A New Approach for Characterizing the Energetic Magnetic Behavior of Fe-9Cr Steel Under Transient Conditions

2012 ◽  
Vol 61 (12) ◽  
pp. 3273-3279 ◽  
Author(s):  
Mirko Marracci ◽  
Bernardo Tellini ◽  
Ivan Alessio Maione
Open Physics ◽  
2018 ◽  
Vol 16 (1) ◽  
pp. 266-270 ◽  
Author(s):  
Roman Gozdur ◽  
Piotr Gębara ◽  
Krzysztof Chwastek

Abstract The paper presents a new approach to modeling of magnetic properties and the influence of temperature on hysteresis loops in La(FeCoSi)13 magnetocaloric compound. The GRUCAD hysteresis model has been used for analysis of magnetic behavior in the vicinity of the magnetic phase transition. The modeling results are in a qualitative agreement with experiment.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4337
Author(s):  
Sadeeshvara Udayanga Silva Thotabaddadurage ◽  
Nihal Kularatna ◽  
D. Alistair Steyn-Ross

SCASA is a patented technique commercialized as a surge protector device (SPD) that adheres to UL-1449 test standards. Apart from the novel use of supercapacitors, SCASA design incorporates a coupled-inductor wound to a specially selected magnetic material of powdered-iron. In this study, we investigate the limitations of the present design under transient operation and elucidate ways to eliminate them with the use of air-gapped ferrite cores. In modelling the operation under 50 Hz AC and transient conditions, a permeance-based approach is used; in addition, non-ideal characteristics of the transformer core are emphasized and discussed with empirical validations. The experimental work was facilitated using a lightning surge simulator coupled with the 230 V AC utility mains; combinational surge-waveforms (6 kV/3 kA) defined by IEEE C62.41 standards were continuously injected into SPD prototypes during destructive testing. Such procedures substantiate the overall surge-endurance capabilities of the different core types under testing. With regard to optimizations, we validated a 95% depletion of a negative-surge effect that would otherwise pass to the load-end, and another 13–16% reduction of the clamping voltage verified the effectiveness of the methods undertaken. In conclusion, SCASA prototypes that utilized air-gapped cores revealed a greater surge endurance with improved load-end characteristics.


1999 ◽  
Vol 173 ◽  
pp. 185-188
Author(s):  
Gy. Szabó ◽  
K. Sárneczky ◽  
L.L. Kiss

AbstractA widely used tool in studying quasi-monoperiodic processes is the O–C diagram. This paper deals with the application of this diagram in minor planet studies. The main difference between our approach and the classical O–C diagram is that we transform the epoch (=time) dependence into the geocentric longitude domain. We outline a rotation modelling using this modified O–C and illustrate the abilities with detailed error analysis. The primary assumption, that the monotonity and the shape of this diagram is (almost) independent of the geometry of the asteroids is discussed and tested. The monotonity enables an unambiguous distinction between the prograde and retrograde rotation, thus the four-fold (or in some cases the two-fold) ambiguities can be avoided. This turned out to be the main advantage of the O–C examination. As an extension to the theoretical work, we present some preliminary results on 1727 Mette based on new CCD observations.


Author(s):  
V. Mizuhira ◽  
Y. Futaesaku

Previously we reported that tannic acid is a very effective fixative for proteins including polypeptides. Especially, in the cross section of microtubules, thirteen submits in A-tubule and eleven in B-tubule could be observed very clearly. An elastic fiber could be demonstrated very clearly, as an electron opaque, homogeneous fiber. However, tannic acid did not penetrate into the deep portion of the tissue-block. So we tried Catechin. This shows almost the same chemical natures as that of proteins, as tannic acid. Moreover, we thought that catechin should have two active-reaction sites, one is phenol,and the other is catechole. Catechole site should react with osmium, to make Os- black. Phenol-site should react with peroxidase existing perhydroxide.


