HfO2 Thin Film for Microelectromechanical Systems Application

2017 ◽  
pp. 699-718
Author(s):  
Bing Miao ◽  
Alton B. Horsfall
2018 ◽  
Vol 140 (3) ◽  
Author(s):  
Chia-Cheng Chang ◽  
Sheng-Da Lin ◽  
Kuo-Ning Chiang

The fatigue characteristics of microelectromechanical systems (MEMS) material, such as silicon or polysilicon, have become very important. Many studies have focused on this topic, but none have defined a good methodology for extracting the applied stress and predicting fatigue life accurately. In this study, a methodology was developed for the life prediction of a polysilicon microstructure under bending tests. Based on the fatigue experiments conducted by Hocheng et al. (2008, “Various Fatigue Testing of Polycrystalline Silicon Microcantilever Beam in Bending,” Jpn. J. Appl. Phys., 47, pp. 5256–5261) and (Hung and Hocheng, 2012, “Frequency Effects and Life Prediction of Polysilicon Microcantilever Beams in Bending Fatigue,” J. Micro/Nanolithogr., MEMS MOEMS, 11, p. 021206), cantilever beams with different dimensions were remodeled with mesh control technology using finite element analysis (FEA) software to extract the stress magnitude. The mesh size, anchor boundary, loading boundary, critical stress definition, and solution type were well modified to obtain more correct stress values. Based on the new stress data extracted from the modified models, the optimized stress-number of life curve (S–N curve) was obtained, and the new life-prediction equation was found to be referable for polysilicon thin film life prediction under bending loads. After comparing the literature and confirming the new models, the frequency effect was observed only for the force control type and not for the displacement control type.


2008 ◽  
Vol 1139 ◽  
Author(s):  
Kwangsik Kwak ◽  
Masaaki Otsu ◽  
Kazuki Takashima

AbstractFatigue properties of thin film materials are extremely important to design durable and reliable microelectromechanical systems (MEMS) devices. However, it is rather difficult to apply conventional fatigue testing method of bulk materials to thin films. Therefore, a fatigue testing method fitted to thin film materials is required. In this investigation, we have developed a fatigue testing method that uses a resonance of cantilever type specimen prepared from thin films. Cantilever beam specimens with dimensions of 1(W) × 3(L) × 0.01(t) mm3 were prepared from Ni-P amorphous alloy thin films and gold foils. In addition, cantilever beam specimens with dimension of 3(L) × 0.3(W) × 0.005(t) mm3 were also prepared from single crystalline silicon thin films. These specimens were fixed to a holder that is connected to an golddio speaker used as an actuator, and were resonated in bending mode. In order to check the validity of this testing method, Young's moduli of these specimens were measured from resonant frequencies. The average Young's modulus of Ni-P was 108 GPa and that of gold foil specimen was 63 GPa, and these values were comparable with those measured by other techniques. This indicates that the resonance occurred theoretically-predicted manner and this testing method is valid for measuring the fatigue properties of thin films. Resonant fatigue tests were carried out for these specimens by changing amplitude range of resonance, and S-N curves were successfully obtained.


Author(s):  
Runar Plunnecke Dahl-Hansen ◽  
Frode Tyholdt ◽  
Jo Gjessing ◽  
Andreas Vogl ◽  
Paul Wittendorp ◽  
...  

Sensors ◽  
2020 ◽  
Vol 20 (7) ◽  
pp. 2133 ◽  
Author(s):  
Anna Persano ◽  
Fabio Quaranta ◽  
Antonietta Taurino ◽  
Pietro Aleardo Siciliano ◽  
Jacopo Iannacci

In this work, SiNx/a-Si/SiNx caps on conductive coplanar waveguides (CPWs) are proposed for thin film encapsulation of radio-frequency microelectromechanical systems (RF MEMS), in view of the application of these devices in fifth generation (5G) and modern telecommunication systems. Simplification and cost reduction of the fabrication process were obtained, using two etching processes in the same barrel chamber to create a matrix of holes through the capping layer and to remove the sacrificial layer under the cap. Encapsulating layers with etch holes of different size and density were fabricated to evaluate the removal of the sacrificial layer as a function of the percentage of the cap perforated area. Barrel etching process parameters also varied. Finally, a full three-dimensional finite element method-based simulation model was developed to predict the impact of fabricated thin film encapsulating caps on RF performance of CPWs.


