Techno-Economic Assessment of Gas Turbine Cogeneration Cycles Utilizing Anaerobic Digestion Products for Biogas Fuel

Author(s):  
Georgios Kontokostas ◽  
Ioannis Goulos

This work presents the development of an integrated approach for the techno-economic assessment of recuperated gas turbine cycles utilizing anaerobic digestion (AD) products of animal manure and energy crops for biogas fuel. The overall approach consists of a series of modeling methods applicable to AD and biogas fuel yield, thermodynamic evaluation of cogenerated gas turbine cycles, exergy analysis, and economic evaluation of powerplant operation. The developed method is applied for the techno-economic analysis of an AD plant yielding biogas fuel supplied to a recuperated gas turbine. The influence of gas turbine technology level on the economic sustainability of cogenerated powerplants powered by AD products is investigated. The obtained results suggest that the dominant cycle variables affecting the electrical performance of integrated digestion–cogeneration systems are the gas/air temperatures at the combustor outlet and recuperator air side (AS) exit, respectively. It is demonstrated that the profitability of the investment is highly dependent on electrical power output and the feed-in tariff used for electrical energy. It is argued that the desired split between electrical and thermal power output is dependent on the gas turbine technology level. It is shown that optimizing the cogenerated cycle for maximum electrical power output is key in terms of securing investment sustainability. A general review of the acquired results indicates that anaerobic treatment of animal manure and energy crops to produce biogas fuel can constitute a sustainable investment. This applies especially for cases that substantial volumes of substrates are available to ensure stable powerplant operation.

Author(s):  
Georgios Kontokostas ◽  
Ioannis Goulos ◽  
Anastassios Stamatis

This work presents the development of an integrated approach, targeting the techno-economic assessment of recuperated cogeneration gas turbine cycles, utilizing anaerobic digestion products of animal manure and energy crops for biogas fuel. The overall approach consists of a series of fundamental modeling theories applicable to; anaerobic digestion and biogas fuel yield, thermodynamic analysis of cogeneration gas turbine cycles, exergetic analysis of anaerobic digestion, and economic modeling of implementation and operation. The developed methodology is applied to the techno-economic analysis of a representative anaerobic digestion plant yielding biogas fuel which is supplied to a recuperated cogeneration gas turbine powerplant. The influence of employed thermodynamic cycle parameters along with the incorporated technology level, on the cycle performance parameters and economic sustainability of integrated digestion–cogeneration powerplant designs, is thoroughly investigated. The obtained results suggest that, the dominant thermodynamic cycle variables that affect the electrical performance of integrated digestion-cogeneration systems, are the gas/air temperatures at the combustor outlet and recuperator air side exit, respectively. It is shown that the profitability of the investment is highly depended on the electrical power output and the feed–in tariff for electrical energy. Optimization of the employed co-generation cycle for maximum electrical power output, is shown to be a crucial element in terms of securing investment sustainability. A general review of the results indicates that, anaerobic treatment of animal manure and energy crops may constitute a sustainable investment, primarily for cases that substantial volumes of substrates are available in order to secure biogas yield and stable operation of the AD–gas turbine power plant.


Author(s):  
Y. Yang ◽  
J. Y. Chang ◽  
L. P. Wang

The photon transport and energy conversion of a near-field thermophotovoltaic (TPV) system with a selective emitter composed of alternate tungsten and alumina layers and a photovoltaic cell sandwiched by electrical contacts are theoretically investigated in this paper. Fluctuational electrodynamics along with the dyadic Green’s function for a multilayered structure is applied to calculate the spectral heat flux, and photocurrent generation and electrical power output are solved from the photon-coupled charge transport equations. The tungsten and alumina layer thicknesses are optimized to match the spectral heat flux with the bandgap of TPV cell. The spectral heat flux is much enhanced when plain tungsten emitter is replaced with the multilayer emitter due to the mechanism of surface plasmon polariton coupling in the tungsten thin film. In addition, the invalidity of effective medium theory to predict photon transport in the near field with multilayer emitters is discussed. Effects of a gold back reflector and indium tin oxide front coating with nanometer thickness, which could practically act as the electrodes to collect the photon-generated charges on the TPV cell, are explored. Conversion efficiency of 23.7% and electrical power output of 0.31 MW/m2 are achieved at 100 nm vacuum gap when the emitter and receiver are respectively at temperatures of 2000 K and 300 K.


