Improving Performance of Refrigerant Cooled Steam Power Plant by Using Cooling Thermal Storage

Author(s):  
A. S. Hegazy

It is proposed in the current paper to combine the steam plant with two refrigeration cycles and a cooling storage container. Throughout the time of a day, the steam plant is made to work at full power, where the excess power generated over the electric power demand is used to drive the compressors of the refrigeration cycles. The stored cooling is used for dissipating the heat absorbed by the cooling refrigerant in the steam condenser during the period of peak-loads, while the two refrigeration machines are stopped. In this way, the energy used for driving the refrigeration machine is saved so that the whole power generated by the steam plant is exported to the grid. Energy analyses of the proposed combined system has led to inferring that the net power of the steam plant during the period of exclusive direct cooling of the steam condenser (only the first refrigeration machine is running) is about 70–86% of the whole power generated by the steam plant when the coefficient of performance of the first refrigeration cycle lies in the range of 4–10. Also, it has been found that relatively small coefficients of performance of the first and second cycles, less than 6 and 1.5, respectively, result in low net power of the steam plant over the period of charging the cooling storage container (both refrigeration machines run in unison). In this case, the net plant power amounts to less than 26% of the total generated plant power when the time of storing the cooling is lower than double the time of the peak-loads. This necessitates increasing the storing time to assure reasonable available power to be exported to the grid. Economical analyses of the proposed system have showed that both the capital cost and energy charges are less for the proposed system than that of the steam plant without cooling storage for practically possible operating conditions.

Energies ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 498
Author(s):  
Anis Idir ◽  
Maxime Perier-Muzet ◽  
David Aymé-Perrot ◽  
Driss Stitou

In the present study, the evaluation of potential improvement of the overall efficiency of a common PV panel, valorizing the heat extracted by a heat exchanger that is integrated on its back side, either into work using an endoreversible Carnot engine or into cold by using an endoreversible tri-thermal machine consisting of a heat-driven refrigeration machine operating between three temperature sources and sink (such as a liquid/gas absorption machine), was carried out. A simplified thermodynamic analysis of the PV/thermal collector shows that there are two optimal operating temperatures and of the panels, which maximize either the thermal exergy or the overall exergy of the PV panel, respectively. The cold produced by the endoreversible tri-thermal machine during the operating conditions of the PV/thermal collector at is higher with a coefficient of performance (COP) of 0.24 thanks to the higher heat recovery potential. In the case of using the cold produced by a tri-thermal machine to actively cool of an additional PV panel in order to increase its electrical performances, the operating conditions at the optimal temperature provide a larger and more stable gain: the gain is about 12.2% compared with the conventional PV panel when the operating temperature of the second cooled panel varies from 15 to 35 °C.


2012 ◽  
Vol 622-623 ◽  
pp. 489-493
Author(s):  
Iskander Beisembetov ◽  
Sabyi Ussupov ◽  
Bakhyt Absadykov ◽  
Beken Arymbekov ◽  
Birzhan Bektibay

Development relevance to improve the operational parameters of the support units of machine tools in their design elements is introduced that increase the rigidity of the components, their carrying capacity, damp occurring vibrations in the process, the coefficient of performance (COP), smoothness of motion, positioning accuracy, reducing the wear of their working surfaces and maintain the original accuracy. A number of engineering development [1], [2], aimed at improving the above characteristics of the machine by changing and improving design of reference nodes used in these rails rolling bearings, aerostatic and hydrostatic guides, as well as the use of automatic control systems of its basic parameters, determine its quality. However, in some operating conditions in which errors occur, mainly due to the instability of oil-film thickness (gap) between the mobile and immobile elements of the hydrostatic bearing. For high accuracy requirements it will negatively affect the quality of machined parts and equipment performance. On this basis, it becomes apparent urgency of the problem of automatic stabilization of oil-film thickness (gap) in the IR. To ensure high precision equipment to improve power system hydrostatic bearing units of machine tools. This, in turn, creates the prerequisite for the development of stabilization systems of the gap in the hydrostatic bearing, with the help of which the thickness of oil layer in them would be kept constant even with significant dynamic load on the support.


2020 ◽  
Vol 8 (2) ◽  
pp. 3-9
Author(s):  
E.A. Belyanovskaya ◽  
◽  
G.M. Pustovoy ◽  
A.I. Sklyarenko ◽  
M.P. Sukhyy ◽  
...  

