Heat Transfer and Fluid Flow Analysis of Interrupted-Wall Channels, With Application to Heat Exchangers

1977 ◽  
Vol 99 (1) ◽  
pp. 4-11 ◽  
Author(s):  
E. M. Sparrow ◽  
B. R. Baliga ◽  
S. V. Patankar

An analysis has been made of laminar flow and heat transfer in channels whose walls are interrupted periodically along the streamwise direction. Such channels are frequently employed in high-performance compact heat exchangers. Numerical solutions of the mass, momentum, and energy conservation equations yielded local heat transfer and pressure drop results. These results were obtained for a range of Reynolds numbers and for several values of a dimensionless geometrical parameter characterizing the streamwise length L of the individual plate segments which make up the interrupted walls. The Prandtl number was fixed at 0.7 for all the calculations. The basic heat transfer and pressure drop results were employed to investigate whether an interrupted-wall channel experiences an augmented heat transfer rate compared with that for a parallel plate channel. For conditions of equal heat transfer surface area and equal pumping power, appreciably higher heat transfer rates prevailed in the interrupted-wall channel for a wide range of operating conditions. The augmentation was especially marked for relatively short channels and high Reynolds numbers. The results also demonstrated the existence of a new type of fully developed regime, one that is periodic. At sufficiently large downstream distances, the velocity and temperature profiles repeat their values at successive axial stations separated by a distance 2L and, in addition, the average heat transfer coefficient for a plate segment takes on a constant value.

Author(s):  
Patricia Streufert ◽  
Terry X. Yan ◽  
Mahdi G. Baygloo

Local turbulent convective heat transfer from a flat plate to a circular impinging air jet is numerically investigated. The jet-to-plate distance (L/D) effect on local heat transfer is the main focus of this study. The eddy viscosity V2F turbulence model is used with a nonuniform structured mesh. Reynolds-Averaged Navier-Stokes equations (RANS) and the energy equation are solved for axisymmetric, three-dimensional flow. The numerical solutions obtained are compared with published experimental data. Four jet-to-plate distances, (L/D = 2, 4, 6 and 10) and seven Reynolds numbers (Re = 7,000, 15,000, 23,000, 50,000, 70,000, 100,000 and 120,000) were parametrically studied. Local and average heat transfer results are analyzed and correlated with Reynolds number and the jet-to-plate distance. Results show that the numerical solutions matched experimental data best at low jet-to-plate distances and lower Reynolds numbers, decreasing in ability to accurately predict the heat transfer as jet-to-plate distance and Reynolds number was increased.


Author(s):  
Josua P. Meyer ◽  
Leon Liebenberg ◽  
Jonathan A. Olivier

Heat exchangers are usually designed in such a way that they do not operate in the transition region. This is usually due to a lack of information in this region. However, due to design constraints, energy efficiency requirements or change of operating conditions, heat exchangers are often forced to operate in this region. It is also well known that entrance disturbances influence where transition occurs. The purpose of this paper is to present experimental heat transfer and pressure drop data in the transition region for fully developed and developing flows inside smooth tubes using water as the working fluid. The use of different inlet disturbances were used to investigate its effect on transition. A tube-in-tube heat exchanger was used to perform the experiments, which ranged in Reynolds numbers from 1 000 to 20 000, with Prandtl numbers being between 4 and 6 while Grashof numbers were in the order of 105. Results showed that the type of inlet disturbance could delay transition to a Reynolds number as high as 7 000, while other inlets expedited it, confirming results of others. For heat transfer, though, it was found that transition was independent of the inlet disturbance and all commenced at the same Reynolds number, 2 000–3 000, which was attributed to secondary flow effects.


1981 ◽  
Vol 103 (2) ◽  
pp. 218-225 ◽  
Author(s):  
E. M. Sparrow ◽  
S. Acharya

A conjugate conduction-convection analysis has been made for a vertical plate fin which exchanges heat with its fluid environment by natural convection. The analysis is based on a first-principles approach whereby the heat conduction equation for the fin is solved simultaneously with the conservation equations for mass, momentum, and energy in the fluid boundary layer adjacent to the fin. The natural convection heat transfer coefficient is not specified in advance but is one of the results of the numerical solutions. For a wide range of operating conditions, the local heat transfer coefficients were found not to decrease monotonically in the flow direction, as is usual. Rather, the coefficient decreased at first, attained a minimum, and then increased with increasing downstream distance. This behavior was attributed to an enhanced buoyancy resulting from an increase in the wall-to-fluid temperature difference along the streamwise direction. To supplement the first-principles analysis, results were also obtained from a simple adaptation of the conventional fin model.


