Effect of inlet distortion on the performance of axial transonic contra-rotating compressor

Author(s):  
Hanru Liu ◽  
Yangang Wang ◽  
Songchuan Xian ◽  
Wenbin Hu

The present paper numerically conducted full-annulus investigation on the effects of circumferential total pressure inlet distortion on the performance and flow field of the axial transonic counter-rotating compressor. Results reveal that the inlet distortion both deteriorates the performance of the upstream and downstream rotors resulting in reduction of total pressure ratio, efficiency and stall margin of the transonic contra-rotating compressor. Regarding the development of distortion inside compressor, the downstream rotor reinforces the air-flow mixing effects and, thus, attenuates the distortion intensity significantly. Under the distorted inflow conditions, the detached shockwave at the leading edge of downstream rotor interacts with the tip leakage flow and causes the blockage of the blades passage, which is one important reason for the transonic contra-rotating compressor stall.

2021 ◽  
Author(s):  
Subbaramu Shivaramaiah ◽  
Mahesh K. Varpe

Abstract In the present research work, effect of airfoil vortex generator on performance and stability of transonic compressor stage is investigated through CFD simulations. In turbomachines vortex generators are used to energize boundary and generated vortex is made to interact with tip leakage flow and secondary flow vortices formed in rotor and stator blade passage. In the present numerical investigation symmetrical airfoil vortex generator is placed on rotor casing surface close to leading edge, anticipating that vortex generated will be able to disturb tip leakage flow and its interaction with rotor passage core flow. Six different vortex generator configuration are investigated by varying distance between vortex generator trailing edge and rotor leading edge. Particular vortex generator configuration shows maximum improvement of stall margin and operating range by 5.5% and 76.75% respectively. Presence of vortex generator alters flow blockage by modifying flow field in rotor tip region and hence contributes to enhancement of stall margin. As a negative effect, interaction of vortex generator vortices and casing causes surface friction and high entropy generation. As a result compressor stage pressure ratio and efficiency decreases.


Author(s):  
Juan Du ◽  
Joerg R. Seume

Casing treatments (CTs) have been proved to beneficially affect the behavior of tip clearance flow and compressor stability. This paper presents the design of casing treatment for a mixed-flow compressor with a very small tip gap of 0.1mm. In the first part, the potential of applying two traditional types of casing treatments, i.e. circumferential grooves and axial slots, to enhance the stability of a mixed-flow compressor is investigated. The flow details in the reference compressor with smooth casing are examined first. It is found that a separating vortex is formed due to the reversed flow on the blade suction side near the rotor trailing edge at the near-stall point. It is supposed to be responsible for the decrease in total pressure ratio when the compressor approaches to stall. The numerical stall, i.e. the breakdown of the simulation, is initiated from the spillage of tip leakage flow over the rotor blade leading edge. The effect of circumferential grooves on the compressor performances is not remarkable. The implement of axial slots ameliorates the total pressure ratio and extend the flow range substantially, but with higher efficiency penalty than the circumferential grooves. The recirculation formed in the axial skewed slots eliminates the separation vortex near the trailing edge and suppresses the spillage of the tip leakage flow forward the rotor leading edge simultaneously. The axial skewed slots are further designed and optimized numerically by DoE (Design of Experiments). As DoE factors the axial length, the height, the open area ratio, and the number per blade passage of the slots are varied. Their effects on the two target values stall margin and polytropic efficiency are investigated. The plot of stall margin improvement (SMI) with a function of the peak efficiency improvement (PEI) indicates that the SMI changes reversely with the PE. There are two trends in the correlation curves of SMI with PE. For the configurations with the open area ratio of 20%, the SMI is changed from 9% to 23% with 1% decrease in PE by varying other three factors. For the CTs with the open area ratio of 60% the augment in SMI from 17.8% to 26.3% produces extra efficiency loss of 4.2%.


Author(s):  
Hailiang Jin ◽  
Donghai Jin ◽  
Fang Zhu ◽  
Ke Wan ◽  
Xingmin Gui

This paper presents the design of a highly loaded transonic two-stage fan using several advanced three-dimensional blading techniques including forward sweep and “hub bending” in rotors and several bowed configurations in stators. The effects of these blading techniques on the performance of the highly loaded transonic two-stage fan were investigated on the basis of three-dimensional Navier-Stokes predictions. The results indicate that forward sweep has insignificant impact on the total pressure ratio and adiabatic efficiency of the fan. The throttling range of the fan is found to be improved by forward sweep because the shock in the forward swept rotor is expelled later upstream to the leading edge than that in the unswept one. Hub bending design technique increases the efficiency in the hub region of R1 due to the reduction of the low momentum zone in the hub region near the trailing edge. The stator vane design has a pronounced impact on the performance of the fan. The total pressure ratio, adiabatic efficiency, and stall margin of the schemes with the bowed vanes are increased significantly compared to the scheme with the straight vanes. The large corner stall in the straight S1 vane is reduced effectively by the bowed S1 vanes. Moreover, the strong corner stall in the straight S2 vane is fully eliminated by the bowed S2 vanes. Among the bowed vane schemes, the scheme with positive bowed (P. B.) hub and negative bowed (N. B.) tip vanes has the best efficiency and stall margin performances thanks to the superiority of the performance over the midspan regions of the bowed vanes.


