scholarly journals MRPC detector for the upgrade of BESIII E-TOF

2014 ◽  
Vol 31 ◽  
pp. 1460298
Author(s):  
Rong-Xing Yang ◽  
Yong-Jie Sun ◽  
Cheng Li

An end-cap Time-of-Flight (E-TOF) system with higher granularity and intrinsic time resolution of better than 50 ps will extend the K/pion separation (2 sigma) pT range to 1.4 GeV/c and enhance the physics capability of Beijing Spectrometer (BESIII). A R&D work was carried out aiming at upgrading the current BESIII E-TOF with the Multi-gap resistive Plate Chamber (MRPC) detector. The latest best test for the prototype MRPC, together with the custom designed Front End Electronics (FEE) and TDC boards, was performed at the BEPC E3 line in July 2012. The test results show that time resolution of less than 50 ps can be achieved with such a system.

2007 ◽  
Vol 16 (07n08) ◽  
pp. 2476-2483 ◽  
Author(s):  
◽  
MING SHAO ◽  
LIANG LI

Time-Of-Flight (TOF) based on Multi-gap Resistive Plate Chamber (MRPC) detectors have been successfully operating at the STAR experiment since 2003.2,3 The MRPC time resolution is however found to be significantly worse2 (80-90 ps) than that previously obtained in beam test (60 ps).4 In order to fully understand MRPC working principles and operating requirements, an extensive calibration study is performed using data collected by STAR in 200 GeV Au + Au collisions in 2004. The relation between MRPC timing, signal amplitude, incident angle and momentum are discussed. Contributions from tracking properties of STAR-TPC are also studied by simulation. The intrinsic time resolution of the MRPCs used in STAR-TOF, after taking all factors into consideration, is found to be in good agreement with beam test results.


1977 ◽  
Vol 145 (3) ◽  
pp. 445-451 ◽  
Author(s):  
J. Pouthas ◽  
S. Agarwal ◽  
M. Engrand ◽  
C. Pisani

2001 ◽  
Vol 16 (supp01c) ◽  
pp. 1119-1121 ◽  
Author(s):  
C. GROZIS ◽  
R. KEPHART ◽  
R. STANEK ◽  
B. KIM ◽  
D. H. KIM ◽  
...  

A Time-of-Flight detector (TOF), with a technique based on plastic scintillators and finemesh photomultipliers, has been added to the CDF-II experiment. The main physics motivation is to improve neutral B meson flavor determination by K± identification. The expected time resolution is 100 ps, which provides at least two standard deviations separation between K± and π± for momenta p < 1.6 Gev/cand better than 1.2 standard deviations separation over all momenta when combining TOF identification with dE/dx identification using the new drift chamber.


2019 ◽  
Vol 9 (01) ◽  
pp. 47-54
Author(s):  
Rabbai San Arif ◽  
Yuli Fitrisia ◽  
Agus Urip Ari Wibowo

Voice over Internet Protocol (VoIP) is a telecommunications technology that is able to pass the communication service in Internet Protocol networks so as to allow communicating between users in an IP network. However VoIP technology still has weakness in the Quality of Service (QoS). VOPI weaknesses is affected by the selection of the physical servers used. In this research, VoIP is configured on Linux operating system with Asterisk as VoIP application server and integrated on a Raspberry Pi by using wired and wireless network as the transmission medium. Because of depletion of IPv4 capacity that can be used on the network, it needs to be applied to VoIP system using the IPv6 network protocol with supports devices. The test results by using a wired transmission medium that has obtained are the average delay is 117.851 ms, jitter is 5.796 ms, packet loss is 0.38%, throughput is 962.861 kbps, 8.33% of CPU usage and 59.33% of memory usage. The analysis shows that the wired transmission media is better than the wireless transmission media and wireless-wired.


2020 ◽  
Vol 3 (1) ◽  
pp. 39-50
Author(s):  
Bernadeta Ritawati ◽  
Sri Wahyuni

This research is a quasi-experimental study that aims to determine the comparison of students' mathematical communication abilities with the cooperative learning model of the NHT and PPT media in class VII SMP Negeri 02 Ngabang. The population in this study were all students of class VII SMP 02 Ngabang consisting of 3 classes. The sample in this study was taken by using the Random Sampling Cluster technique. Class VII A as class I experimental class with 24 students and class VII B as a experimental class II with 24 students. The instruments used were pretest and posttest in the form of description. Data analysis uses the t test with a significance level of 5%. The results showed the average posttest for the NHT class was 72.5 and the average posttest for the PP class was 66.666. From the posttest hypothesis test results obtained t hitung> t tabel (1.9522> 1,667). Because t_hitung> t_tabel, H_0 is rejected and H_a is accepted. This means that students' mathematical communication skills taught with the NHT are better than using Power point media.


