scholarly journals Tests of Inclined Concrete-Filled Steel Tubular Stub Columns under Vertical Cyclic Loading

2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
Chayanon Hansapinyo ◽  
Chinnapat Buachart ◽  
Preeda Chaimahawan

This paper presents an experimental study on the cyclic behavior of fifteen concrete-filled steel tubular columns subjected to vertical cyclic loading. All test samples’ cross-sectional area is 75 × 75 mm2square, and they are 500 mm long. The main variables in the test are the thickness of the steel tube (1.8 and 3.0 mm with the width-to-thickness ratios (b/t) of 41.7 and 25), the strength of the infilled concrete (no-fill, 23 MPa, and 42 MPa), and the inclined angle (0, 4, and 9 degrees). The results show that all samples failed due to local buckling in compression followed by tearing of the steel tube in tension. The inclination angles of 4 and 9 degrees decreased the vertical compressive capacity of the 1.8 mm vertical hollowed steel column by 34 and 39 percent, respectively. However, the infilled concrete and thicker tube (3.0 mm) could substantially reduce the adverse effect of the inclination angle. The compressive ductility of the hollowed column with the thinner tube was significantly enhanced by the infilled concrete as well.

2017 ◽  
Vol 21 (9) ◽  
pp. 1273-1287 ◽  
Author(s):  
Jiepeng Liu ◽  
Yuanlong Yang ◽  
Hua Song ◽  
Yuyin Wang

A numerical analysis based on previous experiment has been carried out on T-shaped concrete-filled steel tubular columns subjected to constant axial compressive load and cyclic lateral loads. Tensile bar stiffeners were introduced to be welded on inside surfaces of steel tube to postpone its local buckling and to enhance the confinement of steel tube for concrete. A modified fiber-based method was developed to establish numerical modeling program of specimens’ cyclic behavior, incorporating the effect of stiffeners on postponing steel tube’s local buckling and the confinement for concrete. The reciprocating movement of inflection point along frame column is also considered in the numerical program. A simplified arc-length method was employed as iterative control algorithm of the numerical model. Horizontal load–displacement hysteretic curves of specimens were calculated with the numerical model and verified with test results. A restoring force model based on experimental investigation was proposed as simplified method for engineering practice.


2013 ◽  
Vol 639-640 ◽  
pp. 1077-1082
Author(s):  
Kai Lin Ju ◽  
Qiu Sheng Li ◽  
Guo Feng Du ◽  
Yi Li

Concrete-filled steel tube structure is one of the important load-bearing systems of modern high-rise building.The research indicate that concrete-filled steel tube structure has a good static and seismic performance,and concrete-filled steel tubular component is always used as axial compression and compression-bending component.However,what about the mechanical behavior of this combinational structure (concrete-filled steel tubular columns with steel bone built-in)? So there is a new type of special-shaped cross-section of composite structure,that is the T-shaped concrete-filled steel tubular columns with steel bone.The research about this structure is less throughout domestic and foreign.So the axial compressive experiments of six T-shaped concrete-filled steel tubular stub columns, five with and one without steel bone, were carried out. The effects of tube confining factor, bone indicator on the axial compressive behavior of the columns are analyzed. Experimental results indicate that the ultimate strength of the T-shaped steel tubular stub columns with steel bone increases, can be increased by 71.7%.And that the setting of steel bone improves the confinement of the concrete core, delays or even avoids the local buckling of the steel tube before the stress attains the yield strength. The ductility of the columns is also greatly increased.And at last in this paper, use of static equilibrium conditions and limit yield conditions,and in reference to literature[1],the calculation equation of compression capacity of this combinational column is derived.Moreover,calculation results according to the formula in this paper are in good agreement with the experimental results. The conclusions might be used as reference to structural design and plan.


Crystals ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 1434
Author(s):  
Muhammmad Faisal Javed ◽  
Haris Rafiq ◽  
Mohsin Ali Khan ◽  
Fahid Aslam ◽  
Muhammad Ali Musarat ◽  
...  

