scholarly journals Cooling Performance of Arrays of Vibrating Cantilevers

2009 ◽  
Vol 131 (11) ◽  
Author(s):  
Mark Kimber ◽  
Suresh V. Garimella

Piezoelectric fans are vibrating cantilevers actuated by a piezoelectric material and can provide heat transfer enhancement while consuming little power. Past research has focused on feasibility and performance characterization of a single fan, while arrays of such fans, which have important practical applications, have not been widely studied. This paper investigates the heat transfer achieved using arrays of cantilevers vibrating in their first resonant mode. This is accomplished by determining the local convection coefficients due to the two piezoelectric fans mounted near a constant heat flux surface using infrared thermal imaging. The heat transfer performance is quantified over a wide range of operating conditions, including vibration amplitude (7.5–10 mm), distance from heat source (0.01–2 times the fan amplitude), and pitch between fans (0.5–4 times the amplitude). The convection patterns observed are strongly dependent on the fan pitch, with the behavior resembling a single fan for small fan pitch and two isolated fans at a large pitch. The area-averaged thermal performance of the fan array is superior to that of a single fan, and correlations are developed to describe this enhancement in terms of the governing parameters. The best thermal performance is obtained when the fan pitch is 1.5 times its vibration amplitude.

Author(s):  
Piotr Łuczyński ◽  
Dennis Toebben ◽  
Manfred Wirsum ◽  
Wolfgang F. D. Mohr ◽  
Klaus Helbig

In recent decades, the rising share of commonly subsidized renewable energy especially affects the operational strategy of conventional power plants. In pursuit of flexibility improvements, extension of life cycle, in addition to a reduction in start-up time, General Electric has developed a product to warm-keep high/intermediate pressure steam turbines using hot air. In order to optimize the warm-keeping operation and to gain knowledge about the dominant heat transfer phenomena and flow structures, detailed numerical investigations are required. Considering specific warm-keeping operating conditions characterized by high turbulent flows, it is required to conduct calculations based on time-consuming unsteady conjugate heat transfer (CHT) simulations. In order to investigate the warm-keeping process as found in the presented research, single and multistage numerical turbine models were developed. Furthermore, an innovative calculation approach called the Equalized Timescales Method (ET) was applied for the modeling of unsteady conjugate heat transfer (CHT). The unsteady approach improves the accuracy of the stationary simulations and enables the determination of the multistage turbine models. In the course of the research, two particular input variables of the ET approach — speed up factor (SF) and time step (TS) — have been additionally investigated with regard to their high impact on the calculation time and the quality of the results. Using the ET method, the mass flow rate and the rotational speed were varied to generate a database of warm-keeping operating points. The main goal of this work is to provide a comprehensive knowledge of the flow field and heat transfer in a wide range of turbine warm-keeping operations and to characterize the flow patterns observed at these operating points. For varying values of flow coefficient and angle of incidence, the secondary flow phenomena change from well-known vortex systems occurring in design operation (such as passage, horseshoe and corner vortices) to effects typical for windage, like patterns of alternating vortices and strong backflows. Furthermore, the identified flow patterns have been compared to vortex systems described in cited literature and summarized in the so-called blade vortex diagram. The comparison of heat transfer in the form of charts showing the variation of the Nusselt-numbers with respect to changes in angle of incidence and flow coefficients at specific operating points is additionally provided.


2017 ◽  
Vol 10 (4) ◽  
pp. 362-379 ◽  
Author(s):  
Aswathy Surendran ◽  
Maria A Heckl ◽  
Naseh Hosseini ◽  
Omke Jan Teerling

One of the major concerns in the operability of power generation systems is their susceptibility to combustion instabilities. In this work, we explore whether a heat exchanger, an integral component of a domestic boiler, can be made to act as a passive controller that suppresses combustion instabilities. The combustor is modelled as a quarter-wave resonator (1-D, open at one end, closed at the other) with a compact heat source inside, which is modelled by a time-lag law. The heat exchanger is modelled as an array of tubes with bias flow and is placed near the closed end of the resonator, causing it to behave like a cavity-backed slit plate: an effective acoustic absorber. For simplicity and ease of analysis, we treat the physical processes of heat transfer and acoustic scattering occurring at the heat exchanger as two individual processes separated by an infinitesimal distance. The aeroacoustic response of the tube array is modelled using a quasi-steady approach and the heat transfer across the heat exchanger is modelled by assuming it to be a heat sink. Unsteady numerical simulations were carried out to obtain the heat exchanger transfer function, which is the response of the heat transfer at heat exchanger to upstream velocity perturbations. Combining the aeroacoustic response and the heat exchanger transfer function, in the limit of the distance between these processes tending to zero, gives the net influence of the heat exchanger. Other parameters of interest are the heat source location and the cavity length (the distance between the tube array and the closed end). We then construct stability maps for the first resonant mode of the aforementioned combustor configuration, for various parameter combinations. Our model predicts that stability can be achieved for a wide range of parameters.


