Effect of Slot Injection and Effusion Array on the Liner Heat Transfer Coefficient of a Scaled Lean Burn Combustor With Representative Swirling Flow

Author(s):  
Antonio Andreini ◽  
Riccardo Becchi ◽  
Bruno Facchini ◽  
Alessio Picchi ◽  
Fabio Turrini

International standards regarding polluting emissions from civil aircraft engines are becoming gradually even more stringent. Nowadays, the most prominent way to meet the target of reducing NOx emissions in modern aero-engine combustors is represented by lean burn technology. Swirl injectors are usually employed to provide the dominant flame stabilization mechanism coupled to high efficiency fuel atomization solutions. These systems generate very complex flow structures such as recirculations, vortex breakdown and processing vortex core, that affect the distribution and therefore the estimation of heat loads on the gas side of the liner as well as the interaction with the cooling system flows. The main purpose of the present work is to provide detailed measurements of Heat Transfer Coefficient (HTC) on the gas side of a scaled combustor liner highlighting the impact of the cooling flows injected through a slot system and an effusion array. Furthermore, for a deeper understanding of the interaction phenomena between gas and cooling flows, a standard 2D PIV (Particle Image Velocimetry) technique has been employed to characterize the combustor flow field. The experimental arrangement has been developed within EU project LEMCOTEC and consists of a non-reactive three sectors planar rig installed in an open loop wind tunnel. Three swirlers, replicating the real geometry of a GE Avio PERM (Partially Evaporated and Rapid Mixing) injector technology, are used to achieve representative swirled flow conditions in the test section. The effusion geometry is composed by a staggered array of 1236 circular holes with an inclination of 30deg, while the slot exit has a constant height of 5mm. The experimental campaign has been carried out using a TLC (Thermochromic Liquid Crystals) steady state technique with a thin Inconel heating foil and imposing several cooling flow conditions in terms of slot coolant consumption and effusion pressure drop. A data reduction procedure has been developed to take into account the non-uniform heat generation and the heat loss across the liner plate. Results, in terms of 2D maps and averaged distributions of HTC have been supported by flow field measurements with 2D PIV technique focussed on the corner recirculation region.

Author(s):  
Antonio Andreini ◽  
Bruno Facchini ◽  
Riccardo Becchi ◽  
Alessio Picchi ◽  
Fabio Turrini

International standards regarding polluting emissions from civil aircraft engines are becoming gradually even more stringent. Nowadays, the most prominent way to meet the target of reducing NOx emissions in modern aero-engine combustors is represented by lean-burn technology. Swirl injectors are usually employed to provide the dominant flame stabilization mechanism coupled to high-efficiency fuel atomization solutions. These systems generate very complex flow structures, such as recirculations, vortex breakdown, and processing vortex core, which affect the distribution and therefore the estimation of heat loads on the gas side of the liner as well as the interaction with the cooling system flows. The main purpose of the present work is to provide detailed measurements of heat transfer coefficient (HTC) on the gas side of a scaled combustor liner highlighting the impact of the cooling flows injected through a slot system and an effusion array. Furthermore, for a deeper understanding of the interaction phenomena between gas and cooling flows, a standard two-dimensional (2D) particle image velocimetry (PIV) technique has been employed to characterize the combustor flow field. The experimental arrangement has been developed within EU project LEMCOTEC and consists of a nonreactive three sectors planar rig installed in an open-loop wind tunnel. Three swirlers, replicating the real geometry of a GE Avio partially evaporated and rapid mixing (PERM) injector technology, are used to achieve representative swirled flow conditions in the test section. The effusion geometry is composed by a staggered array of 1236 circular holes with an inclination of 30 deg, while the slot exit has a constant height of 5 mm. The experimental campaign has been carried out using a thermochromic liquid crystals (TLCs) steady-state technique with a thin Inconel heating foil and imposing several cooling flow conditions in terms of slot coolant consumption and effusion pressure drop. A data reduction procedure has been developed to take into account the nonuniform heat generation and the heat loss across the liner plate. Results in terms of 2D maps and averaged distributions of HTC have been supported by flow field measurements with 2D PIV technique focussed on the corner recirculation region.


