Effects of Turbocharger Rotation Inertia on Instantaneous Turbine Efficiency in a Turbocharged-Gasoline Direct Injection (T-GDI) Engine

2020 ◽  
Vol 143 (1) ◽  
Author(s):  
Chansoo Park ◽  
Motoki Ebisu ◽  
Choongsik Bae

Abstract The effects of turbocharger rotation inertia on instantaneous turbine efficiency were analyzed in a 2.0 L four-cylinder twin-scroll turbocharged gasoline direct injection (T-GDI) engine. Two turbochargers of different weights were prepared for comparison purposes: base T/C and light T/C. In order to evaluate the instantaneous efficiency of each turbocharger, a combination of engine tests and a 1D simulation was conducted. In the experiments, the instantaneous exhaust gas pressures, upstream and downstream of the turbine, were measured. The instantaneous turbocharger rotation speed was also measured. The instantaneous temperature and mass flow rate of the exhaust gas were taken from the 1D simulation results. Through a combination of measuring and simulating exhaust gas states for the turbines, the instantaneous turbine blade speed ratio (BSR), total-to-static turbine efficiency (ηts), reduced mass flow rate (φ), and reduced turbine speed (Nred) were calculated. The light T/C showed higher fluctuations in the instantaneous turbine rotation speed compared to the base T/C. This greater response from the light T/C is due to experiencing less inertia loss, this leads to higher fluctuations in the instantaneous Nred, BSR, ηts, and φ. As a result, the light T/C shows higher turbine efficiency at certain points after the start of the exhaust gas pulse cycle. This is because the greater response of the light T/C lead the operating conditions of the turbine to more efficient regions in the turbine map.

Author(s):  
Mirko Baratta ◽  
Andrea E. Catania ◽  
Nicola Rapetto ◽  
Alois Fuerhapter ◽  
Matthias Gerlich ◽  
...  

In the last few years, a significant research effort has been made for developing and enhancing Direct Injection (DI) for compressed natural gas (CNG) engines. Several research projects have been promoted by the European Community (EC) in this field with the objective of finding new solutions for the automotive market and also of encouraging a fruitful knowledge exchange among car manufacturers, suppliers and technical universities. This paper concerns part of the research activity that has been carried out by the Politecnico di Torino, AVL List GmbH and Siemens AG within the EC VII Framework Program (FP) InGAS Collaborative Project (CP), aimed at optimizing the control phase of a new injector for CNG direct injection, paying specific attention to its behavior at small injected-fuel amounts, i.e., small energizing times. The CNG injector which was developed within the research project proved to be suitable to be used in a DI SI engine, featuring a pent-roof combustion chamber head and a bowl in piston, with reference to both homogeneous and stratified charge formation. Fuel flow measurements made by AVL on the four-cylinder engine revealed a good linearity between injection duration and fuel mass-flow rate for injection durations above a reference value. In order to improve the injector characterization at short injection durations, an experimental and numerical activity was designed. More specifically, a multidimensional CFD model of the actual injector geometry was built by Politecnico di Torino, and purposely-designed simulation cases were carried out, in which the needle-lift time-history was defined on the basis of experimental measurements made by Siemens. The numerical model was validated on the basis of experimental data concerning the total injected-fuel amount under different conditions. Then, the model was applied in order to evaluate the dynamic flow characteristic by taking also the inner geometry of the injector valve group into account, so as to establish a correlation to the needle lift measurements done by Siemens for injector characterization. In the paper this dynamic behavior of the injector is analyzed, under actual operating conditions, and its impact on the nozzle injection capability is discussed. The simulation results did not show significant oscillations of the stagnation pressure upstream of the nozzle throat section, and thus the resultant mass-flow rate profile is almost proportional to the needle-lift one. As a consequence, in order to characterize the injector flow behavior in the nonlinear region (short injection duration), the measurement of needle lift is sufficient.


