Rotating stall detection of axial compressor based on LabVIEW

Author(s):  
Min Wang ◽  
Jiaming Ou ◽  
Peng Lin
2021 ◽  
pp. 1-24
Author(s):  
Zeyuan Yang ◽  
Yadong Wu ◽  
Hua Ouyang

Abstract Rotating instability (RI) and rotating stall (RS) are two types of aerodynamic instability in axial compressors. The former features the side-by-side peaks below the blade passing frequency (BPF) in frequency spectra, and the latter represents one or more stall cells rotating in the compressor. This paper presents an experimental on the nearfield pressure and farfield acoustic characteristics of RI phenomenon in a low-speed axial compressor rotor, which endures both RI and RS at several working conditions. In order to obtain the high-order modes of RI and other aerodynamic instability, a total of 9 or 20 Kulites are circumferentially mounted on the casing wall to measure the nearfield pressure fluctuation using a mode order calibration method. Meantime in the farfield 16 microphones are planted to measure the acoustic mode order using the compressive sensing method. Through calibration the experiments acquire the mode orders generated by RI and the interaction between RI and BPF, which is higher than the number of transducers. As for RS, the mode decomposition shows a mode order of 1, indicating one single stall cell rotating in the compressor. This experiment also shows that amplitude of RI modes is decreased when RS occurs, but RS modes and RI modes will both be enhanced if the flow rate is further reduced. This experiment reveals that RI experiences three stages of “strengthen-weaken-strengthen”, and hence RI may not be regarded only as “prestall” disturbance.


2021 ◽  
Author(s):  
Zeyuan Yang ◽  
Yadong Wu ◽  
Hua Ouyang

Abstract Rotating instability (RI) and rotating stall (RS) are two types of aerodynamic instability in axial compressors. The former features the side-by-side peaks below the blade passing frequency (BPF) in frequency spectra, and the latter represents one or more stall cells rotating in the compressor. This paper presents an experimental on the nearfield pressure and farfield acoustic characteristics of RI phenomenon in a low-speed axial compressor rotor, which endures both RI and RS at several working conditions. In order to obtain the high-order modes of RI and other aerodynamic instability, a total of 9 or 20 Kulites are circumferentially mounted on the casing wall to measure the nearfield pressure fluctuation using a mode order calibration method. Meantime in the farfield 16 microphones are planted to measure the acoustic mode order using the compressive sensing method. Through calibration the experiments acquire the mode orders generated by RI and the interaction between RI and BPF, which is higher than the number of transducers. As for RS, the mode decomposition shows a mode order of 1, indicating one single stall cell rotating in the compressor. This experiment also shows that amplitude of RI modes is decreased when RS occurs, but RS modes and RI modes will both be enhanced if the flow rate is further reduced. This experiment reveals that RI experiences three stages of “strengthen-weaken-strengthen”, and hence RI may not be regarded only as “prestall” disturbance.


Author(s):  
Adam R. Hickman ◽  
Scott C. Morris

Flow field measurements of a high-speed axial compressor are presented during pre-stall and post-stall conditions. The paper provides an analysis of measurements from a circumferential array of unsteady shroud static pressure sensors during stall cell development. At low-speed, the stall cell approached a stable size in approximately two rotor revolutions. At higher speeds, the stall cell developed within a short amount of time after stall inception, but then fluctuated in circumferential extent as the compressor transiently approached a stable post-stall operating point. The size of the stall cell was found to be related to the annulus average flow coefficient. A discussion of Phase-Locked Average (PLA) statistics on flow field measurements during stable operation is also included. In conditions where rotating stall is present, flow field measurements can be Double Phase-Locked Averaged (DPLA) using a once-per-revolution (1/Rev) pulse and the period of the stall cell. The DPLA method provides greater detail and understanding into the structure of the stall cell. DPLA data indicated that a stalled compressor annulus can be considered to contained three main regions: over-pressurized passages, stalled passages, and recovering passages. Within the over-pressured region, rotor passages exhibited increased blade loading and pressure ratio compared to pre-stall values.


Author(s):  
Byeung Jun Lim ◽  
Tae Choon Park ◽  
Young Seok Kang

In this study, characteristics of stall inception in a single-stage transonic axial compressor with circumferential grooves casing treatment were investigated experimentally. Additionally, the characteristic of increasing irregularity in the pressure inside circumferential grooves as the compressor approaches the stall limit was applied to the stall warning method. Spike-type rotating stall was observed in the single-stage transonic axial compressor with smooth casing. When circumferential grooves were applied, the stall inception was suppressed and the operating point of the compressor moved to lower flow rate than the stall limit. A spike-like disturbance was developed into a rotating stall cell and then the Helmholtz perturbation was overlapped on it at N = 80%. At N = 70 %, the Helmholtz perturbation was observed first and the amplitude of the wave gradually increased as mass flow rate decreased. At N = 60%, spike type stall inceptions were observed intermittently and then developed into continuous rotating stall at lower mass flow rate. Pressure measured at the bottom of circumferential grooves showed that the level of irregularity of pressure increased as flow rate decreased. Based on the characteristic of increasing irregularity of the pressure signals inside the circumferential grooves as stall approaches, an autocorrelation technique was applied to the stall warning. This technique could be used to provide warning against stall and estimate real-time stall margins in compressors with casing treatments.


