An automated simultaneous transmural cardiac mapping system

1984 ◽  
Vol 247 (4) ◽  
pp. H661-H668 ◽  
Author(s):  
F. X. Witkowski ◽  
P. B. Corr

The origin and propagation sequence of cardiac depolarization in situ requires accurate simultaneous three-dimensional information from multiple sites. Likewise, the mechanism underlying an arrhythmia can often be elucidated by determining the course of impulse propagation through the heart, particularly if information can be obtained from multiple sites simultaneously, allowing analysis of transient or rapidly occurring events. The most significant problem with obtaining such detailed continuous information is the large amount of data storage required as well as the need for rapid analysis. In the present system these problems are overcome by immediate conversion of all electrograms from analog to digital for all subsequent storage and processing. The bipolar electrogram information is acquired from 240 cardiac sites simultaneously at a sampling rate of 2 kHz with continuous and total data storage of up to 60 min. Rapid two-dimensional isochronic maps at multiple depths (effective 3-dimensional information) are presented via computer-generated interactive graphics. System design permits easy expansion to almost 2,000 simultaneous sites. Surgical electrophysiological intraoperative studies in humans are performed at an operating room located 2,000 ft from the computer facility with all communications carried by a fiber-optic link. The system allows both experimental and clinical cardiac mapping from multiple sites from a single cardiac depolarization, minimal redundancy of costly hardware, and direct rapid visualization of all original electrogram data.

2013 ◽  
Vol 753-755 ◽  
pp. 2489-2493
Author(s):  
Ai Qin Zhang ◽  
Han Cheng Liu ◽  
Yi Hu ◽  
Hang Chen ◽  
Zhi Xu

In this paper we designed a portable ECG monitoring system based on Cortex-M3. The system was composed of the microcontroller LPC1788 and the analog front-end ADS1298 which provided a low-noise, 8-channel, 24-bit delta-sigma analog-to-digital converter. The monitor used SD card for data storage and USB for data transmission, which was capable of monitoring both dynamic ECG and conventional ECG. The system could work up to 24 hours with a resolution of 24 bits and 1024Hz sampling rate. The designed system embodies several characteristics including portability, low power, large capacity, and high resolution, which are quite suitable for ECG monitoring.


Author(s):  
Robert Glaeser ◽  
Thomas Bauer ◽  
David Grano

In transmission electron microscopy, the 3-dimensional structure of an object is usually obtained in one of two ways. For objects which can be included in one specimen, as for example with elements included in freeze- dried whole mounts and examined with a high voltage microscope, stereo pairs can be obtained which exhibit the 3-D structure of the element. For objects which can not be included in one specimen, the 3-D shape is obtained by reconstruction from serial sections. However, without stereo imagery, only detail which remains constant within the thickness of the section can be used in the reconstruction; consequently, the choice is between a low resolution reconstruction using a few thick sections and a better resolution reconstruction using many thin sections, generally a tedious chore. This paper describes an approach to 3-D reconstruction which uses stereo images of serial thick sections to reconstruct an object including detail which changes within the depth of an individual thick section.


Author(s):  
Neil Rowlands ◽  
Jeff Price ◽  
Michael Kersker ◽  
Seichi Suzuki ◽  
Steve Young ◽  
...  

Three-dimensional (3D) microstructure visualization on the electron microscope requires that the sample be tilted to different positions to collect a series of projections. This tilting should be performed rapidly for on-line stereo viewing and precisely for off-line tomographic reconstruction. Usually a projection series is collected using mechanical stage tilt alone. The stereo pairs must be viewed off-line and the 60 to 120 tomographic projections must be aligned with fiduciary markers or digital correlation methods. The delay in viewing stereo pairs and the alignment problems in tomographic reconstruction could be eliminated or improved by tilting the beam if such tilt could be accomplished without image translation.A microscope capable of beam tilt with simultaneous image shift to eliminate tilt-induced translation has been investigated for 3D imaging of thick (1 μm) biologic specimens. By tilting the beam above and through the specimen and bringing it back below the specimen, a brightfield image with a projection angle corresponding to the beam tilt angle can be recorded (Fig. 1a).


Author(s):  
T. A. Dodson ◽  
E. Völkl ◽  
L. F. Allard ◽  
T. A. Nolan

The process of moving to a fully digital microscopy laboratory requires changes in instrumentation, computing hardware, computing software, data storage systems, and data networks, as well as in the operating procedures of each facility. Moving from analog to digital systems in the microscopy laboratory is similar to the instrumentation projects being undertaken in many scientific labs. A central problem of any of these projects is to create the best combination of hardware and software to effectively control the parameters of data collection and then to actually acquire data from the instrument. This problem is particularly acute for the microscopist who wishes to "digitize" the operation of a transmission or scanning electron microscope. Although the basic physics of each type of instrument and the type of data (images & spectra) generated by each are very similar, each manufacturer approaches automation differently. The communications interfaces vary as well as the command language used to control the instrument.


