Correlation of Patellar Tracking Pattern With Trochlear and Retropatellar Surface Topographies

2000 ◽  
Vol 122 (6) ◽  
pp. 652-660 ◽  
Author(s):  
A. M. Ahmed ◽  
N. A. Duncan

The study was aimed to test the hypothesis that in the knee extension range 100 to 30 deg, the patellar “out-of-plane” tracking pattern is controlled by the passive restraint provided by the topographic interaction of the patellofemoral contacting surfaces. The out-of-plane tracking pattern, i.e., the pattern of patellar displacements not in the plane of knee extension/flexion, consists of translation in the medial–lateral direction, and rotations about the anterior–posterior axis (spin) and the proximal–distal axis (tilt). Using 15 fresh-frozen knees subjected to extensor moment magnitudes comparable to those in the “static-lifting” activity (foot-ground reaction=334 N), the patellar displacements were measured using a calibrated six-degree-of-freedom electromechanical goniometer. The topographies of the trochlear and retropatellar surfaces were then measured using a calibrated traveling dial-gage arrangement and the same coordinate system used for the displacement measurements. Three indices were defined to quantify particular natural features of the three-dimensional topographies that are expected to control the patellar displacements. Correlation of the indices with their corresponding displacements showed that topographic interaction was significant in the control of all three displacements. However, for patellar spin, unlike for the other two displacements, the direction of the active quadriceps tension vector was also a significant controlling factor. Patellar medial–lateral translation was found to be controlled dominantly by the trochlear topography, while retropatellar topography also had a significant role in the control of the other two displacements. [S0148-0731(00)01406-0]

1999 ◽  
Vol 121 (2) ◽  
pp. 222-228 ◽  
Author(s):  
A. M. Ahmed ◽  
N. A. Duncan ◽  
M. Tanzer

This study sought to determine whether a general pattern describing the three-dimensional tracking characteristics of the human patella could be established, and if not, then to determine the extent and nature of interspecimen variations in the characteristics in a normal population. Using 32 fresh-frozen knees subjected to extensor moment magnitudes similar to those in “static-lifting” and “leg-raising against resistance” maneuvers, patellar displacements were measured in the knee extension range 120 to 0 deg. For static-lifting, a constant foot-floor reaction of 334 N was applied. For leg-raising, a constant net quadriceps tension of 668 N was used throughout the extension range. Measurements were taken with a calibrated six-degree-of-freedom electromechanical goniometer and a displacement coordinate system referenced to the geometry of individual specinens. The three patellar displacements in the plane of knee extension/flexion (extension rotation, and anterior and proximal translations) consistently demonstrated the same pattern in the entire knee extension range with an average coefficient of variation of 13 percent. For knee angles greater than 45 deg, the three other displacements (medial lateral translation, and rotations about the anterior–posterior and proximal–distal axes) followed a general pattern. However, for knee angles less than 45 deg, these displacements differed considerably between specimens for each loading condition, both in terms of magnitude (average coefficient of variation: 70 percent), and direction.


2020 ◽  
Vol 117 (35) ◽  
pp. 21070-21078
Author(s):  
Yusuke Hibi ◽  
Yuki Oguchi ◽  
Yuta Shimizu ◽  
Kayoko Hashimoto ◽  
Katsuya Kondo ◽  
...  

In-plane mesopatterns derived from block-copolymer (BCP) micro-phase segregation in thin films have attracted much interest in practical applications as well as fundamental research programs. However, phase segregation along the film-normal direction has been less studied. Here, we describe a strategy to concurrently, yet independently, control in-plane micro-phase and out-of-plane macro-phase segregation in multiblended films composed of liquid-crystalline BCPs (LCBCPs), affording spontaneously layered three-dimensional (3D) mesostructures. This strategy relies on sequential liquid crystallization during the cooling process in thermal annealing as follows. The constituent LCBCP with the highest isotropic-transition temperature (Tiso) first liquid-crystallizes and segregates from the other LCBCP mixture remaining in isotropic states to form a noncontaminated layer at the top surface. This preformed LCBCP layer preserves its inherent in-plane pattern and acts as a template guiding the subsequent micro-phase segregations of the other low-TisoLCBCPs underneath. This self-template–assisted micro-phase segregation (STAMPS) readily provides 3D mesostructures, the potential toward rational material design of which is also demonstrated in water-separation applications.