Author(s):  
Muzafar Hussain ◽  
Shahbaz Tahir

Abstract Nanofluids are widely adopted nowadays to enhance the heat transfer characteristics in the solar applications because of their excellent thermophysical properties. In this paper, a modified Eulerian-Eulerian model recently developed based on experiments was validated numerically to account for the deviations from the experimental data. The modified Eulerian-Eulerian model is compared with the single-phase model, Eulerian-Eulerian models for TiO2-water at different operating conditions and deviation from the experimental data for each of the model was documented. However, the modified Eulerian-Eulerian model gave much closer results when compared to the experimental data. For the further extension of work, the modified Eulerian-Eulerian model was applied to different nanofluids in order to investigate their heat transfer characteristics. Three different nanoparticles were investigated namely Cu, MgO, and Ag and their heat transfer characteristics is calculated based on the modified Eulerian-Eulerian model as well as the single-phase model for the comparison. For lower values of Reynolds numbers, the average heat transfer coefficient was almost identical for both models with small percentage of error but for higher Reynolds numbers, the deviation got larger. Therefore, single-phase model is not appropriate for higher Reynolds numbers and modified Eulerian-Eulerian model should be used to accurately predict the heat transfer characteristics of the nanofluids at higher Reynolds numbers. From the analysis it is found that the Ag-water nanofluid have the highest heat transfer characteristics among others and can be employed in the solar heat exchangers to enhance the heat transfer characteristics and to further improve the efficiency.


2003 ◽  
Vol 125 (4) ◽  
pp. 587-594 ◽  
Author(s):  
S. W. Moon ◽  
S. C. Lau

Experiments have been conducted to study steady heat transfer between two blockages with holes and pressure drop across the blockages, for turbulent flow in a rectangular channel. Average heat transfer coefficient and local heat transfer distribution on one of the channel walls between two blockages, and overall pressure drop across the blockages were obtained, for nine different staggered arrays of holes in the blockages and Reynolds numbers of 10,000 and 30,000. For the hole configurations studied, the blockages enhanced heat transfer by 4.6 to 8.1 times, but significantly increased the pressure drop. Smaller holes in the blockages caused higher heat transfer enhancement, but larger increase of the pressure drop than larger holes. The heat transfer enhancement was lower in the higher Reynolds number cases. Because of the large pressure drop, the heat transfer per unit pumping power was lower with the blockages than without the blockages. The local heat transfer was lower nearer the upstream blockage, the highest near the downstream blockage, and also relatively high in regions of reattachment of the jets leaving the upstream holes. The local heat transfer distribution was strongly dependent on the configuration of the hole array in the blockages. A third upstream blockage lowered both the heat transfer and the pressure drop, and significantly changed the local heat transfer distribution.


Energies ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 400
Author(s):  
Miftah Altwieb ◽  
Rakesh Mishra ◽  
Aliyu M. Aliyu ◽  
Krzysztof J. Kubiak

Multi-tube multi-fin heat exchangers are extensively used in various industries. In the current work, detailed experimental investigations were carried out to establish the flow/heat transfer characteristics in three distinct heat exchanger geometries. A novel perforated plain fin design was developed, and its performance was evaluated against standard plain and louvred fins designs. Experimental setups were designed, and the tests were carefully carried out which enabled quantification of the heat transfer and pressure drop characteristics. In the experiments the average velocity of air was varied in the range of 0.7 m/s to 4 m/s corresponding to Reynolds numbers of 600 to 2650. The water side flow rates in the tubes were kept at 0.12, 0.18, 0.24, 0.3, and 0.36 m3/h corresponding to Reynolds numbers between 6000 and 30,000. It was found that the louvred fins produced the highest heat transfer rate due to the availability of higher surface area, but it also produced the highest pressure drops. Conversely, while the new perforated design produced a slightly higher pressure drop than the plain fin design, it gave a higher value of heat transfer rate than the plain fin especially at the lower liquid flow rates. Specifically, the louvred fin gave consistently high pressure drops, up to 3 to 4 times more than the plain and perforated models at 4 m/s air flow, however, the heat transfer enhancement was only about 11% and 13% over the perforated and plain fin models, respectively. The mean heat transfer rate and pressure drops were used to calculate the Colburn and Fanning friction factors. Two novel semiempirical relationships were derived for the heat exchanger’s Fanning and Colburn factors as functions of the non-dimensional fin surface area and the Reynolds number. It was demonstrated that the Colburn and Fanning factors were predicted by the new correlations to within ±15% of the experiments.