Molecules ◽  
2021 ◽  
Vol 26 (13) ◽  
pp. 3887
Author(s):  
Watcharapong Pudkon ◽  
Chavee Laomeephol ◽  
Siriporn Damrongsakkul ◽  
Sorada Kanokpanont ◽  
Juthamas Ratanavaraporn

Three-dimensional (3D) printing is regarded as a critical technology in material engineering for biomedical applications. From a previous report, silk fibroin (SF) has been used as a biomaterial for tissue engineering due to its biocompatibility, biodegradability, non-toxicity and robust mechanical properties which provide a potential as material for 3D-printing. In this study, SF-based hydrogels with different formulations and SF concentrations (1–3%wt) were prepared by natural gelation (SF/self-gelled), sodium tetradecyl sulfate-induced (SF/STS) and dimyristoyl glycerophosphorylglycerol-induced (SF/DMPG). From the results, 2%wt SF-based (2SF) hydrogels showed suitable properties for extrusion, such as storage modulus, shear-thinning behavior and degree of structure recovery. The 4-layer box structure of all 2SF-based hydrogel formulations could be printed without structural collapse. In addition, the mechanical stability of printed structures after three-step post-treatment was investigated. The printed structure of 2SF/STS and 2SF/DMPG hydrogels exhibited high stability with high degree of structure recovery as 70.4% and 53.7%, respectively, compared to 2SF/self-gelled construct as 38.9%. The 2SF/STS and 2SF/DMPG hydrogels showed a great potential to use as material for 3D-printing due to its rheological properties, printability and structure stability.


Atmosphere ◽  
2021 ◽  
Vol 12 (7) ◽  
pp. 906
Author(s):  
Ivan Bašták Ďurán ◽  
Martin Köhler ◽  
Astrid Eichhorn-Müller ◽  
Vera Maurer ◽  
Juerg Schmidli ◽  
...  

The single-column mode (SCM) of the ICON (ICOsahedral Nonhydrostatic) modeling framework is presented. The primary purpose of the ICON SCM is to use it as a tool for research, model evaluation and development. Thanks to the simplified geometry of the ICON SCM, various aspects of the ICON model, in particular the model physics, can be studied in a well-controlled environment. Additionally, the ICON SCM has a reduced computational cost and a low data storage demand. The ICON SCM can be utilized for idealized cases—several well-established cases are already included—or for semi-realistic cases based on analyses or model forecasts. As the case setup is defined by a single NetCDF file, new cases can be prepared easily by the modification of this file. We demonstrate the usage of the ICON SCM for different idealized cases such as shallow convection, stratocumulus clouds, and radiative transfer. Additionally, the ICON SCM is tested for a semi-realistic case together with an equivalent three-dimensional setup and the large eddy simulation mode of ICON. Such consistent comparisons across the hierarchy of ICON configurations are very helpful for model development. The ICON SCM will be implemented into the operational ICON model and will serve as an additional tool for advancing the development of the ICON model.


Author(s):  
So Young Joo ◽  
Seung Yeol Lee ◽  
Yoon Soo Cho ◽  
Sangho Yi ◽  
Cheong Hoon Seo

Abstract Hands are the part of the body that are most commonly involved in burns, and the main complications are finger joint contractures and nerve injuries. Hypertrophic scarring cannot be avoided despite early management of acute hand burn injuries, and some patients may need application of an exoskeleton robot to restore hand function. To do this, it is essential to individualize the customization of the robot for each patient. Three-dimensional (3D) technology, which is widely used in the field of implants, anatomical models, and tissue fabrication, makes this goal achievable. Therefore, this report is a study on the usefulness of an exoskeleton robot using 3D technology for patients who lost bilateral hand function due to burn injury. Our subject was a 45-year-old man with upper limb dysfunction of 560 days after a flame and chemical burn injury, with resultant impairment of manual physical abilities. After wearing an exoskeleton robot made using 3D printing technology, he could handle objects effectively and satisfactorily. This innovative approach provided considerable advantages in terms of customization of size and reduction in manufacturing time and costs, thereby showing great potential for use in patients with hand dysfunction after burn injury.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Mohammad Paymard ◽  
Marc W. Deyell ◽  
Santabhanu Chakrabarti ◽  
Zachary W. Laksman ◽  
Jacob Larsen ◽  
...  

Abstract Background This is a rare and challenging case of Wolff–Parkinson–White syndrome due to a posteroseptal accessory pathway located in the coronary sinus diverticulum. It is often difficult to precisely locate this type of accessory pathway, and the ablation procedure could be associated with collateral damage to the neighbouring coronary arteries. Case Presentation The patient was a 49-year-old female with Wolff–Parkinson–White syndrome who was referred for catheter ablation. She had had a previous unsuccessful attempt at ablation and had remained symptomatic despite drug therapy. The pre-procedural cardiac computed tomography scan revealed the presence of a diverticulum in the proximal coronary sinus. Using an advanced three-dimensional cardiac mapping system, the electroanatomic map of the diverticulum was created. The accessory pathway potential was identified within the diverticulum preceding the ventricular insertion. The accessory pathway was then successfully ablated using radiofrequency energy. Conclusion We have demonstrated that the advanced three-dimensional cardiac mapping system plays a very important role in guiding clinicians in order to precisely locate and safely ablate this type of challenging accessory pathway.


2020 ◽  
Vol 21 (15) ◽  
pp. 5499
Author(s):  
Hannah L. Smith ◽  
Stephen A. Beers ◽  
Juliet C. Gray ◽  
Janos M. Kanczler

Treatment for osteosarcoma (OS) has been largely unchanged for several decades, with typical therapies being a mixture of chemotherapy and surgery. Although therapeutic targets and products against cancer are being continually developed, only a limited number have proved therapeutically active in OS. Thus, the understanding of the OS microenvironment and its interactions are becoming more important in developing new therapies. Three-dimensional (3D) models are important tools in increasing our understanding of complex mechanisms and interactions, such as in OS. In this review, in vivo animal models, in vitro 3D models and in ovo chorioallantoic membrane (CAM) models, are evaluated and discussed as to their contribution in understanding the progressive nature of OS, and cancer research. We aim to provide insight and prospective future directions into the potential translation of 3D models in OS.