Author(s):  
J.L. Carrascosa ◽  
G. Abella ◽  
S. Marco ◽  
M. Muyal ◽  
J.M. Carazo

Chaperonins are a class of proteins characterized by their role as morphogenetic factors. They trantsiently interact with the structural components of certain biological aggregates (viruses, enzymes etc), promoting their correct folding, assembly and, eventually transport. The groEL factor from E. coli is a conspicuous member of the chaperonins, as it promotes the assembly and morphogenesis of bacterial oligomers and/viral structures.We have studied groEL-like factors from two different bacteria:E. coli and B.subtilis. These factors share common morphological features , showing two different views: one is 6-fold, while the other shows 7 morphological units. There is also a correlation between the presence of a dominant 6-fold view and the fact of both bacteria been grown at low temperature (32°C), while the 7-fold is the main view at higher temperatures (42°C). As the two-dimensional projections of groEL were difficult to interprete, we studied their three-dimensional reconstruction by the random conical tilt series method from negatively stained particles.


2019 ◽  
Vol 63 (5) ◽  
pp. 50401-1-50401-7 ◽  
Author(s):  
Jing Chen ◽  
Jie Liao ◽  
Huanqiang Zeng ◽  
Canhui Cai ◽  
Kai-Kuang Ma

Abstract For a robust three-dimensional video transmission through error prone channels, an efficient multiple description coding for multi-view video based on the correlation of spatial polyphase transformed subsequences (CSPT_MDC_MVC) is proposed in this article. The input multi-view video sequence is first separated into four subsequences by spatial polyphase transform and then grouped into two descriptions. With the correlation of macroblocks in corresponding subsequence positions, these subsequences should not be coded in completely the same way. In each description, one subsequence is directly coded by the Joint Multi-view Video Coding (JMVC) encoder and the other subsequence is classified into four sets. According to the classification, the indirectly coding subsequence selectively employed the prediction mode and the prediction vector of the counter directly coding subsequence, which reduces the bitrate consumption and the coding complexity of multiple description coding for multi-view video. On the decoder side, the gradient-based directional interpolation is employed to improve the side reconstructed quality. The effectiveness and robustness of the proposed algorithm is verified by experiments in the JMVC coding platform.


2019 ◽  
Vol 14 (1) ◽  
Author(s):  
Wu-zhou Li ◽  
Zhi-wen Liang ◽  
Yi Cao ◽  
Ting-ting Cao ◽  
Hong Quan ◽  
...  

Abstract Background Tumor motion may compromise the accuracy of liver stereotactic radiotherapy. In order to carry out a precise planning, estimating liver tumor motion during radiotherapy has received a lot of attention. Previous approach may have difficult to deal with image data corrupted by noise. The iterative closest point (ICP) algorithm is widely used for estimating the rigid registration of three-dimensional point sets when these data were dense or corrupted. In the light of this, our study estimated the three-dimensional (3D) rigid motion of liver tumors during stereotactic liver radiotherapy using reconstructed 3D coordinates of fiducials based on the ICP algorithm. Methods Four hundred ninety-five pairs of orthogonal kilovoltage (KV) images from the CyberKnife stereo imaging system for 12 patients were used in this study. For each pair of images, the 3D coordinates of fiducial markers inside the liver were calculated via geometric derivations. The 3D coordinates were used to calculate the real-time translational and rotational motion of liver tumors around three axes via an ICP algorithm. The residual error was also investigated both with and without rotational correction. Results The translational shifts of liver tumors in left-right (LR), anterior-posterior (AP),and superior-inferior (SI) directions were 2.92 ± 1.98 mm, 5.54 ± 3.12 mm, and 16.22 ± 5.86 mm, respectively; the rotational angles in left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions were 3.95° ± 3.08°, 4.93° ± 2.90°, and 4.09° ± 1.99°, respectively. Rotational correction decreased 3D fiducial displacement from 1.19 ± 0.35 mm to 0.65 ± 0.24 mm (P<0.001). Conclusions The maximum translational movement occurred in the SI direction. Rotational correction decreased fiducial displacements and increased tumor tracking accuracy.


