Performance of Francis Turbine Operating at Excess Load Condition

Author(s):  
Muhannad Altimemy ◽  
Justin Caspar ◽  
Alparslan Oztekin

Abstract Computational fluid dynamics simulations are conducted to characterize the spatial and temporal characteristics of the flow field inside a Francis turbine operating in the excess load regime. A high-fidelity Large Eddy Simulation (LES) turbulence model is applied to investigate the flow-induced pressure fluctuations in the draft tube of a Francis Turbine. Probes placed alongside the wall and in the center of the draft tube measure the pressure signal in the draft tube, the pressure over the turbine blades, and the power generated to compare against previous studies featuring design point and partial load operating conditions. The excess load is seen during Francis turbines in order to satisfy a spike in the electrical demand. By characterizing the flow field during these conditions, we can find potential problems with running the turbine at excess load and inspire future studies regarding mitigation methods. Our studies found a robust low-pressure region on the edges of turbine blades, which could cause cavitation in the runner region, which would extend through the draft tube, and high magnitude of pressure fluctuations were observed in the center of the draft tube.

Author(s):  
Muhannad Altimemy ◽  
Bashar Attiya ◽  
Cosan Daskiran ◽  
I-Han Liu ◽  
Alparslan Oztekin

Abstract Computational fluid dynamics simulations are conducted to characterize the spatial and temporal characteristics of the turbulent flow fields inside Francis turbine operating at the design and partial load regimes. High-fidelity large eddy simulations turbulence model is applied to investigate the flow-induced vibrations in the draft tube of the unit. The water injection at 4% rate from the runner cone is implemented to control the flow-induced pressure fluctuations. The simulations are conducted at the turbine design point and two partial load operations with and without water injection. It has been demonstrated that the water injection has a profound influence in the turbulent flow structure and the pressure field inside the draft tube at the partial load operating conditions. To evaluate the effectiveness of the water injection techniques in mitigating flow-induced fluctuations, the probes at various locations along the wall of the draft tube are used to monitor the pressure signals. It appears to be a reduction in the level of pressure fluctuations by the water injection at both partial load operating regimes. However, we could not draw a firm conclusion about the level of mitigation of flow-induced vibrations. Simulations should be carried out for much longer flow time. Water injection hardly influenced the unit power generation. Hence water injection can be employed effectively without a major liability on the power generation.


2019 ◽  
Vol 11 (1) ◽  
pp. 168781401882446 ◽  
Author(s):  
Xing Zhou ◽  
He-gao Wu ◽  
Chang-zheng Shi

An improved method for preventing vortex rope formation and alleviating the associated pressure fluctuations in turbine draft tubes is investigated using baffles in the draft tube to hinder the swirling flow emerging from a Francis turbine runner. A strong swirl produces flow instabilities and pressure fluctuations. Partial load operating conditions at the rated water head and three flow rates are taken into consideration. It is demonstrated using a computational fluid dynamics simulation that this method effectively eliminates the vortex rope, particularly when using four baffles. The amplitude of the pressure pulsation in the draft tube modified with four baffles was 0.42 times that in a traditional draft tube. The baffles were found to reduce the tangential velocity of the flow in the draft tube and consequently hinder the development of the fierce swirling flow. This type of decrease is more significant compared to the gradual decay due to viscous effects of the solid wall in a traditional draft tube. The conclusion was verified by the results of experiments conducted using a novel device. The measured increase in turbine efficiency exceeded 3% at the evaluated partial loading point, indicating improved economic performance of the turbine.


Energies ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1734
Author(s):  
Xing Zhou ◽  
Changzheng Shi ◽  
Kazuyoshi Miyagawa ◽  
Hegao Wu ◽  
Jinhong Yu ◽  
...  

Under the circumstances of rapid expansion of diverse forms of volatile and intermittent renewable energy sources, hydropower stations have become increasingly indispensable for improving the quality of energy conversion processes. As a consequence, Francis turbines, one of the most popular options, need to operate under off-design conditions, particularly for partial load operation. In this paper, a prototype Francis turbine was used to investigate the pressure fluctuations and hydraulic axial thrust pulsation under four partial load conditions. The analyses of pressure fluctuations in the vaneless space, runner, and draft tube are discussed in detail. The observed precession frequency of the vortex rope is 0.24 times that of the runner rotational frequency, which is able to travel upstream (from the draft tube to the vaneless space). Frequencies of both 24.0 and 15.0 times that of the runner rotational frequency are detected in the recording points of the runner surface, while the main dominant frequency recorded in the vaneless zone is 15.0 times that of the runner rotational frequency. Apart from unsteady pressure fluctuations, the pulsating property of hydraulic axial thrust is discussed in depth. In conclusion, the pulsation of hydraulic axial thrust is derived from the pressure fluctuations of the runner surface and is more complicated than the pressure fluctuations.


