Software for XRF

1993 ◽  
Vol 37 ◽  
pp. 13-20
Author(s):  
Michael Mantler

As in other fields of spectroscopy, software for x-ray fluorescent analysis has to assist the user in instrument control, raw data refinement, qualitative interpretation of spectral data, and computations for obtaining quantitative results. From a historical point of view, instrument automation and data evaluation routines tor large numbers of samples have been a most important incentive for the introduction of computers into x-ray analysis.

1991 ◽  
Vol 35 (B) ◽  
pp. 987-993 ◽  
Author(s):  
M. Mantler ◽  
M. Schreiner ◽  
F. Weber ◽  
R. Ebner ◽  
F. Mairinger

AbstractAn x-ray spectrometer has been designed for pixel by pixel analysis along lines or across selected areas of paintings and other art-objects. Characteristic technical data are: 0.8mm2 pixel size, 800mm (vert.) by 1000mm (horiz.) by 200mm (perpendicularly to object) motion distances, ±20μm precision in positioning the system, 2x3m maximum object size (mounted vertically); 2.8kW x-ray tube; Si(Li)detector. PC's are used for instrument control and new, complex data evaluation software.


Author(s):  
J.M. Titchmarsh

The advances in recent years in the microanalytical capabilities of conventional TEM's fitted with probe forming lenses allow much more detailed investigations to be made of the microstructures of complex alloys, such as ferritic steels, than have been possible previously. In particular, the identification of individual precipitate particles with dimensions of a few tens of nanometers in alloys containing high densities of several chemically and crystallographically different precipitate types is feasible. The aim of the investigation described in this paper was to establish a method which allowed individual particle identification to be made in a few seconds so that large numbers of particles could be examined in a few hours.A Philips EM400 microscope, fitted with the scanning transmission (STEM) objective lens pole-pieces and an EDAX energy dispersive X-ray analyser, was used at 120 kV with a thermal W hairpin filament. The precipitates examined were extracted using a standard C replica technique from specimens of a 2¼Cr-lMo ferritic steel in a quenched and tempered condition.


Author(s):  
J.D. Shelburne ◽  
G.M. Roomans

Proper preparative procedures are a prerequisite for the validity of the results of x-ray microanalysis of biological tissue. Clinical applications of x-ray microanalysis are often concerned with diagnostic problems and the results may have profound practical significance for the patient. From this point of view it is especially important that specimen preparation for clinical applications is carried out correctly.Some clinical problems require very little tissue preparation. Hair, nails, and kidney and gallbladder stones may be examined and analyzed after carbon coating. High levels of zinc or copper in hair may be indicative of dermatological or systemic diseases. Nail clippings may be analyzed (as an alternative to the more conventional sweat test) to confirm a diagnosis of cystic fibrosis. X-ray microanalysis in combination with scanning electron microscopy has been shown to be the most reliable method for the identification of the components of kidney or gallbladder stones.A quantitatively very important clinical application of x-ray microanalysis is the identification and quantification of asbestos and other exogenous particles in lung.


2020 ◽  
Vol 71 (8) ◽  
pp. 21-26
Author(s):  
Elena-Emilia Oprescu ◽  
Cristina-Emanuela Enascuta ◽  
Elena Radu ◽  
Vasile Lavric

In this study, the SO42-/TiO2-La2O3-Fe2O3 catalyst was prepared and tested in the conversion of fructose to ethyl levulinate . The catalyst was characterized from the point of view of the textural analysis, FT-IR analysis, acid strength distribution, X-ray powder diffraction and pyridine adsorption IR spectra. The influence of the reaction parameters on the ethyl levulinate yield was study. The maximum yield of 37.95% in levulinate esters was obtained at 180 �C, 2 g catalyst and 4 h reaction time. The effect of ethyl levulinate addition to diesel-biodiesel blend in different rates, i.e, 0.5, 1, 2.5, 5 (w.t %) on density, kinematic viscosity and flash point was evaluated and compared with the European specification.


1985 ◽  
Vol 50 (10) ◽  
pp. 2139-2145
Author(s):  
Alexander Muck ◽  
Eva Šantavá ◽  
Bohumil Hájek

The infrared spectra and powder X-ray diffraction patterns of polycrystalline YPO4-YCrO4 samples are studied from the point of view of their crystal symmetry. Mixed crystals of the D4h19 symmetry are formed over the region of 0-30 mol.% YPO4 in YCrO4. The Td → D2d → D2 or C2v(GS eff) correlation is appropriate for both PO43- and CrO43- anions.