Author(s):  
Maoyi Li ◽  
Wei Yuan ◽  
Xizhen Song ◽  
Yajun Lu ◽  
Zhiping Li ◽  
...  

The traditional annulus casing treatment often pays the price of lowered efficiency for improving the stall margin of a compressor under inlet distortion. In view of the unsymmetry of the inlet flow-field of compressors, partial casing treatment was used to control the flow in a transonic axial-flow compressor with arc-skewed-slots deployed at different circumferential positions under inlet distortion. The experimental results indicate that when the partial casing treatment is arranged on the undistorted and distorted sectors, the stall margin is enhanced by 8.02%, with the relative peak efficiency improved simultaneously by 2.143%, compared with the case of solid casing at 98% rotating speed. By contrast, the traditional casing treatment increases the stall-margin by 23.13%, but decreases the relative peak efficiency by 0.752%. By analyzing dynamic and static experimental data, the mechanism underlying the partial casing treatment was also studied in detail here. The disturbances of inlet flow were restrained by annulus casing treatment, nevertheless the total pressure ratio was decreased obviously in the distorted sector. As a result, the stall-margin is improved, but the relative peak efficiency is decreased too. When the partial casing treatment was arranged on the undistortded and distorted sectors, the stall disturbances was thereby restrained. So the stall margin was enhanced. In addition, the total pressure ratio was improved by the partial casing treatment in the distorted and transition sectors, and thus the relative peak efficiency was also increased markedly.


Author(s):  
Guoming Zhu ◽  
Xiaolan Liu ◽  
Bo Yang ◽  
Moru Song

Abstract The rotating distortion generated by upstream wakes or low speed flow cells is a kind of phenomenon in the inlet of middle and rear stages of an axial compressor. Highly complex inflow can obviously affect the performance and the stability of these stages, and is needed to be considered during compressor design. In this paper, a series of unsteady computational fluid dynamics (CFD) simulations is conducted based on a model of an 1-1/2 stage axial compressor to investigate the effects of the distorted inflows near the casing on the compressor performance and the clearance flow. Detailed analysis of the flow field has been performed and interesting results are concluded. The distortions, such as total pressure distortion in circumferential and radial directions, can block the tip region so that the separation loss and the mixing loss in this area are increased, and the efficiency and the total pressure ratio are dropped correspondingly. Besides, the distortions can change the static pressure distribution near the leading edge of the rotor, and make the clearance flow spill out of the rotor edge more easily under near stall condition, especially in the cases with co-rotating distortions. This phenomenon can be used to explain why the stall margin is deteriorated with nonuniform inflows.


Author(s):  
Botao Zhang ◽  
Bo Liu ◽  
Xin Sun ◽  
Hang Zhao

Abstract In order to explore the similarities and differences between the flow fields of cantilever stator and idealized compressor cascade with tip clearance, and to extend the cascade leakage model to compressors, the influence of stator hub rotation to represent cascade and cantilever stator on hub leakage flow was numerically studied. On this basis, the control strategy and mechanism of blade root suction were discussed. The results show that there is no obvious influence on stall margin of the compressor whether the stator hub is rotating or stationary. For rotating stator hub, the overall efficiency is decreased while the total pressure ratio is increased. At peak efficiency point and near stall point, the efficiency is reduced by about 0.43% and 0.34% individually, while the total pressure ratio is enlarged by about 0.23% and 0.27%, respectively. The gap leakage flow is promoted due to stator hub rotation, and the structure of the leakage vortex is weakened obviously. In addition, the hub leakage flow originating from the blade leading edge of rotating hub may contribute to double leakage near the trailing edge of the adjacent blade. However, the leakage flow directly out of the blade passage with stationary stator hub. The stator root loading and strength of the leakage flow increase with the rotation of the hub, and the leakage vortex is further away from the suction surface of the blade and is stretched to an ellipse closer to the endwall under the shear action. The rotating hub makes the flow loss near the stator gap increase, while the flow loss in the upper part of the blade root is decreased. Meanwhile, the total pressure ratio in the end area is increased. Blade root suction of cantilever stator can effectively control the hub leakage flow, inhibit the development of hub leakage vortex, and improve the flow capacity of the passage, thereby reducing the flow loss and modifying the flow field in the end zone.


