scholarly journals Diagnostic Performance of Heparin-Platelet Factor 4 Antibodies in the Identification of Heparin-Induced Thrombocytopenia in Cancer Population

Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 4896-4896
Author(s):  
Thein H. Oo ◽  
Cristhiam Mauricio Rojas Hernandez

Introduction: Cancer patients appear to have a higher risk of heparin induced thrombocytopenia (HIT) related complications than non-cancer patients; yet data on the performance of conventional diagnostic tools for HIT in cancer is limited. Our aim was to determine among cancer patients with a 4T score ≥ 4, the performance of the conventional cut-off for HIT antibody testing (IgG anti PF4) to discriminate between serotonin release assay (SRA) positive and negative cases. Methods: Retrospective and prospective analysis of cases (2002-2019) was performed of the electronic medical records of adult cancer patients at MD Anderson Cancer Center with suspected HIT. Cases were included in the analysis if the 4T score was ≥ 4 and investigated with IgG anti-PF4 optical density (HIT OD) and SRA. Logistic regression model and the receiver operating characteristic curves were conducted to identify the sensitivity and specificity of different cut-off points for the HIT OD to discriminate HIT cases based on the SRA status. Results: Among 50 cases, 18 were SRA positive. Median HIT OD was 1.03. At a cut-off point of 0.4, the HIT OD performed with a sensitivity of 0.89 and a specificity of 0.50 to discriminate the cases of SRA positive HIT. When the cut-off HIT OD was 1.0, the sensitivity was 0.78 with a specificity of 0.66. Conclusions: Our findings suggest that in cancer patients the performance of IgG anti-PF4 is similar to that of non-cancer patients for the identification of HIT cases. Disclosures Oo: Janssen and Janssen: Other: Research: site co-investigator ; Medical Education Speakers Network: Honoraria.

2000 ◽  
Vol 124 (11) ◽  
pp. 1657-1666 ◽  
Author(s):  
Fabrizio Fabris ◽  
Sarfraz Ahmad ◽  
Giuseppe Cella ◽  
Walter P. Jeske ◽  
Jeanine M. Walenga ◽  
...  

Abstract Objective.—This review of heparin-induced thrombocytopenia (HIT), the most frequent and dangerous side effect of heparin exposure, covers the epidemiology, pathophysiology, clinical presentation, diagnosis, and treatment of this disease syndrome. Data Sources and Study Selection.—Current consensus of opinion is given based on literature reports, as well as new information where available. A comprehensive analysis of the reasons for discrepancies in incidence numbers is given. The currently known mechanism is that HIT is mediated by an antibody to the complex of heparin–platelet factor 4, which binds to the Fc receptor on platelets. New evidence suggests a functional heterogeneity in the anti-heparin-platelet factor 4 antibodies generated to heparin, and a “superactive” heparin-platelet factor 4 antibody that does not require the presence of heparin to promote platelet activation or aggregation has been identified. Up-regulation of cell adhesion molecules and inflammatory markers, as well as preactivation of platelets/endothelial cells/leukocytes, are also considered to be related to the pathophysiology of HIT. Issues related to the specificity of currently available and new laboratory assays that support a clinical diagnosis are addressed in relation to the serotonin-release assay. Past experience with various anticoagulant treatments is reviewed with a focus on the recent successes of thrombin inhibitors and platelet GPIIb/IIIa inhibitors to combat the platelet activation and severe thrombotic episodes associated with HIT. Conclusions.—The pathophysiology of HIT is multifactorial. However, the primary factor in the mediation of the cellular activation is due to the generation of an antibody to the heparin-platelet factor 4 complex. This review is written as a reference for HIT research.