Author(s):  
Vinod U. Kakade ◽  
Steven J. Thorpe ◽  
Miklós Gerendás

The thermal management of aero gas turbine engine combustion systems commonly employs effusion-cooling in combination with various cold-side convective cooling schemes. The combustor liner incorporates many small holes which are usually set in staggered arrays and at a shallow angle to the cooled surface; relatively cold compressor delivery air is then allowed to flow through these holes to provide the full-coverage film-cooling effect. The efficient design of such systems requires robust correlations of film-cooling effectiveness and heat transfer coefficient at a range of aero-thermal conditions, and the use of appropriately validated computational models. However, the flow conditions within a combustor are characterised by particularly high turbulence levels and relatively large length scales. The experimental evidence for performance of effusion-cooling under such flow conditions is currently sparse. The work reported here is aimed at quantifying typical effusion-cooling performance at a range of combustor relevant free-stream conditions (high turbulence), and also to assess the importance of modeling the coolant to free-stream density ratio. Details of a new laboratory wind-tunnel facility for the investigation of film-cooling at high turbulence levels are reported. For a typical combustor effusion geometry that uses cylindrical holes, spatially resolved measurements of adiabatic effectiveness, heat transfer coefficient and net heat flux reduction are presented for a range of blowing ratios (0.48 to 2), free-stream turbulence conditions (4 and 22%) and density ratios (0.97 and 1.47). The measurements reveal that elevated free-stream turbulence impacts on both the adiabatic effectiveness and heat transfer coefficient, although this is dependent upon the blowing ratio being employed and particularly the extent to which the coolant jets detach from the surface. At low blowing ratios the presence of high turbulence levels causes increased lateral spreading of the coolant adjacent to the injection points, but more rapid degradation in the downstream direction. At high blowing ratios, high turbulence levels cause a modest increase in effectiveness due to turbulent transport of the detached coolant fluid. Additionally, the augmentation of heat transfer coefficient caused by the coolant injection is seen to be increased at high free-stream turbulence levels.


Author(s):  
AS Sabu ◽  
Joby Mackolil ◽  
B Mahanthesh ◽  
Alphonsa Mathew

The study focuses on the aggregation kinematics in the quadratic convective magneto-hydrodynamics of ethylene glycol-titania ([Formula: see text]) nanofluid flowing through an inclined flat plate. The modified Krieger-Dougherty and Maxwell-Bruggeman models are used for the effective viscosity and thermal conductivity to account for the aggregation aspect. The effects of an exponential space-dependent heat source and thermal radiation are incorporated. The impact of pertinent parameters on the heat transfer coefficient is explored by using the Response Surface Methodology and Sensitivity Analysis. The effects of several parameters on the skin friction and heat transfer coefficient at the plate are displayed via surface graphs. The velocity and thermal profiles are compared for two physical scenarios: flow over a vertical plate and flow over an inclined plate. The nonlinear problem is solved using the Runge–Kutta-based shooting technique. It was found that the velocity profile significantly decreased as the inclination of the plate increased on the other hand the temperature profile improved. The heat transfer coefficient decreased due to the increase in the Hartmann number. The exponential heat source has a decreasing effect on the heat flux and the angle of inclination is more sensitive to the heat transfer coefficient than other variables. Further, when radiation is incremented, the sensitivity of the heat flux toward the inclination angle augments at the rate 0.5094% and the sensitivity toward the exponential heat source augments at the rate 0.0925%. In addition, 41.1388% decrement in wall shear stress is observed when the plate inclination is incremented from [Formula: see text] to [Formula: see text].


Author(s):  
Ribhu Bhatia ◽  
Sambit Supriya Dash ◽  
Vinayak Malhotra

Abstract Systematic experimentation was carried out on forced convection heat transfer apparatus under varying non-linear flow conditions to understand the energy transfer as heat, with the purpose of enhancing performance of numerous engineering applications. Plate orientations, types of enclosures (solid, meshed, perforated), flow velocity variations etc. are taken as governing parameters to effect convective heat transfer phenomenon which is perceived as deviations in value of heat transfer coefficient. RV zonal system is utilized to simplify the fundamental understanding of heat transfer coefficient variation with surface orientation under varying flow field. The objectives of this work are as follows: 1) To establish relative effectiveness of forced convective heat transfer under varying flow field. 2) To investigate the implications of varying shapes and sizes of perforations on confined forced convective heat transfer. To understand the controlling mechanism and role of key controlling parameters.


Acoustics ◽  
2020 ◽  
Vol 2 (3) ◽  
pp. 524-538
Author(s):  
Keqi Hu ◽  
Yuanqi Fang ◽  
Yao Zheng ◽  
Gaofeng Wang ◽  
Stéphane Moreau