2021 ◽  
pp. 146808742098460
Author(s):  
Chansoo Park ◽  
Motoki Ebisu ◽  
Choongsik Bae

The effects of turbocharger (T/C) rotational inertia on engine and turbine performance under transient and steady engine conditions were analyzed in a 2.0 L 4-cylinder turbocharged-gasoline direct injection (T-GDI) engine. The test T/Cs consisted of heavy and light compressor wheels (C/W) and turbine wheels (T/W). The study was conducted in two research stages. First, transient engine load tests were conducted to evaluate the effect of T/C rotational inertia on transient response of the T/C, combustion performance, and fuel consumption. Seconds, steady engine load tests were conducted to find out if a light inertia T/C can run at higher efficiency under the same exhaust pulsating flow conditions within one engine cycle. In order to evaluate the engine on-board turbine instantaneous performances in the units of crank angle degree (CAD), T/C rotation speed and pressure data were measured in the experiment. The instantaneous exhaust gas mass flow rate and the temperature of upstream and downstream of the turbine were extracted by 1-D simulation. Turbine efficiency and mass flow rate parameters were calculated by combining these data. In the results, there existed positive effects of light inertia T/C on response and specific fuel consumption under transient conditions. It was also found that the light inertia T/C could show higher T/C speed fluctuation under the same exhaust pulsating flow conditions. Consequently, blade speed ratio (BSR) and turbine efficiency of light inertia T/C were partially higher than that of conventional one. However, it was not led to higher engine efficiency.


2005 ◽  
Vol 127 (5) ◽  
pp. 1029-1037 ◽  
Author(s):  
L. O. Schunk ◽  
G. F. Nellis ◽  
J. M. Pfotenhauer

Growing interest in larger scale pulse tubes has focused attention on optimizing their thermodynamic efficiency. For Stirling-type pulse tubes, the performance is governed by the phase difference between the pressure and mass flow, a characteristic that can be conveniently adjusted through the use of inertance tubes. In this paper we present a model in which the inertance tube is divided into a large number of increments; each increment is represented by a resistance, compliance, and inertance. This model can include local variations along the inertance tube and is capable of predicting pressure, mass flow rate, and the phase between these quantities at any location in the inertance tube as well as in the attached reservoir. The model is verified through careful comparison with those quantities that can be easily and reliably measured; these include the pressure variations along the length of the inertance tube and the mass flow rate into the reservoir. These experimental quantities are shown to be in good agreement with the model’s predictions over a wide range of operating conditions. Design charts are subsequently generated using the model and are presented for various operating conditions in order to facilitate the design of inertance tubes for pulse tube refrigerators. These design charts enable the pulse tube designer to select an inertance tube geometry that achieves a desired phase shift for a given level of acoustic power.


Author(s):  
Brian M. T. Tang ◽  
Marko Bacic ◽  
Peter T. Ireland

This paper presents a computational investigation into the impact of cooling air injected through the stationary over-tip turbine casing on overall turbine efficiency. The high work axial flow turbine is representative of the high pressure turbine of a civil aviation turbofan engine. The effect of active modulation of the cooling air is assessed, as well as that of the injection locations. The influence of the through-casing coolant injection on the turbine blade over-tip leakage flow and the associated secondary flow features are examined. Transient (unsteady) sliding mesh simulations of a one turbine stage rotor-stator domain are performed using periodic boundary conditions. Cooling air configurations with a constant total pressure air supply, constant mass flow rate and actively controlled total pressure supply are assessed for a single geometric arrangement of cooling holes. The effects of both the mass flow rate of cooling air and the location of its injection relative to the turbine rotor blade are examined. The results show that all of the assessed cooling configurations provided a benefit to turbine row efficiency of between 0.2 and 0.4 percentage points. The passive and constant mass flow rate configurations reduced the over-tip leakage flow, but did so in an inefficient manner, with decreasing efficiency observed with increasing injection mass flow rate beyond 0.6% of the mainstream flow, despite the over-tip leakage mass flow rate continuing to reduce. By contrast, the active total pressure controlled injection provided a more efficient manner of controlling this leakage flow, as it permitted a redistribution of cooling air, allowing it to be applied in the regions close to the suction side of the blade tip which more directly reduced over-tip leakage flow rates and hence improved efficiency. Cooling air injected close to the pressure side of the rotor blade was less effective at controlling the leakage flow, and was associated with increased aerodynamic loss in the passage vortex.


