scholarly journals Oxygen Inhibition of Surface Composites and Its Correlation with Degree of Conversion and Color Stability

2021 ◽  
Vol 32 (1) ◽  
pp. 91-97
Author(s):  
Marcela Gonçalves Borges ◽  
Gisele Rodrigues Silva ◽  
Fernanda Teodoro Neves ◽  
Carlos José Soares ◽  
André Luís Faria-e-Silva ◽  
...  

Abstract This study investigated the effects of oxygen inhibition and finishing/polishing procedures on the composite resin properties. One bulk-fill and two conventional composite resins (nanoparticle and microhybrid) were evaluated. Specimens were prepared using 4 surface treatments: control, no treatment; Gly, oxygen inhibition with glycerin; FP, finishing and polishing; Gly + FP, glycerin followed by finishing and polishing. The degree of conversion (DC) was measured using Fourier Transformed Infrared Spectroscopy (FTIR) immediately and after 15 days (n=5). Color stability (ΔEab, and ΔE00) and opacity were evaluated using a spectrophotometer after 15 days of immersion in coffee, using the CIELAB system (n=5). Data were analyzed by two-way ANOVA and Tukey tests (α=0.05) and opacity by two-way repeated-measures ANOVA. Glycerin usage increased significantly the DC however had no influence on the ΔEab, ΔE00 and, opacity values. Finishing and polishing reduced ΔEab and ΔE00 values, regardless of composite resins. Microhybrid showed higher opacity, followed by the nanoparticle and bulk fill, regardless of surface treatment. Post-polymerization polishing procedures resulted in lower conversion than using an oxygen inhibitor agent (Gly condition), but similar staining caused by coffee.

2014 ◽  
Vol 43 (5) ◽  
pp. 338-342
Author(s):  
Ana Luísa Botta Martins de OLIVEIRA ◽  
Camila Cruz LORENZETTI ◽  
Patrícia Petromilli Nordi Sasso GARCIA ◽  
Elisa Maria Aparecida GIRO

OBJECTIVE: The purpose of this study was to evaluate the effect of finishing and polishing on color stability of a nanofilled composite resin (Filtek Z350 XT) according to different immersion media.MATERIAL AND METHOD: Composite disks (10 mm diameter, 2 mm thickness) were prepared for each group (n = 6) using a stainless steel mold. The groups were divided according to the presence or absence of finishing and polishing procedure and immersion media (artificial saliva, artificial juice- KAPO(r) Coca-Cola(r)flavors: pineapple, orange, strawberry and grape). The finishing and polishing procedures were performed using Super -Snap(r) disks. The specimens were stored in artificial saliva for 24 hours (baseline) and were analyzed using a color spectrophotometer by CIELab system. Then, they were immersed in different media for 5 minutes, 3 times a day, every 4 hours during 60 days. They were stored in artificial saliva at 37 ± 1°C during the immersion intervals. After this time, new measure of color was performed. The data were analyzed using Kruskall-Wallis test and Mann- Whitney test. The significance level was 5%.RESULT: The results showed that the finishing/polishing not significantly influence the color stability of resin composite (p > 0.05). There was no statistically significant difference in the color stability of the studied resin after immersion in different media (p > 0.05).CONCLUSION: The finishing and polishing procedures and the immersion media did not have influence on color stability of nanofilled resin Filtek Z350 XT.


2019 ◽  
Vol 22 (1) ◽  
pp. Process
Author(s):  
Rodrigo Máximo Araújo ◽  
Elisangela Costa Lemes ◽  
Rubens Ferri Pachito ◽  
Fernanda Alves Feitosa

Objective: This study compared different composites for color stability after exposure to at home and in-office bleaching gels. Material and Methods: Composite resin specimens (6mm diameterx2mm thickness) were manufactured according to the following groups (n=20): RC- Conventional; BF-Bulk Fill; RF-Flow; BFF-Bulk-Fill Flow. The surfaces were stained with coffee solution for 36hrs. A spectrophotometer was used to record the initial color (L*a*b*). Half of the specimens from each group underwent bleaching with 35% hydrogen peroxide (in-office) in three 45-minute applications. New color measurements were performed after 7, 14 and 21 days. The other half of the specimens underwent bleaching with 22% carbamide peroxide (at home) in 14 1-hour applications. Further color measurements were performed after 7 and 14 hours. For comparison between the color coordinates in different periods, ANOVA for repeated measures was applied (α=5%). The color variation (ΔE) was calculated for each group. Results: For in-office bleaching, there were no significant differences between the periods b* coordinate of the RF group, and for L* and b* coordinates of the BFF group. For at home bleaching the groups BF and BFF showed no differences for the L* coordinate. For the other coordinates, there was difference between the initial periods and after 14 days. The ΔE variation presented higher values for the at home bleaching groups. For both whiteners the bulk-fill resins presented the greatest color variations. Conclusions: Bulk Fill resins do not guarantee greater color stability than the other composite resins tested, including conventional flow resin. The conventional composite resin showed the lower ΔE.


