reached to (92.1%) while the increasing reached to (84.21%) for using one horizontal CFRP Plates compared to un-strengthened reference specimen. Also, it can be conducted that the increase of (a/d) ratio from (0.6 to 0.8) resulted in decreasing by 21.05% in ultimate load capacity of corbels and from (0.4 to 0.6) by 31.25% and 58.69% in cracking and ultimate loads respectively Using CFRP .


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Sachin Vijaya Kumar ◽  
N. Suresh

PurposeThe Reinforced Concrete(RC) elements are known to perform well during exposure to elevated temperatures. Hence, RC elements are widely used to resist the extreme heat developing from accidental fires and other industrial processes. In both of the scenarios, the RC element is exposed to elevated temperatures. However, the primary differences between the fire and processed temperatures are the rate of temperature increase, mode of exposure and exposure durations. In order to determine the effect of two heating modalities, RC beams were exposed to processed temperatures with slow heating rates and fire with fast heating rates.Design/methodology/approachIn the present study, RC beam specimens were exposed to 200 °C, to 800 °C temperature at 200 °C intervals for 2 h' duration by adopting two heating modes; Fire and processed temperatures. An electrical furnace with low-temperature increment and a fire furnace with standard time-temperature increment is adapted to expose the RC elements to elevated temperatures.FindingsIt is observed from test results that, the reduction in load-carrying capacity, first crack load, and thermal crack widths of RC beams exposed to 200 °C, and 600 °C temperature at fire is significantly high from the RC beams exposed to the processed temperature having the same maximum temperature. As the exposure temperature increases to 800 °C, the performance of RC beams at all heating modes becomes approximately equal.Originality/valueIn this work, residual performance, and failure modes of RC beams exposed to elevated temperatures were achieved through two different heating modes are presented.


Author(s):  
Antoine N. Gergess ◽  
Mahfoud Shaikh Al Shabab ◽  
Razane Massouh

High-strength cementitious materials such as high-performance concrete are extensively used for retrofit of reinforced concrete (RC) structures. The effectiveness of these materials is increased when mixed with steel fibers. A commonly used technique for strengthening and repair of RC beams consists of applying high-performance fiber-reinforced concrete jackets around the beam perimeter. This paper investigates the jacketing method for repairing severely damaged RC beams. Four 2 m (6 ft 63/4 in.) long rectangular RC beams, 200 × 300 mm (8 ×12 in.) were initially cast and loaded until failure based on three-point bending tests. The four beams were then repaired by thickening the sides of the damaged RC beams using a commercially available high-strength shrinkage grout with and without steel fibers. Strain and deformation were recorded in the damaged and repaired beams to compare structural performance. It is shown that the flexural strength of the repaired beams is increased and the crack pattern under loading is improved, proving that the proposed repair method can restore the resistance capacity of RC beams despite the degree of damage. A method for repair is proposed and an analytical investigation is also performed to understand the structural behavior of the repaired beams based on different thickening configurations.