2007 ◽  
Vol 14 (4) ◽  
pp. 410-414 ◽  
Author(s):  
Suresh G. Shelat ◽  
Anne Tomaski ◽  
Eleanor S. Pollak

Heparin-induced thrombocytopenia (HIT) can lead to life-threatening and limb-threatening thrombosis. HIT is thought to be initiated by the interaction of pathogenic antibodies toward a complex platelet factor 4 (PF4) and heparin (PF4:H), which can activate platelets and predispose to thrombosis. As such, the laboratory diagnosis of HIT includes antigenic and functional assays to detect antibodies directed at PF4:H complexes. We performed a retrospective analysis of 1017 consecutive samples tested by serotonin-release assay and by enzyme-linked immunosorbent assay (ELISA). Most samples showed no serologic evidence of HIT, whereas 4% to 5% of samples demonstrated both antigenic and functional serological evidence for HIT. Approximately 12% to 18% of samples showed immunologic evidence of anti-PF4:H antibodies but without functional evidence of serotonin release in vitro. Interestingly, a small minority of samples (0.7%) caused serotonin release but were negative in the ELISA. The results are presented using cutoff values established at our hospital and for the ELISA manufacturer. This study provides a pretest probability of the serologic results from an antigenic assay (ELISA) and a functional assay (serotonin-release assay) in patients clinically suspected of having HIT.


Blood ◽  
2021 ◽  
Vol 138 (Supplement 1) ◽  
pp. 1957-1957
Author(s):  
Udhayvir Singh Grewal ◽  
Shiva Jashwanth Gaddam ◽  
Sahith Reddy Thotamgari ◽  
Tyiesha Brown ◽  
Kavitha Beedupalli ◽  
...  

Abstract Background: Heparin-induced thrombocytopenia (HIT) is an immune complication of heparin therapy caused by antibodies to complexes of platelet factor 4 (PF4) and heparin. Both clinical probability and laboratory testing are needed for establishing a diagnosis of HIT. The 4Ts clinical scoring system, due to a very high negative predictive value when low, offers a robust means to exclude a diagnosis of HIT. However, these strategies are under-employed in clinical practice and limited evidence indicates a high prevalence of over-testing for HIT. Methods: This retrospective analysis was conducted to identify patients who underwent heparin/PF4 antibody testing over a period of 12 months. The testing was performed using an ELISA-based IgG anti-heparin/PF4 antibody assay and an optical density (OD) of 0.4 was used as a cut-off for a positive value. Electronic medical records were reviewed for 4T score documentation, anti-PF4 results, SRA testing and 4T scores were retrospectively calculated for all the patients. SAS v9.4 (Cary, NC) was used for statistical analysis. Results: A total of 105 patients who underwent anti-PF4 antibody testing were included for analysis. Majority of the patients in our cohort were admitted in an intensive care unit setting (75/105,71.4%). On chart review, only 17 patients (16.2%) were noted to have documentation of 4T score. Based on the retrospectively calculated 4T scores, 60 patients (57.1%) had low pre-test probability, 41 (39%) had intermediate pre-test probability and 4 (3.8%) patients were noted to have high pre-test probability. Anti-PF4/heparin antibodies were positive in 9 patients, of which 5 (55.5%) patients did not undergo concomitant SRA testing. Out of 9, 4 (44.4%) had weakly positive (0.4-1.0 OD units), 2 (21.1%) had strongly positive (1.0-2.0 OD units) and 2 (21.1%) patients had very strongly positive (>2 OD units) anti-PF4 antibody titers. Out of 105 patients, SRA was tested in 11 patients (10.5%) and was noted to be positive in 1 (0.95%). Overall, 2 patients were diagnosed and treated for HIT, out of which the diagnosis was not confirmed with SRA in 1 patient (due to high pre-test probability and very strong anti-PF4 titers). In the remaining patients, sepsis (48, 46.6%) and drug-induced thrombocytopenia (29, 28.2%) emerged as the most common possible causes of thrombocytopenia. Conclusion: Among hospitalized patients, over-testing for HIT is common. Practices to promote 4T score documentation and evidence-based anti-PF4 testing may help prevent unnecessary costs associated with serological testing and costly alternate anticoagulants. To improve overall outcomes, clinicians should also attempt to identify and treat other more likely causes of thrombocytopenia, especially in patients with low pre-test probability for HIT. Disclosures No relevant conflicts of interest to declare.


