Preliminary Study Of the Behavior Of HPGe Detectors With Ion Implanted Contacts in the Ultralow-Energy X-Ray Region

1981 ◽  
Vol 25 ◽  
pp. 23-30 ◽  
Author(s):  
M. Slapa ◽  
J. Chwaszczewska ◽  
J. Jurkowski ◽  
A. Latussynski ◽  
G.C. Huth ◽  
...  

AbstractPreliminary study of performance of an HPGe detector with an ion implanted entrance window in the spectrometry of the ultralowenergy x-rays is presented.For the first time it has been shown that almost symmetric photopeaks and absence of low energy tailing can be obtained in this region from HPGe detectors.

1982 ◽  
pp. 23-30 ◽  
Author(s):  
M. Slapa ◽  
J. Chwaszczewska ◽  
J. Jurkowski ◽  
A. Latuszynski ◽  
G. C. Huth ◽  
...  

1979 ◽  
Vol 23 ◽  
pp. 249-256
Author(s):  
M. Singh ◽  
A.J. Dabrowski ◽  
G.C. Huth ◽  
J.S. Iwanczyk ◽  
B.C. Clark ◽  
...  

We have previously reported on the uniqueness and potential of room-temperature spectrometry of low-energy x-rays with a mercuric iodide (HgI2) detector (1,2,3). In this paper we emphasize the use of HgI2 detectors for x-ray fluorescence (XRF) analysis.Because no vacuum plumbing or cryogenic cooling is required, the design of a mercuric iodide room-temperature x-ray spectrometer is extremely simple. Our present design consists of coupling a detector directly to the first-stage FET in a modified Tennelec 161 D preamplifier and making the configuration “light-tight”. Aside from providing a suitable entrance window, there are no other requirements for routine spectroscopy.


2011 ◽  
Vol 26 (03n04) ◽  
pp. 601-603
Author(s):  
◽  
D. L. SIRGHI ◽  
M. BAZZI ◽  
G. BEER ◽  
L. BOMBELLI ◽  
...  

The SIDDHARTA experiment (SIlicon Drift Detector for Hadronic Atom Research by Timing Application) had the aim to perform kaonic atoms X-ray transitions measurements, to better understand aspects of the low-energy QCD in the strangeness sector. The experiment combined the excellent low-energy kaon beam generated at DAΦNE, allowing to use gaseous targets, with excellent fast X-rays detectors: Silicon Drift Detectors. SIDDHARTA was installed on DAΦNE in autumn 2008 and took data till late 2009. Apart of the kaonic hydrogen and kaonic deuterium measurements, we have performed the kaonic helium transitions to the 2p level ( L -lines) measurements: for the first time in a gaseous target for helium4 and for the first time ever for kaonic helium3. The interest for such type of measurement was rather high, being it triggered by two reasons: the so-called "kaonic helium puzzle" (even if this was solved by KEK-PS E570 experiment, but a cross-check was useful) and some theoretical predictions of possible high energy shift (at the level of 10 eV). In this paper the preliminary results for the measurements to the 2p level ( L -series) for kaonic helium4 and kaonic helium3 are presented.


2021 ◽  
Vol 9 (5) ◽  
pp. 175-180
Author(s):  
Deepali Modi

In this work a complex study of the capabilities Particle Induced X-Ray emission(PIXE) technique for the determination of minor constituents of aerosol samples has been done.The PIXE experiments were carried out at Cyclotron at Department of Physics, Panjab University Chandigarh using ~2.7MeV proton beam. The X-rays were detected with the help of low energy HPGE detector. Total fifteen samples were collected from various locations in Chandigarh.The minor elements identified in the aerosol samples wereS,Cl,K,Ca,Ti,Cr,Mn,Fe,Ni,Zn,V,Br and Pb. The data analysis was done using GUPIX software to extract the quantity of the trace elements.


