scholarly journals Experimental assessment of three electrosurgical tissue-sealing devices in a porcine model

Author(s):  
Miklós Pál Dunay ◽  
Zsuzsanna Lipcsey ◽  
Attila Arany-Tóth ◽  
Tibor Németh ◽  
Norbert Solymosi ◽  
...  

AbstractThree electrosurgical tissue-sealing devices (EnSeal ETSDRC-01, LigaSure LS1500 and Thunderbeat TB-0535PC) were compared regarding sealing time (ST), maximum working temperature (WTmax) and the total (MTZtotal) as well as the collateral microscopic thermal injury zone (MTZcollat) using laparoscopic handpieces 5 mm in diameter on four types of tissue (liver, mesentery, cross striated muscle and spleen) in an in vivo porcine model. LigaSure had the lowest mean ST in spleen, mesentery, muscle and liver, followed by Thunderbeat and EnSeal with significant differences between all types of tissues and devices. The significantly lowest mean WTmax was obtained for EnSeal in mesentery, muscle and liver. LigaSure and EnSeal operated at the lowest temperature in spleen without a significant difference between them. Thunderbeat produced significantly higher temperature peaks in all cases. The lowest mean MTZtotal was caused by LigaSure and EnSeal in spleen, mesentery and muscle without significant differences between them, followed by the significantly higher values of Thunderbeat. Nevertheless, Thunderbeat produced the significantly lowest mean MTZtotal in the liver. EnSeal produced the lowest mean MTZcollat in the liver, followed by LigaSure and Thunderbeat showing significant differences. EnSeal and LigaSure produced the lowest mean MTZcollat in the spleen, mesentery and muscle without significant differences between them, followed by the significantly higher values of Thunderbeat. Based on the results of this study, Thunderbeat seems to be more invasive to tissue integrity (even without the activation of the ultrasonic scissor function) than EnSeal or LigaSure, that operate at lower temperatures and were found to cause negligible collateral thermal damage.

2010 ◽  
Vol 47 (2) ◽  
pp. 184-187 ◽  
Author(s):  
Luciano Lenz ◽  
Veruska Di Sena ◽  
Frank S. Nakao ◽  
Gustavo Paulo de Andrade ◽  
Maria Rachel da Silveira Rohr ◽  
...  

CONTEXT: Endoscopic mucosal resection is an established modality for excision of sessile lesions in the gastrointestinal tract. Submucosal fluid injection creates a cushion and may prevent thermal injury and perforation. OBJECTIVES: This blind study investigated the performance of three different solutions to create submucosal fluid cushions in porcine stomach. METHODS: Three solutions were injected in the stomach of nine pigs BR1: normal saline solution, carboxymethylcellulose 0.5% and hydroxypropyl methylcellulose 0.25%. In each pig, submucosal injections with 6 mL per test-solution were performed. One drop of methylene blue was added to all injections for better visualization. The time for the bleb to disappear was recorded. RESULTS: The overall median time of visible submucosal cushion was 37 minutes (range 12-60 min) for hydroxypropyl methylcellulose, 31 minutes for carboxymethylcellulose (range 10-43 min) and 19 minutes for normal saline solution (range 8-37 min). There was no statistically significant difference neither between normal saline solution and carboxymethylcellulose (P = 0.146) nor carboxymethylcellulose and hydroxypropyl methylcellulose (P = 0.119) but the median duration of hydroxypropyl methylcellulose was significantly longer than normal saline solution (P = 0.039). CONCLUSIONS: The length of hydroxypropyl methylcellulose submucosal fluid cushion is longer in comparison with normal saline solution. The median time for carboxymethylcellulose was not longer than normal saline solution. Hydroxypropyl methylcellulose, in the concentration of 0.25%, may be a durable alternative for submucosal injection.


2021 ◽  
Vol 39 ◽  
Author(s):  
Aman Prasad ◽  
◽  
Jessica Durrant ◽  
Daniel Smeak ◽  
Jason Newman ◽  
...  

