Design of Surface Water Pollution Monitoring and Discovery System using Internet of Things

2020 ◽  
Vol 52 (2) ◽  
pp. 05-07
Author(s):  
Novel Pokrovskii

Water is one of the essential necessities and vital for supporting the personal satisfaction. Attributable to expanding pattern in global advancement, the nature of water is persistently flagging. Water contamination has been an expanding issue in the course of the most recent couple of years. Lakes and streams would those key wellsprings about drinking water, which stunningly depend on upon water individual fulfilment. For this reason, we recommend an IoT based water quality framework fit for estimating the nature of water. The proposed arrangement depends on WHO characterized water quality measurements. An installed model is created to proof the water superiority boundaries from the water tests gathered from different sources over the investigation zone. The goal of this water quality checking framework utilizing web of things is to locate the nature of the water for example how the pH content changes and sending message to the comparing specialists. Further we broaden this venture by sending the sensor information to cloud for worldwide checking of water quality. The handled information can be distantly observed and water stream can be controlled utilizing our created programming arrangement containing versatile application and a dashboard. Notwithstanding water superiority checking and manage framework, the prescient investigation of the gathered information is performed. AI calculations are applied for arrangement of water superiority and the test results demonstrate that profound neural system beats every other calculation.

TAPPI Journal ◽  
2014 ◽  
Vol 13 (9) ◽  
pp. 51-60
Author(s):  
DENNIS VOSS ◽  
HANS-JOACHIM PUTZ ◽  
SAMUEL SCHABEL

The need for deinking mills to reduce their fresh water consumption has resulted in higher loads of various contaminants in the process water. Lower recovered paper quality also leads to higher contamination levels in the mills. This higher load has an influence on achievable target brightness. The objective of the work was to determine and explain the main reasons for relatively poor deinked pulp quality or poor deinking potential based on the influence of recovered paper composition and process water quality. The process water parameters significantly affect the deinking potential of recovered paper. The test results showed the negative effects of increased water hardness. For standard recovered paper mixtures, flotation selectivity is higher with increasing flotation pH-value. Good results were realized for standard recovered paper with low hardness, low surface tension, and high pH-value. The results for recovered paper containing flexo newsprint could be slightly improved with low hardness, low surface tension, and low pH-value. The results of the test program using design of experiments showed interacting effects of pH-value and surface tension on luminosity and flotation selectivity.


2018 ◽  
Vol 59 ◽  
pp. 00025
Author(s):  
Agnieszka Szuster – Janiaczyk ◽  
Rafał Brodziak ◽  
Jędrzej Bylka

One of the processes that significantly determines the quality of water to consumers is the process of mixing water from different sources in the water mains. Put to the network two or more chemically and biologically stable waters may result in the formation of water that will be deprived of these features. This article presents the german guidelines for analysing water quality for mixing waters from different sources, in various proportions. Then performed an analysis of utility the mathematical models,including quality criteria, for use in network control. An IT tool has been developed to manage selected water quality processes using mathematical modeling. The basis for implementing the tool was a network model created in Epanet integrated with the Matlab.


2021 ◽  
Vol 13 (13) ◽  
pp. 7513
Author(s):  
Joshua Lozano ◽  
Joonghyeok Heo ◽  
Mijin Seo

The purpose of this study was to evaluate the public water contamination levels of Winkler County, in West Texas. With water scarcity becoming more prevalent in arid climates like West Texas, it is important to ensure the water quality in these areas. The Dockum and Pecos Valley aquifers were analyzed for inorganic pollutants that could inhibit the water. The parameters such as copper, lead, arsenic, nitrate, chloride, and chromium level reports were provided from 1972 to 2018 to analyze and compare to other studies such as the ones conducted in the Midland/Odessa area. The results were compared to the Environmental Protection Agency (EPA) safety standards, and conclusions were made for the safety consumption of water within the county. We found that inorganic pollutants resulted mainly from the mobilization of the contaminant from anthropogenic activities such as chemical fertilizers, oil and gas developments. This research provides important information for inorganic pollutants in the sinkhole region of Winkler County and contributes to understanding the response to the aquifers. The significance of water quality in West Texas is now more important than ever to ensure that everyone has clean drinking water.