Author(s):  
Gabriel Margalida ◽  
Antoine Dazin ◽  
Pierric Joseph ◽  
Olivier Roussette

This paper presents experimental unsteady pressure measurements gathered on a single stage axial compressor during pre-stall and transition to stall operations. The aim of this study is to analyze the transition from a stable operating point to the fully developed rotating stall regime, and more specifically, the effect of the throttling process on the development of the instabilities. To do so, experiments have been repeated leading the compressor to stall operations with various throttling speed. On one hand, this paper analyses the effect of the throttling speed on the dynamic of the instability development from the first detection of spike type precursors to completely developed rotating stall. On the other hand, a stall warning signal based on the correlation of the instantaneous pressure signal with a reference pressure signal is built. The influence of the location of the pressure transducer used for the warning signal is first analyzed. Then an analysis of the effect of the throttling process on the time between the warning signal and the effective stall development is proposed.


Author(s):  
Ali Arshad ◽  
Qiushi Li ◽  
Simin Li ◽  
Tianyu Pan

Experimental investigations of the effect of inlet blade loading on the rotating stall inception process are carried out on a single-stage low-speed axial compressor. Temporal pressure signals from the six high response pressure transducers are used for the analysis. Pressure variations at the hub are especially recorded during the stall inception process. Inlet blade loading is altered by installing metallic meshed distortion screens at the rotor upstream. Three sets of experiments are performed for the comparison of results, i.e. uniform inlet flow, tip, and hub distortions, respectively. Regardless of the type of distortion introduced to the inflow, the compressor undergoes a performance drop, which is more severe in the hub distortion case. Under the uniform inlet flow condition, stall inception is caused by the modal type disturbance while the stall precursor switched to spike type due to the highly loaded blade tip. In the presence of high blade loading at the hub, spike disappeared and the compressor once again witnessed a modal type disturbance. Hub pressure fluctuations are observed throughout the process when the stall is caused by a modal wave while no disturbance is noticed at the hub in spike type stall inception. It is believed that the hub flow separation contributes to the modal type of stall inception phenomenon. Results are also supported by the recently developed signal processing techniques for the stall inception study.


Author(s):  
Jiaguo Hu ◽  
Tianyu Pan ◽  
Wenqian Wu ◽  
Qiushi Li ◽  
Yifang Gong

The instability has been the largest barrier of the high performance axial compressor in the past decades. Stall inception, which determines the route and the characteristics of instability evolution, has been extensively focused on. A new stall inception, “partial surge”, is discovered in the recent experiments. In this paper full-annulus transient simulations are performed to study the origin of partial surge initiated inception and explain the aerodynamic mechanism. The simulations show that the stall inception firstly occurs at the stator hub region, and then transfers to the rotor tip region. The compressor finally stalled by the tip region rotating stall. The stall evolution is in accord with the experiments. The stall evolution can be divided into three phases. In the first phase, the stator corner separation gradually merged with the adjacent passages, producing an annulus stall cell at the stator hub region. In the second phase, the total pressure rise of hub region emerges rapid decline due to the fast expansion of the annulus stall cell, but the tip region maintains its pressure rise. In the third phase, a new rotating stall cell appears at the rotor tip region, leading to the onset of fast drop of the tip region pressure rise. The stall cells transfer from hub region to the tip region is caused by two factors, the blockage of the hub region which transfers more load to the tip region, and the separation fluid fluctuations in stator domain which increase the circumferential non-uniformity in the rotor domain. High load and non-uniformity at the rotor tip region induce the final rotating stall.


Author(s):  
Senthil Krishnababu ◽  
Vili Panov ◽  
Simon Jackson ◽  
Andrew Dawson

Abstract In this paper, research that was carried out to optimise an initial variable guide vane schedule of a high-pressure ratio, multistage axial compressor is reported. The research was carried out on an extensively instrumented scaled compressor rig. The compressor rig tests carried out employing the initial schedule identified regions in the low speed area of the compressor map that developed rotating stall. Rotating stall regions that caused undesirable non-synchronous vibration of rotor blades were identified. The variable guide vane schedule optimisation carried out balancing the aerodynamic, aero-mechanical and blade dynamic characteristics gave the ‘Silent Start’ variable guide vane schedule, that prevented the development of rotating stall in the start regime and removed the non-synchronous vibration. Aerodynamic performance and aero-mechanical characteristics of the compressor when operated with the initial schedule and the optimised ‘Silent Start’ schedule are compared. The compressor with the ‘Silent Start’ variable guide vane schedule when used on a twin shaft engine reduced the start time to minimum load by a factor of four and significantly improved the operability of the engine compared to when the initial schedule was used.