Author(s):  
M. H. Saidi ◽  
A. A. Mozafari ◽  
A. R. Esmaeili Sany ◽  
J. Neyestani

In this Study, radiator performance for passenger car has been studied experimentally in wide range of operating conditions. Experimental prediction of Nusselt number and heat transfer coefficient for coolant in radiator tubes are also performed with ε–NTU method. The total effectiveness coefficient of radiator and heat transfer coefficient in air side is calculated via try and error method considering experimental data. The Colburn factor and pressure drop are also estimated for this heat exchanger. Examples of application demonstrate the practical usefulness of this method to provide empirical data which can be used during the design stage.


Author(s):  
Maung Naing Naing Tun ◽  
Nilufer Egrican

This paper presents computer software developed for rating and optimum selection of finned circular tubes compact heat exchangers with various coil geometries. The software is developed to use as a computing tool for commercial and R&D purposes in FRITERM A.S, an original equipment manufacturer (OEM) of finned tube heat exchangers. Finned-tube heat exchangers are highly utilized in refrigeration and process industries and heat transfer and pressure drop calculations are very important to manufactures and design engineers. For this purpose, a simulation and design software to predict the performance of finned-tube heat exchangers is presented. In finned-tube coils fin side fluid is air and tube side fluid can be water, oil, glycol water solution mixture and refrigerants. The analysis and rating of coils at dry and wet operating conditions are presented. Design and the most suitable selections of coils at the given parameters and design constraints from many different coil geometries are also performed in the software. User-friendly object-oriented programming C# is applied in developing the software. The software is developed in modular basic. Six modules are developed: Heating Coils, Cooling Coils, Condenser Coils, Steam Coils, Heat Recovery Coils and Evaporator (DX) Coils. REFPROP is also integrated in the software and all fluids’ thermal and transport properties are obtained from REFPROP. Heat transfer and pressure drop correlations available from literature are evaluated with recommendations. Simulated results are verified against experimental results.


2000 ◽  
Vol 124 (1) ◽  
pp. 133-139 ◽  
Author(s):  
K. Willenborg ◽  
V. Schramm ◽  
S. Kim ◽  
S. Wittig

The influence of a honeycomb facing on the heat transfer of a stepped labyrinth seal with geometry typical for modern jet engines was investigated. Heat transfer measurements were obtained for both a smooth stator and a stator lined with a honeycomb structure. In addition, an LDV system was used with the scaled up geometry to obtain a high local resolution of the velocity distribution in the seal. The experiments covered a wide range of pressure ratios and gap widths, typical for engine operating conditions. Local heat transfer coefficients were calculated from the measured wall and gas temperatures using a finite element code. By averaging the local values, mean heat transfer coefficients were determined and correlations for the global Nusselt numbers were derived for the stator and the rotor. The LDV results showed strong geometrical effects of the honeycomb structure on the development of the flow fields for the honeycomb seal. The distribution of the local heat transfer coefficients are compatible with the flow features identified by the LDV results and reveal a significantly reduced heat transfer with the honeycomb facing compared to the smooth facing.


2000 ◽  
Author(s):  
Man-Hoe Kim ◽  
Clark W. Bullard

Abstract An experimental study on the air-side heat transfer and pressure drop characteristics for multi-louvered fin and flat tube heat exchangers has been performed. For 45 heat exchangers with different louver angles (15–29°), fin pitches (1.0, 1.2, 1.4 mm) and flow depths (16, 20, 24 mm), a series of tests were conducted for the air-side Reynolds numbers of 100–600, at a constant tube-side water flow rate of 0.32 m3/h. The inlet temperatures of the air and water for heat exchangers were 21°C and 45°C, respectively. The air-side thermal performance data were analyzed using effectiveness-NTU method for cross-flow heat exchanger with both fluids unmixed. The heat transfer coefficient and pressure drop data for heat exchangers with different geometrical configurations were reported in terms of Colburn j-factor and Fanning friction factor f, as functions of Reynolds number based on louver pitch. Correlations for j and f factors are developed and compared to other correlations.