1981 ◽  
Vol 103 (2) ◽  
pp. 218-225 ◽  
Author(s):  
E. M. Sparrow ◽  
S. Acharya

A conjugate conduction-convection analysis has been made for a vertical plate fin which exchanges heat with its fluid environment by natural convection. The analysis is based on a first-principles approach whereby the heat conduction equation for the fin is solved simultaneously with the conservation equations for mass, momentum, and energy in the fluid boundary layer adjacent to the fin. The natural convection heat transfer coefficient is not specified in advance but is one of the results of the numerical solutions. For a wide range of operating conditions, the local heat transfer coefficients were found not to decrease monotonically in the flow direction, as is usual. Rather, the coefficient decreased at first, attained a minimum, and then increased with increasing downstream distance. This behavior was attributed to an enhanced buoyancy resulting from an increase in the wall-to-fluid temperature difference along the streamwise direction. To supplement the first-principles analysis, results were also obtained from a simple adaptation of the conventional fin model.


Author(s):  
Jackson B. Marcinichen ◽  
John R. Thome ◽  
Raffaele L. Amalfi ◽  
Filippo Cataldo

Abstract Thermosyphon cooling systems represent the future of datacenter cooling, and electronics cooling in general, as they provide high thermal performance, reliability and energy efficiency, as well as capture the heat at high temperatures suitable for many heat reuse applications. On the other hand, the design of passive two-phase thermosyphons is extremely challenging because of the complex physics involved in the boiling and condensation processes; in particular, the most important challenge is to accurately predict the flow rate in the thermosyphon and thus the thermal performance. This paper presents an experimental validation to assess the predictive capabilities of JJ Cooling Innovation’s thermosyphon simulator against one independent data set that includes a wide range of operating conditions and system sizes, i.e. thermosyphon data for server-level cooling gathered at Nokia Bell Labs. Comparison between test data and simulated results show good agreement, confirming that the simulator accurately predicts heat transfer performance and pressure drops in each individual component of a thermosyphon cooling system (cold plate, riser, evaporator, downcomer (with no fitting parameters), and eventually a liquid accumulator) coupled with operational characteristics and flow regimes. In addition, the simulator is able to design a single loop thermosyphon (e.g. for cooling a single server’s processor), as shown in this study, but also able to model more complex cooling architectures, where many thermosyphons at server-level and rack-level have to operate in parallel (e.g. for cooling an entire server rack). This task will be performed as future work.


Energies ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1929 ◽  
Author(s):  
M. Sarafraz ◽  
Mohammad Safaei ◽  
Zhe Tian ◽  
Marjan Goodarzi ◽  
Enio Bandarra Filho ◽  
...  

In the present study, we report the results of the experiments conducted on the convective heat transfer of graphene nano-platelets dispersed in water-ethylene glycol. The graphene nano-suspension was employed as a coolant inside a micro-channel and heat-transfer coefficient (HTC) and pressure drop (PD) values of the system were reported at different operating conditions. The results demonstrated that the use of graphene nano-platelets can potentially augment the thermal conductivity of the working fluid by 32.1% (at wt. % = 0.3 at 60 °C). Likewise, GNP nano-suspension promoted the Brownian motion and thermophoresis effect, such that for the tests conducted within the mass fractions of 0.1%–0.3%, the HTC of the system was improved. However, a trade-off was identified between the PD value and the HTC. By assessing the thermal performance evaluation criteria (TPEC) of the system, it was identified that the thermal performance of the system increased by 21% despite a 12.1% augmentation in the PD value. Furthermore, with an increment in the fluid flow and heat-flux applied to the micro-channel, the HTC was augmented, showing the potential of the nano-suspension to be utilized in high heat-flux thermal applications.