Materials ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 1895
Author(s):  
Mohammad Uddin ◽  
Shane Alford ◽  
Syed Mahfuzul Aziz

This paper focuses on the energy generating capacity of polyvinylidene difluoride (PVDF) piezoelectric material through a number of prototype sensors with different geometric and loading characteristics. The effect of sensor configuration, surface area, dielectric thickness, aspect ratio, loading frequency and strain on electrical power output was investigated systematically. Results showed that parallel bimorph sensor was found to be the best energy harvester, with measured capacitance being reasonably acceptable. Power output increased with the increase of sensor’s surface area, loading frequency, and mechanical strain, but decreased with the increase of the sensor thickness. For all scenarios, sensors under flicking loading exhibited higher power output than that under bending. A widely used energy harvesting circuit had been utilized successfully to convert the AC signal to DC, but at the sacrifice of some losses in power output. This study provided a useful insight and experimental validation into the optimization process for an energy harvester based on human movement for future development.


Author(s):  
Mohamad Modrek ◽  
Ali Al-Alili

Photovoltaic thermal collectors (PVT) combines technologies of photovoltaic panels and solar thermal collectors into a hybrid system by attaching an absorber to the back surface of a PV panel. PVT collectors have gained a lot of attention recently due to the high energy output per unit area compared to a standalone system of PV panels and solar thermal collectors. In this study, performance of a liquid cooled flat PVT collector under the climatic conditions of Abu Dhabi, United Arab Emirates was experimentally investigated. The electrical performances of the PVT collector was compared to that of a standalone PV panel. Moreover, effect of sand accumulation on performance of PVT collectors was examined. Additionally, effect of mass flow rate on thermal and electrical output of PVT collector was studied. Electrical power output is slightly affected by changes in mass flow rate. However, thermal energy increased by 22% with increasing flow rate. Electrical power output of a PV panel was found to be 38% lower compared to electrical output of PVT collectors. Dust accumulation on PVT surface reduced electrical power output up to 7% compared with a reference PVT collector.


2018 ◽  
Vol 171 ◽  
pp. 02002
Author(s):  
Elie Karam ◽  
Patrick Moukarzel ◽  
Maya Chamoun ◽  
Charbel Habchi ◽  
Charbel Bou-Mosleh

Due to global warming and the high toxic gas emissions of traditional power generation methods, renewable energy has become a very active topic in many applications. This study focuses on one versatile type of solar energy: Hybrid Photovoltaic Thermal System (hybrid PV/T). Hybrid PV/T combines both PV and thermal application and by doing this the efficiency of the system will increase by taking advantage of the temperature loss from PV module. The solar radiation and heat will be harnessed to deliver electricity and hot water simultaneously. In the present study a solar system is designed to recycle the heat and improve the temperature loss from PV module in order to supply both electricity and domestic hot water. The project was tested twice in Zouk Mosbeh - Lebanon; on May 18, 2016, and June 7, 2016. The average electrical efficiency was around 11.5% with an average electrical power output of 174.22 W, while with cooling, the average electrical efficiency reaches 11% with a power output of 200 W. The temperature increases by about 7 degrees Celsius from the inlet. The 1D conduction model is also performed in order to design the hybrid PV/T system.


2021 ◽  
Author(s):  
Atsushi Horikawa ◽  
Kunio Okada ◽  
Masato Yamaguchi ◽  
Shigeki Aoki ◽  
Manfred Wirsum ◽  
...  

Abstract Kawasaki Heavy Industries, LTD. (KHI) has research and development projects for a future hydrogen society. These projects comprise the complete hydrogen cycle, including the production of hydrogen gas, the refinement and liquefaction for transportation and storage, and finally the utilization in a gas turbine for electricity and heat supply. Within the development of the hydrogen gas turbine, the key technology is stable and low NOx hydrogen combustion, namely the Dry Low NOx (DLN) hydrogen combustion. KHI, Aachen University of Applied Science, and B&B-AGEMA have investigated the possibility of low NOx micro-mix hydrogen combustion and its application to an industrial gas turbine combustor. From 2014 to 2018, KHI developed a DLN hydrogen combustor for a 2MW class industrial gas turbine with the micro-mix technology. Thereby, the ignition performance, the flame stability for equivalent rotational speed, and higher load conditions were investigated. NOx emission values were kept about half of the Air Pollution Control Law in Japan: 84ppm (O2-15%). Hereby, the elementary combustor development was completed. From May 2020, KHI started the engine demonstration operation by using an M1A-17 gas turbine with a co-generation system located in the hydrogen-fueled power generation plant in Kobe City, Japan. During the first engine demonstration tests, adjustments of engine starting and load control with fuel staging were investigated. On 21st May, the electrical power output reached 1,635 kW, which corresponds to 100% load (ambient temperature 20 °C), and thereby NOx emissions of 65 ppm (O2-15, 60 RH%) were verified. Here, for the first time, a DLN hydrogen-fueled gas turbine successfully generated power and heat.