2018 ◽  
Vol 8 (9) ◽  
pp. 1413 ◽  
Author(s):  
Dan Yao ◽  
Kwongi Lee ◽  
Minho Ha ◽  
Cheolung Cheong ◽  
Inhiug Lee

A new pump, called the hybrid airlift-jet pump, is developed by reinforcing the advantages and minimizing the demerits of airlift and jet pumps. First, a basic design of the hybrid airlift-jet pump is schematically presented. Subsequently, its performance characteristics are numerically investigated by varying the operating conditions of the airlift and jet parts in the hybrid pump. The compressible unsteady Reynolds-averaged Navier-Stokes equations, combined with the homogeneous mixture model for multiphase flow, are used as the governing equations for the two-phase flow in the hybrid pump. The pressure-based methods combined with the Pressure-Implicit with Splitting of Operators (PISO) algorithm are used as the computational fluid dynamics techniques. The validity of the present numerical methods is confirmed by comparing the predicted mass flow rate with the measured ones. In total, 18 simulation cases that are designed to represent the various operating conditions of the hybrid pump are investigated: eight of these cases belong to the operating conditions of only the jet part with different air and water inlet boundary conditions, and the remaining ten cases belong to the operating conditions of both the airlift and jet parts with different air and water inlet boundary conditions. The mass flow rate and the efficiency are compared for each case. For further investigation into the detailed flow characteristics, the pressure and velocity distributions of the mixture in a primary pipe are compared. Furthermore, a periodic fluctuation of the water flow in the mass flow rate is found and analyzed. Our results show that the performance of the jet or airlift pump can be enhanced by combining the operating principles of two pumps into the hybrid airlift-jet pump, newly proposed in the present study.


2021 ◽  
Vol 39 (4) ◽  
pp. 1225-1235
Author(s):  
Ajay K. Gupta ◽  
Manoj Kumar ◽  
Ranjit K. Sahoo ◽  
Sunil K. Sarangi

Plate-fin heat exchangers provide a broad range of applications in many cryogenic industries for liquefaction and separation of gasses because of their excellent technical advantages such as high effectiveness, compact size, etc. Correlations are available for the design of a plate-fin heat exchanger, but experimental investigations are few at cryogenic temperature. In the present study, a cryogenic heat exchanger test setup has been designed and fabricated to investigate the performance of plate-fin heat exchanger at cryogenic temperature. Major parameters (Colburn factor, Friction factor, etc.) that affect the performance of plate-fin heat exchangers are provided concisely. The effect of mass flow rate and inlet temperature on the effectiveness and pressure drop of the heat exchanger are investigated. It is observed that with an increase in mass flow rate effectiveness and pressure drop increases. The present setup emphasis the systematic procedure to perform the experiment based on cryogenic operating conditions and represent its uncertainties level.


Author(s):  
Dominik Schlüter ◽  
Robert P. Grewe ◽  
Fabian Wartzek ◽  
Alexander Liefke ◽  
Jan Werner ◽  
...  

Abstract Rotating stall is a non-axisymmetric disturbance in axial compressors arising at operating conditions beyond the stability limit of a stage. Although well-known, its driving mechanisms determining the number of stall cells and their rotational speed are still marginally understood. Numerical studies applying full-wheel 3D unsteady RANS calculations require weeks per operating point. This paper quantifies the capability of a more feasible quasi-2D approach to reproduce 3D rotating stall and related sensitivities. The first part of the paper deals with the validation of a numerical baseline the simplified model is compared to in detail. Therefore, 3D computations of a state-of-the-art transonic compressor are conducted. At steady conditions the single-passage RANS CFD matches the experimental results within an error of 1% in total pressure ratio and mass flow rate. At stalled conditions, the full-wheel URANS computation shows the same spiketype disturbance as the experiment. However, the CFD underpredicts the stalling point by approximately 7% in mass flow rate. In deep stall, the computational model correctly forecasts a single-cell rotating stall. The stall cell differs by approximately 21% in rotational speed and 18% in circumferential size from the experimental findings. As the 3D model reflects the compressor behaviour sufficiently accurate, it is considered valid for physical investigations. In the second part of the paper, the validated baseline is reduced in radial direction to a quasi-2D domain only resembling the compressor tip area. Four model variations regarding span-wise location and extent are numerically investigated. As the most promising model matches the 3D flow conditions in the rotor tip region, it correctly yields a single-cell rotating stall. The cell differs by only 7% in circumferential size from the 3D results. Due to the impeded radial migration in the quasi-2D slice, however, the cell exhibits an increased axial extent. It is assumed, that the axial expansion into the adjacent rows causes the difference in cell speed by approximately 24%. Further validation of the reduced model against experimental findings reveals, that it correctly reflects the sensitivity of circumferential cell size to flow coefficient and individual cell speed to compressor shaft speed. As the approach reduced the wall clock time by 92%, it can be used to increase the physical understanding of rotating stall at much lower costs.


