scholarly journals Test and Numerical Study on Monotonic Behavior of Complex CFT Column Joints

2019 ◽  
Vol 2019 ◽  
pp. 1-20
Author(s):  
Zeliang Yu ◽  
Bin Yang ◽  
Bin Jia ◽  
Yuhong Yan ◽  
Shaowen Xiao ◽  
...  

This paper presents a test and numerical investigation into the monotonic behavior of three different complex steel trusses to concrete-filled tubular (CFT) column joints. Based on an engineering structure, 1 : 4 reduced-scale specimens are manufactured and the three-dimensional subassembly testing system is designed to apply the monotonic load. Test phenomena and load-stress curves show that all three types of joints have a considerable load-carrying capacity and joint rigidity. Finite element (FE) analysis is adopted, and the stress distribution shows good agreement with test data. Both test and FE results show that local buckling and yielding in the root region of steel truss are the main failure modes of test joints and the core area of the CFT column remains intact which are in accordance with the design conception of “strong column and weak beam.” Design conception of proposed overlap joint form is then investigated based on the FE model, and results show that the optimized overlap joint can effectively reduce the stress concentration in the adjacent steel tube and beam member when compared to the traditional N-type overlap joint. Finally, the influence of the outer diaphragm on the stiffness of joint is analyzed. By comparing the end-displacement of the beam member, conclusion can be obtained that the beam flange thickness is suggested to be chosen as the outer diaphragm thickness. The forms of three different proposed joints and their design conceptions can provide good guidance for designers and engineers.

2013 ◽  
Vol 838-841 ◽  
pp. 439-443 ◽  
Author(s):  
Zhi Liang Zuo ◽  
Da Xin Liu ◽  
Jian Cai ◽  
Chun Yang ◽  
Qing Jun Chen

To improve the mechanical behavior of T-shaped concrete-filled steel tubular (T-CFT) column, the method that setting binding bars along the height of steel tube is proposed. Five T-CFT stub columns with binding bars and another two without binding bars subjected to axial compression were tested. The influences of the spacing and diameter of binding bars on the failure modes, maximum strength, and ductility of T-CFT stub columns are investigated. The experimental results demonstrate that by setting binding bars or decreasing the spacing of binding bars, the buckling modes of the steel plates are changed, the local buckling of the steel plates is postponed, and the confinement effects on the core concrete can be improved significantly. By setting binding bars, the bearing capacity and ductility of the columns are enhanced by 1.17 and 3.38 times at most, respectively. By increasing the diameter of binding bars, the ductility of the columns is improved, but the bearing capacity and buckling strength cannot be improved when the diameter is large enough.


2021 ◽  
pp. 136943322110015
Author(s):  
Rana Al-Dujele ◽  
Katherine Ann Cashell

This paper is concerned with the behaviour of concrete-filled tubular flange girders (CFTFGs) under the combination of bending and tensile axial force. CFTFG is a relatively new structural solution comprising a steel beam in which the compression flange plate is replaced with a concrete-filled hollow section to create an efficient and effective load-carrying solution. These members have very high torsional stiffness and lateral torsional buckling strength in comparison with conventional steel I-girders of similar depth, width and steel weight and are there-fore capable of carrying very heavy loads over long spans. Current design codes do not explicitly include guidance for the design of these members, which are asymmetric in nature under the combined effects of tension and bending. The current paper presents a numerical study into the behaviour of CFTFGs under the combined effects of positive bending and axial tension. The study includes different loading combinations and the associated failure modes are identified and discussed. To facilitate this study, a finite element (FE) model is developed using the ABAQUS software which is capable of capturing both the geometric and material nonlinearities of the behaviour. Based on the results of finite element analysis, the moment–axial force interaction relationship is presented and a simplified equation is proposed for the design of CFTFGs under combined bending and tensile axial force.


