scholarly journals Sensitive Quantification of Liensinine Alkaloid Using a HPLC-MS/MS Method and Its Application in Microvolume Rat Plasma

2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Fen Wei ◽  
Xilan Gou ◽  
Xiao Xu ◽  
Sicen Wang ◽  
Tao Bao

Liensinine, an important alkaloid in lotus seed, exhibits multiple functions such as anti-AIDS, anticancer, antidepressant, and antihypertensive properties. In this study, a highly sensitive HPLC-MS/MS method was developed and validated for the quantification of liensinine in microvolume rat plasma as low as 45 μL. Chromatographic separation was carried out using a reverse-phase Gemini-C18 column (100 mm × 3 mm i.d. × 5 μm), and mass selective detection using multiple reaction monitoring was attained using an electrospray ionization source, which operated in the positive mode. Dauricine was used as the internal standard. The precursor-to-product ion transition m/z 611.15 > 206.10 was selected for the detection of liensinine; m/z 625.25 > 206.10 was used for the detection of dauricine. The developed method is linear over the concentration range of 0.05–1000 ng/mL with an excellent coefficient of determination (R2 = 0.991). The recoveries ranged from 92.57% to 95.88% at three quality control levels. Intraday and interday precision and accuracy are less than 12.2% and 6.59%, respectively. The lower limit of quantification (LLOQ) is 0.05 ng/mL. The matrix effect was insignificant and acceptable. The validated method was successfully applied to the pharmacokinetic study of liensinine in rats. This method can be used for in vivo studies as well as quality control of traditional Chinese medicines and herbal tea containing liensinine alkaloid.

Molecules ◽  
2019 ◽  
Vol 24 (21) ◽  
pp. 3953 ◽  
Author(s):  
Zhao ◽  
Tan ◽  
Chen ◽  
Sun ◽  
Wang ◽  
...  

As a novel monoterpenoid indole alkaloid, gardneramine has been confirmed to possess excellent nervous depressive effects. However, there have been no reports about the measurement of gardneramine in vitro and in vivo. The motivation of this study was to establish and validate a specific, sensitive, and robust analytical method based on UHPLC-MS/MS for quantification of gardneramine in rat plasma and various tissues after intravenous administration. The analyte was extracted from plasma and tissue samples by protein precipitation with methanol using theophylline as an internal standard (I.S.). The analytes were separated on an Agilent ZORBAX Eclipse Plus C18 column using a gradient elution of acetonitrile and 0.1% formic acid in water at a flow rate of 0.3 mL/min. Gardneramine and I.S. were detected and quantified using positive electrospray ionization in multiple reaction monitoring (MRM) mode with transitions of m/z 413.1→217.9 for gardneramine and m/z 181.2→124.1 for I.S.. Perfect linearity range was 1–2000 ng/mL with a correlation coefficient (r2) of ≥0.990. The lower limit of quantification (LLOQ) of 1.0 ng/mL was adequate for application to different preclinical studies. The method was successfully applied for determination of gardneramine in bio-samples.


Molecules ◽  
2020 ◽  
Vol 25 (13) ◽  
pp. 2964
Author(s):  
Siman Ma ◽  
Jia Lun ◽  
Yanru Liu ◽  
Zhen Jiang ◽  
Xingjie Guo

In this study, a specific and sensitive method of liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed for the determination of penconazole enantiomers in rat plasma. The enantioseparation was achieved on a Chiralpak IC column by using acetonitrile/water (80:20, v/v) as the mobile phase. Penconazole enantiomers and internal standard l-lansoprazole (IS) were detected in multiple reaction monitoring (MRM) mode with positive electrospray ionization source. The method was validated over the concentration range of 2.5–250.0 ng mL−1 for penconazole enantiomers. Good linearity was obtained for both enantiomers with correlation coefficients (R) greater than 0.995. The relative error was well within the admissible range of −1.1–3.2%, and relative standard deviation was less than 6.0%. After validation, the established method was successfully applied to a stereoselective toxicokinetic study in female and male rats after oral administration of 50 mg kg−1 racemic penconazole. This is the first experiment regarding the stereospecific toxicokinetic study of penconazole and the bioanalytical approach for its quantitation in vivo.


