CFD investigation of temperature distribution, air flow pattern and thermal comfort in natural ventilation of building using solar chimney

2020 ◽  
Vol 17 (1) ◽  
pp. 78-86 ◽  
Author(s):  
Maher Dhahri ◽  
Hana Aouinet

Purpose The purpose of this study is to investigate air flow, temperature distribution and thermal confort in natural ventilation induced by solar chimney for different operating. Design/methodology/approach Numerical simulation is performed using a commercial computational fluid dynamics (CFD) package ANSYS CFX software to understand the effects of air temperature, air velocity and solar heat flux on the performance of the solar chimney and thermal comfort. The comfort level was evaluated using the air diffusion performance index (ADPI) according to ASHRAE (55-210). The flow was investigated at inclination angles 45° solar heat flux 550-750 W/m2 and in a solar chimney of 1.4 m length, 0.6 m width and 0.20 m air gab. Findings The numerical results from the present simulation were first validated with experimental data, which was used for the thermal comfort indexes calculation. The obtained results of the analysis showed that the used numerical technique could accurately predict air flow and temperature distribution in natural ventilated building using solar chimney; the air temperature, air velocity and solar heat flux have a significant impact on thermal comfort; the temperature of 19°C with velocity of 0.15 m.s−1 gives the best effective draft temperature (EDT) satisfy ASHRAE (55-210) criteria that V = 0.35 m.s−1 and EDT range between −1.7 and 1.1. Originality/value In the present paper, air flow, temperature distribution and thermal comfort inside a room equipped with inclined solar chimney were numerically investigated and analyzed. The commercial CFD package (CFX 15) is used. Calculations are carried out in an empty room without any human or mechanical activity and the numerical results are compared with measurement points.

Author(s):  
B. P. Huynh

Natural-ventilation flow induced in a real-sized rectangular-box room fitted with a solar chimney on its roof is investigated numerically, using a commercial CFD (Computational Fluid Dynamics) software package. The chimney in turn is in the form of a parallel channel with one plate being subjected to uniform solar heat flux. Ventilation rate and air-flow pattern through the room are considered in terms of the heat flux for two different locations of the room’s inlet opening. Chien’s turbulence model of low-Reynolds-number K-ε is used in a Reynolds-Averaged Navier-Stokes (RANS) formulation. It is found that ventilation flow rate increases quickly with solar heat flux when this flux is low, but more gradually at higher flux. At low heat flux, ventilation rate is not significantly affected by location of the inlet opening to the room. On the other hand, at high heat flux, ventilation rate varies substantially with the opening’s location. Location of the inlet opening to the room also affects strongly the air-flow pattern. In any case, ample ventilation rate is readily induced by the chimney.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Hamza Laloui ◽  
Noor Hanita Abdul Majid ◽  
Aliyah Nur Zafirah Sanusi

Purpose This paper aims to investigate the impacts of introducing voids combinations on natural ventilation performance in high-rise residential building living unit. Design/methodology/approach This study was carried out through field measurement and computational fluid dynamics methods. The parameters of the study are void types and sizes, and a wind angle was used to formulate case studies. Findings The results indicate that the provision of a single-sided horizontal void larger by 50% increase the indoor air velocity performance up to 322.37% to 0.471 m/s in the living unit and achieves the required velocity for thermal comfort. Originality/value Passive design features are the most desirable techniques to enhance natural ventilation performance in the high-rise residential apartments for thermal comfort and indoor air quality purposes.


2014 ◽  
Vol 672-674 ◽  
pp. 109-112 ◽  
Author(s):  
Cai Xia Hao ◽  
Hai Ping Zhang ◽  
Min Xia Hao

The vertical panels of solar chimney have internal dimensions of 2000mm height、1000mm length. Under the condition of heat flux and chimney gap variety, we research chimney interior velocity field. Experimental Results show that airflow increased with chimney gap augmentation, the airflow and air velocity augment with the increase of solar radiant intensity, and air velocity decreases with the increase of solar chimney gap. Air velocity is higher near the heated surfaces than it in the middle chimney. Meanwhile velocity boundary layers form near the heated surface.


Author(s):  
Elahe Mirabi ◽  
Nasrollahi Nazanin

<p>Designing urban facades is considered as a major factor influencing issues<br />such as natural ventilation of buildings and urban areas, radiations in the<br />urban canyon for designing low-energy buildings, cooling demand for<br />buildings in urban area, and thermal comfort in urban streets. However, so<br />far, most studies on urban topics have been focused on flat facades<br />without details of urban layouts. Hence, the effect of urban facades with<br />details such as the balcony and corbelling on thermal comfort conditions<br />and air flow behavior are discussed in this literature review. <strong>Aim</strong>: This<br />study was carried out to investigate the effective factors of urban facades,<br />including the effects of building configuration, geometry and urban<br />canyon’s orientation. <strong>Methodology and Results</strong>: According to the results,<br />the air flow behavior is affected by a wide range of factors such as wind<br />conditions, urban geometry and wind direction. Urban façade geometry<br />can change outdoor air flow pattern, thermal comfort and solar access.<br /><strong>Conclusion, significance and impact study</strong>: In particular, the geometry of<br />the facade, such as indentation and protrusion, has a significant effect on<br />the air flow and thermal behavior in urban facades and can enhance<br />outdoor comfort conditions. Also, Alternation in façade geometry can<br />affect pedestrians' comfort and buildings energy demands.</p>


2014 ◽  
Vol 627 ◽  
pp. 153-157
Author(s):  
Nawadee Srisiriwat ◽  
Chananchai Wutthithanyawat

The temperature distribution of hot air flow in heating zone of a rectangular duct has been investigated for drying application. The experimental set-up consists of a heater and a fan to generate the hot air flow in the range of temperature from 40 to 100°C and the range of air velocity between 1.20 and 1.57 m/s. An increase of the heater power supply increases the hot air temperature in the heating zone while an increase of air velocity forced by fan decreases the initial temperature at the same power supply provided to generate the hot air flow. The temperature distribution shows that the hot air temperature after transferring through air duct decreases with an increase of the length of the rectangular duct. These results are very important for the air flow temperature and velocity control strategy to apply for heating zone design in the drying process.