2019 ◽  
Vol 141 (5) ◽  
Author(s):  
Ahmed T. Al-Sammarraie ◽  
Kambiz Vafai

The present investigation proposes an innovative convergent double pipe heat exchanger (C-DPHE). A two-dimensional (2D) axisymmetric heat transfer model with counterflow is employed to analyze the thermal and hydraulic performance of this configuration numerically. The impact of convergence in the flow direction, using a wide range of contraction ratio (Cr), is explored. The effect of Reynolds and Prandtl numbers on the flow and heat transfer is addressed, as well. The model results were validated with available data from the literature, and an excellent agreement has been confirmed. In general, the findings of the present study indicate that increasing the contraction ratio increases heat transfer and pressure drop in the C-DPHE. Moreover, this configuration has a prominent and sustainable performance, compared to a conventional double pipe heat exchanger (DPHE), with an enhancement in heat transfer rate up to 32% and performance factor (PF) higher than one. Another appealing merit for the C-DPHE is that it is quite effective and functional at low Reynolds and high Prandtl numbers, respectively, since no high-operating pumping power is required. Further, the optimal operating conditions can be established utilizing the comprehensive information provided in this work.


1983 ◽  
Vol 105 (3) ◽  
pp. 487-494 ◽  
Author(s):  
M. D. Rabinowitz ◽  
E. J. Hahn

Assuming central preloading, operation below the second bending critical speed, and full film lubrication, this paper presents a theoretical model which allows one, with minimum computation, to design squeeze film damped rotors under conditions of high unbalance loading. Closed form expressions are derived for the maximum vibration amplitudes pertaining to optimally damped conditions. The resulting vibration amplitude and transmissibility data of design interest are presented for a wide range of practical operating conditions on a single chart. It can be seen that for a given rotor, the lighter the bearing the more easily one can satisfy design constraints relating to allowable rotor vibration levels and lubricant supply pressure requirements. The data presented are shown to be applicable to a wide variety of rotors, and a recommended procedure for optimal design is outlined.


Author(s):  
Mohammad Ahmadi Bidakhvidi ◽  
Rasoul Shirzadeh ◽  
Steve Vanlanduit

Piezoelectric vibrating fans operating at resonance are a viable cooling technology due to its easy scalability and low power consumption. This study focuses on the characterization and optimization of the thermal performance of these miniature flapping cooling systems. Different experiments in a miniature windtunnel are conducted to investigate the cooling performance of the oscillating fans. The Strouhal number is a dimensionless parameter describing wing kinematics of flying systems. The aerodynamic propulsive efficiency of these systems is high over a narrow range of Strouhal numbers. Different St numbers were obtained and investigated, by changing the flow velocity of the win-tunnel. In practical applications different St could be obtained by combining conventional axial fans with piezoelectric fans. Both the feasibility of a single fan and array of fans is studied. For a wide range of operating coditions, including distance from heat source, dynamic tip deflection and orientation, the heat transfer performance of the piezoelectric fans is characterized.


2015 ◽  
Vol 787 ◽  
pp. 72-76 ◽  
Author(s):  
V. Naveen Prabhu ◽  
M. Suresh

Nanofluids are fluids containing nanometer-sized particles of metals, oxides, carbides, nitrides, or nanotubes. They exhibit enhanced thermal performance when used in a heat exchanger as heat transfer fluids. Alumina (Al2O3) is the most commonly used nanoparticle due to its enhanced thermal conductivity. The work presented here, deals with numerical simulations performed in a tube-in-tube heat exchanger to study and compare flow characteristics and thermal performance of a tube-in-tube heat exchanger using water and Al2O3/water nanofluid. A local element-by-element analysis utilizing e-NTU method is employed for simulating the heat exchanger. Profiles of hot and cooling fluid temperatures, pressure drop, heat transfer rate along the length of the heat exchanger are studied. Results show that heat exchanger with nanofluid gives improved heat transfer rate when compared with water. However, the pressure drop is more, which puts a limit on the operating conditions.


2012 ◽  
Vol 134 (8) ◽  
Author(s):  
Mehmet Arik ◽  
Tunc Icoz

Synthetic jets are piezo-driven, small-scale, pulsating devices capable of producing highly turbulent jets formed by periodic entrainment and expulsion of the fluid in which they are embedded. The compactness of these devices accompanied by high air velocities provides an exciting opportunity to significantly reduce the size of thermal management systems in electronic packages. A number of researchers have shown the implementations of synthetic jets on heat transfer applications; however, there exists no correlation to analytically predict the heat transfer coefficient for such applications. A closed form correlation was developed to predict the heat transfer coefficient as a function of jet geometry, position, and operating conditions for impinging flow based on experimental data. The proposed correlation was shown to predict the synthetic jet impingement heat transfer within 25% accuracy for a wide range of operating conditions and geometrical variables.


Sign in / Sign up

Export Citation Format

Share Document