Design on high performance GaAs latched comparator for data conversion applications

Author(s):  
S. Feng ◽  
D. Seitzer
2008 ◽  
Vol 5 (2) ◽  
Author(s):  
Yudong Sun ◽  
Steve McKeever

SummaryBiomolecular modelling has provided computational simulation based methods for investigating biological processes from quantum chemical to cellular levels. Modelling such microscopic processes requires atomic description of a biological system and conducts in fine timesteps. Consequently the simulations are extremely computationally demanding. To tackle this limitation, different biomolecular models have to be integrated in order to achieve high-performance simulations. The integration of diverse biomolecular models needs to convert molecular data between different data representations of different models. This data conversion is often non-trivial, requires extensive human input and is inevitably error prone. In this paper we present an automated data conversion method for biomolecular simulations between molecular dynamics and quantum mechanics/molecular mechanics models. Our approach is developed around an XML data representation called BioSimML (Biomolecular Simulation Markup Language). BioSimML provides a domain specific data representation for biomolecular modelling which can effciently support data interoperability between different biomolecular simulation models and data formats.


Symmetry ◽  
2020 ◽  
Vol 12 (4) ◽  
pp. 501 ◽  
Author(s):  
Shuai Zhang ◽  
Manchun Li ◽  
Zhenjie Chen ◽  
Tao Huang ◽  
Sumin Li ◽  
...  

Large-scale geospatial data have accumulated worldwide in the past decades. However, various data formats often result in a geospatial data sharing problem in the geographical information system community. Despite the various methodologies proposed in the past, geospatial data conversion has always served as a fundamental and efficient way of sharing geospatial data. However, these methodologies are beginning to fail as data increase. This study proposes a parallel spatial data conversion engine (PSCE) with a symmetric mechanism to achieve the efficient sharing of massive geodata by utilizing high-performance computing technology. This engine is designed in an extendable and flexible framework and can customize methods of reading and writing particular spatial data formats. A dynamic task scheduling strategy based on the feature computing index is introduced in the framework to improve load balancing and performance. An experiment is performed to validate the engine framework and performance. In this experiment, geospatial data are stored in the vector spatial data defined in the Chinese Geospatial Data Transfer Format Standard in a parallel file system (Lustre Cluster). Results show that the PSCE has a reliable architecture that can quickly cope with massive spatial datasets.


Author(s):  
A. V. Crewe ◽  
M. Isaacson ◽  
D. Johnson

A double focusing magnetic spectrometer has been constructed for use with a field emission electron gun scanning microscope in order to study the electron energy loss mechanism in thin specimens. It is of the uniform field sector type with curved pole pieces. The shape of the pole pieces is determined by requiring that all particles be focused to a point at the image slit (point 1). The resultant shape gives perfect focusing in the median plane (Fig. 1) and first order focusing in the vertical plane (Fig. 2).


Author(s):  
N. Yoshimura ◽  
K. Shirota ◽  
T. Etoh

One of the most important requirements for a high-performance EM, especially an analytical EM using a fine beam probe, is to prevent specimen contamination by providing a clean high vacuum in the vicinity of the specimen. However, in almost all commercial EMs, the pressure in the vicinity of the specimen under observation is usually more than ten times higher than the pressure measured at the punping line. The EM column inevitably requires the use of greased Viton O-rings for fine movement, and specimens and films need to be exchanged frequently and several attachments may also be exchanged. For these reasons, a high speed pumping system, as well as a clean vacuum system, is now required. A newly developed electron microscope, the JEM-100CX features clean high vacuum in the vicinity of the specimen, realized by the use of a CASCADE type diffusion pump system which has been essentially improved over its predeces- sorD employed on the JEM-100C.


Author(s):  
John W. Coleman

In the design engineering of high performance electromagnetic lenses, the direct conversion of electron optical design data into drawings for reliable hardware is oftentimes difficult, especially in terms of how to mount parts to each other, how to tolerance dimensions, and how to specify finishes. An answer to this is in the use of magnetostatic analytics, corresponding to boundary conditions for the optical design. With such models, the magnetostatic force on a test pole along the axis may be examined, and in this way one may obtain priority listings for holding dimensions, relieving stresses, etc..The development of magnetostatic models most easily proceeds from the derivation of scalar potentials of separate geometric elements. These potentials can then be conbined at will because of the superposition characteristic of conservative force fields.


Author(s):  
J W Steeds ◽  
R Vincent

We review the analytical powers which will become more widely available as medium voltage (200-300kV) TEMs with facilities for CBED on a nanometre scale come onto the market. Of course, high performance cold field emission STEMs have now been in operation for about twenty years, but it is only in relatively few laboratories that special modification has permitted the performance of CBED experiments. Most notable amongst these pioneering projects is the work in Arizona by Cowley and Spence and, more recently, that in Cambridge by Rodenburg and McMullan.There are a large number of potential advantages of a high intensity, small diameter, focussed probe. We discuss first the advantages for probes larger than the projected unit cell of the crystal under investigation. In this situation we are able to perform CBED on local regions of good crystallinity. Zone axis patterns often contain information which is very sensitive to thickness changes as small as 5nm. In conventional CBED, with a lOnm source, it is very likely that the information will be degraded by thickness averaging within the illuminated area.


Author(s):  
Klaus-Ruediger Peters

A new generation of high performance field emission scanning electron microscopes (FSEM) is now commercially available (JEOL 890, Hitachi S 900, ISI OS 130-F) characterized by an "in lens" position of the specimen where probe diameters are reduced and signal collection improved. Additionally, low voltage operation is extended to 1 kV. Compared to the first generation of FSEM (JE0L JSM 30, Hitachi S 800), which utilized a specimen position below the final lens, specimen size had to be reduced but useful magnification could be impressively increased in both low (1-4 kV) and high (5-40 kV) voltage operation, i.e. from 50,000 to 200,000 and 250,000 to 1,000,000 x respectively.At high accelerating voltage and magnification, contrasts on biological specimens are well characterized1 and are produced by the entering probe electrons in the outmost surface layer within -vl nm depth. Backscattered electrons produce only a background signal. Under these conditions (FIG. 1) image quality is similar to conventional TEM (FIG. 2) and only limited at magnifications >1,000,000 x by probe size (0.5 nm) or non-localization effects (%0.5 nm).


Author(s):  
G.K.W. Balkau ◽  
E. Bez ◽  
J.L. Farrant

The earliest account of the contamination of electron microscope specimens by the deposition of carbonaceous material during electron irradiation was published in 1947 by Watson who was then working in Canada. It was soon established that this carbonaceous material is formed from organic vapours, and it is now recognized that the principal source is the oil-sealed rotary pumps which provide the backing vacuum. It has been shown that the organic vapours consist of low molecular weight fragments of oil molecules which have been degraded at hot spots produced by friction between the vanes and the surfaces on which they slide. As satisfactory oil-free pumps are unavailable, it is standard electron microscope practice to reduce the partial pressure of organic vapours in the microscope in the vicinity of the specimen by using liquid-nitrogen cooled anti-contamination devices. Traps of this type are sufficient to reduce the contamination rate to about 0.1 Å per min, which is tolerable for many investigations.


Sign in / Sign up

Export Citation Format

Share Document