2019 ◽  
Vol 2019 ◽  
pp. 1-14
Author(s):  
He Zhang ◽  
Kai Wu ◽  
Chao Xu ◽  
Lijian Ren ◽  
Feng Chen

Two columns of thin-walled concrete-filled steel tubes (CFSTs), in which tube seams are connected by self-tapping screws, are axial compression tested and FEM simulated; the influence of local buckling on the column compression bearing capacity is discussed. Failure modes of square thin-wall CFST columns are, first, steel tube plate buckling and then the collapse of steel and concrete in some corner edge areas. Interaction between concrete and steel makes the column continue to withstand higher forces after buckling appears. A large deflection analysis for tube elastic buckling reflects that equivalent uniform stress of the steel plate in the buckling area can reach yield stress and that steel can supply enough designing stress. Aiming at failure modes of square thin-walled CFST columns, a B-type section is proposed as an improvement scheme. Comparing the analysis results, the B-type section can address both the problems of corner collapse and steel plate buckling. This new type section can better make full use of the stress of the concrete material and the steel material; this type section can also increase the compression bearing capacity of the column.


Materials ◽  
2019 ◽  
Vol 12 (17) ◽  
pp. 2716 ◽  
Author(s):  
Shiming Liu ◽  
Xinxin Ding ◽  
Xiaoke Li ◽  
Yongjian Liu ◽  
Shunbo Zhao

This paper studies the effect of high-strength steel fiber reinforced concrete (SFRC) on the axial compression behavior of rectangular-sectional SFRC-filled steel tube columns. The purpose is to improve the integrated bearing capacity of these composite columns. Nine rectangular-sectional SFRC-filled steel tube columns and one normal concrete-filled steel tube column were designed and tested under axial loading to failure. The compressive strength of concrete, the volume fraction of steel fiber, the type of internal longitudinal stiffener and the spacing of circular holes in perfobond rib were considered as the main parameters. The failure modes, axial load-deformation curves, energy dissipation capacity, axial bearing capacity, and ductility index are presented. The results identified that steel fiber delayed the local buckling of steel tube and increased the ductility and energy dissipation capacity of the columns when the volume fraction of steel fiber was not less than 0.8%. The longitudinal internal stiffening ribs and their type changed the failure modes of the local buckling of steel tube, and perfobond ribs increased the ductility and energy dissipation capacity to some degree. The compressive strength of SFRC failed to change the failure modes, but had a significant impact on the energy dissipation capacity, bearing capacity, and ductility. The predictive formulas for the bearing capacity and ductility index of rectangular-sectional SFRC-filled steel tube columns are proposed to be used in engineering practice.


Author(s):  
Erik Levold ◽  
Andrea Restelli ◽  
Lorenzo Marchionni ◽  
Caterina Molinari ◽  
Luigino Vitali

Considering the future development for offshore pipelines, moving towards difficult operating condition and deep/ultra-deep water applications, there is the need to understand the failure mechanisms and better quantify the strength and deformation capacity of corroded pipelines considering the relevant failure modes (collapse, local buckling under internal and external pressure, fracture / plastic collapse etc.). A Joint Industry Project sponsored by ENI E&P and Statoil has been launched with the objective to quantify and assess the strength and deformation capacity of corroded pipes in presence of internal overpressure and axial/bending loading. In this paper: • The State-of-the-Art on strength and deformation capacity of corroded pipes is presented; • The full-scale laboratory tests on corroded pipes under bending moment dominated load conditions, performed at C-FER facilities, are shown together with the calibrated ABAQUS FE Model; • The results of the ABAQUS FEM parametric study are presented.


2013 ◽  
Vol 859 ◽  
pp. 105-108
Author(s):  
Xiong Zhao ◽  
Xu Kuan Li ◽  
Qing Xin Ren ◽  
Tai Cheng ◽  
Xiao Lian Long

This paper reports a finite element analysis of the flexural behaviour of concrete-filled steel tubular members with elliptical section. A set of test data were used to verify the FE modeling. generally, good agreement was achieved. Typical curves of moment (M) versus deflection at mid-span (um), as well as stress distributions of steel tube and concrete of the composite members were compared and discussed. The results clearly show that the FE model is available for predicting the load-bearing capacities and the failure modes of the specimens.