Author(s):  
Mauro Cepeda ◽  
Santiago Morales F. ◽  
Viviana Cabrera

When high thermal comfort and energy efficiency are provided in an academic environment many beneficial effects on student’s comfort, performance, productivity, and health are shown. The research provides a parametric airflow evaluation of a skylight in a ground floor of new educational building assuming a variation of 4 stages with eight scenarios for the admissions office. By means of the bioclimatic analysis, Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD) indices, the best internal airflow performance for the study area applying natural ventilation is achieved with the air flow optimization. A minimum area of 1.79 m has been established for extraction and movement of the internal flow, both with the natural extraction louvers system measuring 12 inches by 60 inches and the 18 inches by 60 inches, they work properly. However, the 18 inches by 60 inches system has better effectiveness as it has fewer louver units to be placed, is more homogeneous, avoids turbulence and provides better air extraction. In addition, by having fewer louver units distributed along the length of the skylight, it will allow the operation to be more controlled during the operation of the building. The use of 8 louvers of those proportions, with an individual effective area of 0.23 m and a total of 1.84 m was recommended in accordance with the results obtained.


Author(s):  
Magdalena Nakielska ◽  
Krzysztof Pawłowski

Nowadays, people are looking for solutions related to ventilation, cooling or heat demand systems, which would be energy efficient and, at the same time, would not cause the degradation of the surrounding environment. As far as ventilation is concerned, an good solution is a natural ventilation, which improves thermal comfort rooms without increasing the consumption of electrical energy in the building. In order to improve the mode of action of the natural ventilation in the building, one can mount various elements supporting the air flow. One of them is a solar chimney. In order to check the correct operation of a gravity ventilation installation in Poland’s climatic conditions, the measurements was carried out on a test stand on the 3.1 building of UTP University of Science and Technology in Bydgoszcz. The received results show the intensification of the air flow through the room the value between 50% and 150%, depending on a measuring hour (Chen et al. 2003). These research results were compared with the research results received before the installation of the solar chimney on the ducts of the gravity ventilation.


2013 ◽  
Vol 361-363 ◽  
pp. 833-844
Author(s):  
Chong Jie Wang ◽  
Wei Wei Liu

Indoor fresh air distribution, temperature stratification and temperature distribution are consider to be the essential indicators when comes to evaluation of the comfort level for internal ventilation environment, particularly for natural ventilated space as target office building. It can be identified that the targeting building has been well designed in the respect of natural ventilation strategies where both cross and stack strategies have been adopted, but it is also obvious that under combined buoyancy and wind driven mode alternative problems appears.


Solar Energy ◽  
2015 ◽  
Vol 122 ◽  
pp. 795-803 ◽  
Author(s):  
Jean-Michel Dussault ◽  
Christian Kohler ◽  
Howdy Goudey ◽  
Robert Hart ◽  
Louis Gosselin ◽  
...  

2007 ◽  
Vol 20 (13) ◽  
pp. 3249-3268 ◽  
Author(s):  
Clémentde Boyer Montégut ◽  
Jérôme Vialard ◽  
S. S. C. Shenoi ◽  
D. Shankar ◽  
Fabien Durand ◽  
...  

Abstract A global ocean general circulation model (OGCM) is used to investigate the mixed layer heat budget of the northern Indian Ocean (NIO). The model is validated against observations and shows fairly good agreement with mixed layer depth data in the NIO. The NIO has been separated into three subbasins: the western Arabian Sea (AS), the eastern AS, and the Bay of Bengal (BoB). This study reveals strong differences between the western and eastern AS heat budget, while the latter basin has similarities with the BoB. Interesting new results on seasonal time scales are shown. The penetration of solar heat flux needs to be taken into account for two reasons. First, an average of 28 W m−2 is lost beneath the mixed layer over the year. Second, the penetration of solar heat flux tends to reduce the effect of solar heat flux on the SST seasonal cycle in the AS because the seasons of strongest flux are also seasons with a thin mixed layer. This enhances the control of SST seasonal variability by latent heat flux. The impact of salinity on SST variability is demonstrated. Salinity stratification plays a clear role in maintaining a high winter SST in the BoB and eastern AS while not in the western AS. The presence of freshwater near the surface allows heat storage below the surface layer that can later be recovered by entrainment warming during winter cooling (with a winter contribution of +2.1°C in the BoB). On an interannual time scale, the eastern AS and BoB are strongly controlled by the winds through the latent heat flux anomalies. In the western AS, vertical processes, as well as horizontal advection, contribute significantly to SST interannual variability, and the wind is not the only factor controlling the heat flux forcing.


Sign in / Sign up

Export Citation Format

Share Document