scholarly journals Secondary Stability of a Composite Biomimetic Cementless Hip Stem

Author(s):  
Christiane Caouette ◽  
Martin N. Bureau ◽  
L’Hocine Yahia

Total hip replacement is one of the most successful and frequent surgery in the world; over a million of these procedures are performed every year, and the numbers are growing with the ageing of the general population. The patients who receive these implants also are younger nowadays. Major problems however still subsist with traditional hip stems: aseptic loosening is a common cause of revision surgery. The main causes of aseptic loosening are both mechanical and biological in origin. Mechanical causes include stress shielding and micromotions at bone-implant interface, and biological causes are mainly osteolysis triggered by wear debris formation and bone remodeling. To remedy the mechanical issues, a biomimetic concept was developed (patent pending): an osseointegrated stem with mechanical properties close to those of the surrounding bone would avoid both stress shielding and micromotions phenomena. To evaluate this concept, a finite element model (FEM) was developed and used to simulate bone resorption, stress shielding and micromotions [1]. The preliminary results were promising as those problems were significantly reduced with the new prosthesis, but the model still remained to be proved accurate; its bone-implant interface was of particular interest because of its decisive influence on micromotions.

Author(s):  
Bahram Raad ◽  
Narges Shayesteh Moghaddam ◽  
Mohammad Elahinia

The aim of this article is to investigate the effect of two different fixation hardware materials on bone remodeling after a mandibular reconstruction surgery and to restore the mandible’s function, healthy appearance, mastication, swallowing, breathing, and speech. The hypothesis is that using fixation hardware with stiffness close to that of the surrounding bone will result in a more successful healing process in the mandible bone. The finite element model includes the material properties and forces of the cancellous bone, cortical bone, ligaments, muscles, and teeth. The reconstruction surgery is modeled by including the fixation hardware and the grafted bone. In the sectioned mandible, to best mimic the geometry of the mandible, two single barrel grafts are placed at the top of each other to form a double barrel graft set. Two different materials were used as the mandibular fixation parts, stiff Ti-6Al-4V, and porous superelastic Nickel-Titanium (NiTi) alloys. A comparison of these two alloys demonstrates that using porous NiTi alloy as the fixation part results in a faster healing pace. Furthermore, the density distribution in the mandibular bone after the healing process is more similar to the normal mandible density distribution. The simulations results indicate that the porous superelastic NiTi fixation hardware transfers and distributes the existing forces on the mandible bone more favorably. The probability of stress shielding and/or stress concentration decrease. This type of fixation hardware, therefore, is more appropriate for mandible bone reconstruction surgery.


Designs ◽  
2020 ◽  
Vol 4 (2) ◽  
pp. 12 ◽  
Author(s):  
Morassa Jafari Chashmi ◽  
Alireza Fathi ◽  
Masoud Shirzad ◽  
Ramazan-Ali Jafari-Talookolaei ◽  
Mahdi Bodaghi ◽  
...  

One of the most important problems of total hip replacement is aseptic loosening of the femoral component, which is related to the changes of the stress distribution pattern after implantation of the prosthesis. Stress shielding of the femur is recognized as a primary factor in aseptic loosening of hip replacements. Utilizing different materials is one of the ordinary solutions for that problem, but using functionally graded materials (FGMs) could be better than the conventional solutions. This research work aims at investigating different porous FGM implants and a real femoral bone by a 3D finite element method. The results show that a neutral functionally graded prosthesis cannot extraordinarily make changes in the stress pattern of bone and prosthesis, but an increasing functionally graded prosthesis leads a lower level of stress in the prosthesis, and a decreasing functionally graded prosthesis can properly reduce the stress shielding among these three architectures. Due to the absence of similar results in the specialized literature, this paper is likely to fill a gap in the state-of-the-art bio-implants, and provide pertinent results that are instrumental in the design of porous femoral prostheses under normal walking loading conditions.