The work is focused on the development of an effective algorithm for calculating the operational characteristics of a steamcompressive chilling machine with an adsorptive chilling unit, which involves a cold box, an adsorber, an evaporator and a condenser, water being used as a refrigerant. An algorithm for calculating the operating parameters of the adsorptive chilling unit has been developed, which includes the determination of the cooling capacity of the steam compressor refrigeration unit, the heat load on the condenser, the power consumed by the compressor, the coefficient of performance of the steam compressor refrigeration unit, as well as the calculation of the mass of water, the mass of the adsorbent, the refrigerating capacity, the coefficient of performance of the adsorptive chilling unit and the coefficient of useful energy utilization of a steam compressive chilling machine with an adsorption chilling unit. The chilling capacity and the coefficient of performance of the adsorption chilling unit are estimated under the operating conditions of a typical steam compression chilling machine. The crucial factors affecting the efficiency of the adsorptive chilling unit are analyzed. It has been established that the chilling capacity, the coefficient of performance of the adsorption refrigeration module and the energy efficiency of the installation are determined by the thermal load on the condenser, and, therefore, by the mass of water that is desorbed and evaporated. The coefficient of performance of the adsorption chilling unit and the efficiency of the steam compressor chilling machine with the adsorptive chilling unit are estimated to be 0.878 and 4.64. The criteria for the selection of adsorbents for the adsorption module are analyzed. The temperature of regeneration is determined by the temperatures in the condenser, and the limit adsorption affects the mass of the adsorbent and the size of the adsorber. A comparison of the efficiency of adsorptive chi l l ing uni t based on silicoaluminophosphates and composite adsorbents «silica gel – sodium acetate» is carried out. The prospects of using composites «silica gel – СН3СООNa» are shown. The optimal composition of the composite was established, which corresponds to the minimal size of the adsorber, (80% sodium acetate and 20% silica gel). The prospects of using adsorptive conversion of thermal energy for utilization of low-potential thermal energy during the operation of steam compressive chilling machine are shown. Keywords: adsorptive conversion of heat energy, composite adsorbent, steam compressive chilling unit, adsorption, adsorptive capacity.


Author(s):  
Дмитро Вікторович Коновалов ◽  
Роман Миколайович Радченко ◽  
Сергій Георгійович Фордуй ◽  
Фелікс Володимирович Царан ◽  
Віктор Павлович Халдобін ◽  
...  

One of the current directions of development of modern energy-saving and energy-efficient technologies for ship and stationery (including municipal) energy is the use of ejector refrigeration machines, which can be used for air conditioning systems together with an absorption refrigeration machine (cascade cycle) or vapor compressor refrigeration machine as part of cogeneration or trigeneration units. Such circuit solutions can be used together with ensuring the rational organization of work processes in the main elements of the refrigeration machine, in particular in the jet device - ejector, the appropriate design of which, in turn, will further increase the thermal coefficient. Improving the design of the ejector is a rather complex and long process and does not always give positive results. It is primarily because many tests are required on full-scale models. Therefore, computer simulation of the ejector operation at different variable input parameters, considering the geometric characteristics of the flow part and variable mode characteristics during operation is more attractive in terms of finding options for rational (optimal) design. The paper presents the results of software development for modeling hydrodynamic processes in the flowing part of the ejector, considering the variable operating modes of the ejector refrigeration machine. The existing method for calculating the pressure and circulation characteristics of jet devices is used. The developed software complex "RefJet" in the design mode defines the maximum achievable coefficients of ejection of a jet ejector. In the simulation mode - provides determination of the ejection coefficients of the already designed (certain sizes) ejector at variable values of pressure at the inlet and outlet in specific operating conditions, considering its operation at the limit and partial modes. The work of the software package was tested in the development and analysis of circuit solutions of ejector refrigeration machines as part of the heat recovery circuits of three-generation units based on internal combustion engines and gas turbine engines.


Author(s):  
Vikas Kumar ◽  
Gulshan Sachdeva ◽  
Sandeep Tiwari ◽  
Parinam Anuradha ◽  
Vaibhav Jain

A conventional vapor compression refrigeration system (VCRS) cascaded with a heat-assisted ejector refrigeration system (ERS) has been experimentally analyzed. Cascading allows the VCRS to operate at lower condenser temperatures and thus achieve a higher coefficient of performance. In this cascaded system, the condenser of the vapor compression system does not dissipate its heat directly to the evaporator of the ERS; instead, water circulates between the condenser of VCRS and the evaporator of ERS to exchange the heat. Seven ejectors of different geometries have been used in the ERS; however, all the ejectors could not maintain thermal equilibrium at the desired operating conditions. The compressor of the cascaded VCRS consumed 1.3 times less power than the noncascaded VCRS. Furthermore, the cascaded system provided a maximum 87.74% improvement in COP over the noncascaded system for the same operating conditions. The performance of the system remained constant until the critical condenser pressure of the ERS.