2021 ◽  
Vol 6 (1) ◽  
pp. 85
Author(s):  
Rahmi Khairani Aulia

ABSTRACT:Composite resins are currently the most popular restorative material in dentistry. This is due to good aesthetics and maximum conservation ability. Behind these advantages, there are disbenefits of composite resin materials, such as polymerization shrinkage, which can lead to restoration failure. Various attempts have been investigated to reduce the shrinkage incidence of composite resins, one of which is the technique of placing the restorative material into the cavity. The restoration filling technique is recognized as a significant factor in shrinkage stress. By using a special filling technique, the polymerization shrinkage damage stress can be reduced. There are several techniques in performing composite resin fillings, including bulk and incremental techniques. These techniques have their respective advantages and disadvantages. The aim of this literature review was to compare the physical properties of composite resin restorations with bulk filling and incremental techniques. Physical properties that being studied include polymerization shrinkage, stress shrinkage, degree of conversion, bonding strength, water resorption, color stability, and temperature increase. Comparing the two techniques, composite resin with incremental filling technique has superior physical properties compared to bulk technique. From the comparison of the two techniques, the composite resin with incremental filling technique has superior physical properties compared to the bulk technique, especially in higher conversion which causes lower shrinkage stress. This situation makes the incremental technique provide better bond strength, water resorption, color stability, and lower temperature rise.Keywords: Bulk, Composite Resin, Incremental,  Physical Properties, Restoration, Restoration Technique


2011 ◽  
Vol 22 (5) ◽  
pp. 365-368 ◽  
Author(s):  
Fernanda Valentini ◽  
Simone Gomes Dias de Oliveira ◽  
Guilherme Zdradk Guimarães ◽  
Renata Pereira de Sousa Barbosa ◽  
Rafael Ratto de Moraes

This study investigated the effect of sealant application on the color stability of composite resin restorations. Cavities in bovine incisors were restored with composite resin (Opallis; FGM) and the teeth were assigned to 4 groups (n=10). A sealant (Fill Glaze; Vigodent) was applied over the restorations of 2 groups. Baseline color measurements based on the CIEL*a*b* system were carried out using a spectrophotometer. Half the number of specimens was immersed in distilled water, and half was immersed in coffee 4 h/day. Color measurements were repeated after 1 h, 24 h, 7 days and 3 months. Data for each immersion solution were separately subjected to a two-way repeated measures ANOVA and Tukey’s test (α=0.05). For the group without sealant immersed in water, no significant differences were observed among the periods (p≥0.138), but the color was different compared with baseline (p<0.001). For the group with sealant application, the periods baseline, 1 h and 3 months presented similar results (p≥0.924). For groups immersed in coffee, when the sealant was not used, no significant differences were detected between the baseline and the periods 1 h and 24 h (p≥0.499), but the color changed significantly thereafter (p≤0.003). In the group with sealant, significant differences were detected for all periods compared with each other (p<0.001). In conclusion, application of sealant dramatically increased the staining of the restorations exposed to coffee.


2014 ◽  
Vol 17 (2) ◽  
pp. 27
Author(s):  
Thays Regina Costa ◽  
Lucielle Cristina Cecchin ◽  
Alessandro Dourado Loguercio ◽  
Alessandra Reis

<p><strong>Objective:</strong> The durability of bonded interface between silorane (SIL) and methacrylate-based (MET) composite resins wasn’t investigated yet. The purpose was to evaluate the repair strength (RS) and nanoleakage of the SIL repair using silorane- or methacrylate-based materials immediately [IM] or after 6 months of water storage [6M]. <strong>Materials and Methods:</strong> fifteen resin blocks (Filtek P90, 3MESPE) were polished, sandblasted with 50-µm aluminum oxide sandblasting and cleaned with 37% phosphoric acid. Then the specimens were divided into three groups: SIL-SIL (adhesive and composite resin); SIL-MET (silorane adhesive and methacrylate based composite) and MET-MET (methacrylate-based adhesive and composite resin) were used for the repair. Composite-composite bonded sticks (0.9 mm<sup>2</sup>) were sectioned and divided to be tested in tension (1.0 mm/min) IM or 6M. Two sticks from each tooth, at each time, were immersed in a 50% silver nitrate solution and evaluated by SEM. Data were analyzed by two-way repeated measures ANOVA and Tukey´s tests. <strong>Results:</strong> The RS of the SIL was not dependent upon the adhesive and composite used for the repair. A significant reduction of the RS was observed for all groups after 6M. <strong>Conclusions:</strong> Both materials can be used for the repair of the silorane composite, despite degradation occur after 6M.</p>


