Advanced Power Generation: The Potential of Indirectly-Fired Combined Cycles

Author(s):  
Julianne M. Klara ◽  
Michael S. Izsak ◽  
Michael R. Wherley

The next generation of coal-fueled power plants must be efficient, clean, and cost-effective. The U.S. Department of Energy (DOE) sponsors a program to develop an advanced, coal-based power system called HIPPS, or High Performance Power System, to meet these requirements. In the HIPPS cycle, air from a gas turbine compressor is indirectly heated in a coal-fueled furnace and then further heated directly with natural gas to power a gas turbine. Indirect heating of the gas turbine working fluid avoids the problems associated with expansion of a corrosive, coal-derived gas through a turbine. Steam is also generated to power a bottoming Rankine cycle. This paper presents an analysis of the performance of HIPPS that is achievable using current technology and projects the level of performance as technology advances. The HIPPS cycle using current technology produces electricity from coal at a thermal efficiency that is more than 40 percent higher than that of today’s average coal-based power plants. The effect of advanced gas turbines, a novel gas turbine cycle, high performance steam cycles, and advanced coal-fueled furnace materials/designs is estimated with the use of computer-based engineering tools. Promising system configurations for future generations of HIPPS are identified with cycle efficiencies as high as 49.3 percent on a higher heating value basis.

1979 ◽  
Author(s):  
H. C. Daudet ◽  
C. A. Kinney

This paper presents a discussion of the significant results of a study program conducted for the Department of Energy to evaluate the potential for closed cycle gas turbines and the associated combustion heater systems for use in coal fired public utility power plants. Two specific problem areas were addressed: (a) the identification and analysis of system concepts which offer high overall plant efficiency consistent with low cost of electricity (COE) from coal-pile-to-bus-bar, and (b) the identification and conceptual design of combustor/heat exchanger concepts compatible for use as the cycle gas primary heater for those plant systems. The study guidelines were based directly upon the ground rules established for the ECAS studies to facilitate comparison of study results. Included is a discussion of a unique computer model approach to accomplish the system analysis and parametric studies performed to evaluate entire closed cycle gas turbine utility power plants with and without Rankine bottoming cycles. Both atmospheric fluidized bed and radiant/convective combustor /heat exchanger systems were addressed. Each incorporated metallic or ceramic heat exchanger technology. The work culminated in conceptual designs of complete coal fired, closed cycle gas turbine power plants. Critical component technology assessment and cost and performance estimates for the plants are also discussed.


Author(s):  
F. L. Robson ◽  
D. J. Seery

The Department of Energy’s Federal Energy Technology Center (FETC) is sponsoring the Combustion 2000 Program aimed at introducing clean and more efficient advanced technology coal-based power systems in the early 21st century. As part of this program, the United Technologies Research Center has assembled a seven member team to identify and develop the technology for a High Performance Power Systems (HIPPS) that will provide in the near term, 47% efficiency (HHV), and meet emission goals only one-tenth of current New Source Performance Standards for coal-fired power plants. In addition, the team is identifying advanced technologies that could result in HIPPS with efficiencies approaching 55% (HHV). The HIPPS is a combined cycle that uses a coal-fired High Temperature Advanced Furnace (HITAF) to preheat compressor discharge air in both convective and radiant heaters. The heated air is then sent to the gas turbine where additional fuel, either natural gas or distillate, is burned to raise the temperature to the levels of modern gas turbines. Steam is raised in the HITAF and in a Heat Recovery Steam Generator for the steam bottoming cycle. With state-of-the-art frame type gas turbines, the efficiency goal of 47% is met in a system with more than two-thirds of the heat input furnished by coal. By using advanced aeroderivative engine technology, HIPPS in combined-cycle and Humid Air Turbine (HAT) cycle configurations could result in efficiencies of over 50% and could approach 55%. The following paper contains descriptions of the HIPPS concept including the HITAF and heat exchangers, and of the various gas turbine configurations. Projections of HIPPS performance, emissions including significant reduction in greenhouse gases are given. Application of HIPPS to repowering is discussed.