Blood ◽  
2005 ◽  
Vol 106 (11) ◽  
pp. 3019-3019
Author(s):  
Rowena C. Punzalan ◽  
Sheila J. Hanson ◽  
Nancy Ghanayem ◽  
Brian R. Curtis ◽  
Kathleen Murkowski ◽  
...  

Abstract Heparin is used during cardiopulmonary bypass (CPB) surgery in children. Upon exposure to heparin, heparin-dependent platelet antibodies (HDPA) may form against complexes of platelet factor 4 and heparin on platelet surfaces. Heparin-induced thrombocytopenia (HIT) or heparin-induced thrombocytopenia and thrombosis (HITT) may then ensue. Among adult CPB patients, up to 50% demonstrate HDPA, although only 2% develop HIT and 1% develop HITT. In previous studies done among non-CPB newborns and pediatric intensive care patients, the incidence of HDPA has been zero to minimal. Objective: To determine prevalence of HDPA among children undergoing CPB who are exposed to unfractionated heparin for >120 hours after CPB. Methods: We designed a prospective pilot study. All patients ≤ 12 years old who were to receive heparin during CPB were eligible. The presence of HDPA was assessed by heparin-platelet factor 4 enzyme-linked immunosorbent assay (ELISA); positive and equivocal results were confirmed by serotonin release assay. Blood samples were obtained at the time of cessation of heparin or after 10 days on heparin, whichever came first. Results: Thirty patients were enrolled: 15 were aged 2–19 days (median 6 days); 15 were aged 1.2 to 50 months (median 4.5 months). One patient had borderline positive and 1 had positive results by heparin-platelet factor 4 ELISA; both had negative results by serotonin release assay; neither developed clots. Eighteen patients developed thrombocytopenia, which is common after CPB, including the 2 with equivocal results by ELISA. Six patients, all with negative ELISAs, developed symptomatic thromboses. Conclusion: There were no HDPA identified among children who received unfractionated heparin for CPB. The specificity of heparin-platelet factor 4 ELISA among children should be assessed.


Blood ◽  
2007 ◽  
Vol 110 (11) ◽  
pp. 2096-2096
Author(s):  
Claire Pouplard ◽  
Sandra Regina ◽  
Jean Baptiste Valentin ◽  
Yves Gruel

Abstract Heparin-induced thrombocytopenia (HIT) is associated in most patients with the development of antibodies to heparin-modified platelet factor 4 (PF4). Commercial immuno-assays frequently detect these antibodies after cardiac surgery but only few patients develop clinical HIT. Therefore, platelet activation tests such as serotonin release assay (SRA) are necessary to ensure the diagnosis of HIT with high specificity. Another approach to increase diagnosis specificity could be to detect IgG antibodies which are of major clinical relevance since they are the only class able to directly activate platelets in the presence of heparin. Therefore, we evaluated the performances of a new commercial immuno-assay specific to IgG for the diagnosis of HIT Abs (Zymutest HIA IgG®, Hyphen Biomed, Neuville sur Oise, France). Samples from 101 patients with suspected HIT were analysed. 40 cases had developed significant levels of Abs to PF4 measured with PVS/PF4 ELISA (HAT45®,GTI, Brookfiled, WI, USA) and the diagnosis of HIT had been confirmed since SRA was positive. Every sample was then tested with a global assay named Zymutest HIA G/A/M® as followed: each diluted plasma (200 μl) was incubated for 1 hour with 50 μl of platelet lysate providing PF4 into wells previously coated with unfractionated heparin. After washings and incubation (1 hour) with anti IgG/A/M-HRP immunoconjugate, the enzyme activity was developed and absorbance was read at 450nm. In case of positive result (A450 ≥ 0.5), the isotype distribution was analysed with a specific and standardized assay using monospecific anti-IgG-, anti-IgA- and anti IgM-HRP conjugates (Zymutest HIA-IgG® or -IgA® or -IgM®). A450 values ≥ 0.5 were also considered as positive. GTI assay that detected IgG/A/M Abs to PVS/PF4 complexes in the 40 patients with HIT (Ss 100%) was also positive in 30 of the 61 cases with no HIT (Sp 50.8%). Comparatively, Zymutest HIA® global assay was positive in 39 of the 40 patients with HIT (Ss 97.5%) and in 14 of 61 cases without HIT (Sp 77%). On the other hand, significant levels of heparin-dependent IgG antibodies were also measured in these 39 HIT patients using Zymutest HIA IgG® assay (mean A450: 1.81; range A450: 0.5 – 2.76), and only in 6 patients without HIT (Sp: 90%). However, IgG levels measured in patients without HIT were significantly lower (mean A450: 0.60; range A450: 0.08 – 2.20) than in those with HIT (p < 0.0001). In addition, IgA or IgM heparin-dependent antibodies were only present, i.e. without IgG, in samples from patients for whom the diagnosis of HIT had been ruled out (n = 3). In conclusion, this study supports that the detection of significant levels of IgG heparin-dependent antibodies improves the diagnosis specificity in patients with a suspicion of HIT without loss of sensitivity. Nonetheless, whether IgG-specific immunoassays could avoid to perform platelet activation tests in patients with a strong pre-test probability of HIT warrant further study.