Author(s):  
Yonghui Shen ◽  
Deru Meng ◽  
Feifei Chen ◽  
Hui Jiang ◽  
Liming Hu ◽  
...  

AbstractSarecycline is a narrow-spectrum antibiotic for the treatment of acne, which is a chronic inflammatory disease of the hair follicle sebaceous glands. In the study, UPLC-MS/MS was used to establish a rapid and accurate analytical method. The sarecycline was determined with poziotinib as internal standard (IS) in rat plasma. An ACQUITY UPLC HSS T3 column (2.1 × 100 mm, 1.8 μm) could performe chromatographic separation with the mobile phase (methanol: water of 0.1% formic acid) with gradient elution. The ions of target fragment were m/z 488.19→410.14 for sarecycline and m/z 492.06→354.55 for poziotinib, which could quantify the electrospray ionization of positive multiple reaction monitoring (MRM) mode. The linear calibration curve of the concentration range was 1–1,000 ng/mL for sarecycline with a lower limit of quantification (LLOQ) of 1 ng/mL. The mean recovery was between 82.46 and 95.85% for sarecycline and poziotinib in rat plasma. RSD for precision of inter-day and intra-day were between 3.24 and 13.36%, and the accuracy ranged from 105.26 to 109.75%. The developed and validated method was perfectly used in the pharmacokinetic study and bioavailability of sarecycline after intravenous and oral administration in rats.


Molecules ◽  
2020 ◽  
Vol 25 (9) ◽  
pp. 2039
Author(s):  
Na Yoon Kim ◽  
Yong-Chul Kim ◽  
Yoon Gyoon Kim

This study aimed to develop and validate a sensitive liquid chromatography-coupled tandem mass spectrometry method for the quantification of LDD-2614, an indirubin derivative and novel FLT3 inhibitor, in rat plasma. In addition, the developed analytical method was applied to observe the pharmacokinetic properties of LDD-2614. Chromatographic separation was achieved on a Luna omega C18 column using a mixture of water and acetonitrile, both containing 0.1% formic acid. Quantitation was performed using positive electrospray ionization in a multiple reaction monitoring (MRM) mode. The MRM transitions were optimized as m/z 426.2→113.1 for LDD-2614 and m/z 390.2→113.1 for LDD-2633 (internal standard), and the lower limit of quantification (LLOQ) for LDD-2614 was determined as 0.1 ng/mL. Including the LLOQ, the nine-point calibration curve was linear with a correlation coefficient greater than 0.9991. Inter- and intraday accuracies (RE) ranged from −3.19% to 8.72%, and the precision was within 9.02%. All validation results (accuracy, precision, matrix effect, recovery, stability, and dilution integrity) met the acceptance criteria of the U.S. Food and Drug Administration and the Korea Ministry of Food and Drug Safety guidelines. The proposed method was validated and demonstrated to be suitable for the quantification of LDD-2614 for pharmacokinetics studies.


2019 ◽  
Vol 2019 ◽  
pp. 1-10 ◽  
Author(s):  
Zhen Li ◽  
Yang Li ◽  
Jin Li ◽  
Rui Liu ◽  
Jia Hao ◽  
...  

A sensitive and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to simultaneously determine the toxic and other active components including isovanillin, scopoletin, periplocin, periplogenin, and periplocymarin after oral administration of cortex periplocae extract to rats. Plasma samples were prepared by protein precipitation with methanol. All compounds were separated on a C18 column with gradient elution using acetonitrile and formic acid aqueous solution (0.1%, v/v) as the mobile phase at a flow rate of 0.3 mL/min. The detection of all compounds was accomplished by multiple-reaction monitoring (MRM) in the positive electrospray ionization mode. The LC-MS/MS method exhibited good linearity for five analytes. The lower limit of quantification (LLOQ) was 0.48 ng/mL for scopoletin, periplogenin, and periplocymarin; 2.4 ng/mL for isovanillin and periplocin. The extraction recoveries of all compounds were more than 90% and the RSDs were below 10%. It was found that the absorption of scopoletin and periplocin was rapid in vivo after oral administration of cortex periplocae extract. Furthermore, periplocymarin possessed abundant plasma exposure. The results demonstrated that the validated method was efficiently applied for the pharmacokinetic studies of isovanillin, scopoletin, periplocin, periplogenin, and periplocymarin after oral administration of cortex periplocae extract.