Introduction: Bipolar electrocautery devices used to achieve intraoperative hemostasis carry risk of imparting thermal energy to adjacent tissue, leading to postoperative morbidity. The aim of this study was to compare a new vessel sealing device, the CoolSeal™ Reveal (Bolder Surgical, Louisville, Colorado), with an established industry standard device, the LigaSure™ Exact Dissector (Valleylab, Boulder, Colorado), to assess their safety and the extent to which they impart thermal damage to tissue during thyroid surgery. Materials and Methods: Vascular bundles associated with the thyroid gland in anesthetized sheep were exposed and sealed with a single activation of each device and excised en bloc. Additionally, vascular structures of the sheep were also sealed 0, 1, or 2mm adjacent to the recurrent laryngeal nerve (RLN). Vascular and RLN samples were processed for histopathologic evaluation and assessed for extent of thermal injury, seal width, and coagulative changes. Results: The mean thermal injury extent across all sample sizes and vessel types was significantly lower for the CoolSeal™ Reveal device (547.2 ± 27.9μm) compared to the LigaSure™ device (802.7± 48.6μm) (p<0.001). Seal widths were significantly smaller in samples sealed with the CoolSeal™ Reveal device (899.0 ± 14.9μm) than samples sealed with the LigaSure™ device (1645.3 ± 160.3μm) (p<0.001). Conclusion: The CoolSeal™ Reveal device demonstrates significantly lower thermal spread in vivo compared to the LigaSure™ Exact Dissector. These results indicate that the CoolSeal™ Reveal is an effective tool for sealing blood vessels and minimizing thermal damage to adjacent structures during delicate surgeries or in narrow surgical fields associated with the thyroid gland.


VASA ◽  
2020 ◽  
Vol 49 (4) ◽  
pp. 281-284
Author(s):  
Atıf Yolgosteren ◽  
Gencehan Kumtepe ◽  
Melda Payaslioglu ◽  
Cuneyt Ozakin

Summary. Background: Prosthetic vascular graft infection (PVGI) is a complication with high mortality. Cyanoacrylate (CA) is an adhesive which has been used in a number of surgical procedures. In this in-vivo study, we aimed to evaluate the relationship between PVGI and CA. Materials and methods: Thirty-two rats were equally divided into four groups. Pouch was formed on back of rats until deep fascia. In group 1, vascular graft with polyethyleneterephthalate (PET) was placed into pouch. In group 2, MRSA strain with a density of 1 ml 0.5 MacFarland was injected into pouch. In group 3, 1 cm 2 vascular graft with PET piece was placed into pouch and MRSA strain with a density of 1 ml 0.5 MacFarland was injected. In group 4, 1 cm 2 vascular graft with PET piece impregnated with N-butyl cyanoacrylate-based adhesive was placed and MRSA strain with a density of 1 ml 0.5 MacFarland was injected. All rats were scarified in 96th hour, culture samples were taken where intervention was performed and were evaluated microbiologically. Bacteria reproducing in each group were numerically evaluated based on colony-forming unit (CFU/ml) and compared by taking their average. Results: MRSA reproduction of 0 CFU/ml in group 1, of 1410 CFU/ml in group 2, of 180 200 CFU/ml in group 3 and of 625 300 CFU/ml in group 4 was present. A statistically significant difference was present between group 1 and group 4 (p < 0.01), between group 2 and group 4 (p < 0.01), between group 3 and group 4 (p < 0.05). In terms of reproduction, no statistically significant difference was found in group 1, group 2, group 3 in themselves. Conclusions: We observed that the rate of infection increased in the cyanoacyrylate group where cyanoacrylate was used. We think that surgeon should be more careful in using CA in vascular surgery.


Author(s):  
Tamilarasi G P ◽  
Sabarees G

Oxidation is an essential reaction in the human body, which determines the expression of proteins in the body. This results in the altered expression like rapid growth resulting in cancers and other disorders. Many synthetic drugs are available in the market that is effective in limiting the free radical generation and the reaction of radicals with cells. Unfortunately, all those synthetic drugs were found to cause side effects and adverse effects in the body. But given the accuracy of the predictability of the results and administration, this research focuses on testing the anti-oxidant efficiency in rat models testing the biochemical parameters. Investigations have also been done on the anti-oxidant activity of Tectona, but every research was concentrated to prove the anti-oxidant activity only. extract had been tested for anti-oxidant activity by estimating various tissue parameters and it showed better activity. As predicted, there is a significant difference in the and results which can be explained are due to the physiological conditions that exist inside the body.


Author(s):  
Miriam del Carmen Carrasco-Portugal ◽  
Francisco Javier Flores-Murrieta

Pharmaceutical alternatives are products with the same active moiety, but different salt, ester or pharmaceutical form. Regulatory agencies have different criteria for this kind of drug. The European Medicines Agency (EMA) accepts the generic substitution using these alternatives, whereas the Food and Drug Administration (FDA) only authorizes generic substitution of pharmaceutical equivalents. The objective of this paper is to describe some relevant aspects that should be considered before deciding on making a generic substitution with pharmaceutical alternatives. It is important to note that a pharmaceutical alternative must show no significant difference in the rate and extent of absorption (bioequivalence) in a well-conducted in vivo study when compared with the reference formulation. Current Mexican regulations state that generic substitution is possible using pharmaceutical alternatives when bioequivalence is demonstrated in in vivo studies conducted under the NOM-177-SSA1-2013 criteria. In conclusion, generic substitution with pharmaceutical alternatives is possible if these products demonstrate in vivo bioequivalence when compared with the reference product.