Perfusion ◽  
2020 ◽  
pp. 026765912096510
Author(s):  
Michael Mazzeffi ◽  
Madeline Clark ◽  
Alison Grazioli ◽  
Colleen Dugan ◽  
Raymond Rector ◽  
...  

Background: Heparin induced thrombocytopenia (HIT) is reported at a variable rate in extracorporeal membrane oxygenation (ECMO) patients. A critical factor impacting platelet factor-4 (PF4)-heparin antibody formation is plasma PF4 concentration. We hypothesized that PF4 concentration would be increased during veno-arterial (VA) ECMO. Methods: Plasma PF4 concentration was measured during the first 5 ECMO days in 20 VA ECMO patients and 10 control plasma samples. PF4-heparin ratios were estimated using an assumed heparin concentration of 0.4 IU/mL. This correlates with an activated partial thromboplastin time of 60 to 80 seconds, which is the anticoagulation target in our center. Results: Twenty VA ECMO patients were enrolled, 10 of which had pulmonary embolism. Median PF4 concentration was 0.03 µg/mL [0.01, 0.13] in control plasma. Median PF4 concentration was 0.21 µg/mL [0.12, 0.34] on ECMO day 1 or 2, 0.16 µg/mL [0.09, 0.25] on ECMO day 3, and 0.12 µg/mL [0.09, 0.22] on ECMO day 5. Estimated median PF4-heparin ratios were 0.04, 0.03, and 0.02 respectively. Two patients (10%) developed HIT that was confirmed by serotonin release assay. PF4 concentration did not differ significantly in these patients compared to non-HIT patients (p = 0.37). No patient had an estimated PF4-heparin ratio between 0.7 and 1.4, which is the reported optimal range for PF4-heparin antibody formation. Conclusion: Our data suggest that PF4 concentration is mildly elevated during VA ECMO compared to control plasma. Estimated PF4-heparin ratios were not optimal for HIT antibody formation. These data support epidemiologic studies where HIT incidence is low during VA ECMO.


