scholarly journals An Optical Flow-Based Approach for Minimally Divergent Velocimetry Data Interpolation

2019 ◽  
Vol 2019 ◽  
pp. 1-14
Author(s):  
Berkay Kanberoglu ◽  
Dhritiman Das ◽  
Priya Nair ◽  
Pavan Turaga ◽  
David Frakes

Three-dimensional (3D) biomedical image sets are often acquired with in-plane pixel spacings that are far less than the out-of-plane spacings between images. The resultant anisotropy, which can be detrimental in many applications, can be decreased using image interpolation. Optical flow and/or other registration-based interpolators have proven useful in such interpolation roles in the past. When acquired images are comprised of signals that describe the flow velocity of fluids, additional information is available to guide the interpolation process. In this paper, we present an optical-flow based framework for image interpolation that also minimizes resultant divergence in the interpolated data.

Author(s):  
Jerome J. Paulin

Within the past decade it has become apparent that HVEM offers the biologist a means to explore the three-dimensional structure of cells and/or organelles. Stereo-imaging of thick sections (e.g. 0.25-10 μm) not only reveals anatomical features of cellular components, but also reduces errors of interpretation associated with overlap of structures seen in thick sections. Concomitant with stereo-imaging techniques conventional serial Sectioning methods developed with thin sections have been adopted to serial thick sections (≥ 0.25 μm). Three-dimensional reconstructions of the chondriome of several species of trypanosomatid flagellates have been made from tracings of mitochondrial profiles on cellulose acetate sheets. The sheets are flooded with acetone, gluing them together, and the model sawed from the composite and redrawn.The extensive mitochondrial reticulum can be seen in consecutive thick sections of (0.25 μm thick) Crithidia fasciculata (Figs. 1-2). Profiles of the mitochondrion are distinguishable from the anterior apex of the cell (small arrow, Fig. 1) to the posterior pole (small arrow, Fig. 2).


Author(s):  
H Geramizadeh ◽  
S Dariushi ◽  
S Jedari Salami

The current study focuses on designing the optimal three-dimensional printed sandwich structures. The main goal is to improve the energy absorption capacity of the out-of-plane honeycomb sandwich beam. The novel Beta VI and Alpha VI were designed in order to achieve this aim. In the Beta VI, the connecting curves (splines) were used instead of the four diagonal walls, while the two vertical walls remained unchanged. The Alpha VI is a step forward on the Beta VI, which was promoted by filleting all angles among the vertical walls, created arcs, and face sheets. The two offered sandwich structures have not hitherto been provided in the literature. All models were designed and simulated by the CATIA and ABAQUS, respectively. The three-dimensional printer fabricated the samples by fused deposition modeling technique. The material properties were determined under tensile, compression, and three-point bending tests. The results are carried out by two methods based on experimental tests and finite element analyses that confirmed each other. The achievements provide novel insights into the determination of the adequate number of unit cells and demonstrate the energy absorption capacity of the Beta VI and Alpha VI are 23.7% and 53.9%, respectively, higher than the out-of-plane honeycomb sandwich structures.


2020 ◽  
Vol 53 (03) ◽  
pp. 324-334
Author(s):  
Gautam Biswas

Abstract Reconstruction of the complex anatomy and aesthetics of the midface is often a challenge. A careful understanding of this three-dimensional (3D) structure is necessary. Anticipating the extent of excision and its planning following oncological resections is critical.In the past over two decades, with the advances in microsurgical procedures, contributions toward the reconstruction of this area have generated interest. Planning using digital imaging, 3D printed models, osseointegrated implants, and low-profile plates, has favorably impacted the outcome. However, there are still controversies in the management: to use single composite tissues versus multiple tissues; implants versus autografts; vascularized versus nonvascularized bone; prosthesis versus reconstruction.This article explores the present available options in maxillary reconstruction and outlines the approach in the management garnered from past publications and experiences.


2021 ◽  
Vol 11 (11) ◽  
pp. 4981
Author(s):  
Andreas Tausendfreund ◽  
Dirk Stöbener ◽  
Andreas Fischer

In the concept of the process signature, the relationship between a material load and the modification remaining in the workpiece is used to better understand and optimize manufacturing processes. The basic prerequisite for this is to be able to measure the loads occurring during the machining process in the form of mechanical deformations. Speckle photography is suitable for this in-process measurement task and is already used in a variety of ways for in-plane deformation measurements. The shortcoming of this fast and robust measurement technique based on image correlation techniques is that out-of-plane deformations in the direction of the measurement system cannot be detected and increases the measurement error of in-plane deformations. In this paper, we investigate a method that infers local out-of-plane motions of the workpiece surface from the decorrelation of speckle patterns and is thus able to reconstruct three-dimensional deformation fields. The implementation of the evaluation method enables a fast reconstruction of 3D deformation fields, so that the in-process capability remains given. First measurements in a deep rolling process show that dynamic deformations underneath the die can be captured and demonstrate the suitability of the speckle method for manufacturing process analysis.