2014 ◽  
Vol 81 (6) ◽  
Author(s):  
Hosein Foroutan ◽  
Savas Yavuzkurt

Numerical simulations and analysis of the vortex rope formation in a simplified draft tube of a model Francis turbine are carried out in this paper, which is the first part of a two-paper series. The emphasis of this part is on the simulation and investigation of flow using different turbulence closure models. Two part-load operating conditions with same head and different flow rates (91% and 70% of the best efficiency point (BEP) flow rate) are considered. Steady and unsteady simulations are carried out for axisymmetric and three-dimensional grid in a simplified axisymmetric geometry, and results are compared with experimental data. It is seen that steady simulations with Reynolds-averaged Navier–Stokes (RANS) models cannot resolve the vortex rope and give identical symmetric results for both the axisymmetric and three-dimensional flow geometries. These RANS simulations underpredict the axial velocity (by at least 14%) and turbulent kinetic energy (by at least 40%) near the center of the draft tube, even quite close to the design condition. Moving farther from the design point, models fail in predicting the correct levels of the axial velocity in the draft tube. Unsteady simulations are performed using unsteady RANS (URANS) and detached eddy simulation (DES) turbulence closure approaches. URANS models cannot capture the self-induced unsteadiness of the vortex rope and give steady solutions while DES model gives sufficient unsteady results. Using the proper unsteady model, i.e., DES, the overall shape of the vortex rope is correctly predicted and the calculated vortex rope frequency differs only 6% from experimental data. It is confirmed that the vortex rope is formed due to the roll-up of the shear layer at the interface between the low-velocity inner region created by the wake of the crown cone and highly swirling outer flow.


2014 ◽  
Vol 81 (6) ◽  
Author(s):  
Hosein Foroutan ◽  
Savas Yavuzkurt

Numerical simulations and investigation of a method for controlling the vortex rope formation in draft tubes are carried out in this paper, which is the second part of a two-paper series. As shown in the companion paper, formation of the vortex rope is associated with a large stagnant region at the center of the draft tube. Therefore, it is concluded that a successful control technique should focus on the elimination of this region. In practice, this can be performed by axially injecting a small fraction (a few percent of the total flow rate) of water into the draft tube. Water jet is supplied from the high-pressure flow upstream of the turbine spiral case by a bypass line; thus, no extra pump is needed in this method. It is shown that this method is very effective in elimination of the stagnant region in a simplified draft tube operating at two part-load conditions, i.e., at 91% and 70% of the best efficiency point (BEP) flow rate. This results in improvement of the draft tube performance and reduction of hydraulic losses. The loss coefficient is reduced by as much as 50% for the case with 91% of BEP flow rate and 14% for the case with 70% of BEP flow rate. Unsteady, three-dimensional simulations show that the jet increases the axial momentum of flow at the center of the draft tube and decreases the wake of the crown cone and thereby decreases the shear at the interface of the stagnant region and high velocity outer flow, which ultimately results in elimination of the vortex rope. Furthermore, reduction (by about 1/3 in the case with 70% of BEP flow rate) of strong pressure fluctuations leads to reliable operation of the turbine.


2015 ◽  
Vol 32 (6) ◽  
pp. 1549-1566 ◽  
Author(s):  
Lei Tan ◽  
Baoshan Zhu ◽  
Yuchuan Wang ◽  
Shuliang CAO ◽  
Shaobo Gui

Purpose – The purpose of this paper is to elucidate the detailed flow field and cavitation effect in the centrifugal pump volute at partial load condition. Design/methodology/approach – Unsteady flows in a centrifugal pump volute at non-cavitation and cavitation conditions are investigated by using a computation fluid dynamics framework combining the re-normalization group k-e turbulence model and the mass transport cavitation model. Findings – The flow field in pump volute is very complicated at part load condition with large pressure gradient and intensive vortex movement. Under cavitation conditions, the dominant frequency for most of the monitoring points in volute transit from the blade passing frequency to a lower frequency. Generally, the maximum amplitudes of pressure fluctuations in volute at serious cavitation condition is twice than that at non-cavitation condition because of the violent disturbances caused by cavitation shedding and explosion. Originality/value – The detailed flow field and cavitation effect in the centrifugal pump volute at partial load condition are revealed and analysed.