Author(s):  
Mohamed Alkoheji ◽  
Hadi El-Daou ◽  
Jillian Lee ◽  
Adrian Carlos ◽  
Livio Di Mascio ◽  
...  

Abstract Purpose Persistent acromioclavicular joint (ACJ) instability following high grade injuries causes significant symptoms. The importance of horizontal plane stability is increasingly recognised. There is little evidence of the ability of current implant methods to restore native ACJ stability in the vertical and horizontal planes. The purpose of this work was to measure the ability of three implant reconstructions to restore native ACJ stability. Methods Three groups of nine fresh-frozen shoulders each were mounted into a robotic testing system. The scapula was stationary and the robot displaced the clavicle to measure native anterior, posterior, superior and inferior (A, P, S, I) stability at 50 N force. The ACJ capsule, conoid and trapezoid ligaments were transected and the ACJ was reconstructed using one of three commercially available systems. Two systems (tape loop + screw and tape loop + button) wrapped a tape around the clavicle and coracoid, the third system (sutures + buttons) passed directly through tunnels in the clavicle and coracoid. The stabilities were remeasured. The data for A, P, S, I stability and ranges of A–P and S–I stability were analyzed by ANOVA and repeated-measures Student t tests with Bonferroni correction, to contrast each reconstruction stability versus the native ACJ data for that set of nine specimens, and examined contrasts among the reconstructions. Results All three reconstructions restored the range of A–P stability to that of the native ACJ. However, the coracoid loop devices shifted the clavicle anteriorly. For S–I stability, only the sutures + buttons reconstruction did not differ significantly from native ligament restraint. Conclusions Only the sutures + buttons reconstruction, that passed directly through tunnels in the clavicle and coracoid, restored all stability measures (A, P, S, I) to the native values, while the tape implants wrapped around the bones anteriorised the clavicle. These findings show differing abilities among reconstructions to restore native stability in horizontal and vertical planes. (300 words)


Author(s):  
Olivier Ozenda ◽  
Epifanio G. Virga

AbstractThe Kirchhoff-Love hypothesis expresses a kinematic constraint that is assumed to be valid for the deformations of a three-dimensional body when one of its dimensions is much smaller than the other two, as is the case for plates. This hypothesis has a long history checkered with the vicissitudes of life: even its paternity has been questioned, and recent rigorous dimension-reduction tools (based on standard $\varGamma $ Γ -convergence) have proven to be incompatible with it. We find that an appropriately revised version of the Kirchhoff-Love hypothesis is a valuable means to derive a two-dimensional variational model for elastic plates from a three-dimensional nonlinear free-energy functional. The bending energies thus obtained for a number of materials also show to contain measures of stretching of the plate’s mid surface (alongside the expected measures of bending). The incompatibility with standard $\varGamma $ Γ -convergence also appears to be removed in the cases where contact with that method and ours can be made.