Author(s):  
Aminatun ◽  
Dyah Hikmawati ◽  
M. Yasin

Total hip replacement (THR) that is widely used today is the cemented type, which its application will lead to aseptic loosening. To avoid the occurrence of aseptic loosening, THR coated with hydroxyapatite (HA) is required because HA is osteoconductive which can stimulate the growth of osteoblasts. This study aims to determine the optimum sinter temperature which produce HA coating suitable as implant material. To achieve these objectives, the electrophoretic deposition (EPD) conducted coating method at concentrations of HA 1,0M, voltage of 100V for 30 minutes and then sintered at temperatures are 550°C, 700°C and 900°C respectively detention for 10 minutes. The results showed that the treatment of sintering after the coating process through the EPD method affect the characteristics of the layer thus formed. Sintering process affects the crystallinity of the HA layer. The higher the sintering temperature the higher its crystallinity. The higher the crystallinity the stronger the HA layer attached to the substrate cobalt alloy. Based on this research, the selected sintering temperature was 900 °C for 10 minutes which produced a layer of HA with the best characteristics that meet the standard of implant prosthesis, the crystallinity of 89.4%, thick layer of 70.80 ± 4.18 μm, adhesion strength of 21.87 ± 0.23 MPa, the corrosion rate of 0.025 mpy and 70.3% cell viability.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Rikeen D. Jobanputra ◽  
Jack Hayes ◽  
Sravani Royyuru ◽  
Marc A. Masen

AbstractThe use of close-fitting PPE is essential to prevent exposure to dispersed airborne matter, including the COVID-19 virus. The current pandemic has increased pressure on healthcare systems around the world, leading to medical professionals using high-grade PPE for prolonged durations, resulting in device-induced skin injuries. This study focuses on computationally improving the interaction between skin and PPE to reduce the likelihood of discomfort and tissue damage. A finite element model is developed to simulate the movement of PPE against the face during day-to-day tasks. Due to limited available data on skin characteristics and how these vary interpersonally between sexes, races and ages, the main objective of this study was to establish the effects and trends that mask modifications have on the resulting subsurface strain energy density distribution in the skin. These modifications include the material, geometric and interfacial properties. Overall, the results show that skin injury can be reduced by using softer mask materials, whilst friction against the skin should be minimised, e.g. through use of micro-textures, humidity control and topical creams. Furthermore, the contact area between the mask and skin should be maximised, whilst the use of soft materials with incompressible behaviour (e.g. many elastomers) should be avoided.


2011 ◽  
Vol 11 (01) ◽  
pp. 55-72 ◽  
Author(s):  
DESMOND Y. R. CHONG ◽  
ULRICH N. HANSEN ◽  
ANDREW A. AMIS

Aseptic loosening caused by mechanical factors is a recognized failure mode for tibial components of knee prostheses. This parametric study investigated the effects of prosthesis fixation design changes, which included the presence, length and diameter of a central stem, the use of fixation pegs beneath the tray, all-polyethylene versus metal-backed tray, prosthesis material stiffness, and cement mantle thickness. The cancellous bone compressive stresses and bone–cement interfacial shear stresses, plus the reduction of strain energy density in the epiphyseal cancellous bone, an indication of the likelihood of component loosening, and bone resorption secondary to stress shielding, were examined. Design features such as longer stems reduced bone and bone–cement interfacial stresses thus the risk of loosening is potentially minimized, but at the expense of an increased tendency for bone resorption. The conflicting trend suggested that bone quality and fixation stability have to be considered mutually for the optimization of prosthesis designs. By comparing the bone stresses and bone–cement shear stresses to reported fatigue strength, it was noted that fatigue of both the cancellous bone and bone–cement interface could be the driving factor for long-term aseptic loosening for metal-backed tibial trays.


1994 ◽  
Vol 76-B (1) ◽  
pp. 60-67 ◽  
Author(s):  
AS Shanbhag ◽  
JJ Jacobs ◽  
TT Glant ◽  
JL Gilbert ◽  
J Black ◽  
...  

2018 ◽  
Vol 3 (3) ◽  
pp. 2473011418S0011
Author(s):  
Daniel Sturnick ◽  
Guilherme Saito ◽  
Jonathan Deland ◽  
Constantine Demetracopoulos ◽  
Xiang Chen ◽  
...  