Author(s):  
N. Qiu ◽  
J. E. Wittig

PtCo hard magnets have specialized applications owing to their relatively high coercivity combined with corrosion resistance and ductility. Increased intrinsic coercivity has been recently obtained by rapid solidification processing of PtCo alloys containing boron. After rapid solidification by double anvil splat quenching and subsequent annealing for 30 minutes at 650°C, an alloy with composition Pt42Co45B13 (at.%) exhibited intrinsic coercivity up to 14kOe. This represents a significant improvement compared to the average coercivities in conventional binary PtCo alloys of 5 to 8 kOe.Rapidly solidified specimens of Pt42Co45B13 (at.%) were annealed at 650°C and 800°C for 30 minutes. The magnetic behavior was characterized by measuring the coercive force (Hc). Samples for TEM analysis were mechanically thinned to 100 μm, dimpled to about 30 nm, and ion milled to electron transparency in a Gatan Duomill at 5 kV and 1 mA gun current. The incident ion beam angle was set at 15° and the samples were liquid nitrogen cooled during milling. These samples were analyzed with a Philips CM20T TEM/STEM operated at 200 kV.


Author(s):  
K. Chien ◽  
R. Van de Velde ◽  
I.P. Shintaku ◽  
A.F. Sassoon

Immunoelectron microscopy of neoplastic lymphoma cells is valuable for precise localization of surface antigens and identification of cell types. We have developed a new approach in which the immunohistochemical staining can be evaluated prior to embedding for EM and desired area subsequently selected for ultrathin sectioning.A freshly prepared lymphoma cell suspension is spun onto polylysine hydrobromide- coated glass slides by cytocentrifugation and immediately fixed without air drying in polylysine paraformaldehyde (PLP) fixative. After rinsing in PBS, slides are stained by a 3-step immunoperoxidase method. Cell monolayer is then fixed in buffered 3% glutaraldehyde prior to DAB reaction. After the DAB reaction step, wet monolayers can be examined under LM for presence of brown reaction product and selected monolayers then processed by routine methods for EM and embedded with the Chien Re-embedding Mold. After the polymerization, the epoxy blocks are easily separated from the glass slides by heatingon a 100°C hot plate for 20 seconds.


Author(s):  
W. A. Chiou ◽  
N. Kohyama ◽  
B. Little ◽  
P. Wagner ◽  
M. Meshii

The corrosion of copper and copper alloys in a marine environment is of great concern because of their widespread use in heat exchangers and steam condensers in which natural seawater is the coolant. It has become increasingly evident that microorganisms play an important role in the corrosion of a number of metals and alloys under a variety of environments. For the past 15 years the use of SEM has proven to be useful in studying biofilms and spatial relationships between bacteria and localized corrosion of metals. Little information, however, has been obtained using TEM capitalizing on its higher spacial resolution and the transmission observation of interfaces. The research presented herein is the first step of this new approach in studying the corrosion with biological influence in pure copper.Commercially produced copper (Cu, 99%) foils of approximately 120 μm thick exposed to a copper-tolerant marine bacterium, Oceanospirillum, and an abiotic culture medium were subsampled (1 cm × 1 cm) for this study along with unexposed control samples.


Author(s):  
Arthur V. Jones

With the introduction of field-emission sources and “immersion-type” objective lenses, the resolution obtainable with modern scanning electron microscopes is approaching that obtainable in STEM and TEM-but only with specific types of specimens. Bulk specimens still suffer from the restrictions imposed by internal scattering and the need to be conducting. Advances in coating techniques have largely overcome these problems but for a sizeable body of specimens, the restrictions imposed by coating are unacceptable.For such specimens, low voltage operation, with its low beam penetration and freedom from charging artifacts, is the method of choice.Unfortunately the technical dificulties in producing an electron beam sufficiently small and of sufficient intensity are considerably greater at low beam energies — so much so that a radical reevaluation of convential design concepts is needed.The probe diameter is usually given by


1968 ◽  
Vol 32 (3) ◽  
pp. 279-282
Author(s):  
JI Mock ◽  
JW Grenfell ◽  
WA Richter
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document