2011 ◽  
Vol 94-96 ◽  
pp. 583-586
Author(s):  
Bao Feng Fan ◽  
Na Yang ◽  
Qing Shan Yang ◽  
Leroy Gardner

The mechanical behaviors of intersecting joints considering damage accumulation in steel tube structures is analyzed through the FE-program ABAQUS. The stress characteristic and failure modes of these joints are concluded. Especially, it has been analyzed influence of the change of geometric parameters to mechanical behavior of joints. Finally, the results indicate the joints have a good mechanical performance and good plastic deformation as to excessive local buckling of chord under the loads.


2013 ◽  
Vol 19 (2) ◽  
pp. 184-195 ◽  
Author(s):  
M. C. Sundarraja ◽  
G. Ganesh Prabhu

This research is aimed at investigating the structural improvements of concrete filled steel tubular (CFST) sections with normal strength concrete externally bonded with fibre reinforced polymer (FRP) composites. For this study, compact mild steel tubes were used with the main variable being FRP characteristics. Carbon fibre reinforced polymer (CFRP) fabrics was used as horizontal strips (lateral ties) with several other parameters such as the number of layers and spacing of strips. Among twenty one columns, eighteen were externally bonded by CFRP strips having a constant width of 50 mm with a spacing of 20 mm and 40 mm and the remaining three columns were unbounded. Experiments were undertaken until column failure to fully understand the influence of FRP characteristics on the compressive behaviour of square CFST sections including their failure modes, axial stress-strain behaviour, and enhancement in load carrying capapcity. It was found that the external bonding of CFRP strips provides external confinement pressure effectively and intended to delay the local buckling of steel tube and also to improve the load carrying capacity further.


2019 ◽  
Vol 23 (7) ◽  
pp. 1383-1396 ◽  
Author(s):  
Youwu Xu ◽  
Jian Yao ◽  
Xin Sun

Concrete-filled steel tubular columns are widely used in structural systems, and elliptical concrete-filled steel tubular columns are receiving more and more attention. An experimental study on cold-formed elliptical concrete-filled steel tubular stub columns was carried out under monotonic and cyclic axial compression. The failure modes, axial load–displacement curves, ultimate loads, hoop strain–axial strain behavior, strength deterioration, and residual deformation were obtained and discussed. Complementary finite element models considering the complex non-uniform confinement between steel tube and concrete were developed and validated by experimental results. Then, the validated FE model was used to study the influence of aspect ratio, yield strength of steel, and compressive strength of concrete on the axial capacity of elliptical concrete-filled steel tubular stub columns. Finally, a relatively simple superposition method was put forward to predict the axial bearing capacity of elliptical concrete-filled steel tubular stub columns. Compared with the test data, both the numerical method and superposition method can generate accurate predictions.


2011 ◽  
Vol 287-290 ◽  
pp. 1037-1042 ◽  
Author(s):  
Jun Guang Zhang ◽  
Yong Jian Liu ◽  
Jian Yang ◽  
Kai Lei Xu

For further study of mechanical properties of concrete-filled steel box columns (CFSBCs) with longitudinal stiffeners, axially loading tests of CFSBCs with longitudinal stiffeners was conducted to obtain their ultimate bearing capacity and failure modes. The test results were compared with those of hollow steel box columns with longitudinal stiffeners. Cross section of the test specimen was scaled from a chord member of Dongjiang Bridge. The experimental results show that failure mode of CFSBCs with longitudinal stiffeners is local buckling of steel plates, which is different from that of concrete-filled thin wall steel tube columns with longitudinal stiffeners. Although longitudinal stiffeners can prevent global buckling of steel plates, the effect is less obvious than that of concrete-filled thin wall steel tube columns. Meanwhile, three-dimensional finite element models (FEM) of the specimens were modeled using computer program ANSYS to obtain bearing capacities and load-strain curves. The FEM results coincide quite well with the test results. Further, influence of width to thickness ratio on mechanical behavior of CFSBCs was analyzed using FEM.


Sign in / Sign up

Export Citation Format

Share Document