Coatings ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 570
Author(s):  
Olga Sánchez ◽  
Manuel Hernández-Vélez

ZnOTe compounds were grown by DC magnetron cosputtering from pure Tellurium (Te) and Zinc (Zn) cathodes in O2/Ar atmosphere. The applied power on the Zn target was constant equal to 100 W, while the one applied on the Te target took two values, i.e., 5 W and 10 W. Thus, two sample series were obtained in which the variable parameter was the distance from the Te targets to the substrate. Sample compositions were determined by Rutherford Backscattering Spectroscopy (RBS) experiments. Structural analysis was done using X-Ray diffraction (XRD) spectrometry and the growth of the hexagonal w-ZnO phase was identified in the XRD spectra. RBS results showed high bulk homogeneity of the samples forming ZnOTe alloys, with variable Te molar fraction (MF) ranging from 0.48–0.6% and from 1.9–3.1% for the sample series obtained at 5 W and 10 W, respectively. The results reflect great differences between the two sample series, particularly from the structural and optical point of view. These experiments point to the possibility of Te doping ZnO with the permanence of intrinsic defects, as well as the possibility of the formation of other Te solid phases when its content increases. The results and appreciable variations in the band gap transitions were detected from Photoluminescence (PL) measurements.


2020 ◽  
Author(s):  
O. V. Gorchakova ◽  
Yu. P. Kolmogorov ◽  
V. N. Gorchakov ◽  
G. A. Demchenko ◽  
S. N. Abdreshov

2019 ◽  
Vol 15 (S356) ◽  
pp. 96-96
Author(s):  
Eleonora Sani

AbstractI present a detailed study of ionized outflows in a large sample of 650 hard X-ray detected AGN. Taking advantage of the legacy value of the BAT AGN Spectroscopic Survey (BASS, DR1), we are able to reveal the faintest wings of the [OIII] emission lines associated with outflows. The sample allows us to derive the incidence of outflows covering a wide range of AGN bolometric luminosity and test how the outflow parameters are related with various AGN power tracers, such as black hole mass, Eddington ratio, luminosity. I’ll show how ionized outflows are more frequently found in type 1.9 and type 1 AGN (50% and 40%) with respect to the low fraction in type 2 AGN (20%). Within such a framework, I’ll demonstrate how type 2 AGN outflows are almost evenly balanced between blue- and red-shifted winds. This, in strong contrast with type 1 and type 1.9 AGN outflows which are almost exclusively blue-shifted. Finally, I’ll prove how the outflow occurrence is driven by the accretion rate, whereas the dependence of outflow properties with respect to the other AGN power tracers happens to be quite mild.


Materials ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 1986
Author(s):  
Andreas Koenig ◽  
Julius Schmidtke ◽  
Leonie Schmohl ◽  
Sibylle Schneider-Feyrer ◽  
Martin Rosentritt ◽  
...  

The performance of dental resin-based composites (RBCs) heavily depends on the characteristic properties of the individual filler fraction. As specific information regarding the properties of the filler fraction is often missing, the current study aims to characterize the filler fractions of several contemporary computer-aided design/computer-aided manufacturing (CAD/CAM) RBCs from a material science point of view. The filler fractions of seven commercially available CAD/CAM RBCs featuring different translucency variants were analysed using Scanning Electron Microscopy (SEM) with Energy Dispersive X-ray Spectroscopy (EDS), Micro-X-ray Computed Tomography (µXCT), Thermogravimetric Analysis (TG) and X-ray Diffractometry (XRD). All CAD/CAM RBCs investigated included midifill hybrid type filler fractions, and the size of the individual particles was clearly larger than the individual specifications of the manufacturer. The fillers in Shofu Block HC featured a sphericity of ≈0.8, while it was <0.7 in all other RBCs. All RBCs featured only X-ray amorphous phases. However, in Lava Ultimate, zircon crystals with low crystallinity were detected. In some CAD/CAM RBCs, inhomogeneities (X-ray opaque fillers or pores) with a size <80 µm were identified, but the effects were minor in relation to the total volume (<0.01 vol.%). The characteristic parameters of the filler fraction in RBCs are essential for the interpretation of the individual material’s mechanical and optical properties.


Sign in / Sign up

Export Citation Format

Share Document