Author(s):  
Sandro Barros Ferreira ◽  
Pericles Pilidis

The use of biomass as gas turbine combined cycle fuels is broadly seen as one of the alternatives to diminish greenhouse gas emissions, mainly CO2, due to the efficiency delivered by such systems and the renewable characteristic of biomass itself. Integrated gasification cycles, BIGGT, are the current technology available; however the gasification system severely penalizes the power plant in terms of efficiency and demands modifications in the engine to accommodate the large fuel mass flow. This gives an opportunity to improvements in the current technologies and implementation of new ones. This paper intends to analyze new alternatives to the use of solid fuels in gas turbines, from the economical point of view, through the use of external combustion, EFGT, discussing its advantages and limitations over the current technology. The results show that both EFGT and BIGGT technologies are economically competitive with the current natural gas fired gas turbines. However, BIGGT power plants are still in pilot scale and the EFGT plants need further technological development. Thermodynamically speaking, the inherently recuperative characteristic of the EFGT gas turbine engine makes it well suited to the biomass market. The thermal efficiency of this cycle is higher than the BIGGT system. Furthermore, its fuel flexibility and negligible pre-treatmet is another advantage that makes it an interesting option for the Brazilian market.


Author(s):  
Igor Pioro ◽  
Mohammed Mahdi ◽  
Roman Popov

SuperCritical Fluids (SCFs) have unique thermophyscial properties and heat-transfer characteristics, which make them very attractive for use in power industry. In this chapter, specifics of thermophysical properties and heat transfer of SCFs such as water, carbon dioxide and helium are considered and discussed. Also, particularities of heat transfer at SuperCritical Pressures (SCPs) are presented, and the most accurate heat-transfer correlations are listed. SuperCritical Water (SCW) is widely used as the working fluid in the SCP Rankine “steam”-turbine cycle in fossil-fuel thermal power plants. This increase in thermal efficiency is possible by application of high-temperature reactors and power cycles. Currently, six concepts of Generation-IV reactors are being developed, with coolant outlet temperatures of 500°C~1000°C. SCFs will be used as coolants (helium in GFRs and VHTRs; and SCW in SCWRs) and/or working fluids in power cycles (helium; mixture of nitrogen (80%) and helium [20%]; nitrogen, and carbon dioxide in Brayton gas-turbine cycles; and SCW “steam” in Rankine cycle).


Author(s):  
V.D. Molyakov ◽  
B.A. Kunikeev ◽  
N.I. Troitskiy

Closed-cycle gas turbine units can be used as power plants for advanced nuclear power stations, spacecraft, ground, surface and underwater vehicles. The purpose and power capacity of closed gas turbine units (CGTU) determine their specific design schemes, taking into account efficient operation of the units both in the nominal (design) mode and in partial power modes. Control methods of both closed and open gas turbine units depend on the scheme and design of the installation but the former differ from the latter mainly in their ability to change gas pressure at the entrance to the low-pressure compressor. This pressure can be changed by controlling the mass circulating in the CGTU circuit, adding or releasing part of the working fluid from the closed system as well as by internal bypassing of the working fluid. At a constant circulating mass in the single-shaft CGTU, the temperature of the gas before the turbines and the shaft speed can be adjusted depending on the type of load. The rotational speed of the turbine shaft, blocked with the compressor, can be adjusted in specific ways, such as changing the cross sections of the flow of the impellers. At a constant mass of the working fluid, the pressure at the entrance to the low-pressure compressor varies depending on the control program. The efficiency of the CGTU in partial power modes depends on the installation scheme, control method and program. The most economical control method is changing the pressure in the circuit. Extraction of the working fluid into special receivers while maintaining the same temperature in all sections of the unit leads to a proportional decrease in the density of the working fluid in all sections and the preservation of gas-dynamic similarity in the nodes (compressors, turbines and pipelines). Specific heat flux rates, and therefore, temperatures change slightly in heat exchangers. As the density decreases, heat fluxes change, as the heat transfer coefficient decreases more slowly than the density of the working fluid. With a decrease in power, this leads to a slight increase in the degree of regeneration and cooling in the heat exchangers. The underestimation of these phenomena in the calculations can be compensated by the underestimation of the growth of losses in partial power modes.


Author(s):  
Gunnar Lagerstro¨m ◽  
Max Xie

Rekuperator Svenska AB owned by VOLVO Technology Transfer Corporation and Avesta Polarit, has successfully developed a completely laser welded recuperator for micro-gas turbine applications. Tests have shown that the thermal performance is very competitive. The recuperator was installed in a 100 kW(e) micro-gas turbine power plant for combined electricity and heat generation by a customer. The recuperator is a primary surface counter flow heat exchanger with cross corrugated duct configuration. The primary heat transfer surface plate patterns are stamped and a pair of the plates are laser welded to form an air cell. The air cells are then stacked and laser welded together to form the recuperator core which is tied between two end beams. Manifolds for air inlet and outlet as well as piping system are welded to the core. Through varying the number of air cells the recuperator core can easily be adapted for micro-gas turbine applications with different output rates of electrical power. The key manufacturing technologies are stamping of the air cell plates and laser welding of the air cells. These processes can be fully automated for mass production at low costs.