2009 ◽  
Vol 131 (8) ◽  
Author(s):  
Jorge Arpe ◽  
Christophe Nicolet ◽  
François Avellan

The complex three-dimensional unsteady flow developing in the draft tube of a Francis turbine is responsible for pressure fluctuations, which could prevent the whole hydropower plant from operating safely. Indeed, the Francis draft tube is subjected to inlet swirling flow, divergent cross section, and the change of flow direction. As a result, in low discharge off-design operating conditions, a cavitation helical vortex, so-called the vortex rope develops in the draft tube and induces pressure fluctuations in the range of 0.2–0.4 times the runner frequency. This paper presents the extensive unsteady wall pressure measurements performed in the elbow draft tube of a high specific speed Francis turbine scale model at low discharge and at usual plant value of the Thoma cavitation number. The investigation is undertaken for operating conditions corresponding to low discharge, i.e., 0.65–0.85 times the design discharge, which exhibits pressure fluctuations at surprisingly high frequency value, between 2 and 4 times the runner rotation frequency. The pressure fluctuation measurements performed with 104 pressure transducers distributed on the draft tube wall, make apparent in the whole draft tube a fundamental frequency value at 2.5 times the runner frequency. Moreover, the modulations between this frequency with the vortex rope precession frequency are pointed out. The phase shift analysis performed for 2.5 times the runner frequency enables the identification of a pressure wave propagation phenomenon and indicates the location of the corresponding pressure fluctuation excitation source in the elbow; hydroacoustic waves propagate from this source both upstream and downstream the draft tube.


Author(s):  
Muhannad Altimemy ◽  
Justin Caspar ◽  
Saif Watheq ◽  
Alparslan Oztekin

Abstract High-fidelity large eddy simulations (LES) were conducted to characterize the spatial and temporal structure of turbulent flows in an industrial-sized Francis turbine. The unit operated at 50% and 40% of the best efficiency design flowrate. Contours of vorticity, velocity, pressure, and iso-surfaces of Q-Criterion were presented to characterize the effects on the draft tube. Probes placed alongside the draft tube measure the pressure signal to investigate the flow-induced pressure fluctuations inside the turbine unit. The maximum intensity of pressure fluctuations at 50% partial load was 22.66% of the turbine head, while the strength of the pressure fluctuations was 26.36% at 40% partial load. A large number of unorganized smaller vortices observed in the draft tube contribute to the creation of pressure fluctuations. Two pressure modes can be easily recognized (1) high frequency with low amplitude pressure fluctuations and (2) low frequency with high amplitude fluctuations. These pressure fluctuations could be harmful to the structural integrity of the unit and also have undesirable influences on the operational stability of the hydro-turbines.


Processes ◽  
2021 ◽  
Vol 9 (7) ◽  
pp. 1182
Author(s):  
Seung-Jun Kim ◽  
Yong Cho ◽  
Jin-Hyuk Kim

Under low flow-rate conditions, a Francis turbine exhibits precession of a vortex rope with pressure fluctuations in the draft tube. These undesirable flow phenomena can lead to deterioration of the turbine performance as manifested by torque and power output fluctuations. In order to suppress the rope with precession and a swirl component in the tube, the use of anti-swirl fins was investigated in a previous study. However, vortex rope generation still occurred near the cone of the tube. In this study, unsteady-state Reynolds-averaged Navier–Stokes analyses were conducted with a scale-adaptive simulation shear stress transport turbulence model. This model was used to observe the effects of the injection in the draft tube on the unsteady internal flow and pressure phenomena considering both active and passive suppression methods. The air injection affected the generation and suppression of the vortex rope and swirl component depending on the flow rate of the air. In addition, an injection level of 0.5%Q led to a reduction in the maximum unsteady pressure characteristics.


Energies ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7626
Author(s):  
Tao Guo ◽  
Lihui Xu ◽  
Wenquan Wang

The inter-blade passage vortex, the vortex rope of the draft tube, and the vortex in the guide apparatus are the characteristics of flow instability of the Francis turbine, which may lead to fatigue failure in serious cases. In the current study, in order to accurately capture the transient turbulent characteristics of flow under different conditions and fully understand the flow field and vortex structure, we conduct a simulation that adopts sliding grid technology and the large-eddy simulation (LES) method based on the wall-adapting local eddy viscosity (WALE) model. Using the pressure iso-surface method, the Q criterion, and the latest third-generation Liutex vortex identification method, this study analyzes and compares the inter-blade passage vortex, the vortex rope of the draft tube, and the outflow and vortex in the guide apparatus, focusing on the capture ability of flow field information by various vortex identification methods and the unique vortex structure under the condition of a small opening. The results indicate that the dependence of Liutex on the threshold is small, and the scale range of the flow direction vortex captured by Liutex is wider, but the ability of the spanwise vortex is relatively weak. The smaller the opening, the more disorderly the vortexes generated in each component and the more unstable the flow field. In the draft tube, the original shape of the vortex rope is destroyed due to the interaction between vortexes. Under the condition of a small opening, an inter-blade passage vortex is generated, affecting the efficient and stable operation of the turbine.


Sign in / Sign up

Export Citation Format

Share Document