2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
Renjie Xu ◽  
Mengyue Wang ◽  
Ying Peng ◽  
Xiaobo Li

Isoalantolactone and alantolactone are two major active ingredients that are present in many medicinal plants. In this study, a sensitive and rapid ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed for determination of the two compounds in rat plasma, separately. In this method, an electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring (MRM) was selected for quantification using target fragment ions 233.2→187.1 for isoalantolactone (alantolactone) and 245.1→189.1 for internal standard (IS). Retention time of the lactones and IS was within 3.0 min. Further calibration suggested a linear regression can be calculated within 2.5–500 ng/mL for isoalantolactone and 4–500 ng/mL for alantolactone. This method was used to compare the pharmacokinetic characteristics of isoalantolactone and alantolactone at a single dose of 5 mg/kg into male Sprague-Dawley rats by intravenous administration separately. The levels oft1/2, Kel, CL,Cmax, and AUC were significantly increased in the alantolactone group compared to isoalantolactone. These results suggested that isoalantolactone was distributed and eliminated more rapidly than alantolactone in rats when administered, respectively.


Author(s):  
Jianwei Han ◽  
Wenbo Zhu ◽  
Ling Yu ◽  
Yajun Chen ◽  
Gaosong Wu ◽  
...  

AbstractA rapid, sensitive and convenient method based on ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) was developed and validated for the simultaneous quantification of calycosin-7-O-β-d-glucoside (CCSG), ononin, calycosin, (6aR,11aR)-9,10-dimethoxypterocarpan-3-O-β-d-glucopyanoside (DPPG), and 7,2′-dihydroxy-3′,4′-dimethoxyisoflavan-7-O-β-d-glucopyanoside (DIFG) in rat plasma after oral administration of the methanol extraction from Radix Astragali. Theophylline played the role of internal standard (IS). Preparation of plasma samples by liquid-liquid extraction method with ethyl acetate after precipitation of protein with methanol. The analytes were detected with a triple quadrupole tandem mass spectrometery (MS) in multiple reaction monitoring (MRM) mode and a positive ion electrospray ionization (ESI). The method was validated with the concentration ranges of 1.96–62.69 ng/mL for CCSG, 1.70–54.5 ng/mL for ononin, 1.85–59.06 ng/mL for calycosin, 2.14–137.24 ng/mL for DPPG and1.96–125.25 ng/mL for DIFG, respectively. The method had the lower limit of quantification (LLOQ) with 0.49, 0.21, 0.92, 1.07, and 0.98 ng/mL for CCSG, ononin, calycosin, DPPG and DIFG respectively, and the precision less than 10%. The RSD of the accuracy was in the range of −4.35–8.91%. The results may be helpful to provide more accurate references to clinical application of this herb.


2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Bo Wang ◽  
Feifei Chen ◽  
Quan Zhou ◽  
Yunfang Zhou ◽  
Deru Meng ◽  
...  

Lusutrombopag is a second oral thrombopoietin (TPO) receptor agonist that selectively acts on human TPO receptors. In the study, UPLC-MS/MS was used to establish a selective and sensitive method to determine lusutrombopag with poziotinib as IS (internal standard) in rat plasma. Samples were prepared by precipitating protein with acetonitrile as a precipitant. Separation of lusutrombopag and poziotinib was performed on a CORTECS UPLC C18 column (2.1 ∗ 50 mm, 1.6 μm). The mobile phase (acetonitrile and water containing 0.1% formic acid) with gradient elution was set at a flow rate of 0.4 ml/min. The mass spectrometric measurement was conducted under positive ion mode using multiple reaction monitoring (MRM) of m/z 592.97 ⟶ 491.02 for lusutrombopag and m/z for poziotinib (IS) 492.06 ⟶ 354.55. The linear calibration curve of the concentration range was 2–2000 ng/ml for lusutrombopag, with a lower limit of quantification (LLOQ) of 2 ng/ml. RSD of interday and intraday precision were both no more than 9.66% with the accuracy ranging from 105.82% to 108.27%. The extraction recovery of lusutrombopag was between 82.15% and 90.34%. The developed and validated method was perfectly used in the pharmacokinetic study of lusutrombopag after oral administration in rats.