2015 ◽  
Vol 137 (12) ◽  
pp. 54-55
Author(s):  
Lee S. Langston

This article explains how combined cycle gas turbine (CCGT) power plants can help in reducing greenhouse gas from the atmosphere. In the last 25 years, the development and deployment of CCGT power plants represent a technology breakthrough in efficient energy conversion, and in the reduction of greenhouse gas production. Existing gas turbine CCGT technology can provide a reliable, on-demand electrical power at a reasonable cost along with a minimum of greenhouse gas production. Natural gas, composed mostly of methane, is a hydrocarbon fuel used by CCGT power plants. Methane has the highest heating value per unit mass of any of the hydrocarbon fuels. It is the most environmentally benign of fuels, with impurities such as sulfur removed before it enters the pipeline. If a significant portion of coal-fired Rankine cycle plants are replaced by the latest natural gas-fired CCGT power plants, anthropogenic carbon dioxide released into the earth’s atmosphere would be greatly reduced.


2014 ◽  
Vol 136 (07) ◽  
pp. 38-43
Author(s):  
Lee S. Langston

This article focuses on the use of gas turbines for electrical power, mechanical drive, and marine applications. Marine gas turbines are used to generate electrical power for propulsion and shipboard use. Combined-cycle electric power plants, made possible by the gas turbine, continue to grow in size and unmatched thermal efficiency. These plants combine the use of the gas turbine Brayton cycle with that of the steam turbine Rankine cycle. As future combined cycle plants are introduced, we can expect higher efficiencies to be reached. Since almost all recent and new U.S. electrical power plants are powered by natural gas-burning, high-efficiency gas turbines, one has solid evidence of their contribution to the greenhouse gas reduction. If coal-fired thermal power plants, with a fuel-to-electricity efficiency of around 33%, are swapped out for combined-cycle power plants with efficiencies on the order of 60%, it will lead to a 70% reduction in carbon emissions per unit of electricity produced.


Author(s):  
Leonid Moroz ◽  
Petr Pagur ◽  
Oleksii Rudenko ◽  
Maksym Burlaka ◽  
Clement Joly

Bottoming cycles are drawing a real interest in a world where resources are becoming scarcer and the environmental footprint of power plants is becoming more controlled. Reduction of flue gas temperature, power generation boost without burning more fuel and even production of heat for cogeneration applications are very attractive and it becomes necessary to quantify how much can really be extracted from a simple cycle to be converted to a combined configuration. As supercritical CO2 is becoming an emerging working fluid [2, 3, 5, 7 and 8] due not only to the fact that turbomachines are being designed significantly more compact, but also because of the fluid’s high thermal efficiency in cycles, it raises an increased interest in its various applications. Evaluating the option of combined gas and supercritical CO2 cycles for different gas turbine sizes, gas turbine exhaust gas temperatures and configurations of bottoming cycle type becomes an essential step toward creating guidelines for the question, “how much more can I get with what I have?”. Using conceptual design tools for the cycle system generates fast and reliable results to draw this type of conclusion. This paper presents both the qualitative and quantitative advantages of combined cycles for scalability using machines ranging from small to several hundred MW gas turbines to determine which configurations of S-CO2 bottoming cycles are best for pure electricity production.


2018 ◽  
Vol 140 (03) ◽  
pp. S54-S55
Author(s):  
Uwe Schütz

This article describes features and advantages of new mobile gas turbine with a wide range of applications. The market for mobile gas turbines is continuously growing. Mobile units are also an ideal choice when it comes to making large power capacities available on a short-term basis, for example, for major events, prolonged downtimes at other power stations, or power-intensive applications such as mining or shale gas extraction. If the electricity requirements exceed the level that can normally be demanded of a mobile application, an SGT-A45 installation can be modified to form a combined-cycle power plant to further improve its efficiency. In remote locations, this can be achieved using an Organic Rankine Cycle (ORC), to eliminate the need for water and water treatment systems, and to optimize energy recovery from the SGT-A45 off-gas stream at a relatively low temperature. The use of a direct heat exchanger, in which the ORC working fluid is evaporated by the off-gas stream from the gas turbine, can boost the system’s output capacity by more than 20 percent.


Sign in / Sign up

Export Citation Format

Share Document