Database Storage Format for High Performance Analytics of Immutable Data

Author(s):  
Mikhail M. Rovnyagin ◽  
Sviatoslav O. Dmitriev ◽  
Alexander S. Hrapov ◽  
Artem A. Maksutov ◽  
Igor A. Turovskiy
2017 ◽  
Vol 10 (4) ◽  
pp. 16
Author(s):  
Haifeng Jiang ◽  
Chang Wan

This paper introduces a method to realize dynamic interface, and designs a database storage model based on XML field technology to realize convenient data storage, any combination condition retrieval function and how to improve the retrieval speed in this kind of storage model. Usually a business system needs to provide information entry and retrieval functions, software designers have to design the appropriate entry items, input interface and retrieval functions for each business system and spend too much time on the repetitive works. And later engineers have to maintain the changing needs of the entry project, so we can apply the dynamic interface technology to achieve the customize needs of input items by the user, reducing the time of the repetitive works. Dynamic interface technology includes the realization of database storage and high performance data retrieval. This paper explores a storage model based on XML database to realize common and efficient storage and discuss on how to improve the retrieval speed in this kind of storage model.


2011 ◽  
Vol 14 (2) ◽  
Author(s):  
Pablo Ezzatti ◽  
Mónica Fossati ◽  
Ismael Piedra-Cueva

RMA-11 is a numerical model widely used for studing the transport of constituents andwater quality in rivers and estuaries. When applied to large water systems like the R´ıode la Plata, RMA-11 demands long execution times to compute a simulation. This pa-per presents the analysis of the computational efficiency for the RMA-11 applied to atransport model of the R´ıo de la Plata, and introduces a proposal for improving the effi-ciency by using high performance computing techniques. The improved implementationmodifies the linear system resolution methodology implemented in the model. A highperformance computing strategy was applied to the FRONTALL routine of the RMA-11,by changing their logical structure and using a sparse storage format. The experimentalresults obtained when solving representative test cases show a significant improvementon the performance, achieving significant gains in computational speed: the executiontime of the implemented version decreased up to one third of the time of the originalimplementation.


Author(s):  
A. V. Crewe ◽  
M. Isaacson ◽  
D. Johnson

A double focusing magnetic spectrometer has been constructed for use with a field emission electron gun scanning microscope in order to study the electron energy loss mechanism in thin specimens. It is of the uniform field sector type with curved pole pieces. The shape of the pole pieces is determined by requiring that all particles be focused to a point at the image slit (point 1). The resultant shape gives perfect focusing in the median plane (Fig. 1) and first order focusing in the vertical plane (Fig. 2).


Author(s):  
N. Yoshimura ◽  
K. Shirota ◽  
T. Etoh

One of the most important requirements for a high-performance EM, especially an analytical EM using a fine beam probe, is to prevent specimen contamination by providing a clean high vacuum in the vicinity of the specimen. However, in almost all commercial EMs, the pressure in the vicinity of the specimen under observation is usually more than ten times higher than the pressure measured at the punping line. The EM column inevitably requires the use of greased Viton O-rings for fine movement, and specimens and films need to be exchanged frequently and several attachments may also be exchanged. For these reasons, a high speed pumping system, as well as a clean vacuum system, is now required. A newly developed electron microscope, the JEM-100CX features clean high vacuum in the vicinity of the specimen, realized by the use of a CASCADE type diffusion pump system which has been essentially improved over its predeces- sorD employed on the JEM-100C.


Author(s):  
John W. Coleman

In the design engineering of high performance electromagnetic lenses, the direct conversion of electron optical design data into drawings for reliable hardware is oftentimes difficult, especially in terms of how to mount parts to each other, how to tolerance dimensions, and how to specify finishes. An answer to this is in the use of magnetostatic analytics, corresponding to boundary conditions for the optical design. With such models, the magnetostatic force on a test pole along the axis may be examined, and in this way one may obtain priority listings for holding dimensions, relieving stresses, etc..The development of magnetostatic models most easily proceeds from the derivation of scalar potentials of separate geometric elements. These potentials can then be conbined at will because of the superposition characteristic of conservative force fields.