Author(s):  
Lei Liu ◽  
Fu Chen ◽  
Huanlong Chen ◽  
Yanping Song

For the sake of investigating impact of inlet distortion on the fan stage performance, numerical simulation of the whole structure of a flush-mounted S-shaped inlet and the rear fan stage was conducted in this paper. The single fan stage with uniform air admission was researched at the same time for comparison. Considering substantial boundary layer ingesting, a scheme of suction control imposed at the first bend of the inlet was also carried out. The results show that the total pressure ratio as well as the efficiency of the fan stage decreases dramatically and the choked mass flow has a reduction about 1.20% as compare with the uniform air condition. With suction control, aerodynamic performance of the fan stage improves slightly, the choked mass flow and total pressure ratio at the maximum isentropic efficiency point increase about 0.28% and 0.25% respectively, and the stable operation range is extended. With effect of rotating rotor, the significant low energy region at bottom of the airintake exit decrease continually as it travels downstream to the rotor and covers nearly three flow passages at the front-edge rotor blade, moreover, the high-energy fluid mixes with the low-energy fluid.


Author(s):  
Brian A. Binkley ◽  
Grant T. Patterson ◽  
Jerome C. Jenkins

The A-10 aircraft has fuselage mounted engines with inlets just above the rear of the wing. A deployable slat system is used on the A-10 to delay wing stall directly in front of the engines. Wing stall can lead to high inlet distortion and ultimately engine stall for this aircraft. Many alternate wing leading-edge designs were recently considered for replacement of the slat system to reduce maintenance cost, reduce system complexity and increase system reliability. Fifteen potential wing leading-edge proposals for replacing the A-10 slat system were evaluated through test and analysis. Performance of the wing leading-edge candidates was characterized by the effect of inlet/engine distortion on loss of stability pressure ratio (ΔPRS) for the TF-34 engine fan and compressor. The many protuberances and non-aerodynamic shapes of the A-10 outer mold lines can generate flow structures that cause significant inlet/engine total pressure distortion. Thorough understanding of these flow structures and their impact on inlet/engine distortion was necessary to fully assess the performance of candidate wing leading edge configurations. The paper discusses the integrated test and evaluation tools and methods used to identify the sources of inlet/engine total pressure distortion and the associated impact to engine/airframe integration.


2021 ◽  
Vol 5 ◽  
pp. 79-89
Author(s):  
Ahmad Fikri Mustaffa ◽  
Vasudevan Kanjirakkad

The stall margin of tip-critical axial compressors can be improved by using circumferential casing grooves. From previous studies, in the literature, the stall margin improvement due to the casing grooves can be attributed to the reduction of the near casing blockage. The pressure rise across the compressor as the compressor is throttled intensifies the tip leakage flow. This results in a stronger tip leakage vortex that is thought to be the main source of the blockage. In this paper, the near casing blockage due to the tip region aerodynamics in a low-speed axial compressor rotor is numerically studied and quantified using a mass flow-based blockage parameter. The peak blockage location at the last stable operating point for a rotor with smooth casing is found to be at about 10% of the tip chord aft of the tip leading edge. Based on this information, an optimised single casing groove design that minimises the peak blockage is found using a surrogate-based optimisation approach. The implementation of the optimised groove is shown to produce a stall margin improvement of about 5%.


Author(s):  
Song Huang ◽  
Chuangxin Zhou ◽  
Chengwu Yang ◽  
Shengfeng Zhao ◽  
Mingyang Wang ◽  
...  

Abstract As a degree of freedom in the three-dimensional blade design of axial compressors, the sweep technique significantly affects the aerodynamic performance of axial compressors. In this paper, the effects of backward sweep rotor configurations on the aerodynamic performance of a 1.5-stage highly loaded axial compressor at different rotational design speeds are studied by numerical simulation. The aim of this work is to improve understanding of the flow mechanism of backward sweep on the aerodynamic performance of a highly loaded axial compressor. A commercial CFD package is employed for flow simulations and analysis. The study found that at the design rotational speed, compared with baseline, backward sweep rotor configurations reduce the blade loading near the leading edge but slightly increases the blade loading near the trailing edge in the hub region. As the degree of backward sweep increases, the stall margin of the 1.5-stage axial compressor increase first and then decrease. Among different backward sweep rotor configurations, the 10% backward sweep rotor configuration has the highest stall margin, which is about 2.5% higher than that of baseline. This is due to the change of downstream stator incidence, which improves flow capacity near the hub region. At 80% rotational design speed, backward sweep rotor configurations improve stall margin and total pressure ratio of the compressor. It’s mainly due to the decreases of the rotor incidence near the middle span, which results in the decreases of separation on the suction surface. At 60% rotational design speed, detached shock disappears. Backward sweep rotor configurations deteriorate stall margin of the compressor, but increase total pressure ratio and adiabatic efficiency when the flow rate is lower than that at peak efficiency condition. Therefore, it’s necessary to consider the flow field structure of axial compressors at whole operating conditions in the design process and use the design freedom of sweep to improve the aerodynamic performance.