2018 ◽  
Vol 204 ◽  
pp. 06007
Author(s):  
Mohammad Mahardika

Every year, Indonesia's population increase so as energy demand. To fulfill Indonesia's energy needs, the capacity of energy production should be increased. Indonesia government has made a solution by propose 35.000 MW program to increase energy production and electrification ratio in Indonesia. An insulated area where electricity did not reach, has many problem to get electricity such as limited infrastructure, low fuel energy content, and expensive turbine. To solve these problem, multi-vane expander (MVE) can be used to extract the low energy and is cheap. MVE have many advantages such as cheap, easy to manufacture, able to operate with 2 phase, and able to low speed operation. But, the disadvantage of this type of expander is leakage. In this paper, experimental and CFD analysis of MVE are conducted. The experiment generated power of 25.7 watt with isentropic and volumetric efficiency of 11.6% and 11.7% by using operating condition of 1.5 bar, 115.6 °C, 626 rpm, and mass flow rate of 80 kg/h. The CFD model of the expander is created with the same dimension and operating conditions as experimental. The result for isentropic efficiency is inversely proportional with mass flow rate and for volumetric efficiency, power, and expander rotation are directly proportional with mass flow rate.


Author(s):  
Saad A. Ahmed

Centrifugal compressors or blowers are widely used in many industrial applications. However, the operation of such systems is limited at low-mass flow rates by self-excited flow instabilities which could result in rotating stall or surge of the compressor. These instabilities will limit the flow range in which the compressor or the blower can operate, and will also lower their performance and efficiency. Experimental techniques were used to investigate a model of radial vaneless diffuser at stall and stall-free operating conditions. The speed of the impeller was kept constant, while the mass flow rate was reduced gradually to study the steady and unsteady operating conditions of the compressor. Additional experiments were made to investigate the effects of reducing the exit flow area on the inception of stall. The results indicate that the instability in the diffuser was successfully delayed to a lower flow coefficient when throttle rings were attached to either one or both of the diffuser walls (i.e., to reduce the diffuser exit flow area). The results also showed that an increase of the blockage ratio improves the stability of the system (i.e., the critical mass flow rate could be reduced to 50% of its value without blockage). The results indicate that the throttle rings could be an effective method to control stall in radial diffusers.


2019 ◽  
Vol 16 (3) ◽  
pp. 368-376
Author(s):  
Dipak Sudam Patil ◽  
Rachayya R. Arakerimath ◽  
Pramod V. Walke

Purpose This paper aims to present an experimental investigation and optimization of a low-temperature thermoelectric module to examine the influence of the main operating conditions. Design/methodology/approach In this work, a comparison was made by varying the various operating parameters such as heat source temperature, the flow rate of the cold fluid and the external load resistance. A Taguchi method was applied to optimize the parameters of the system. Three factors, including the external load resistance, mass flow rate of water (at the heat sink side) and heater temperature (at the heat source side) along with different levels were taken into account. Analysis of variance was used to determine the significance and percentage contribution of each parameter. Findings The experimental results show that the maximum power output 8.22W and the maximum conversion efficiency 1.11 per cent were obtained at the heater temperature of 240°C, the cold fluid mass flow rate of 0.017 kg/s, module temperature difference of 45°C and the load resistance of 5 O. It was observed that the optimum parameter levels for maximum power output determined as 5 O external load resistance, 0.17 kg/s mass flow rate of water and 240°C heater temperature (A1B3C3). It reflects that these parameters influence on the optimum conditions. The heater temperature is the most significant parameter on the power output of the thermoelectric module. Originality/value It is clear from the confirmation test that experimental values and the predicted values are in good agreement.


Sign in / Sign up

Export Citation Format

Share Document