2020 ◽  
Vol 40 (04) ◽  
pp. 472-484
Author(s):  
Theodore E. Warkentin

AbstractHeparin-induced thrombocytopenia (HIT) is an antibody-mediated hypercoagulable state featuring high thrombosis risk and distinct pathogenesis involving immunoglobulin G-mediated platelet activation. The target of the immune response is a cationic “self” protein, platelet factor 4 (PF4), rendered antigenic by heparin. A key problem is that only a minority of anti-PF4/polyanion antibodies induced by heparin are pathogenic, i.e., capable of causing platelet activation and thereby clinical HIT. Since thrombocytopenia occurs frequently in hospitalized, heparin-treated patients, testing for “HIT antibodies” is common; thus, the problem of distinguishing between pathogenic and nonpathogenic antibodies is important. The central concept is that those antibodies that have platelet-activating properties demonstrable in vitro correlate well with pathogenicity, as shown by platelet activation tests such as the serotonin-release assay (SRA) and heparin-induced platelet activation assay. However, in most circumstances, immunoassays are used for first-line testing, and so it is important for clinicians to appreciate which immunoassay result profiles—in the appropriate clinical context—predict the presence of platelet-activating antibodies (Bayesian analysis). Clinicians with access to rapid, on-demand HIT immunoassays (e.g., particle gel immunoassay, latex immunoturbidimetric assay, chemiluminescent immunoassay) can look beyond simple dichotomous result interpretation (“negative”/“positive”) and incorporate semiquantitative interpretation, where, for example, a strong-positive immunoassay result (or even combination of two immunoassays) points to a greater probability of detecting platelet-activating antibodies, and hence supporting a diagnosis of HIT. Recent recognition of “SRA-negative HIT” has increased the importance of semiquantitative interpretation of immunoassays, given that strong immunoassay reactivity is a potential clue indicating possible HIT despite a (false) negative platelet activation assay.


Blood ◽  
2018 ◽  
Vol 132 (Supplement 1) ◽  
pp. 1143-1143
Author(s):  
Caroline Vayne ◽  
Marc-Antoine May ◽  
Thierry Bourguignon ◽  
Eric Lemoine ◽  
Eve-Anne Guéry ◽  
...  

Abstract Introduction: Extra-Corporeal Membrane Oxygenation (ECMO) provides circulatory support in case of severe cardiac failure and is associated, as cardiopulmonary bypass, with strong activation of platelets, which likely leads to the release in patient blood of large amounts of platelet factor 4 (PF4). Therefore, systematic use of unfractionated heparin (UFH) for maintaining patency of circuits and to prevent thrombosis, exposes patients to heparin-induced thrombocytopenia (HIT). However, the risk of HIT in this particular clinical setting remains poorly documented. Objectives: In this monocentric study, the frequency of development of antibodies to PF4 modified by heparin (anti-PF4/H Abs) was prospectively evaluated in patients who had underwent ECMO, and the impact of these Abs on platelet count (PC) and clinical course was assessed. Patients and Methods: From February 2014 to January 2018, we enrolled in the University Hospital of Tours all consecutive adult patients with ECMO and treated with UFH for at least 5 days. Plasma samples were collected daily, and PF4-specific Abs were systematically detected using HAT45® (GTI), an ELISA assaying IgG, IgA and IgM isotypes, and another kit specific for IgG to modified PF4 (HAT45G®; GTI). Serotonin release assay (SRA) was also performed to detect platelet-activating Abs (and therefore potentially pathogenic) in plasma samples containing significant levels of anti-PF4/H IgG. Noticeably, SRA was also done after adding 10 μg/ml of PF4 in the reaction mixture (PF4-SRA), since we recently showed this modification might improve the detection of pathogenic HIT antibodies (Vayne et al, Brit J Haematol, 179(5):811-819, 2017). Demographics, PC, and clinical events were collected in all patients until the end of ECMO. Results: Fifty-seven patients with a median age of 57 years (range: 24-76) and who were mainly men (sex ratio W/M: 0.3) were enrolled. ECMO was performed due to medical issues (dilated cardiomyopathy, myocardial infarction, acute myocarditis) in 70 % of cases and in surgical settings in the others. Significant titres of anti-PF4/H IgG/A/M Abs were detected before ECMO in 6 of 57 patients (10.5%), with anti-PF4/H IgG present in only 3 cases (5%). After ECMO was initiated, 28 patients (49%) developed IgG/A/M anti-PF4/H Abs, with anti-PF4/H IgG present in 17 of them (30%). Half of these patients were immunized within 5 days after ECMO initiation and 95% of them within 10 days, with a median delay of 8 days before Abs detection (range: 4-26 days). Only 3 patients (5%) exhibited pathogenic anti-PF4/H IgG with positive SRA and the level of platelet release was always stronger when the test was performed with exogenous PF4 (SRA-PF4). Moreover, in one patient, pathogenic HIT Abs were detected earlier by PF4-SRA, i.e. 2 days before conventional SRA was positive. An abnormal PC pattern was evidenced in 2 of the 3 patients with positive SRA, with a dramatic PC fall after day 5 (of 49% and 31.5 % between days 9-10 and 5-6 respectively). The diagnosis of HIT was confirmed in these 2 cases, which also had suggestive clinical manifestations (arterial thrombosis and cutaneous necrosis). In the third patient, HIT was not suspected, because of low PC before ECMO with persistent thrombocytopenia post-operatively and early death on day 9. In the patients with negative SRA, the development of anti-PF4/H IgG did not appear to impact the biological and clinical evolution, with similar rates of thrombosis and death than in non-immunized patients. Therefore, patients with non-pathogenic anti-PF4/H IgG displayed the same PC pattern than non-immunized patients, with decreasing PC from ECMO initiation until day 5, followed by a slow PC recovery. Conclusion: The development of anti-PF4/H Abs is frequent during ECMO but these antibodies are rarely pathogenic, and not associated with a less favourable prognosis. PC evolution analysis during ECMO appears reliable for suspecting HIT, and a dramatic PC fall or a non-recovery of PC after day 5 should prompt to look for platelet-activating anti-PF4/H Abs. Therefore, IgG specific immunoassays should always be combined with platelet activation tests to improve the specificity of HIT diagnosis in this particular clinical condition. Interestingly, the addition of exogenous PF4 when performing SRA could allow an earlier detection of HIT pathogenic antibodies in patients undergoing ECMO. Disclosures No relevant conflicts of interest to declare.


Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 4935-4935
Author(s):  
Tatsiana Mardovina ◽  
John G Chromczak ◽  
Paul W Riley

BACKGROUND: Heparin-induced thrombocytopenia (HIT) is an adverse complication of unfractionated and low molecular weight heparin caused by antibodies recognizing platelet factor 4-heparin (PF4/hep) complexes leading to platelet activation. The diagnosis of HIT is based on the combination of the clinical picture, using the 4T score along with screening and confirmatory methods to detect platelet activating anti‐PF4/H antibodies. OBJECTIVES: Performance was evaluated for two enzyme linked immunosorbent assays (ELISAs), 1) Asserachrom HPIA , Diagnostica Stago Inc., Parsippany, NJ, USA and 2) LIFECODES PF4 Enhanced, Immucor, Inc., Norcross, GA, USA for screening-based detection of PF4/hep antibodies. METHODS: ELISA assays were run per manufacturer recommendations and adapted for automation on a Dynex DS2 automated ELISA platform. Performance characteristics of the two immunoassays were assessed, including sensitivity, specificity, concordance with serotonin release assay (SRA), positive predictive value (PPV) and negative predictive value (NPV). 21 samples were used in the study. Results: Both assays, Asserachrom HPIA and LIFECODES PF4 Enhanced demonstrated 100% sensitivity and NPV, confirming both assays' reliability to detect and rule out HIT (see table). The diagnostic specificity was significantly higher for Asserachrom HPIA vs. LIFECODES PF4 Enhanced (77.8% vs 31.6%). Asserachrom HPIA showed fewer false positive results, with PPV of 42.9% for Asserachrom HPIA vs. 13.3% for LIFECODES PF4 Enhanced. No false negative results were found for either assay. Asserachrom HPIA demonstrated 81.0% concordance with SRA, vs. 38.1% for LIFECODES PF4 Enhanced. CONCLUSIONS: HIT is a life-threatening disorder, with diagnosis depending on clinical findings using the 4T score along with laboratory evaluation. Combining the 4T score with PF4/hep antibody screening increases the accuracy of excluding HIT. Our observations indicate Asserachrom HPIA provides results with high sensitivity and specificity, minimizing false positivess, allowing use of alternative anticoagulants more selectively in at risk patients, to potentially improve patient management while minimizing costs. Disclosures Mardovina: Diagnostica Stago, Inc.: Employment. Chromczak:Diagnostica Stago, Inc.: Employment. Riley:Diagnostica Stago, Inc.: Employment.


