scholarly journals Method for predicting voltages in a three-phase overhead line with a ground wire in conditions of reduced quality of electric energy

Author(s):  
Georgiy Bolshanin ◽  
◽  
Mihail Shevchenko ◽  
2021 ◽  
Vol 101 ◽  
pp. 02012
Author(s):  
Igor Naumov ◽  
Sergey Podyachikh ◽  
Dmitriy Ivanov

Violation of the symmetrical mode of operation of the electric network causes a deterioration in the quality of electric energy and significantly reduces the reliability of the functioning of electrical equipment and elements of the electric network. A mathematical model of an electrical network with a grounded neutral is proposed аnd a software package that allows us to evaluate the level of voltage asymmetry of a three-phase system depending on the changing unbalanced load was created. The simulation and calculation of the studied parameters for various combinations of loads and the technical means of balancing the operating mode of the electric network (the balancing device – BD) is carried out. Programs for the Matlab graphic editor are compiled and diagrams of changes in electricity quality indicators are constructed. A numerical analysis is carried out and recommendations are given to determine the most appropriate place for connecting the BD in the electrical network to improve the quality of electricity based on the calculation made.


2015 ◽  
Vol 9 (1) ◽  
pp. 553-559
Author(s):  
HU Xin-xin ◽  
Chen Chun-lan

In order to optimize the electric energy quality of HVDC access point, a modular multilevel selective harmonic elimination pulse-width modulation (MSHE-PWM) method is proposed. On the basis of keeping the minimum action frequency of the power device, MSHE-PWM method can meet the requirement for accurately eliminating low-order harmonics in the output PWM waveform. Firstly, establish the basic mathematical model of MMC topology and point out the voltage balance control principle of single modules; then, analyze offline gaining principle and realization way of MSHEPWM switching angle; finally, verify MSHE-PWM control performance on the basis of MMC reactive power compensation experimental prototype. The experimental result shows that the proposed MSHE-PWM method can meet such performance indexes as low switching frequency and no lower-order harmonics, and has verified the feasibility and effectiveness thereof for optimizing the electric energy quality of HVDC access point.


2014 ◽  
Vol 687-691 ◽  
pp. 3110-3115
Author(s):  
Gu Li ◽  
Zi Ming Fu ◽  
Jie Feng Yan ◽  
Bing Wen Li ◽  
Zhi Rong Cen

This paper analyzes and studies the definition of the voltage transformer secondary load, examines the practical purposes of the measured values of the voltage transformer secondary load, and presents a variety of testing methods to analyze and compare the differences. This paper gives the test methods of the voltage transformer secondary load when the connection of the voltage transformer is the Y / Y in a three-phase three-wire power supply system, filling the blank of this type of test method in the industry. When other units within the industry carry out such work, the conclusions of this paper are available for reference, and the conclusions of this paper can be referred when drafting relevant regulations in the future.


2013 ◽  
Vol 732-733 ◽  
pp. 1261-1264
Author(s):  
Zhi Lei Yao ◽  
Lan Xiao ◽  
Jing Xu

An improved control strategy for three-phase grid-connected inverters with space vector pulse width modulation (SVPWM) is proposed. When the grid current contains harmonics, the d-and q-axes grid currents is interacted in the traditional control method, and the waveform quality of the grid current is poor. As the reference output voltage cannot directly reflect the change of the reference grid current with the traditional control strategy, the dynamic response of the grid-connected inverter is slow. In order to solve the aforementioned problems, the d-and q-axes grid currents in the decoupled components of the grid current controller are substituted by the d-and q-axes reference grid currents, respectively. The operating principles of the traditional and proposed control methods are illustrated. Experimental results show that the grid-connected inverter with the improved control strategy has high waveform quality of the grid current and fast dynamic response.


2012 ◽  
Vol 19 (1) ◽  
pp. 39-48 ◽  
Author(s):  
Jarosław Zygarlicki ◽  
Janusz Mroczka

Variable-Frequency Prony Method in the Analysis of Electrical Power QualityThe article presents a new modification of the the least squares Prony method. The so-called variable-frequency Prony method can be a useful tool for estimating parameters of sinusoidal components, which, in the analyzed signal, are characterized by time-dependent frequencies. The authors propose use of the presented method for testing the quality of electric energy. It allows observation of phenomena which, when using traditional methods, are averaged in the analysis window. The proposed modification of least squares Prony method is based on introduction and specific selection of a frequency matrix. This matrix represents frequencies of estimated components and their variability in time.


2014 ◽  
Vol 529 ◽  
pp. 501-505
Author(s):  
Chi Zhang ◽  
Ming Zhi He

With the continuous development of power electronic technology, the advantages of thyristor power regulator circuit gradually get more and more applications. It improves the quality of power supply, makes the equipment efficiency and power factor higher and so saves a lot of electricity. Through the calculation of the primary current when thyristor turns off in three-phase power regulator circuit with transformer load, the impact of the thyristors turn-off order on the transformer primary current voltage-second product is analysised, and through simulation the exactness is verified.


2021 ◽  
Vol 2 (2) ◽  
pp. 29-35
Author(s):  
Dmitry A. Sorokin ◽  
◽  
Sergey I. Volskiy ◽  
Jaroslav Dragoun ◽  
◽  
...  

The paper suggests a control system of a three-phase power factor corrector. The study of the control system operation is carried out and the expressions for calculating the permissible values of error amplifier factors are obtained. The influence of the error amplifier parameters on phase current quality is investigated. The dependence of total harmonic distortion input current on a combination of error amplifier parameters is obtained at a given value of power factor. The conditions under which the total harmonic distortion input current has the minimum value are found out. This article is of interest to power electronics engineers, who are aimed at developing a three-phase power factor corrector.