Monitoring of Fish Tank Oxygen Concentration Using a Digital Recorder

1971 ◽  
Vol 28 (8) ◽  
pp. 1196-1197 ◽  
Author(s):  
K. R. Scott

A method for monitoring fish tank oxygen concentrations at 10-min intervals is described. The millivolt output from a temperature-compensated oxygen meter is connected to a clocked digital datalogger system having a perforated paper tape output. Results from two widely different sets of operating conditions are analysed and automatically plotted using a prewritten computer program.


2012 ◽  
Vol 610-613 ◽  
pp. 1473-1477 ◽  
Author(s):  
Chuan Min Chen ◽  
Li Xing Jiang ◽  
Song Tao Liu ◽  
Yu Ze Jiang

Secondary atmospheric pollutions may result from wet flue gas desulfurization (WFGD) systems caused by the reduction of Hg2+to Hg0and lead to a damping of the co-benefit mercury removal efficiency by WFGD systems. The effects of the operating conditions, which included the pH, temperature, and oxygen concentrations, on Hg0re-emission inhibition efficiency by DTCR from WFGD liquors was carried out. The established data reflected an outstanding performance on the Hg0re-emission inhibition from the simulated WFGD liquors by adding DTCR. Our data suggested that a concentration of 0.0005% (v/v) was enough for Hg0re-emission inhibition in the simulated WFGD liquors. The results also indicated that the Hg0re-emission inhibition efficiency by adding DTCR decreased as the operational temperatures increased and the Hg0re-emission inhibition efficiency increased as pH values and the oxygen concentration in the flue gas increased. The present findings could be valuable for industrial application of DTCR as a precipitant for stabilizing dissolved Hg2+to prevent re-emission of Hg0in WFGD solutions.



Author(s):  
Wanhui Zhao ◽  
Lei Zhou ◽  
Wenjin Qin ◽  
Haiqiao Wei

Large eddy simulation of n-heptane spray flames is conducted to investigate the multiple-stage ignition process under extreme (low-temperature, low oxygen, and high-temperature, high-density) conditions. At low oxygen concentrations, the first-stage ignition initiates in the fuel-rich region and then moves to stoichiometric equivalence ratio regions by decreasing the initial temperature. It is also clear that at high temperatures, high oxygen concentrations, or high densities, the reactivity of the mixture is enhanced, where high values of progress variable are observed. Analysis of key intermediate species, including acetylene (C2H2), formaldehyde (CH2O), and hydroxyl (OH) in the mixture fraction and temperature space provides valuable insights into the complex combustion process of the n-heptane spray flames under different initial conditions. The results also suggest that C2H2 appears over a wider range in the mixture fraction space at higher temperature or oxygen concentration condition, implying that it mainly forms at the fuel-rich regions. The initial oxygen concentration of the ambient gas has great influence on the formation and oxidization of C2H2, and the maximum temperature depends on the initial oxygen concentration. OH is mainly formed at the stoichiometric equivalence ratio region, which moves to high-temperature regions very quickly especially at higher oxygen concentrations. Finally, analysis of the premixed and nonpremixed combustion regimes in n-heptane spray flames is also conducted, and both premixed and nonpremixed combustion coexist in spray flames.



2020 ◽  
Vol 93 (1106) ◽  
pp. 20190702 ◽  
Author(s):  
Gabriel Adrian ◽  
Elise Konradsson ◽  
Michael Lempart ◽  
Sven Bäck ◽  
Crister Ceberg ◽  
...  

Objective: Recent in vivo results have shown prominent tissue sparing effect of radiotherapy with ultra-high dose rates (FLASH) compared to conventional dose rates (CONV). Oxygen depletion has been proposed as the underlying mechanism, but in vitro data to support this have been lacking. The aim of the current study was to compare FLASH to CONV irradiation under different oxygen concentrations in vitro. Methods: Prostate cancer cells were irradiated at different oxygen concentrations (relative partial pressure ranging between 1.6 and 20%) with a 10 MeV electron beam at a dose rate of either 600 Gy/s (FLASH) or 14 Gy/min (CONV), using a modified clinical linear accelerator. We evaluated the surviving fraction of cells using clonogenic assays after irradiation with doses ranging from 0 to 25 Gy. Results: Under normoxic conditions, no differences between FLASH and CONV irradiation were found. For hypoxic cells (1.6%), the radiation response was similar up to a dose of about 5–10 Gy, above which increased survival was shown for FLASH compared to CONV irradiation. The increased survival was shown to be significant at 18 Gy, and the effect was shown to depend on oxygen concentration. Conclusion: The in vitro FLASH effect depends on oxygen concentration. Further studies to characterize and optimize the use of FLASH in order to widen the therapeutic window are indicated. Advances in knowledge: This paper shows in vitro evidence for the role of oxygen concentration underlying the difference between FLASH and CONV irradiation.



Author(s):  
Aurel Gaba ◽  
Vasile Bratu ◽  
Dorian Musat ◽  
Ileana Nicoleta Popescu ◽  
Maria Cristiana Enescu

Abstract This paper presents solutions and the equipment for preheating combustion air from scrap aluminum melting furnaces through flue gas heat recovery. For sizing convection pre-heaters, there has been developed a mathematical model which has been transcribed into a computer program in C + +. A constructive version of the pre-heater was drawn up and a recovery heat exchanger was manufactured and mounted on an aluminum melting furnace. Both the functional parameters values and the reasons causing the pre-heater worning out, as well as the steps taken for sizing and the achievement of a new air pre-heater able to bear the operating conditions of the aluminum melting furnace are shown.



