Control of jaw orientation and position in mastication and speech

1994 ◽  
Vol 71 (4) ◽  
pp. 1528-1545 ◽  
Author(s):  
D. J. Ostry ◽  
K. G. Munhall

1. The kinematics of sagittal-plane jaw motion were assessed in mastication and speech. The movement paths were described in joint coordinates, in terms of the component rotations and translations. The analysis focused on the relationship between rotation and horizontal translation. Evidence was presented that these can be separately controlled. 2. In speech, jaw movements were studied during consonant-vowel utterances produced at different rates and volumes. In mastication, bolus placement, compliance, and size as well as chewing rate were manipulated. Jaw movements were recorded using the University of Wisconsin X-ray microbeam system. Jaw rotation and translation were calculated on the basis of the motion of X-ray tracking pellets on the jaw. 3. The average magnitudes of jaw rotation and translation were greater in mastication than in speech. In addition, in speech, it was shown that the average rotation magnitude may vary independent of the horizontal translation magnitude. In mastication, the average magnitude of vertical jaw translation was not dependent on the magnitudes of jaw rotation or horizontal jaw translation. 4. The magnitude of rotation and horizontal jaw translation tended to be correlated when examined on a trial by trial basis. Some subjects also showed a correlation between jaw rotation and vertical jaw translation. However, the proportion of variance accounted for was greater for all subjects in the case of rotation and horizontal translation. 5. Joint space paths in both mastication and speech were found to be straight. The pattern was observed at normal and fast rates of speech and mastication and for loud speech as well. Straight line paths were also observed when subjects produced utterances that had both the syllabic structure and the intonation pattern of speech. The findings suggest that control may be organized in terms of an equilibrium jaw orientation and an equilibrium jaw position. 6. Departures from linearity were also observed. These were typically associated with differences during jaw closing in the end time of rotation and translation. Start time differences were not observed in jaw closing and the movement paths were typically linear within this region.

2021 ◽  
Author(s):  
Emily J. King ◽  
Natalie N. Viscariello ◽  
Larry A. DeWerd

This work seeks to develop standard X-ray beams that are matched to radiobiology X-ray irradiators. The calibration of detectors used for dose determination of these irradiators is performed with a set of standard X rays that are more heavily filtered and/or lower energy, which leads to a higher uncertainty in the dose measurement. Models of the XRad320, SARRP, and the X-ray tube at the University of Wisconsin Medical Radiation Research Center (UWMRRC) were created using the BEAMnrc user code of the EGSnrc Monte Carlo code system. These models were validated against measurements, and the resultant modeled spectra were used to determine the amount of added filtration needed to match the X-ray beams at the UWMRRC to those of the XRad320 and SARRP. The depth profiles and half-value layer (HVL) simulations performed using BEAMnrc agreed to measurements within 3% and 3.6%, respectively. A primary measurement device, a free-air chamber, was developed to measure air kerma in the medium energy range of X rays. The resultant spectra of the matched beams had HVL's that matched the HVL's of the radiobiology irradiators well within the 3% criteria recommended by the International Atomic Energy Agency (IAEA) and the average energies agreed within 2.4%. In conclusion, three standard X-ray beams were developed at the UWMRRC with spectra that more closely match the spectra of the XRad320 and SARRP radiobiology irradiators, which will aid in a more accurate dose determination during calibration of these irradiators.


1997 ◽  
Vol 40 (6) ◽  
pp. 1341-1351 ◽  
Author(s):  
David J. Ostry ◽  
Eric Vatikiotis-Bateson ◽  
Paul L. Gribble

The kinematics of human jaw movements were assessed in terms of the three orientation angles and three positions that characterize the motion of the jaw as a rigid body. The analysis focused on the identification of the jaw’s independent movement dimensions, and was based on an examination of jaw motion paths that were plotted in various combinations of linear and angular coordinate frames. Overall, both behaviors were characterized by independent motion in four degrees of freedom. In general, when jaw movements were plotted to show orientation in the sagittal plane as a function of horizontal position, relatively straight paths were observed. In speech, the slopes and intercepts of these paths varied depending on the phonetic material. The vertical position of the jaw was observed to shift up or down so as to displace the overall form of the sagittal plane motion path of the jaw. Yaw movements were small but independent of pitch, and vertical and horizontal position. In mastication, the slope and intercept of the relationship between pitch and horizontal position were affected by the type of food and its size. However, the range of variation was less than that observed in speech. When vertical jaw position was plotted as a function of horizontal position, the basic form of the path of the jaw was maintained but could be shifted vertically. In general, larger bolus diameters were associated with lower jaw positions throughout the movement. The timing of pitch and yaw motion differed. The most common pattern involved changes in pitch angle during jaw opening followed by a phase predominated by lateral motion (yaw). Thus, in both behaviors there was evidence of independent motion in pitch, yaw, horizontal position, and vertical position. This is consistent with the idea that motions in these degrees of freedom are independently controlled.


2000 ◽  
Vol 122 (03) ◽  
pp. 64-67 ◽  
Author(s):  
Leo O’Connor ◽  
Harry Hutchinson

This article reviews to enrich the variety of microelectromechanical systems (MEMS) to open new applications and markets. Established manufacturing methods for most MEMS were developed for electronics, and so the microcromachines turned out that way generally look like chips. The selection of materials is usually limited, and height, measured in microns, often remains in the single digits and rarely exceeds 20. Work at the University of Wisconsin in Madison is proceeding with a process that uses deep X-ray lithography. The technique is derived from an established micromanufacturing process known as LIGA, an acronym derived from the German terms for lithography, electroforming, and molding. LIGA, which has been around for a while, produces relatively tall micromachines by a method that radiates X-ray-sensitive materials to create molds. EFAB is being developed by USC’s Information Sciences Institute with funding from the Defense Advanced Research Projects Agency. To support commercialization of the process, the Institute has established the EFAB Consortium, which intends to give interested partners the option of acquiring prototype micro devices fabricated from their own 3D CAD designs.


