Mathematical Optimization of Electronic Enclosures

Author(s):  
D. J. De Kock ◽  
M. Nagulapally ◽  
J. A. Visser ◽  
R. Nair ◽  
J. Nigen

The thermal design of electronic enclosures is becoming more important as the demand for smaller, lighter systems with better performance increases. The limiting factor on the lifetime of these systems is the maximum temperature of the electronic components. Nowadays in some systems, the thermal design is the limiting factor for performance increases. A simple yet effective design method that yields optimum designs is therefore required to design these systems. Traditionally, experimental methods were used in the design of electronic enclosures. More recently Computational Fluid Dynamics (CFD) has established itself as a viable alternative to reduce the number of experimentation required, resulting in a reduction in the time scales and cost of the design process. The CFD process is usually applied on a trial and error basis and relies heavily on the insight and experience of the designer to improve designs. Even an experienced designer will only be able to improve the design and does not necessarily guarantee optimum results. A more efficient design method is to combine a mathematical optimizer with CFD. In this study the mathematical optimization method, DYNAMIC-Q, is linked with the commercial CFD package, Icepak to optimize different electronic enclosures. The method is applied to the following design situations commonly found in electronics enclosures. The first case is that of the optimization outlet grille of a telecommunications rack to reduce the electromagnetic interference without exceeding a specified temperature in the rack. The second case involves the optimum placement of electronic components on a printed circuit board to minimize the maximum temperatures of the components. The third case deals with flow through an electronic enclosure cooled by fans placed on the wall of the enclosures. The geometrical arrangement of boards and components on the boards in these enclosures might result in unequal flow distribution between the boards. For this purpose air flow filters of varying free-area ratios are used to make the flow rates between the boards more uniform. The free-area ratios of three filters are determined in order to maximize the total flow rate through system with the added constraint that the flow rates through each of the three filters are within 5% of each other. The last case deals with flow through a simplified notebook where the CPU temperature is minimized by changing the position of two exhaust fans. The study shows that mathematical optimization is a powerful tool that can be combined with CFD to yield optimum designs.

The friction and friction factors are critical factors in flow through pipes, and heat ex-changer etc. The minimal friction is not only beneficial for pumping cost perspective, but also it reduces the loss of energy. All experimental tests were performed in accordance to Taguchi L9 orthogonal array on cast iron, aluminum, and copper pipes to study the effect of variations of viscosity, flow rates, and pipe materials on the friction factor.


1975 ◽  
Vol 40 (11) ◽  
pp. 3315-3318 ◽  
Author(s):  
M. Rylek ◽  
F. Kaštánek ◽  
L. Nývlt ◽  
J. Kratochvíl
Keyword(s):  
Gas Flow ◽  

Energies ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2796
Author(s):  
Andrzej Osuch ◽  
Ewa Osuch ◽  
Stanisław Podsiadłowski ◽  
Piotr Rybacki

In the introduction to this paper, the characteristics of Góreckie lake and the construction and operation of the wind-driven pulverizing aerator are presented. The purpose of this manuscript is to determine the efficiency of the pulverizing aerator unit in the windy conditions of Góreckie Lake. The efficiency of the pulverization aerator depends on the wind conditions at the lake. It was necessary to conduct thorough research to determine the efficiency of water flow through the pulverization segment (water pump). It was necessary to determine the rotational speed of the paddle wheel, which depended on the average wind speed. Throughout the research period, measurements of hourly average wind speed were carried out. It was possible to determine the efficiency of the machine by developing a dedicated mathematical model. The latest method was used in the research, consisting of determining the theoretical volumetric flow rates of water in the pulverizing aerator unit, based on average hourly wind speeds. Pulverization efficiency under the conditions of Góreckie Lake was determined based on 6600 average wind speeds for spring, summer and autumn, 2018. Based on the model, the theoretical efficiency of the machine was calculated, which, under the conditions of Góreckie Lake, amounted to 75,000 m3 per year.


