Thermocouple Psychrometer for Field Measurements

1951 ◽  
Vol 32 (6) ◽  
pp. 217-220 ◽  
Author(s):  
F. R. Bellaire ◽  
L. J. Anderson

A new thermocouple psychrometer, designed to indicate true air temperature and humidity in remote locations, is described. In order to minimize maintenance, it utilizes natural ventilation, but provides adequate shielding of sensing elements against radiation. Wet and dry bulb temperature errors of less than + 0.1C° are obtained in winds above 1 mph.

2018 ◽  
Vol 2 (3) ◽  
pp. 144
Author(s):  
Hana Faza Surya Rusyda ◽  
Erni Setyowati ◽  
Gagoek Hardiman

Abstract:. Thermal comfort is a state of mind that expresses a user's satisfaction with thermal conditions. This study focuses on the design of natural ventilation which is one of the efforts to reduce the heat that exists in the building, especially in maintaining the thermal conditions. Tawang Train Station, Semarang has a natural ventilation design that is still maintained especially in the waiting room. This study aims to determine the thermal conditions of the design of ventilation using the theory of Mom and Wiseborn, SNI 03-6572-2001, and Olgyay chart. This research method uses quantitative and field measurements were done for 14 hours to know the movement of air, temperature, humidity. The results were then compared with the standard and the theory. It was found that thermal comfort conditions that still utilize the movement of the wind from natural ventilation in the main waiting room of Tawang Semarang Station.Keyword: Thermal Condition, Natural Ventilation, Semarang Tawang Station.Abstrak: Kenyamanan termal merupakan suatu kondisi pikir seseorang yang mengekspresikan kepuasan pengguna terhadap kondisi termal.  Penelitian ini berfokus pada desain penghawaan yang merupakan salah satu upaya mengurangi panas yang ada dalam bangunan terutama dalam menjaga kondisi termal. Stasiun Tawang Semarang, mempunyai desain penghawaan alami yang masih dipertahannkan terutama pada ruang tungguya. Penelitian ini  bertujuan untuk mengetahui kondisi termal dari desain penghawaan dengan menggunakan teori mom dan wiseborn, SNI 03-6572-2001, serta grafik olgyay. Metode penelitian ini menggunakan kuantitatif dan pengukuran dilapangan dilakukan selama 14 jam untuk mengetahui pergerakan udara, temperature, kelembaban. Hasil penelitian kemudian di bandingkan dengan standar SNI, Mom & Wiseborn dan Diagram Olgyay. Ditemukan bahwa kondisi kenyamanan termal yang masih memanfaatkan pergerakan angin dari ventilasi alami pada ruang tunggu utama Stasiun Semarang Tawang.Kata Kunci: Kondisi Termal, Ventilasi Alami, Ruang tunggu, Stasiun Semarang Tawang


2009 ◽  
Vol 40 (2) ◽  
pp. 45
Author(s):  
Alessandro D'Emilio ◽  
Rosari Mazzarella ◽  
Simona M.C. Porto

The aim of the present paper is to study natural ventilation in a dairy house by means of a parametric analysis relating wind speed and direction to the air flows through the ridge vent of the building. This analysis was carried out by means of an artificial neural network (ANN) which capability in modelling and simulating some climatic parameters inside a dairy house has been validated using the data collected in a trial carried out during summer 2005. The results show that modelling a Generalized feed-forward Multi-Layer Perceptron ANN allowed to obtain satisfactory results in the simulation of air speed and direction and air temperature and humidity inside a dairy house, using as input the values of wind speed and direction and outdoor air temperature and humidity. The adequate accuracy in the simulation of the air motion across the ridge vent allowed to perform a parametric analysis of the ventilation, which provided the values of air speed and direction in function of a fixed range of values of wind speed and direction.


2012 ◽  
Author(s):  
Raphael Linker ◽  
Murat Kacira ◽  
Avraham Arbel ◽  
Gene Giacomelli ◽  
Chieri Kubota

The main objectives were (1) to develop, implement and validate control procedures that would make it possible to maintain year-round air temperature and humidity at levels suitable for crop cultivation in greenhouses operating in arid and semi-arid regions and (2) to investigate the influence of the operational flexibility of the fogging system on the performance of the system. With respect to the development of climate controllers, we developed a new control approach according to which ventilation is used to maintain the enthalpy of the greenhouse air and fogging is used to adjust the humidity ratio inside the greenhouse. This approach is suitable mostly for greenhouses equipped with mechanized ventilation, and in which the air exchange rate can be controlled with enough confidence. The development and initial validation of the controllers were performed in a small experimental greenhouses located at the Agricultural Research Organization and very good tracking were obtained for both air temperature and relative humidity (maximum mean deviations over a 10-min period with constant setpoints lower than 2.5oC and 5% relative humidity). The robust design approach used to develop the controllers made it possible to transfer successfully these controllers to a much larger semi-commercial greenhouse located in the much drier Arava region. After only minimal adjustments, which did not require lengthy dedicated experiments, satisfactory tracking of the temperature and humidity was achieved, with standard deviation of the tracking error lower than 1oC and 5% for temperature and relative humidity, respectively. These results should help promote the acceptance of modern techniques for designing greenhouse climate controllers, especially since given the large variety of greenhouse structures (shape, size, crop system), developing high performance site-specific controllers for each greenhouse is not feasible. In parallel to this work, a new cooling control strategy, which considers the contribution of humidification and cooling from the crop, was developed for greenhouses equipped with natural ventilation. Prior to the development of the cooling strategy itself, three evapotranspiration models were compared in terms of accuracy and reliability. The cooling strategy that has been developed controls the amount of fog introduced into the greenhouse as well as the percentage of vent openings based on the desired vapor pressure deficit (VPD) and enthalpy, respectively. Numerical simulations were used to compare the performance of the new strategy with a constant fogging rate strategy based on VPD, and on average, the new strategy saved 36% water and consumed 30% less electric energy. In addition, smaller air temperature and relative humidity fluctuations were achieved when using the new strategy. Finally, it was demonstrated that dynamically varying the fog rate and properly selecting the number of nozzles, yields additional water and electricity savings.