2020 ◽  
Vol 10 (2) ◽  
pp. 133-148
Author(s):  
Ankaj Kaundal ◽  
Pravin Kumar ◽  
Rajendra Awasthi ◽  
Giriraj T. Kulkarni

Aim: The study was aimed to develop mucoadhesive buccal tablets using Aster ericoides leaves mucilage. Background : Mucilages are naturally occurring high-molecular-weight polyuronides, which have been extensively studied for their application in different pharmaceutical dosage forms. Objective: The objective of the present research was to establish the mucilage isolated from the leaves of Aster ericoides as an excipient for the formulation of the mucoadhesive buccal tablet. Method: The mucilage was isolated from the leaves of Aster ericoides by maceration, precipitated with acetone and characterized. Tablets were prepared using wet granulation technique and evaluated for various official tests. Results: The mucilage was found to be non-toxic on A-431 and Vero cell lines. It was insoluble but swellable in cold and hot water. The results indicate that mucilage can form a three-dimensional network. The pH of the mucilage (6.82 ± 0.13) indicated that it might be non-irritant to the buccal cavity. The mucilage was found to be free from microbes. The release of drug was by Fickian diffusion. The in vivo buccal tablet acceptance was 80%. No significant difference between the diastolic blood pressure of standard and Aster tablets treated volunteer group was recorded. Conclusion: The mucilage was found to be non-toxic on A-431 and Vero cell lines. It was insoluble but swellable in cold and hot water. The results indicate that mucilage can form a three-dimensional network. The pH of the mucilage (6.82 ± 0.13) indicated that it might be non-irritant to the buccal cavity. The mucilage was found to be free from microbes. The release of drug was by Fickian diffusion. The in vivo buccal tablet acceptance was 80%. No significant difference between the diastolic blood pressure of standard and Aster tablets treated volunteer group was recorded. Other: However, to prove the potency of the polymer, in vivo bioavailability studies in human volunteers are needed along with chronic toxicity studies in suitable animal models.


2017 ◽  
Vol 5 (2) ◽  
pp. 1
Author(s):  
Mulyati Mulyati ◽  
Suryati Suryati ◽  
Irfani Baga

The study aims to isolate, characterize, and examine probiotic bacteria's inhibitory ability against Vibrio harveyi bacteria, both in-vitro and in vivo. Methods used in the study consist of 1) An Isolation of Candidate Probiotic Bacteria, 2) An Antagonistic Test of Candidate Probiotic Bacteria in vitro, 3) An Identification of Bacteria, 4) A Pathogenicity Test of Candidate Probiotic Bacteria, 5) An Antagonistic Test of Candidate Probiotic Bacteria against V. harveyi in vivo. According to the isolation of candidate probiotic bacteria, there are 18 isolated candidate probiotic. After being tested for its inhibitory ability in vitro, there are 8 isolates with zone of inhibition as follows: isolate MM 7 from intestine (22 mm), isolate MM 6 from intestine (12 mm), isolate MM 10 from sea water (10 mm), isolate MM 5 from intestine (9 mm), isolate MM 4 from intestine (8 mm), isolate MM 3 from intestine (7 mm), isolate MM 2.2 from intestine (7 mm), isolate MM 2.1 from intestine (7 mm). Eight genera of the candidate probiotic bacteria is derived from Portunid crab, they are Staphylococcus, Streptococcus, bacillus, vibrio, Alcaligenes, Lactobacillus, micrococcus. Before proceeding the V. harveyi bacterial challenge test in vivo, three potential isolates consisting of MM6, MM7 and MM10 as the probiotic bacteria are pathogenicity-tested against V. harveyi. The survival rate of Portunid crab on pathogenicity test using MM6, MM7 and MM10 generates 91.11-100%, while the control generates 100% survival rate. Variance analysis result through post-hoc Tukey's Honest Significant Difference (HSD) test at 95% confidence interval indicates that isolate MM7 and MM10 are significantly able to increase hatchling Portunid crab's survival rate.


Materials ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1670 ◽  
Author(s):  
Wölfle-Roos JV ◽  
Katmer Amet B ◽  
Fiedler J ◽  
Michels H ◽  
Kappelt G ◽  
...  