This experimental study presents concrete-filled double-skin tubular columns and demonstrates their expected advantages. These columns consist of an outer steel tube, an inner steel tube, and concrete sandwiched between two tubes. The influence of the outer-to-inner tube dimension ratio, outer tube to thickness ratio, and type of inner tube material (steel, PVC pipe) on the ultimate axial capacity of concrete-filled double-skin tubular columns is studied. It is found that the yield strength of the inner tube does not significantly affect the ultimate axial capacity of concrete-filled double-skin tubular composites. With the replacement of the inner tube of steel with a PVC pipe, on average, less than 10% strength is reduced, irrespective of size and dimensions of the steel tube. Hence, the cost of a project can be reduced by replacing inner steel tubes with a PVC pipes. Finally, the experimental results are compared with the existing design methods presented in AISC 360-16 (2016), GB51367 (2019), and EC4 (2004). It is found from the comparison that GB51367 (2019) gives better results, followed by AISC (2016) and EC4 (2004).


2020 ◽  
Vol 23 (10) ◽  
pp. 2204-2219
Author(s):  
Jun Wan ◽  
Jian Cai ◽  
Yue-Ling Long ◽  
Qing-Jun Chen

Based on the energy method, this article presents a theoretical study on the elastic local buckling of steel plates in rectangular concrete-filled steel tubular columns with binding bars subjected to eccentric compression. The formulas for elastic local buckling strength of the steel plates in eccentrically loaded rectangular concrete-filled steel tubular columns with binding bars are derived, assuming that the loaded edges are clamped and the unloaded edges of the steel plate are elastically restrained against rotation. Then, the experimental results are compared with these formulas, which exhibits good agreement. Subsequently, the formulas are used to study the elastic local buckling behavior of steel plates in rectangular concrete-filled steel tubular columns with binding bars under eccentric compression. It is found that the local buckling stress of steel plates in eccentrically loaded rectangular concrete-filled steel tubular columns with binding bars is significantly influenced by the stress gradient coefficient, width-to-thickness ratio, and the longitudinal spacing of binding bars. With the decrease of width–thickness ratios or the longitudinal spacing of binding bars or with the increase of the stress gradient coefficient, the local buckling stress increases. Furthermore, the influence of the longitudinal spacing of binding bar is more significant than the stress gradient coefficients. Finally, appropriate limitation for depth-to-thickness ratios ( D/ t), width-to-thickness ratios ( B/ t), and binding bar longitudinal spacing at various stress gradient coefficients ( α0) corresponding to different cross-sectional aspect ratios ( D/ B) are suggested for the design of rectangular concrete-filled steel tubular columns with binding bars under eccentric compression.


2021 ◽  

As a promising composite structure, gangue concrete filled steel tubular (GCFST) column exhibites favarable characteristics including high strength and economic efficiency. This paper conducted numerical investiagations on structural behavior of a ring-beam connection to GCFST column with concrete beam under cyclic loading. Furthermore, finite element models of column-beam connections were developed using ABAQUS and validated against full-scale experimental tests to identify accuracy of selected modeling approaches. Using these validated models, stress distribution of each component was examined to study the force-transferring mechanism among the components and failure modes of the ring-beam connection. Research study indicated that the ring-beam connection showed a reasonable force-transferring mechanism under cyclic loading and the remarkable earthquake-resistant performance with high capacity and acceptable ductility. Finally, parametric studies were performed to assess the influences of beam-to-column stiffness ratio,steel ratio, axial load level, and concrete compressive strength on connection cyclic behaviors. Parametric studies provided some suggestions and references for the application of the ring-beam connection in various engineering projects.


2020 ◽  
Vol 2020 ◽  
pp. 1-15
Author(s):  
Bing Zhang ◽  
Xia-Min Hu ◽  
Wei Wei ◽  
Qian-Biao Zhang ◽  
Ning-Yuan Zhang ◽  
...  