Energies ◽  
2020 ◽  
Vol 13 (12) ◽  
pp. 3198 ◽  
Author(s):  
Adil Al-Falahi ◽  
Falah Alobaid ◽  
Bernd Epple

Solar absorption cycles for air conditioning systems have recently attracted much attention. They have some important advantages that aid in reducing greenhouse gas emissions. In this work, design and thermo-economic analyses are presented in order to compare between two different collector types (parabolic trough and evacuated tube) by water–lithium bromide absorption systems, and to select the best operating conditions. Generally, the system consists of three major parts. The first part is the solar field for thermal power conversion. The second part is the intermediate cycle, which contains a flashing tank and pumping system. The third part is the water lithium bromide absorption chiller. A case study for a sports arena with 700–800 kW total cooling load is also presented. Results reveal that a parabolic trough collector combined with H2O–LiBr (PTC/H2O–LiBr) gives lower design aspects and minimum rates of hourly costs (USD 5.2/h), while ETC/H2O–LiBr configuration give USD 5.6/h. The H2O–LiBr thermo-economic product cost is USD 0.14/GJ. The cycle coefficient of performance COP was in the range of 0.5 to 0.9.


2020 ◽  
Vol 15 (3) ◽  
pp. 398-408
Author(s):  
I Ouelhazi ◽  
Y Ezzaalouni ◽  
L Kairouani

Abstract From the last few years, the use of efficient ejector in refrigeration systems has been paid a lot of attention. In this article a description of a refrigeration system that combines a basic vapor compression refrigeration cycle with an ejector cooling cycle is presented. A one-dimensional mathematical model is developed using the flow governing thermodynamic equations based on a constant area ejector flow model. The model includes effects of friction at the constant-area mixing chamber. The current model is based on the NIST-REFPROP database for refrigerant property calculations. The model has basically been used to determine the effect of the ejector geometry and operating conditions on the performance of the whole refrigeration system. The results show that the proposed model predicts ejector performance, entrainment ratio and the coefficient of performance of the system and their sensitivity to evaporating and generating temperature of the cascade refrigeration cycle. The simulated performance has been then compared with the available experimental data from the literature for validation.


Energies ◽  
2020 ◽  
Vol 13 (1) ◽  
pp. 200 ◽  
Author(s):  
Krzysztof Rajski ◽  
Jan Danielewicz ◽  
Ewa Brychcy

In the present work, the effects of different operating parameters on the performance of a gravity-assisted heat pipe-based indirect evaporative cooler (GAHP-based IEC) were investigated. The aim of the theoretical study is to evaluate accurately the cooling performance indicators, such as the coefficient of performance (COP), wet bulb effectiveness, and cooling capacity. To predict the effectiveness of the air cooler under a variety of conditions, the comprehensive calculation method was adopted. A mathematical model was developed to simulate numerically the heat and mass transfer processes. The mathematical model was validated adequately using experimental data from the literature. Based on the conducted numerical simulations, the most favorable ranges of operating conditions for the GAHP-based IEC were established. Moreover, the conducted studies could contribute to the further development of novel evaporative cooling systems employing gravity-assisted heat pipes as efficient equipment for transferring heat.


Author(s):  
Yahya I. Sharaf-Eldeen

This work involves measurements, analyses, and evaluation of performance of air-source heat pump water heaters (HPWHs), and their impacts on electric utility loads. Two add-on, heat pumps (HPs) rated at 7000 BTU/h (2.051 kW) and 12,000 BTU/h (3.517 kW) were utilized. The HPs were retrofitted to two 50 gal (189.3 l) electric water heaters (EWHs) with their electric heating elements removed. A third standard EWH was used for comparison. The testing setups were fully instrumented for measurements of all pertinent parameters, including inlet and outlet water temperatures, inlet and outlet air temperatures of the HPs, temperature and humidity of the surrounding air, volume of water drawn out of the storage tanks, as well as the electric energy consumptions of the systems. Performance measures evaluated included the coefficient of performance, the energy factor (EF), and the first hour rating (FHR). The HPWH systems gave EFs ranging from 1.8 to 2.5 and corresponding energy savings (and reductions in utility peak loads) ranging from 49.0% to 63.0%, approximately. The values obtained in the summer months were, as expected, somewhat higher than those obtained in the winter ones. The average values of the EFs and energy savings (and reductions in utility peak loads) were about 2.1 and 56.0%, respectively. FHR results were much lower for the HPWHs compared with those for the standard EWH. These results show that HPWHs are much more efficient compared with standard EWHs. While the average value of the EF for the EWH was about 0.92, the HPWHs yielded EFs averaging more than 2.00, resulting in annual energy savings averaging more than 50%. The results also show that HPWHs are effective at reducing utility peak loads, in addition to providing substantial cost savings to consumers.