Author(s):  
Hannah Seliger-Ost ◽  
Peter Kutne ◽  
Jan Zanger ◽  
Manfred Aigner

Abstract The use of biogas has currently two disadvantages. Firstly, processing biogas to natural gas quality for feeding into the natural gas grid is a rather energy consuming process. Secondly, the conversion into electricity directly in biogas plants produces waste heat, which largely cannot be used. Therefore, a feed-in of the desulfurized and dry biogas to local biogas grids would be preferable. Thus, the biogas could be used directly at the end consumer for heat and power production. As biogas varies in its methane (CH4) and carbon dioxide (CO2) content, respectively, this paper studies the influence of different biogas mixtures compared to natural gas on the combustion in a FLOX®-based six nozzle combustor. The single staged combustor is suitable for the use in a micro gas turbine (MGT) based combined heat and power (CHP) system with an electrical power output of 3 kW. The combustor is studied in an optically accessible atmospheric test rig, as well as integrated into the MGT system. This paper focuses on the influence of the admixture of CO2 to natural gas on the NOX and CO emissions. Furthermore, at atmospheric conditions the shape and location of the heat release zone is investigated using OH* chemiluminescence (OH* CL). The combustor could be stably operated in the MGT within the complete stationary operating range with all fuel mixtures.


Author(s):  
Nathan Tom

This paper begins with a brief review of the time-domain equation of motion for a generic floating body. The equation of motion of the floating body was modified to account for the influence of a power-take-off unit (PTO) to predict the hydrodynamic and electromechanical performance of the coupled system. As the damping coefficient is considered the dominant contribution to the PTO reaction force, the optimum non time-varying damping values were first presented for all frequencies, recovering the well-known impedance-matching principle at the coupled resonance frequency. In an effort to further maximize power absorption in both regular and irregular wave environments, nonlinear model predictive control (NMPC) was applied to the model-scale point absorber developed at UC Berkeley. The proposed NMPC strategy requires a PTO unit that could be turned on and off instantaneously, leading, interestingly to electrical sequences where the generator would be inactive for up to 60% of the wave period. In order to validate the effectiveness of this NMPC strategy, an in-house designed permanent magnet linear generator (PMLG) was chosen as the PTO. The time-varying performance of the PMLG was first characterized by dry-bench tests, using mechanical relays to control the electromagnetic conversion process. Following this, the physical set-up was transferred to the wave tank. The on/off sequencing of the PMLG was tested under regular and irregular wave excitation to validate NMPC simulations using control inputs obtained from running the control algorithm offline. Experimental results indicate that successful implementation was achieved and the absorbed power using NMPC was up to 50% greater than the passive system, which utilized no controller. However, after considering the PMLG mechanical-to-electrical conversion efficiency the useful electrical power output was not consistently maximized. To improve output power, a mathematical relation between the efficiency and damping magnitude of the PMLG was inserted in the system model to maximize the electrical power output through continued use of NMPC. Of significance, results from these latter simulations provided a damping time series that was active over a larger portion of the wave period and required the actuation of the applied electrical load connected to the PMLG, rather than a simple on/off type control.


2019 ◽  
Vol 113 ◽  
pp. 02012
Author(s):  
Martina Hohloch ◽  
Melanie Herbst ◽  
Anna Marcellan ◽  
Timo Lingstädt ◽  
Thomas Krummrein ◽  
...  

A hybrid power plant consisting of a micro gas turbine (MGT) and a solid oxide fuel cell (SOFC) is a promising technology to reach the demands for future power plants. DLR aims to set up a MGT/SOFC hybrid power plant demonstrator based on a 3 kWel MTT EnerTwin micro gas turbine and an SOFC module with an electrical power output of 30 kWel from Sunfire. For the detailed investigation of the subsystems under hybrid conditions two separate test rigs are set up, one in which the MGT is connected to an emulator of the SOFC and vice versa. The paper introduces the set-up and the functionalities of the MGT based test rig. The special features are highlighted and the possibilities of the cyber physical system for emulation of a hybrid system are explained.


Sign in / Sign up

Export Citation Format

Share Document