1963 ◽  
Vol 204 (1) ◽  
pp. 5-8 ◽  
Author(s):  
Kalman Greenspan ◽  
Paul F. Cranefield

The rate of oxygen uptake of quiescent Purkinje fibers of the dog's heart was determined using a flow respirometer and oxygen polarography. At ambient oxygen concentrations of 60% or higher the rate of uptake was 0.739 mm3/mg wet weight per hr at 35 C. The temperature coefficient over the range 25–35° was 2.3. The uptake was independent of the ambient oxygen concentration at oxygen concentrations equal to or greater than 60% of an atmosphere. In lower oxygen concentrations the rate of uptake was found to be depressed. The depression of uptake in the lower oxygen tensions is probably the result of diffusion limitation; it may, however, reflect dependence of resting uptake on oxygen concentration.



1995 ◽  
Vol 104 (8) ◽  
pp. 625-632 ◽  
Author(s):  
Cecilia Mattsson ◽  
Karin Magnuson ◽  
Sten Hellström

The purpose of this study was to elucidate possible relationships between the oxygen concentration of the middle ear cavity and the development of myringosclerosis. Three groups of rats with myringotomized tympanic membranes were exposed to different oxygen concentrations of 10%, 15%, and 40%, respectively, for 1 week. A fourth group was kept in ambient air. Two other groups of rats with myringotomized and intubated tympanic membranes were exposed to oxygen concentrations of 10% and 40%, respectively, for the same period of time. Otomicroscopically, all hyperoxic animals had more numerous myringosclerotic lesions compared with the ambient air group, and also displayed a pronounced hyperplasia of the keratinizing epithelium around the perforation border. By contrast, the hypoxic animals showed less pronounced myringosclerotic lesions or even completely lacked them. It is inferred that an increased oxygen concentration in the middle ear cavity will increase the likelihood of myringosclerotic deposits. The mechanism involved could be related to the formation of oxygen radicals.



1953 ◽  
Vol 26 (3) ◽  
pp. 643-654 ◽  
Author(s):  
J. Reid Shelton ◽  
William L. Cox

Abstract The over-all rate of deterioration of physical properties increases with the oxygen concentration, as would be expected from the increased rate of oxygen absorption: The nature of the deterioration resulting from a given amount of oxygen absorbed is influenced also by changes in the partial pressure of oxygen in the aging atmosphere. It appears that chain scission is favored at higher oxygen concentrations, while cross-linking becomes of greater relative importance at lower oxygen concentrations. These data suggest that R⋅ radicals are more effective than RO2⋅ radicals in reacting with double bonds to form crosslinks. Heat aging in the absence of oxygen, as observed by heating a vulcanizate in lamp-grade nitrogen, results in considerable stiffening, particularly in the case of a GR-S black stock. This effect is observed primarily in the first few hours of heating, and may account for some of the erratic behavior observed in the early stages of aging when changes in physical properties are compared on the basis of amount of oxygen absorbed. Higher oxygen concentration brings about a more rapid oxidation, and also results in a higher proportion of chain scission compared to cross-linking for a given amount of oxygen absorbed. As tensile decay is the most evident sign of deterioration of Hevea stocks, it follows that the aging behavior of natural rubber in air at normal storage temperatures will be better than that predicted by high temperature testing in oxygen. In the case of GR-S stocks, on the other hand, oxidative hardening is the most serious result of aging, and consequently, the aging behavior of GR-S stocks in air at normal storage temperatures is poorer than would be expected on the basis of comparative tests in oxygen at higher temperatures.



Author(s):  
Xiangrui Zeng ◽  
Junmin Wang

Dual-loop exhaust gas recirculation (EGR) systems can provide control authorities for adjusting the engine in-cylinder gas conditions. However, the transport delay in the EGR air-path makes some simple oxygen concentration dynamic models perform poorly under the transient operating conditions. In this paper, a dual-loop EGR air-path oxygen concentration model considering the time-varying transport delays is developed and a method to calculate the delay time based on the continuity of gas velocity is presented. Simulation validations using a high-fidelity GT-Power 1-D computational engine model show that the developed model can capture the oxygen concentration dynamics during both steady-state and transient operations.



2004 ◽  
Vol 16 (8) ◽  
pp. 787 ◽  
Author(s):  
A. E. Fischer-Brown ◽  
B. R. Lindsey ◽  
F. A. Ireland ◽  
D. L. Northey ◽  
R. L. Monson ◽  
...  

Bovine embryos were produced in vitro using a 2 × 2 design of modified medium (KSOM or SOF) and oxygen concentration (5% or 20%). Day 7 blastocysts were transferred in bulk (n = 11, on average) to recipient heifers and recovered non-surgically at Day 14. In two replications of a Latin square, eight heifers received embryos from each combination of factors. Recovered embryos were evaluated for trophoblast length and width, as well as the presence and diameter of an embryonic disc (ED). An ED was detected in a higher percentage of embryos that had been cultured in KSOM than SOF (72% v. 46%, respectively; P < 0.05). The aim of a second series of experiments was to associate Day 14 morphology with subsequent developmental capacity. In vitro-produced blastocysts were transferred (n = 17–20) on Day 7 to each of eight heifers and recovered at Day 14. Thirty-eight blastocysts were retransferred to heifers following morphological evaluation. Embryos in which an ED with no signs of degeneration had been detected maintained more pregnancies than other embryos in which an ED had either shown signs of degeneration or had not been detected (5/8 v. 2/30, respectively; P < 0.01). Further investigation into ED integrity at the elongating stage may contribute to our understanding of pregnancy establishment and maintenance.



Sign in / Sign up

Export Citation Format

Share Document