Work ◽  
2021 ◽  
Vol 68 (s1) ◽  
pp. S151-S159
Author(s):  
Zhihui Liu ◽  
T. Rotte ◽  
S. Anjani ◽  
P. Vink

BACKGROUND: Staggered seats are a solution for the Flying-V aircraft, where the cabin’s longitudinal axis has a 26 degrees angle with respect to the direction of flight, to compensate for an otherwise oblique sitting position. However, little is known on acceptable pitches in this staggered configuration. OBJECTIVE: The goal of this research is to evaluate the comfort of different pitches for seats that are staggered relative to the cabin’s longitudinal axis. METHODS: Two rows of staggered seats are positioned at three different pitches (27, 29 and 31 inches). 53 participants were seated in each setup. For each, a questionnaire was completed including questions on comfort and discomfort, top view photos were taken to analyse postures and physical dimensions were recorded to define passengers’ space. RESULTS: Comfort as well as discomfort were significantly different for the three setups. The comfort at 27 inches was seen as unacceptably low. The 29 and 31-inch configurations showed to result in acceptable levels of comfort, comparable to higher-end seating layouts. There were very little complaints about space in lateral direction (elbow and seat width), showing the advantage of having your won armrest and shoulder space in the staggered configuration. Interesting was that at larger pitches more complaints were found for the seat characteristics, probably in the shorter pitch the other discomfort was overruling this. CONCLUSION: The 26-degree staggered configuration offers improvements in shoulder- and elbow-space. The results for the 29- and 31-inch are expected to allow enough design freedom for further exploration of such a configuration for the Flying-V cabin interior.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Zhe Li ◽  
Guanzhi Liu ◽  
Run Tian ◽  
Ning Kong ◽  
Yue Li ◽  
...  

Abstract Background Our objective was to obtain normal patellofemoral measurements to analyse sex and individual differences. In addition, the absolute values and indices of tibial tuberosity-trochlear groove (TT-TG) distances are still controversial in clinical application. A better method to enable precise prediction is still needed. Methods Seventy-eight knees of 78 participants without knee pathologies were included in this cross-sectional study. A CT scan was conducted for all participants and three-dimensional knee models were constructed using Mimics and SolidWorks software. We measured and analysed 19 parameters including the TT-TG distance and dimensions and shapes of the patella, femur, tibia, and trochlea. LASSO regression was used to predict the normal TT-TG distances. Results The dimensional parameters, TT-TG distance, and femoral aspect ratio of the men were significantly larger than those of women (all p values < 0.05). However, after controlling for the bias from age, height, and weight, there were no significant differences in TT-TG distances and anterior-posterior dimensions between the sexes (all p values > 0.05). The Pearson correlation coefficients between the anterior femoral offset and other indexes were consistently below 0.3, indicating no relationship or a weak relationship. Similar results were observed for the sulcus angle and the Wiberg index. Using LASSO regression, we obtained four parameters to predict the TT-TG distance (R2 = 0.5612, p < 0.01) to achieve the optimal accuracy and convenience. Conclusions Normative data of patellofemoral morphology were provided for the Chinese population. The anterior-posterior dimensions of the women were thicker than those of men for the same medial-lateral dimensions. More attention should be paid to not only sex differences but also individual differences, especially the anterior condyle and trochlea. In addition, this study provided a new method to predict TT-TG distances accurately.


Author(s):  
H Geramizadeh ◽  
S Dariushi ◽  
S Jedari Salami

The current study focuses on designing the optimal three-dimensional printed sandwich structures. The main goal is to improve the energy absorption capacity of the out-of-plane honeycomb sandwich beam. The novel Beta VI and Alpha VI were designed in order to achieve this aim. In the Beta VI, the connecting curves (splines) were used instead of the four diagonal walls, while the two vertical walls remained unchanged. The Alpha VI is a step forward on the Beta VI, which was promoted by filleting all angles among the vertical walls, created arcs, and face sheets. The two offered sandwich structures have not hitherto been provided in the literature. All models were designed and simulated by the CATIA and ABAQUS, respectively. The three-dimensional printer fabricated the samples by fused deposition modeling technique. The material properties were determined under tensile, compression, and three-point bending tests. The results are carried out by two methods based on experimental tests and finite element analyses that confirmed each other. The achievements provide novel insights into the determination of the adequate number of unit cells and demonstrate the energy absorption capacity of the Beta VI and Alpha VI are 23.7% and 53.9%, respectively, higher than the out-of-plane honeycomb sandwich structures.


Sign in / Sign up

Export Citation Format

Share Document