Hybrid FRP-concrete-steel double-skin tubular columns (hybrid DSTCs) are novel hollow columns consisting of an outer FRP tube, an inner steel tube, and the concrete between the two tubes. Hybrid DSTCs possess important advantages, such as excellent corrosion resistance as well as remarkable seismic resistance. However, existing studies are mainly focused on hybrid DSTCs with a circular cross section or a square cross section. When a column is subjected to different load levels in the two horizontal directions, a rectangular column is preferred as it can provide different bending stiffness and moment capacity around its two axes of symmetry. This paper presents an experimental study on rectangular DSTCs with a particular focus on the effect of the cross-sectional aspect ratio (i.e., the ratio of the breadth to the width of the rectangular cross section). The effect of the cross-sectional shape of the inner steel tube (i.e., both elliptical and rectangular inner steel tubes were used) and the effect of FRP tube thickness were also investigated experimentally. Experimental results show that a larger aspect ratio will have no negative effect on the confinement effect in rectangular DSTCs; a rectangular DSTC with a larger aspect ratio generally has a larger ultimate axial strain and a higher axial stress at the ultimate axial strain; rectangular DSTCs with an elliptical steel tube generally have better performance than corresponding specimens with a rectangular steel tube. An existing model, which was developed based on a model for rectangular FRP-confined concrete columns and a model for circular DSTCs, is verified using the test results of the present study. The model generally provides close predictions for the peak axial stress of the confined concrete but yields conservative predictions for the ultimate axial strain for rectangular DSTCs.


2013 ◽  
Vol 838-841 ◽  
pp. 439-443 ◽  
Author(s):  
Zhi Liang Zuo ◽  
Da Xin Liu ◽  
Jian Cai ◽  
Chun Yang ◽  
Qing Jun Chen

To improve the mechanical behavior of T-shaped concrete-filled steel tubular (T-CFT) column, the method that setting binding bars along the height of steel tube is proposed. Five T-CFT stub columns with binding bars and another two without binding bars subjected to axial compression were tested. The influences of the spacing and diameter of binding bars on the failure modes, maximum strength, and ductility of T-CFT stub columns are investigated. The experimental results demonstrate that by setting binding bars or decreasing the spacing of binding bars, the buckling modes of the steel plates are changed, the local buckling of the steel plates is postponed, and the confinement effects on the core concrete can be improved significantly. By setting binding bars, the bearing capacity and ductility of the columns are enhanced by 1.17 and 3.38 times at most, respectively. By increasing the diameter of binding bars, the ductility of the columns is improved, but the bearing capacity and buckling strength cannot be improved when the diameter is large enough.


2019 ◽  
Vol 23 (7) ◽  
pp. 1383-1396 ◽  
Author(s):  
Youwu Xu ◽  
Jian Yao ◽  
Xin Sun

Concrete-filled steel tubular columns are widely used in structural systems, and elliptical concrete-filled steel tubular columns are receiving more and more attention. An experimental study on cold-formed elliptical concrete-filled steel tubular stub columns was carried out under monotonic and cyclic axial compression. The failure modes, axial load–displacement curves, ultimate loads, hoop strain–axial strain behavior, strength deterioration, and residual deformation were obtained and discussed. Complementary finite element models considering the complex non-uniform confinement between steel tube and concrete were developed and validated by experimental results. Then, the validated FE model was used to study the influence of aspect ratio, yield strength of steel, and compressive strength of concrete on the axial capacity of elliptical concrete-filled steel tubular stub columns. Finally, a relatively simple superposition method was put forward to predict the axial bearing capacity of elliptical concrete-filled steel tubular stub columns. Compared with the test data, both the numerical method and superposition method can generate accurate predictions.


2011 ◽  
Vol 368-373 ◽  
pp. 511-514
Author(s):  
Wei Bin Yuan ◽  
Shi Long Ma

An investigation of the octagon-shaped concrete-filled double skin steel tubular columns which used PVC-U pipe to replace the steel tube as inner tube was carried out. In order to study the performances and mechanisms of the components when suffered axial load, ultimate axial bearing capacities of 9 components were tested. The cross-sectional size of the outer steel tube and inner PVC-U pipe and length of the specimen was concerned by the nominal steel ratio and the hollow ratio and slenderness ratio, respectively. The external steel tube and core concrete appeared three and four types of destruction phenomenons, respectively, but the inner PVC-U pipe did not destroy. Finally, experimental results and numerical analysis results were comparied.


Sign in / Sign up

Export Citation Format

Share Document