1999 ◽  
Author(s):  
John J. Gill ◽  
Ken Ho ◽  
Gregory P. Carman

Abstract Thin film SMA (Shape memory alloy) is a useful method for MEMS (Microelectromechanical Systems) actuator. This is because the thin film has an improved frequency response compared to bulk SMA, high work density, and produces large strain. A novel two-way thin film NiTi (Nickel Titanium) shape memory alloy actuator is presented in this paper. Thin film shape memory alloy is sputter-deposited onto a silicon wafer in an ultra high vacuum system. Transformation temperatures of the deposited NiTi film are measured by residual stress measurement at temperatures from 25 ° C to 120 ° C. Test results show that the Mf (Martensite Finish Temperature) is around 60 ° C and Af (Austenite Finish Temperature) is around 110 ° C. A free standing NiTi membrane (10 mm × 10mm and 3 μm thick) is fabricated using MEMS technology. We found that a mixture of HF (Hydro Fluidic Acid), HNO3 (Nitric Acid) and DI (Deionized) water with thick photo resist mask works best for the fabrication process. The membrane is hot-shaped in different shapes such as dome shape, pyramidal shape, and cylindrical shape. Results indicate that when the temperature of the NiTi film exceeds Af, the NiTi membrane transforms into the trained hot-shape. When the temperature cools down to room temperature, the membrane returns to the initial flat shape.


2000 ◽  
Author(s):  
John J. Gill ◽  
Gregory P. Carman

Abstract Thin film SMA (Shape memory alloy) is a useful material for MEMS (Microelectromechanical Systems) actuator. This is because the thin film has an improved frequency response compared to bulk SMA, high work density, and produces large strain. A novel two-way thin film NiTi (Nickel Titanium) shape memory alloy actuator is presented in this paper. Thin film shape memory alloy is sputter-deposited onto a silicon wafer in an ultra high vacuum system. Transformation temperatures of the NiTi film are determined by measuring the residual stress as a function of temperature. Test results show that the Martensite-Temperature-Finish (Mf) is approximately 60° C, and the Austenite-Temperature-Finish (Af) is 110° C. A free standing NiTi membrane (12 mm × 12 mm and 2.5 μm thick) is fabricated using MEMS technology. We found that a mixture of HF (Hydro Fluoric Acid), HNO3 (Nitric Acid) and DI (Deionized) water with thick photo resist mask works best for the fabrication process. The membrane is hot-shaped into a dome shape. Results indicate that when the temperature of the NiTi film exceeds Af, the NiTi membrane transforms into the trained hot-shape. When the temperature cools down to room temperature, the membrane returns to the initial flat shape. The performance of the SMA micro actuator is characterized with a laser measurement system for deflection vs. input power and frequency response. The maximum deflection of SMA microactuator is 230 μm. The corresponding frequency responses at the maximum deflection are 30 Hz with Copper (Cu) block placed underneath the microactuator and less than 1 Hz when Plexi-glass is placed.


2015 ◽  
Vol 9 (6) ◽  
pp. 662-667 ◽  
Author(s):  
Junpei Sakurai ◽  
◽  
Seiichi Hata

In this paper, we investigate the characteristics of Ti-Ni-Zr thin film metallic glasses (TFMGs)/ shape memory alloys (SMAs) for microelectromechanical systems (MEMS) applications with three-dimensional structures. The amorphous Ti-Ni-Zr thin films having a Ni content of more than 50 at.% and Zr content of more than 11 at.% undergo glass transitions and are TFMGs. The Ti39Ni50Zr11TFMG has the lowest glass transition temperatureTgof 703 K and a wide supercooled liquid region ΔTof 57 K. Moreover, it has high thermal stability atTg. However, the apparent viscosity of the Ti39Ni50Zr11is higher than those of other Ti-Ni-Zr TFMGs. Moreover, the Ti-Ni-Zr TFMG exhibits higher viscosity than conventional TFMGs because the alloy composition of Ti-Ni-Zr TFMGs/SMAs is far from the eutectic point.


2003 ◽  
Vol 125 (4) ◽  
pp. 361-367 ◽  
Author(s):  
Xiaoqin Huang ◽  
Assimina A. Pelegri

MEMS (MicroElectroMechanical Systems) are composed of thin films and composite nanomaterials. Although the mechanical properties of their constituent materials play an important role in controlling their quality, reliability, and lifetime, they are often found to be different from their bulk counterparts. In this paper, low-k porous silica thin films spin coated on silicon substrates are studied. The roughness of spin-on coated porous silica films is analyzed with in-situ imaging and their mechanical properties are determined using nanoindentation. A Berkovich type nanoindenter, of a 142.3 deg total included angle, is used and continuous measurements of force and displacements are acquired. It is shown, that the measured results of hardness and Young’s modulus of these films depend on penetration depth. Furthermore, the film’s mechanical properties are influenced by the properties of the substrate, and the reproduction of the force versus displacement curves depends on the quality of the thin film. The hardness of the studied low-k spin coated silica thin film is measured as 0.35∼0.41 GPa and the Young’s modulus is determined as 2.74∼2.94 GPa.


Sign in / Sign up

Export Citation Format

Share Document