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Tugba Bezgin ◽  
Ceren Cimen ◽  
Nurhan Ozalp

Unreacted monomers eluted from resin-based restorative materials have been considered a reason of local and systemic adverse reactions. This study was designed to determine the effect of finishing and polishing procedures on the elution of Bis-GMA, TEGDMA, UDMA, and HEMA monomers from compomer and bulk-fill composite resins. Bulk-fill composite (3M ESPE GmbH, Seefeld, Germany) and compomer (Dentsply DeTrey GmbH, Konstanz, Germany) specimens with 3 × 4   mm diameters were prepared. The specimens were randomly divided into two groups, and finishing-polishing procedures were applied only to the experimental groups. Release of residual monomers was analyzed by using High-Performance Liquid Chromatography (HPLC) after 24, 48, and 72 hours. Repeated measures ANOVA and Tukey post hoc tests were used for comparisons. Finishing and polishing procedures had a significant effect on reducing the quantity of UDMA release in the Filtek™ Bulk Fill composite and Bis-GMA, HEMA, and TEGDMA in the Dyract XP compomer ( p < 0.05 ). The restorative materials investigated here are not chemically stable after polymerization, and concentrations of eluted monomers may reach critical toxicity levels even after one restoration placement. Finishing and polishing procedures are mandatory to reduce residual monomers.


2019 ◽  
Vol 45 (4) ◽  
pp. 377-386 ◽  
Author(s):  
IO Cardoso ◽  
AC Machado ◽  
DNR Teixeira ◽  
FC Basílio ◽  
A Marletta ◽  
...  

Clinical Relevance Irradiance may decrease as the light-emitting diode (LED) is discharged. Therefore, the LED must be charged carefully to prevent the possibility of influencing the chemical, mechanical, and physical properties of composite resin. SUMMARY The aim of this study was to evaluate the influence of different light-emitting diode (LED) curing units and battery levels on the chemical, mechanical, and physical properties of composite resins. The irradiance for each cycle from full to completely discharged battery level was evaluated, for five different new cordless LED units: Optilight Color (Gnatus), Bluephase (Ivoclar), Valo (Ultradent), Radii Plus (SDI), and Radii Xpert (SDI). After the irradiance evaluation, composite resin specimens were prepared and light cured, while varying the battery level for each LED unit: high level (HL, 100%), medium level (ML, 50%), and low level (LL, 10%). The degree of conversion, diametral tensile strength, sorption, and solubility were also evaluated. Data were checked for homoscedasticity and submitted to two-way and three-way analysis of variance, depending on the test performed, followed by the Tukey test with a significance level of 95%. A negative correlation was found between irradiance and cycles of light curing, which was checked by the Pearson correlation test. Valo and Radii Xpert were not influenced by the battery level in any test performed. However, different battery levels for some LED units can influence the degree of conversion, diametral tensile strength, sorption, and solubility of composite resins.


2007 ◽  
Vol 8 (1) ◽  
pp. 27-35 ◽  
Author(s):  
Nuray Attar

Abstract Aims The aims of this study were to evaluate the effect of various finishing and polishing procedures on the surface roughness of six different composite resin materials (Artemis Enamel, TPH Spectrum, Filtek A–110, Filtek Supreme Enamel, Solitaire 2, and Filtek P–60) as well as to evaluate the effectiveness of the surface sealant application (BisCover) on the surface roughness after finishing and polishing procedures of tested composites. Methods and Materials Specimens (n=168) measuring 5 mm in diameter x 2 mm in thickness were fabricated in a plexiglass well covered with a Mylar strip using six composite resins. A control group of seven specimens of each material received no polishing after being cured under the Mylar strip. Twenty-one specimens for each composite were randomly divided among three finishing and polishing groups (n=7). Each group was polished using a different system: Carbide bur/Sof-Lex disc, Carbide bur/Enhance disc with polishing paste, and Carbide bur/Edenta composite finishing kit. The average surface roughness (Ra, ìm) of the control and treated specimens were measured with the Mitutoyo Surftest–402 Surface Roughness tester. After a surface sealant (BisCover) was applied to all treated specimens, according to manufacturer's instructions, the average roughness (Ra) was measured again. Results were statistically analyzed using analysis of variance (ANOVA) and the post-hoc Scheffe's test at a p<0.05 significance level. Results Significant differences were found for the surface roughness (p<0.05) with interaction among composite resins and the finishing systems used (p<0.05). Enhance/Biscover finishing and polishing procedure surface was not significantly different from the Mylar strip surface groups (p>0.05). The Mylar strip group was not significantly different from the Sof-Lex/BisCover and Edenta/BisCover groups. The ranking of mean Ra values by materials was as follows: Filtek Supreme Enamel < Filtek A110 < TPH Spectrum < Artemis <Filtek P–60 < Solitaire 2. The ranking of mean Ra values by polishing systems was as follows: Enhance/BisCover < Mylar Strip < Sof-Lex/BisCover < Edenta/BisCover < Sof-Lex < Enhance < Edenta. Conclusion Smoother surfaces were recorded for the Enhance/BisCover and the Mylar strip-formed surface groups. The composite finishing kit Edenta significantly increased the Ra for all tested composites (p<0.05). But after finishing with Edenta, the use of a surface sealant (BisCover) significantly improved the surface smoothness of all tested composites (p<0.05). Use of BisCover surface sealant on anterior and posterior resin composite restorations after finishing and polishing procedures is recommended. Citation Attar N. The Effect of Finishing and Polishing Procedures on the Surface Roughness of Composite Resin Materials. J Contemp Dent Pract 2007 January;(8)1:027-035.