Author(s):  
J W Steeds ◽  
R Vincent

We review the analytical powers which will become more widely available as medium voltage (200-300kV) TEMs with facilities for CBED on a nanometre scale come onto the market. Of course, high performance cold field emission STEMs have now been in operation for about twenty years, but it is only in relatively few laboratories that special modification has permitted the performance of CBED experiments. Most notable amongst these pioneering projects is the work in Arizona by Cowley and Spence and, more recently, that in Cambridge by Rodenburg and McMullan.There are a large number of potential advantages of a high intensity, small diameter, focussed probe. We discuss first the advantages for probes larger than the projected unit cell of the crystal under investigation. In this situation we are able to perform CBED on local regions of good crystallinity. Zone axis patterns often contain information which is very sensitive to thickness changes as small as 5nm. In conventional CBED, with a lOnm source, it is very likely that the information will be degraded by thickness averaging within the illuminated area.


Author(s):  
Klaus-Ruediger Peters

A new generation of high performance field emission scanning electron microscopes (FSEM) is now commercially available (JEOL 890, Hitachi S 900, ISI OS 130-F) characterized by an "in lens" position of the specimen where probe diameters are reduced and signal collection improved. Additionally, low voltage operation is extended to 1 kV. Compared to the first generation of FSEM (JE0L JSM 30, Hitachi S 800), which utilized a specimen position below the final lens, specimen size had to be reduced but useful magnification could be impressively increased in both low (1-4 kV) and high (5-40 kV) voltage operation, i.e. from 50,000 to 200,000 and 250,000 to 1,000,000 x respectively.At high accelerating voltage and magnification, contrasts on biological specimens are well characterized1 and are produced by the entering probe electrons in the outmost surface layer within -vl nm depth. Backscattered electrons produce only a background signal. Under these conditions (FIG. 1) image quality is similar to conventional TEM (FIG. 2) and only limited at magnifications >1,000,000 x by probe size (0.5 nm) or non-localization effects (%0.5 nm).


Author(s):  
G.K.W. Balkau ◽  
E. Bez ◽  
J.L. Farrant

The earliest account of the contamination of electron microscope specimens by the deposition of carbonaceous material during electron irradiation was published in 1947 by Watson who was then working in Canada. It was soon established that this carbonaceous material is formed from organic vapours, and it is now recognized that the principal source is the oil-sealed rotary pumps which provide the backing vacuum. It has been shown that the organic vapours consist of low molecular weight fragments of oil molecules which have been degraded at hot spots produced by friction between the vanes and the surfaces on which they slide. As satisfactory oil-free pumps are unavailable, it is standard electron microscope practice to reduce the partial pressure of organic vapours in the microscope in the vicinity of the specimen by using liquid-nitrogen cooled anti-contamination devices. Traps of this type are sufficient to reduce the contamination rate to about 0.1 Å per min, which is tolerable for many investigations.


Author(s):  
Lee D. Peachey ◽  
Lou Fodor ◽  
John C. Haselgrove ◽  
Stanley M. Dunn ◽  
Junqing Huang

Stereo pairs of electron microscope images provide valuable visual impressions of the three-dimensional nature of specimens, including biological objects. Beyond this one seeks quantitatively accurate models and measurements of the three dimensional positions and sizes of structures in the specimen. In our laboratory, we have sought to combine high resolution video cameras with high performance computer graphics systems to improve both the ease of building 3D reconstructions and the accuracy of 3D measurements, by using multiple tilt images of the same specimen tilted over a wider range of angles than can be viewed stereoscopically. Ultimately we also wish to automate the reconstruction and measurement process, and have initiated work in that direction.Figure 1 is a stereo pair of 400 kV images from a 1 micrometer thick transverse section of frog skeletal muscle stained with the Golgi stain. This stain selectively increases the density of the transverse tubular network in these muscle cells, and it is this network that we reconstruct in this example.


Author(s):  
Mark H. Ellisman

The increased availability of High Performance Computing and Communications (HPCC) offers scientists and students the potential for effective remote interactive use of centralized, specialized, and expensive instrumentation and computers. Examples of instruments capable of remote operation that may be usefully controlled from a distance are increasing. Some in current use include telescopes, networks of remote geophysical sensing devices and more recently, the intermediate high voltage electron microscope developed at the San Diego Microscopy and Imaging Resource (SDMIR) in La Jolla. In this presentation the imaging capabilities of a specially designed JEOL 4000EX IVEM will be described. This instrument was developed mainly to facilitate the extraction of 3-dimensional information from thick sections. In addition, progress will be described on a project now underway to develop a more advanced version of the Telemicroscopy software we previously demonstrated as a tool to for providing remote access to this IVEM (Mercurio et al., 1992; Fan et al., 1992).