2021 ◽  
Vol 14 (4) ◽  
pp. 1-20
Author(s):  
Dzemila Sero ◽  
Isabelle Garachon ◽  
Erma Hermens ◽  
Robert Van Liere ◽  
Kees Joost Batenburg

Fingerprints play a central role in any field where person identification is required. In forensics and biometrics, three-dimensional fingerprint-based imaging technologies, and corresponding recognition methods, have been vastly investigated. In cultural heritage, preliminary studies provide evidence that the three-dimensional impressions left on objects from the past (ancient fingerprints) are of paramount relevance to understand the socio-cultural systems of former societies, to possibly identify a single producer of multiple potteries, and to authenticate the artist of a sculpture. These findings suggest that the study of ancient fingerprints can be further investigated and open new avenues of research. However, the potential for capturing and analyzing ancient fingerprints is still largely unexplored in the context of cultural heritage research. In fact, most of the existing studies have focused on plane fingerprint representations and commercial software for image processing. Our aim is to outline the opportunities and challenges of digital fingerprint recognition in answering a range of questions in cultural heritage research. Therefore, we summarize the fingerprint-based imaging technologies, reconstruction methods, and analyses used in biometrics that could be beneficial to the study of ancient fingerprints in cultural heritage. In addition, we analyze the works conducted on ancient fingerprints from potteries and ceramic/fired clay sculptures. We conclude with a discussion on the open challenges and future works that could initiate novel strategies for ancient fingerprint acquisition, digitization, and processing within the cultural heritage community.


Author(s):  
Joseph M. Iaquinto ◽  
Richard Tsai ◽  
Michael J. Fassbind ◽  
David R. Haynor ◽  
Bruce J. Sangeorzan ◽  
...  

The ability to accurately measure three dimensional (3D) bone kinematics is key to understanding the motion of the joints of the body, and how such motion is altered by injury, disease, and treatment. Precise measurement of such kinematics is technically challenging. Biplane fluoroscopy is ideally suited to measure bone motion. Such systems have been developed in the past for both radiographic stereo-photogrammetric analysis (RSA) [1] and the more challenging model-based analysis [2]. Research groups have studied the knee [3,4], shoulder [5] and ankle [6] motion with similar techniques. The work presented here is an initial evaluation of the performance of our system, i.e., a validation that this in-house system can detect magnitudes of motion on-par with other existing systems.


2005 ◽  
Vol 127 (2) ◽  
pp. 271-276 ◽  
Author(s):  
D. N. Dilley ◽  
D. A. Stephenson ◽  
P. V. Bayly ◽  
A. J. Schaut

Drill chatter degrades hole roundness, hole size, and tool life. This wastes time and money in tools, scrap, and hole rework. Chatter prediction in milling and turning has shown significant benefit to industry; however, researchers have been unable to accurately predict chatter in drilling applications. In the past, the drill, including the chisel edge, was modeled as either a fixed-fixed or fixed-pinned beam (Tekinalp, O., and Ulsoy, A. G., 1989, “Modeling and Finite Element Analysis of Drill Bit Vibrations,” ASME J. Eng. Indust. 111, pp. 148–154), but more recent research (Dilley, D. N., Bayly, P. V., and Schaut, A. J., 2005, “Effects of the Chisel Edge on the Chatter Frequency in Drilling,” J. Sound Vib., 281, pp. 423–428) has shown that a fixed-embedded model using springs improves frequency matching. The effects of the drill margins on dynamics have not been studied. The fixed-fixed or fixed-pinned model will be shown to be inappropriate for modeling the effects of margin engagement, while the spring-end boundary condition can better approximate the frequency increase observed experimentally as the drill margins engage deeper into the hole. In addition, the shifted frequency is well below the frequency found from an analytical fixed-fixed or fixed-pinned beam. Evidence that the margins cause the frequency shift is seen in three-dimensional waterfall plots that show this shift for pilot hole drilling (in which the margins are engaged), but not for tube drilling (in which margins are not engaged).


2016 ◽  
Vol 83 (4) ◽  
Author(s):  
Youlong Chen ◽  
Yong Zhu ◽  
Xi Chen ◽  
Yilun Liu

In this work, the compressive buckling of a nanowire partially bonded to an elastomeric substrate is studied via finite-element method (FEM) simulations and experiments. The buckling profile of the nanowire can be divided into three regimes, i.e., the in-plane buckling, the disordered buckling in the out-of-plane direction, and the helical buckling, depending on the constraint density between the nanowire and the substrate. The selection of the buckling mode depends on the ratio d/h, where d is the distance between adjacent constraint points and h is the helical buckling spacing of a perfectly bonded nanowire. For d/h > 0.5, buckling is in-plane with wavelength λ = 2d. For 0.27 < d/h < 0.5, buckling is disordered with irregular out-of-plane displacement. While, for d/h < 0.27, buckling is helical and the buckling spacing gradually approaches to the theoretical value of a perfectly bonded nanowire. Generally, the in-plane buckling induces smaller strain in the nanowire, but consumes the largest space. Whereas the helical mode induces moderate strain in the nanowire, but takes the smallest space. The study may shed useful insights on the design and optimization of high-performance stretchable electronics and three-dimensional complex nanostructures.


Sign in / Sign up

Export Citation Format

Share Document