2000 ◽  
Vol 83 (4) ◽  
pp. 2120-2137 ◽  
Author(s):  
Katsunari Hiraba ◽  
Kazuto Hibino ◽  
Kenji Hiranuma ◽  
Takefumi Negoro

Electromyographic (EMG) activities of the superior (SUP) and inferior heads (INF) of the lateral pterygoid muscle (LPT) were recorded in humans during voluntary stepwise changes in biting force and jaw position that were adopted to exclude the effects of acceleration and velocity of jaw movements on the muscle activity. The SUP behaved like a jaw-closing muscle and showed characteristic activity in relation to the biting force. It showed a considerable amount of background activity (5–32% of the maximum) even in the intercuspal position without teeth clenching and reached a nearly maximum activity at relatively lower biting-force levels than the jaw-closing muscles during increment of the biting force. Stretch reflexes were found in the SUP, the function of which could be to stabilize the condyle against the biting force that pulls the condyle posteriorly. This notion was verified by examining the biomechanics on the temporomandibular joint. The complex movements of the mandibular condyle in a sagittal plane were decomposed into displacement in the anteroposterior direction (Ac) and angle of rotation (RAc) around a kinesiological specific point on the condyle. In relation to Ac, each head of the LPT showed quite a similar behavior to each other in all types of jaw movements across all subjects. Working ranges of the muscle activities were almost constant (Ac <3 mm for the SUP and Ac >3 mm for the INF). The amount of EMG activity of the SUP changed in inverse proportion to Ac showing a hyperbola-like relation, whereas that of the INF changed rather linearly. The EMG amplitude of the SUP showed a quasilinear inverse relation with RAc in the hinge movement during which the condyle rotated with no movement in the anteroposterior direction. This finding suggests that the SUP controls the angular relationship between the articular disk and the condyle. On the other hand, the position of the disk in relation to the maxilla, not to the condyle, is controlled indirectly by the INF because the disk is attached to the condyle by tendinous ligaments.


Author(s):  
Hans Ris

The High Voltage Electron Microscope Laboratory at the University of Wisconsin has been in operation a little over one year. I would like to give a progress report about our experience with this new technique. The achievement of good resolution with thick specimens has been mainly exploited so far. A cold stage which will allow us to look at frozen specimens and a hydration stage are now being installed in our microscope. This will soon make it possible to study undehydrated specimens, a particularly exciting application of the high voltage microscope.Some of the problems studied at the Madison facility are: Structure of kinetoplast and flagella in trypanosomes (J. Paulin, U. of Georgia); growth cones of nerve fibers (R. Hannah, U. of Georgia Medical School); spiny dendrites in cerebellum of mouse (Scott and Guillery, Anatomy, U. of Wis.); spindle of baker's yeast (Joan Peterson, Madison) spindle of Haemanthus (A. Bajer, U. of Oregon, Eugene) chromosome structure (Hans Ris, U. of Wisconsin, Madison). Dr. Paulin and Dr. Hanna are reporting their work separately at this meeting and I shall therefore not discuss it here.


Author(s):  
S. Edith Taylor ◽  
Patrick Echlin ◽  
May McKoon ◽  
Thomas L. Hayes

Low temperature x-ray microanalysis (LTXM) of solid biological materials has been documented for Lemna minor L. root tips. This discussion will be limited to a demonstration of LTXM for measuring relative elemental distributions of P,S,Cl and K species within whole cells of tobacco leaves.Mature Wisconsin-38 tobacco was grown in the greenhouse at the University of California, Berkeley and picked daily from the mid-stalk position (leaf #9). The tissue was excised from the right of the mid rib and rapidly frozen in liquid nitrogen slush. It was then placed into an Amray biochamber and maintained at 103K. Fracture faces of the tissue were prepared and carbon-coated in the biochamber. The prepared sample was transferred from the biochamber to the Amray 1000A SEM equipped with a cold stage to maintain low temperatures at 103K. Analyses were performed using a tungsten source with accelerating voltages of 17.5 to 20 KV and beam currents from 1-2nA.


Author(s):  
K.K. Soni ◽  
D.B. Williams ◽  
J.M. Chabala ◽  
R. Levi-Setti ◽  
D.E. Newbury

In contrast to the inability of x-ray microanalysis to detect Li, secondary ion mass spectrometry (SIMS) generates a very strong Li+ signal. The latter’s potential was recently exploited by Williams et al. in the study of binary Al-Li alloys. The present study of Al-Li-Cu was done using the high resolution scanning ion microprobe (SIM) at the University of Chicago (UC). The UC SIM employs a 40 keV, ∼70 nm diameter Ga+ probe extracted from a liquid Ga source, which is scanned over areas smaller than 160×160 μm2 using a 512×512 raster. During this experiment, the sample was held at 2 × 10-8 torr.In the Al-Li-Cu system, two phases of major importance are T1 and T2, with nominal compositions of Al2LiCu and Al6Li3Cu respectively. In commercial alloys, T1 develops a plate-like structure with a thickness <∼2 nm and is therefore inaccessible to conventional microanalytical techniques. T2 is the equilibrium phase with apparent icosahedral symmetry and its presence is undesirable in industrial alloys.


Sign in / Sign up

Export Citation Format

Share Document