As an indirect noise source generated in the combustion chamber, entropy waves are widely prevalent in modern gas turbines and aero-engines. In the present work, the influence of entropy waves on the downstream flow field of a turbine guide vane is investigated. The work is mainly based on a well-known experimental configuration called LS89. Two different turbulence models are used in the simulations which are the standard k-ω model and the scale-adaptive simulation (SAS) model. In order to handle the potential transition issue, Menter’s ð-Reθ transition model is coupled with both models. The baseline cases are first simulated with the two different turbulence models without any incoming perturbation. Then one forced case with an entropy wave train set at the turbine inlet at a given frequency and amplitude is simulated. Results show that the downstream maximum Mach number is rising from 0.98 to 1.16, because the entropy waves increase the local temperature of the flow field; also, the torque of the vane varies as the entropy waves go through, the magnitude of the oscillation is 7% of the unforced case. For the wall (both suction and pressure side of the vane) heat transfer, the entropy waves make the maximum heat transfer coefficient nearly twice as the large at the leading edge, while the minimum heat transfer coefficient stays at a low level. As for the averaged normalized heat transfer coefficient, a maximum difference of 30% appears between the baseline case and the forced case. Besides, during the transmission process of entropy waves, the local pressure fluctuates with the wake vortex shedding. The oscillation magnitude of the pressure wave at the throat is found to be enhanced due to the inlet entropy wave by applying the dynamic mode decomposition (DMD) method. Moreover, the transmission coefficient of the entropy waves, and the reflection and transmission coefficients of acoustic waves are calculated.


Author(s):  
Quanhong Xu ◽  
Chi Zhang ◽  
Yuzhen Lin ◽  
Gaoen Liu

The present study is conducted to investigate the characteristics of the flow field and heat transfer in an impingement/effusion cooling scheme for gas turbine combustor liner. It is designed to provide an insight, through the study of the flow field, into the physical mechanisms responsible for the enhanced impingement heat transfer near the effusion hole entrance. In this impingement/effusion cooling scheme, the angle between the impingement hole and effusion hole and the wall surface are 90 deg and 30 deg respectively. The square arrays of impingement/effusion holes are used with equal numbers of holes offset half a pitch relative to each plate so that an impingement jet is located on the center of each four effusion holes and vice versa. The flow field of the double skin wall space is described by the way of Particle Image Velocimetry (PIV). Two kinds of target plates, with and without effusion holes, are used in the impingement heat transfer study. Through changing the impingement Reynolds and the impingement gap, the change of the impingement heat transfer coefficient on the target plates is investigated. The impingement heat transfer test results show that the impingement heat transfer is enhanced near the entrance of the effusion holes, which could fully explain the feature of the impingement heat transfer coefficient on the target plate.


Author(s):  
Michael Maurer ◽  
Uwe Ruedel ◽  
Michael Gritsch ◽  
Jens von Wolfersdorf

An experimental study was conducted to determine the heat transfer performance of advanced convective cooling techniques at the typical conditions found in a backside cooled combustion chamber. For these internal cooling channels, the Reynolds number is usually found to be above the Reynolds number range covered by available databases in the open literature. As possible candidates for an improved convective cooling configuration in terms of heat transfer augmentation and acceptable pressure drops, W-shaped and WW-shaped ribs were considered for channels with a rectangular cross section. Additionally, uniformly distributed hemispheres were investigated. Here, four different roughness spacings were studied to identify the influence on friction factors and the heat transfer enhancement. The ribs and the hemispheres were placed on one channel wall only. Pressure losses and heat transfer enhancement data for all test cases are reported. To resolve the heat transfer coefficient, a transient thermocromic liquid crystal technique was applied. Additionally, the area-averaged heat transfer coefficient on the W-shaped rib itself was observed using the so-called lumped-heat capacitance method. To gain insight into the flow field and to reveal the important flow field structures, numerical computations were conducted with the commercial code FLUENT™.


Author(s):  
A. Mehdizadeh ◽  
S. A. Sherif ◽  
W. E. Lear

A fundamental study of heat transfer characteristics of two-phase slug flow in microchannels is carried out employing the Volume-of-Fluid (VOF) method. Despite of the fact that numerical simulations of two-phase flows in microchannels have been attempted by many investigators, most efforts seem to have failed in correctly capturing the flow physics, especially those pertaining to the slug flow regime characteristics. The presence of a thin liquid film in the order of 10 μm around the bubble is a contributing factor to the above difficulty. Typically, liquid films have a significant effect on the flow field and heat transfer characteristics. In the simulations reported in this paper, the film is successfully captured and a very high local convective heat transfer coefficient is observed in the film region. A strong coupling between the conductive heat transfer in the solid wall and the convective heat transfer in the flow field is observed and characterized. Results showed that unsteady heat transfer through the solid wall in the axial direction is comparable to that in the radial direction. Results also showed that a fully developed condition could be achieved fairly quickly compared to single-phase flows. The fully developed condition is defined based on the Peclet number (Pe) and a dimensionless length of the liquid slug. Local and time-averaged Nusselt numbers for slug flows are reported for the first time. It was found that significant improvements in the heat transfer coefficient could be achieved by short slugs where the Nu number was found to be 610% higher than in single-phase flows. The study revealed new findings related to slug flow heat transfer in microchannels with constant wall heat flux.


Sign in / Sign up

Export Citation Format

Share Document