1991 ◽  
Vol 69 (2) ◽  
pp. 90-101 ◽  
Author(s):  
Bakhshish Chand ◽  
Jatinder Goswamy ◽  
Devinder Mehta ◽  
Nirmal Singh ◽  
P. N. Trehan

The intensities of X rays and γ rays from the decays of 140Ba and 140La were measured precisely using Si(Li) and HPGe detectors. The L X-ray intensities in 140Ba decay are reported for the first time. The conversion electrons from these decays are investigated using a mini-orange electron spectrometer. The electron intensities for the (M + N.) conversion of 329, 487, 1596, and 1903 keV transitions in 140Ce were measured for the first time. From the present conversion-electron and γ-ray intensities, the conversion coefficients for various transitions in 140La and 140Ce were determined. Also, the γ–γ directional correlations for 15 cascades in,140Ce were studied using a HPGe–HPGe detector coincidence setup (time resolution = 7 ns). The 109–(329)– 487, 131–242, and 131–266 keV cascades in 140Ce were studied for the first time. The multipole mixing ratios for the 109, 131, 242, 266, 329, 432, 487, 751, 816, 868, 919, 925, and 951 keV transitions in 140Ce are deduced from the present directional correlation and conversion-coefficient measurements.


2021 ◽  
Vol 9 ◽  
Author(s):  
Julie Segal ◽  
Christopher Kenney ◽  
Jeffrey M. Kowalski ◽  
Jeffrey E. Kowalski ◽  
Gabriel Blaj ◽  
...  

New free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250 eV to 1.5 KeV. Achieving adequately shallow entrance windows is challenging because the high temperature anneal needed to activate the dopant also drives the dopant profile deeper, growing the region that is insensitive to soft x-rays. A new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high-resistivity silicon sensors. The microwave anneal technique can activate dopants at low substrate temperature, with minimal dopant diffusion, and can be used to fabricate both n-type and p-type entrance windows. SRP and SIMS measurements were used to verify dopant activation with negligible dopant diffusion. We then applied the microwave anneal process to a planar sensor wafer, using the new process to create the backside diode contact. Electrical test of the resulting sensors shows good reverse bias characteristics. The sensors have been bump-bonded to a read-out ASIC and used successfully to measure an Fe-55 x-ray spectrum. Process and device simulations were performed to characterize the quantum efficiency of the entrance window for soft x-rays. This technique is useful for other sensor applications requiring a shallow entrance window, including detectors for UV photons, low energy ions and low energy electrons.


Atmosphere ◽  
2019 ◽  
Vol 10 (4) ◽  
pp. 169 ◽  
Author(s):  
Mahbubur Rahman ◽  
Pasan Hettiarachchi ◽  
Vernon Cooray ◽  
Joseph Dwyer ◽  
Vladimir Rakov ◽  
...  

We present observations of X-rays from laboratory sparks created in the air at atmospheric pressure by applying an impulse voltage with long (250 µs) rise-time. X-ray production in 35 and 46 cm gaps for three different electrode configurations was studied. The results demonstrate, for the first time, the production of X-rays in gaps subjected to switching impulses. The low rate of rise of the voltage in switching impulses does not significantly reduce the production of X-rays. Additionally, the timing of the X-ray occurrence suggests the possibility that the mechanism of X-ray production by sparks is related to the collision of streamers of opposite polarity.


1996 ◽  
Vol 11 (5) ◽  
pp. 1169-1178 ◽  
Author(s):  
Kentaro Suzuya ◽  
Michihiro Furusaka ◽  
Noboru Watanabe ◽  
Makoto Osawa ◽  
Kiyohito Okamura ◽  
...  

Mesoscopic structures of SiC fibers produced from polycarbosilane by different methods were studied by diffraction and small-angle scattering of neutrons and x-rays. Microvoids of a size of 4–10 Å in diameter have been observed for the first time by neutron scattering in a medium momentum transfer range (Q = 0.1–1.0 Å−1). The size and the volume fraction of β–SiC particles were determined for fibers prepared at different heat-treatment temperatures. The results show that wide-angle neutron scattering measurements are especially useful for the study of the mesoscopic structure of multicomponent materials.


2006 ◽  
Vol 49 (spe) ◽  
pp. 17-23 ◽  
Author(s):  
Carlos de Austerlitz ◽  
Viviane Souza ◽  
Heldio Pereira Villar ◽  
Aloisio Cordilha

The performance of four X-ray qualities generated in a Pantak X-ray machine operating at 30-100 kV was determined with a parallel-plate ionization chamber and a Fricke dosimeter. X-ray qualities used were those recommended by Deutsch Internationale Normung DIN 6809 and dose measurements were carried out with Plexiglas® simulators. Results have shown that the Fricke dosimeter can be used not only for soft X-ray dosimetry, but also for the maintenance of low-energy measuring systems' calibration factor.