Background: Uncemented implants are still associated with several major challenges, especially with regard to their manufacturing and their osseointegration. In this study, a novel manufacturing technique—an optimized form of precision casting—and a novel surface modification to promote osseointegration—calcium and phosphorus ion implantation into the implant surface—were tested in vivo. Methods: Cylindrical Ti6Al4V implants were inserted bilaterally into the tibia of 110 rats. We compared two generations of cast Ti6Al4V implants (CAST 1st GEN, n = 22, and CAST 2nd GEN, n = 22) as well as cast 2nd GEN Ti6Al4V implants with calcium (CAST + CA, n = 22) and phosphorus (CAST + P, n = 22) ion implantation to standard machined Ti6Al4V implants (control, n = 22). After 4 and 12 weeks, maximal pull-out force and bone-to-implant contact rate (BIC) were measured and compared between all five groups. Results: There was no significant difference between all five groups after 4 weeks or 12 weeks with regard to pull-out force (p > 0.05, Kruskal Wallis test). Histomorphometric analysis showed no significant difference of BIC after 4 weeks (p > 0.05, Kruskal–Wallis test), whereas there was a trend towards a higher BIC in the CAST + P group (54.8% ± 15.2%), especially compared to the control group (38.6% ± 12.8%) after 12 weeks (p = 0.053, Kruskal–Wallis test). Conclusion: In this study, we found no indication of inferiority of Ti6Al4V implants cast with the optimized centrifugal precision casting technique of the second generation compared to standard Ti6Al4V implants. As the employed manufacturing process holds considerable economic potential, mainly due to a significantly decreased material demand per implant by casting near net-shape instead of milling away most of the starting ingot, its application in manufacturing uncemented implants seems promising. However, no significant advantages of calcium or phosphorus ion implantation could be observed in this study. Due to the promising results of ion implantation in previous in vitro and in vivo studies, further in vivo studies with different ion implantation conditions should be considered.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Alan Feiveson ◽  
Kerry George ◽  
Mark Shavers ◽  
Maria Moreno-Villanueva ◽  
Ye Zhang ◽  
...  

AbstractSpace radiation consists of energetic protons and other heavier ions. During the International Space Station program, chromosome aberrations in lymphocytes of astronauts have been analyzed to estimate received biological doses of space radiation. More specifically, pre-flight blood samples were exposed ex vivo to varying doses of gamma rays, while post-flight blood samples were collected shortly and several months after landing. Here, in a study of 43 crew-missions, we investigated whether individual radiosensitivity, as determined by the ex vivo dose–response of the pre-flight chromosome aberration rate (CAR), contributes to the prediction of the post-flight CAR incurred from the radiation exposure during missions. Random-effects Poisson regression was used to estimate subject-specific radiosensitivities from the preflight dose–response data, which were in turn used to predict post-flight CAR and subject-specific relative biological effectiveness (RBEs) between space radiation and gamma radiation. Covariates age, gender were also considered. Results indicate that there is predictive value in background CAR as well as radiosensitivity determined preflight for explaining individual differences in post-flight CAR over and above that which could be explained by BFO dose alone. The in vivo RBE for space radiation was estimated to be approximately 3 relative to the ex vivo dose response to gamma irradiation. In addition, pre-flight radiosensitivity tended to be higher for individuals having a higher background CAR, suggesting that individuals with greater radiosensitivity can be more sensitive to other environmental stressors encountered in daily life. We also noted that both background CAR and radiosensitivity tend to increase with age, although both are highly variable. Finally, we observed no significant difference between the observed CAR shortly after mission and at > 6 months post-mission.


2021 ◽  
Vol 45 (1) ◽  
Author(s):  
Joseph Oghenewogaga Owheruo ◽  
Timilehin David Oluwajuyitan ◽  
Beatrice Olawunmi Ifesan ◽  
Matthew Kolawole Bolade

Abstract Background The study aimed at evaluating the in-vivo nutritional qualities of extruded breakfast meal produced from flour blends of malted finger millet and watermelon seed. Results The proximate compositions of the flour blends revealed that there was progressive increase in protein (12.83–15.14) %, with increase in the watermelon substitution. The protein quality evaluation of the extrudate showed that the protein efficiency ratio ranged from 0.64 to 89.75, while the biological values were between (87.82–89.75)%. The relative organs weight of rats fed with extruded breakfast meal showed that, the weights of the kidney and liver of rats fed with extruded breakfast meal were significantly lower compared with rats fed with goldenmorn. The hematological indices showed that the packed cell volume and the red blood cell counts of rats fed with the formulated diets were significantly lower compared with those fed  with goldenmorn but significantly higher than rats fed with basal. Meanwhile, the values of the white blood cells count for the formulated diet shows no significant difference compared with rats fed with goldenmorn. Conclusions Evidently, the growth performance of the rats fed with the extruded breakfast meal revealed that the formulated diets promote growth status of the animals with relatively low effect on organs of experimental rat used in this study. Hence, formulated diet may serve as alternative to expensive commercial breakfast meal.


Sign in / Sign up

Export Citation Format

Share Document