Computation ◽  
2021 ◽  
Vol 9 (3) ◽  
pp. 27
Author(s):  
Nattakarn Numpanviwat ◽  
Pearanat Chuchard

The semi-analytical solution for transient electroosmotic flow through elliptic cylindrical microchannels is derived from the Navier-Stokes equations using the Laplace transform. The electroosmotic force expressed by the linearized Poisson-Boltzmann equation is considered the external force in the Navier-Stokes equations. The velocity field solution is obtained in the form of the Mathieu and modified Mathieu functions and it is capable of describing the flow behavior in the system when the boundary condition is either constant or varied. The fluid velocity is calculated numerically using the inverse Laplace transform in order to describe the transient behavior. Moreover, the flow rates and the relative errors on the flow rates are presented to investigate the effect of eccentricity of the elliptic cross-section. The investigation shows that, when the area of the channel cross-sections is fixed, the relative errors are less than 1% if the eccentricity is not greater than 0.5. As a result, an elliptic channel with the eccentricity not greater than 0.5 can be assumed to be circular when the solution is written in the form of trigonometric functions in order to avoid the difficulty in computing the Mathieu and modified Mathieu functions.


2020 ◽  
Vol 319 ◽  
pp. 02004
Author(s):  
Muhammad Akif Rahman ◽  
Md Badrath Tamam ◽  
Md Sadman Faruque ◽  
A.K.M. Monjur Morshed

In this paper a numerical analysis of three-dimensional laminar flow through rectangular channel heat sinks of different geometric configuration is presented and a comparison of thermal performance among the heat sinks is discussed. Liquid water was used as coolant in the aluminum made heat sink with a glass cover above it. The aspect ratio (section height to width) of rectangular channels of the mini-channel heat sink was 0.33. A heat flux of 20 W/cm2 was continuously applied at the bottom of the channel with different inlet velocity for Reynold’s number ranging from 150 to 1044. Interconnectors and obstacles at different positions and numbers inside the channel were introduced in order to enhance the thermal performance. These modifications cause secondary flow between the parallel channels and the obstacles disrupt the boundary layer formation of the flow inside the channel which leads to the increase in heat transfer rate. Finally, Nusselt number, overall thermal resistance and maximum temperature of the heat sink were calculated to compare the performances of the modified heat sinks with the conventional mini channel heat sink and it was observed that the heat sink with both interconnectors and obstacles enhanced the thermal performance more significantly than other configurations. A maximum of 36% increase in Nusselt number was observed (for Re =1044).


1952 ◽  
Vol 30 (4) ◽  
pp. 348-371 ◽  
Author(s):  
E. A. Flood ◽  
R. H. Tomlinson ◽  
A. E. Leger

The flow rates of the vapors of benzene, ethyl chloride, diethyl ether, methanol, and water through activated carbon rods have been found to exceed, considerably, flow rates calculated by classical equations. The excess flow rates show maxima in widely different relative pressure regions and are ascribed to flow of adsorbed material. An empirical equation is presented which correlates the observed flow rates with relevant adsorption isotherms. Classical equations of flow through elliptical and rectangular pipes are discussed with reference to flow through fine-grained porous materials. It is shown that equations of the Adzumi type are roughly valid as applied to fine-grained porous bodies, but that without a knowledge of the frequency distributions of pore sizes and shapes, flow data cannot be related to pore dimensions in any literal sense. End effects are discussed.


2001 ◽  
Author(s):  
David P. Haack ◽  
Kenneth R. Butcher ◽  
T. Kim ◽  
T. J. Lu

Abstract An overview of open cell metal foam materials with application to advanced heat exchange devices is presented. The metal foam materials considered consist of interconnected cells in a random orientation. Metal foam materials, manufacture and fabrication into complex heat exchange components are described. Experiments with flat foam panels brazed to copper sheets shows increasing heat removal effectiveness with decreasing product pore size at equivalent coolant flow rates. However, the high-pressure drop associated with flow through small pore-size material makes the use of larger pore size material more attractive.


Author(s):  
A.C. Fox ◽  
T.W. Clyne

Abstract A simple test procedure, based on steady state flow through a membrane, has been developed for measurement of the gas permeability of specimens over a range of temperature. The reliability of this equipment has been verified by testing solid disks containing single perforations and comparing the measured flow rates with those expected on the basis of laminar flow. Coatings of yttria-stabilised zirconia have been produced by plasma spraying in vacuum and in air. The specific permeability of these coatings has been measured at temperatures ranging up to 600°C, using hydrogen gas. It has been found that permeability is increased for coatings produced with longer stand-off distances and at higher pressures. Porosity levels have been measured using densitometry and microstructural features have been examined using SEM. A model has been developed for prediction of the permeability from such microstructural features, based on percolation theory. Agreement between predicted and measured permeabilities is good, although it is clear that more comprehensive data are needed in order to validate the model systematically.


Sign in / Sign up

Export Citation Format

Share Document