2020 ◽  
Vol 13 (11) ◽  
pp. 386
Author(s):  
Oscar Ekpenyong ◽  
Candace Cooper ◽  
Jing Ma ◽  
Naihsuan C. Guy ◽  
Ashley N. Payan ◽  
...  

Background: GMC1 (2-(1H-benzimidazol-2-ylsulfanyl)-N-[(Z)-(4-methoxyphenyl) methylideneamino] acetamide) effectively inhibits androgen receptor function by binding directly to FKBP52. This is a novel mechanism for the treatment of castration resistant prostate cancer (CRPC). Methods: an LC-MS/MS method was developed and validated to quantify GMC1 in plasma and urine from pharmacokinetics studies in rats. An ultra-high-performance liquid chromatography (UHPLC) system equipped with a Waters XTerra MS C18 column was used for chromatographic separation by gradient elution with 0.1% (v/v) formic acid in water and methanol. A Sciex 4000 QTRAP® mass spectrometer was used for analysis by multiple reaction monitoring (MRM) in positive mode; the specific ions [M+H]+m/z 340.995 → m/z 191.000 and [M+H]+ m/z 266.013 → m/z 234.000 were monitored for GMC1 and internal standard (albendazole), respectively. Results: GMC1 and albendazole had retention times of 1.68 and 1.66 min, respectively. The calibration curves for the determination of GMC1 in rat plasma and urine were linear from 1–1000 ng/mL. The LC-MS/MS method was validated with intra- and inter-day accuracy and precision within the 15% acceptance limit. The extraction recovery values of GMC1 from rat plasma and urine were greater than 95.0 ± 2.1% and 97.6 ± 4.6%, respectively, with no significant interfering matrix effect. GMC1 is stable under expected sample handling, storage, preparation and LC-MS/MS analysis conditions. Conclusions: Pharmacokinetic evaluation of GMC1 revealed that the molecule has a biexponential disposition in rats, is distributed rapidly and extensively, has a long elimination half-life, and appears to be eliminated primarily by first order kinetics.


PeerJ ◽  
2021 ◽  
Vol 9 ◽  
pp. e11041
Author(s):  
Rangru Liu ◽  
Hailong Li ◽  
Na Wei ◽  
Yinfeng Tan

Galangin has multiple pharmacological efficacies, such as anti-cancer, anti-inflammation and anti-oxidation. Galangin can be rapidly converted into glucuronidated metabolites in vivo. This study aimed to establish an UFLC-MS/MS analytical method to simultaneously determine the concentrations of two glucuronidated metabolites of galangin, galangin-3-O-β-D-glucuronic acid (GG-1) and galangin-7-O-β-D-glucuronic acid (GG-2) in rat plasma. After oral administration of galangal extract (0.3 g/kg), blood samples were collected from the orbital sinus, then treated by methanol precipitation and further gradient-eluted with Phenomenex Kinetex 2.6 µm XB-C18 column. The mass spectrometer was manipulated in the negative electrospray ionization (ESI) and selected multiple reaction monitoring (MRM) mode for the analytes. The precursor-to-product ion pairs applied for GG-1, GG-2 and chrysin (as the internal standard, IS) were m/z 445.2→269.0, 445.2→268.9 and 253.0→142.9, respectively. The results showed that the linear ranges for both GG-1 and GG-2 were 2.0–2000.0 ng/mL (r2 > 0.995). The inter- and intra-day precision were 89.3%–109.2%, RSD was less than 15%, and the repeatability was good. The recoveries of both metabolites and IS were over 89%, and matrix effect was within 15%. The validated analytical method was further applied to study the pharmacokinetic profiles of GG-1 and GG-2 in vivo. The pharmacokinetic parameters suggested that Tmax of GG-1 was equivalent to that of GG-2, and MRT0-t, t1/2 of GG-2 were a little higher than those of GG-1. Importantly, AUC0-t and Cmax of GG-2 were almost twice as those of GG-1. In short, the validated UFLCMS/MS analytical method was feasible to simultaneously determine two galangin metabolites GG-1 and GG-2 in rat plasma and further analyze in vivo metabolism of galangin.


Sign in / Sign up

Export Citation Format

Share Document