Category: Ankle Arthritis Introduction/Purpose: Loosening of the tibial component is the primary failure mode in total ankle arthroplasty (TAA). The mechanics of the tibial component loosening has not been fully elucidated. Clinically observed radiolucency and cyst formation in the periprosthetic bone may be associated with unfavorable load sharing at and adjacent to the tibial bone-implant interface contributory to implant loosening. However, no study has fully investigated the load transfer from the tibial component to the bone under multiaxial loads in the ankle. The objective of this study was to utilize subject-specific finite element (FE) models to investigate the load transfer through tibial bone-implant interface, as well as periprosthetic bone strains under simulated multiaxial loads. Methods: Bone-implant FE models were developed from CT datasets of three cadaveric specimens that underwent TAA using a modern fixed-bearing tibial implant (a cobalt-chrome tray with a polyethylene bearing, Salto Talaris, Integra LifeSciences). Implant placement was estimated from the post-operative CT scans. Bone was modeled as isotropic elastic material with inhomogeneous Young’s modulus (determined from CT Hounsfield units) and a uniform Poisson’s ratio of 0.3. The tibial tray (Young’s modulus: 200,000 MPa, Poisson’s ratio: 0.3) and the polyethylene bearing (Young’s modulus: 600 MPa, Poisson’s ratio: 0.4) were modeled as isotropic elastic. A 100-N compressive force, a 300-N anterior force, and a 3-Nm moment were applied to two literature based loading regions on the surface of the polyethylene bearing. The proximal tibia was fixed in all directions. The bone-implant contact was modeled as frictional with a coefficient of 0.7, whereas the polyethylene bearing was bonded to the tray. Results: Along the long axis of the tibia, load was transferred to the bone primarily through the flat bone-contacting base of the tibial tray and the cylindrical top of the keel, little amount of load was transferred to the bone between those two features (Fig. 1A). Low strain was observed in bone regions medial and lateral to the keel of the tibial tray, where bone cysts were often observed clinically (Fig. 1A). On average, approximated 70% of load was transferred through the anterior aspect of the tibial tray at the flat bone-contacting base, which corresponded to the relatively high bone strain adjacent to the implant edge in the anterior bone-implant interface (Fig. 1B). Conclusion: Our results demonstrated a two-step load transfer pattern along the long axis of the tibia, revealing regions with low bone strain peripheral to the keel indicative to stress shielding. Those regions were consistent with the locations of bone cysts observed clinically, which may be explained by the stress shielding associated remodeling of bone. These findings could also describe the mechanism of implant loosening and failure. Future studies may use our model to simulate more loading scenarios, as well as different implant placement and design, to identify means to optimize load transfer to the bone and prevent stress shielding.


Author(s):  
Daniela Medrano-David ◽  
Aura Maria Lopera ◽  
Martha Elena Londoño ◽  
Pedronel Araque-Marín

The occurrence of bone-related disorders and diseases has increased dramatically in recent years around the world. Demineralized bone matrix (DBM) has been widely used as a bone implant due to its osteoinduction and bioactivity. However, the use of DBM is limited because it is a particulate material, which makes it difficult to manipulate and implant with precision, in addition, these particles are susceptible to migrate to other sites. To address this situation, DBM is commonly incorporated into a variety of carriers. An injectable scaffold has advantages over bone grafts or preformed scaffolds, such as the ability to flow and fill the bone defect. The aim of this research is to develop a DBM carrier with such viscoelastic properties to obtain an injectable bone substitute (IBS). The DBM carrier developed consisted of a PVA/glycerol network cross-linked with borax and reinforced with CaCO3 as a pH neutralizer, porosity generator, and source of Ca. The physicochemical properties were determined by the injectability test, FTIR, SEM, and TGA. Porosity, degradation, bioactivity, possible cytotoxic effect, and proliferation in osteoblasts were also determined. The results show that the developed material has great potential to be used in bone tissue regeneration