2016 ◽  
Vol 2016 ◽  
pp. 1-5 ◽  
Author(s):  
Sayna Shamszadeh ◽  
Seyedeh Mahsa Sheikh-Al-Eslamian ◽  
Elham Hasani ◽  
Ahmad Najafi Abrandabadi ◽  
Narges Panahandeh

We aimed to evaluate the color stability of bulk-fill and conventional composite resin with respect to thickness and storage media. Twenty specimens of a conventional composite resin (6 mm diameter and 2 mm thick) and 40 specimens of the bulk-fill Tetric EvoCeram composite resin at two different thicknesses (6 mm diameter and 2 mm thick or 4 mm thick,n=20) were prepared. The specimens were stored in distilled water during the study period (28 d). Half of the specimens were remained in distilled water and the other half were immersed in coffee solution 20 min/d and kept in distilled water between the cycles. Color changes (ΔE) were measured using the CIEL⁎a⁎b⁎color space and a digital imaging system at 1, 7, 14, and 28 days of storage. Data were analyzed using Two-way ANOVA and Tukey’s HSD post hoc test (P<0.05). Composite resins showed significant increase in color changes by time (bulk-fill > conventional;P<0.001). Coffee exhibited significantly more staining susceptibility than that of distilled water (P<0.001). There was greater color changes with increasing the increment thickness, which was significant at 14 (P<0.001) and 28 d (P<0.01). Color change of bulk-fill composite resin was greater than that of the conventional one after coffee staining and is also a function of increment thicknesses.


2016 ◽  
Vol 41 (4) ◽  
pp. 409-416 ◽  
Author(s):  
AG Pereira ◽  
LHA Raposo ◽  
DNR Teixeira ◽  
RCQ Gonzaga ◽  
IO Cardoso ◽  
...  

SUMMARY The properties of composite resins can be influenced by light activation, depending primarily on the performance of the curing unit. The aim of this study was to evaluate how different battery levels of a cordless light-emitting diode (LED) unit influence the properties of a nanofilled composite resin. First, the battery voltage and light intensity of the cordless LED unit were individually checked for all light-curing cycles. Then, composite resin discs were prepared and light-cured at different battery levels: high level (HL, 100%), medium level (ML, 50%), and low level (LL, 10%). The degree of conversion, diametral tensile strength, sorption, and solubility of the specimens were tested. Data were checked for homoscedasticity and submitted to one-way analysis of variance followed by Tukey honestly significant difference and Pearson correlation tests (p&lt;0.05). The battery voltage and light intensity varied significantly among the groups (p&lt;0.001). The LL group presented a lower degree of conversion than the HL and ML groups (p&lt;0.001), which shower similar results (p=0.182). Lower diametral tensile strength was also verified for the LL group when compared with the HL and ML groups (p&lt;0.001), which presented no difference (p=0.052). Positive correlation was observed between the light intensity and the parameters studied, with the exception of sorption and solubility (p&lt;0.001). The ML and LL groups showed higher sorption than the HL group (p &lt;0.001), but no difference was verified between the first two groups (p=0.535). No significant differences were found for solubility between the ML and LL groups (p=0.104), but the HL group presented lower values (p&lt;0.001). The different battery levels of the cordless LED curing unit influenced all the properties of the nanofilled composite resin evaluated.


Sign in / Sign up

Export Citation Format

Share Document