Materials ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 3819
Author(s):  
Ting-Hsun Lan ◽  
Yu-Feng Chen ◽  
Yen-Yun Wang ◽  
Mitch M. C. Chou

The computer-aided design/computer-aided manufacturing (CAD/CAM) fabrication technique has become one of the hottest topics in the dental field. This technology can be applied to fixed partial dentures, removable dentures, and implant prostheses. This study aimed to evaluate the feasibility of NaCaPO4-blended zirconia as a new CAD/CAM material. Eleven different proportional samples of zirconia and NaCaPO4 (xZyN) were prepared and characterized by X-ray diffractometry (XRD) and Vickers microhardness, and the milling property of these new samples was tested via a digital optical microscope. After calcination at 950 °C for 4 h, XRD results showed that the intensity of tetragonal ZrO2 gradually decreased with an increase in the content of NaCaPO4. Furthermore, with the increase in NaCaPO4 content, the sintering became more obvious, which improved the densification of the sintered body and reduced its porosity. Specimens went through milling by a computer numerical control (CNC) machine, and the marginal integrity revealed that being sintered at 1350 °C was better than being sintered at 950 °C. Moreover, 7Z3N showed better marginal fit than that of 6Z4N among thirty-six samples when sintered at 1350 °C (p < 0.05). The milling test results revealed that 7Z3N could be a new CAD/CAM material for dental restoration use in the future.


2019 ◽  
Author(s):  
Gurmukh Singh ◽  
Natasha M Savage ◽  
Brandy Gunsolus ◽  
Kellie A Foss

Abstract Objective Quick turnaround of laboratory test results is needed for medical and administrative reasons. Historically, laboratory tests have been requested as routine or STAT. With a few exceptions, a total turnaround time of 90 minutes has been the usually acceptable turnaround time for STAT tests. Methods We implemented front-end automation and autoverification and eliminated batch testing for routine tests. We instituted on-site intraoperative testing for selected analytes and employed point of care (POC) testing judiciously. The pneumatic tube system for specimen transport was expanded. Results The in-laboratory turnaround time was reduced to 45 minutes for more than 90% of tests that could reasonably be ordered STAT. With rare exceptions, the laboratory no longer differentiates between routine and STAT testing. Having a single queue for all tests has improved the efficiency of the laboratory. Conclusion It has been recognized in manufacturing that batch processing and having multiple queues for products are inefficient. The same principles were applied to laboratory testing, which resulted in improvement in operational efficiency and elimination of STAT tests. We propose that the target for in-laboratory turnaround time for STAT tests, if not all tests, be 45 minutes or less for more than 90% of specimens.


2007 ◽  
Vol 330-332 ◽  
pp. 495-498
Author(s):  
Chao Zou ◽  
Wen Jian Weng ◽  
Xu Liang Deng ◽  
Kui Cheng ◽  
Pi Yi Du ◽  
...  

Two starting collagens, sponge and floc collagen, were used to prepare collagen/tricalcium phosphate (TCP) composites. The resulting composites were porous and had 200μm pore size. However, there was a difference in the microstructure of the pore walls for the composites derived from the two collagens, the pore walls in sponge collagen/TCP composite were still porous and had 200 nm micropores size, TCP particles were trapped in collagen matrices. While floc collagen/TCP composite had smooth and dense walls in which TCP particles were embedded. The difference could be attributed to the starting collagen with different status. Sponge collagen has a soft structure, which easily becomes disassembled fibrils during alkali treatment, the disassembled fibrils are integrated again to form a dense morphology for pore walls after freeze-drying. While floc collagen has already a low disassembly degree, the alkali treatment could not be able to separate the fibrils, this remains as micropores in pore walls after freeze-drying. Both porous composites are significant in bone tissue engineering or regeneration. MTT test results showed the two composites had good cytocompatibility, and sponge collagen/TCP composite was somewhat better than floc collagen/TCP composite, which could result from that micropores derived roughness in pore walls of sponge collagen/TCP composite is suitable for cell growth.


Sign in / Sign up

Export Citation Format

Share Document