Blood ◽  
2021 ◽  
Vol 138 (Supplement 1) ◽  
pp. 3209-3209
Author(s):  
Edward C.C. Wong ◽  
Laura A. Worfolk ◽  
Caixia Bi ◽  
Lina J. Noh ◽  
Andrew Espinoza ◽  
...  

Abstract Introduction: Antibodies that cause heparin-induced thrombocytopenia (HIT) can be detected with either antigenic or functional assays. Previously, it has been shown that antigenic (ELISA based) assays that detect anti-platelet factor 4 (anti-PF4) IgG, IgM, or IgA (polyspecific) antibodies are more sensitive but less specific than functional assays such as the unfractionated serotonin release assay (UFH SRA), and that the use of anti-PF4 assays that detect IgG antibodies only, would increase the specificity but decrease the sensitivity of these assays for the detection of HIT antibodies that are prothrombotic (associated with positive functional assay). To date large epidemiologic studies have not confirm these findings. To evaluate the relative performance of anti-PF4 polyspecific and IgG-specific antibodies in their ability to detect prothrombotic HIT antibodies, we evaluated results of non-reflexive HIT panels that contained either anti-PF4 polyspecific or IgG-specific assays and unfractionated heparin serotonin release assays over an eight-year period at a U.S. reference laboratory. Methods: Test results for 2 HIT detection panels were compared: 1 panel had UFH SRA plus the polyspecific PF4 ENHANCED® assay (GTI Diagnostics, Waukesha, WI) and 1 panel had UFH SRA plus the IgG-specific Zymutest HIA IgG assay (Hyphen Biomed, France). Test results were from the last 4 years of use for each panel (2009 to 2012 for the polyspecific panel; 2017 to 2020 for the IgG-specific panel). UFH SRA was performed as described by Sheridan et al, (1986) with positivity defined as ≥20% serotonin release by low dose UFH and >50% suppression of release at high dose (100 U/mL) UFH. For each year and assay, test results were stratified by optical density (OD) results, and the percent of results positive by UFH SRA was determined for each OD range. Median yearly UFH SRA positivity rates for each OD interval were compared for anti-PF4 polyspecific vs IgG-specific antibody assays using non-parametric statistical testing, Mann-Whitney U test, two-tailed, with significance defined as <0.05. Results: HIT panels with either ELISA based assays detecting either anti-PF4 polyspecific or IgG specific antibodies demonstrated increasing UFH SRA positivity rates as OD increased. Approximately 50% UFH SRA positivity occurred when OD was in the 2.000 to range. No significant differences in SRA positivity were seen at any positive OD interval when comparing anti-PF4 polyspecific vs IgG-specific assays. A small but significant difference was seen when OD results were considered This observation may have been due to a in the review process (2017-2020): when a UFH SRA result was positive with a negative OD result, repeat UFH SRA testing was performed. Conclusions: Our study demonstrates that the correlations of UFH SRA positivity and OD measurements are similar for anti-PF4 IgG-specific and polyspecific antibody assays. These results suggest the assay types may perform similarly for the detection of HIT and importantly provide important predictive information as to when an optical density value will lead to a positive UFH SRA result. Figure 1 Figure 1. Disclosures Wong: Quest Diagnostics: Current Employment, Current equity holder in publicly-traded company, Current holder of individual stocks in a privately-held company, Current holder of stock options in a privately-held company. Worfolk: Quest Diagnostics: Current Employment. Bi: Quest Diagnostics: Current Employment. Noh: Quest Diagnostics: Current Employment. Espinoza: Quest Diagnostics: Current Employment. Wu: Quest Diagnostics: Current Employment. Sahud: Quest Diagnostics: Current Employment. Racke: Quest Diagnostics: Current Employment. Dlott: Quest Diagnostics: Current Employment.


Sign in / Sign up

Export Citation Format

Share Document