2019 ◽  
Vol 1 (2) ◽  
Author(s):  
Hanifa Marisa

An investigation had been done to Tetragonula (Tetragona) sp nest at Indralaya, South Sumatra to describe the Tetragonula sp nest that use streetlight pole as nest medium during April - May 2019. Purpossive sampling is used to select the target nest. Two streetlight pole found be used by Tetragonula sp as their home. The coordinate of location, heght from ground surface, diameter of streetlight pole, air temperature and humidity, and floral species around nest, were noted. Spot coordinate are S 30 14’ 19.2498’’ and E 1040 39’ 15,3288’’ ; 1,5 m above the ground surface, 12 cm diameter pole, highest air temperature was 35 o C at daylight (April and May 2019), 80 – 90 % humidity at April-May 2019; which Switenia macrophyla, Hevea brasiliensis, Zea mays, and Citrullus lanatus floral species are planted around. Air temperature in the pole is very high, around 40 0 C during daylight.


2020 ◽  
Vol 13 (1) ◽  
pp. 201
Author(s):  
Pau Chung Leng ◽  
Gabriel Hoh Teck Ling ◽  
Mohd Hamdan Ahmad ◽  
Dilshan Remaz Ossen ◽  
Eeydzah Aminudin ◽  
...  

The provision requirement of 10% openings of the total floor area stated in the Uniform Building By-Law 1984 Malaysia is essential for natural lighting and ventilation purposes. However, focusing on natural ventilation, the effectiveness of thermal performance in landed residential buildings has never been empirically measured and proven, as most of the research emphasized simulation modeling lacking sufficient empirical validation. Therefore, this paper drawing on field measurement investigates natural ventilation performance in terraced housing with an air-well system. The key concern as to what extent the current air-well system serving as a ventilator is effective to provide better thermal performance is to be addressed. By adopting an existing single-story air-welled terrace house, indoor environmental conditions and thermal performance were monitored and measured using HOBO U12 air temperature and humidity, the HOBO U12 anemometer, and the Delta Ohm HD32.3 Wet Bulb Globe Temperature meter for a six-month duration. The results show that the air temperature of the air well ranged from 27.48 °C to 30.92 °C, with a mean relative humidity of 72.67% to 79.25%. The mean air temperature for a test room (single-sided ventilation room) ranged from 28.04 °C to 30.92 °C, with a relative humidity of 70.16% to 76.00%. These empirical findings are of importance, offering novel policy insights and suggestions. Since the minimum provision of 10% openings has been revealed to be less effective to provide desirable thermal performance and comfort, mandatory compliance with and the necessity of the bylaw requirement should be revisited.


2022 ◽  
pp. 1420326X2110564
Author(s):  
Chuanmin Tai ◽  
Guansan Tian ◽  
Wenjun Lei

Condensation is a major issue in the safe operation of utility tunnels. To address the condensation problem, the indoor air temperature, relative humidity (RH) and surface temperature in an urban utility tunnel in Jining were continuously measured, and the condensation conditions were surveyed and analysed. The results indicated that under natural ventilation conditions, the air temperature in the comprehensive cabin varied from 23.4°C to 24.5°C, the RH fluctuated between 86.4% and 95.3%, and the corresponding air dew point temperature (DPT) remained in the range of 22.2°C–22.9°C. The surface temperature of the water supply pipeline ranged from 17.8°C to 18.5°C, which was far lower than the DPT in the tunnel, resulting in serious condensation. A water supply pipeline with an anti-condensation design was developed based on environmental test data. A 25-mm-thick rubber plastic sponge insulation layer was used to thermally insulate the water supply pipeline, preventing further dew condensation. Furthermore, mechanical ventilation had little effect on reducing the RH in the tunnel and may actually cause dew condensation; therefore, a ventilation control mode was proposed in this study. These results are expected to provide basic data for further research and reference for the safe management of utility tunnels.


2012 ◽  
Vol 18 (4) ◽  
pp. CR201-CR208 ◽  
Author(s):  
Jerrold S. Petrofsky ◽  
Lee Berk ◽  
Faris Alshammari ◽  
Haneul Lee ◽  
Adel Hamdan ◽  
...  