2021 ◽  
Vol 193 (8) ◽  
Author(s):  
Desmond Tichaona Mugadza ◽  
Sibusisiwe Isabel Nduku ◽  
Edlyn Gweme ◽  
Sherpherd Manhokwe ◽  
Patience Marume ◽  
...  

2014 ◽  
Vol 73 (3) ◽  
pp. 1091-1101 ◽  
Author(s):  
Zanfang Jin ◽  
Lingxiao Chen ◽  
Feili Li ◽  
Zhiyan Pan ◽  
Mantong Jin

2021 ◽  
Vol 27 (1) ◽  
Author(s):  
MANOJ KUMAR SHUKLA

Present study points out the impact of Lockdown on the health of the Yamuna river at Delhi stretch by comparing prelockdown and Post-lockdown period by studying the reports of pollution monitoring agencies. Delhi segment of the Yamuna is highly polluted, where alongwith domestic sewage a huge quantity of industrial waste is being discharged continuously without proper treatment. Pre lockdown (March 2020) water quality parameters at three sampling stations named as Palla, Nizammuddin Bridge and Okhla barrage U/s in Delhi were, pH were 8.7, 7.3 and 7.2, DO were 17.1 mg/L, not detected in later two sites, BOD were 7.9 mg/L, 57 mg/L and 27 mg/L and COD were 28 mg/L, 90 mg/L and 95 mg/L respectively and postlockdown period (April 2020) the pH was 7.8, 7.2 and 7.1, DO was 8.3 mg/L, 2.4 mg/L and 1.2 mg/L BOD was 2 mg/L, 5.6 mg/ L and 6.1 mg/L and COD were 6 mg/L, 16 mg/L and 18 mg/L respectively. The study of these parameters at three sampling stations reveals that the lack of industrial pollutants discharging due to nationwide lockdown for COVID-19 pandemic had positive effect on water quality of this river. Water quality could be maintained by planned establishment of industries and setup of ETP with without gap between generation and treatment.


Author(s):  
Ni Luh Putu Mega Priantari ◽  
I Wayan Budiarsa Suyasa ◽  
I Wayan Windia

Many activities and the continuous disposal of waste water has resulted water pollution in Tukad Rangda. Tukad Rangda's water quality over the last five years (2012-2016) indicated experiencing contamination with decreasing water quality. The condition indicates the need of serious effort to maintain the water quality of Tukad Rangda. The purpose of this research is to know the perception and behavior of head of household and businesses in conducting waste water management that potentially causing Tukad Rangda water contamination, determining water quality and water quality status based on the Pollution Index, and determining appropriate alternative strategies to control water pollution in Tukad Rangda. Sample was collected by purposive sampling. Water samples was taken at three point: on the upstream, middle, and downstream of Tukad Rangda. Samples are analyzed in situ and in laboratory. Determination of perception and community behavior based on questionnaires and interviews to households and businesses. The data obtained were analyzed by force-field analysis to determine alternative strategy of Tukad Rangda water contamination control. The results of perception analysis of households and businesses on waste water management that has the potential to cause Tukad Rangda water contamination shows well-categorized results. However, for the behavior of head of households and businesses on waste water management that potentially causing Tukad Rangda water pollution, each of them showing results that can be categorized as quite good and less good respectively. Water quality of Tukad Rangda at upstream, middle, and downstream areas have exceeded the water quality standard class II in accordance with the Bali Governor Regulations No. 16 year 2016 for these parameters: BOD, COD, phosphate, and lead. Water quality status of Tukad Rangda based on Method of Pollution Index at upstream, middle, and downstream classified slightly contaminated. Based on force-field analysis, the alternative strategy obtained is increasing the insight and understanding about waste water management to the community, water waste management regulation at household scale, coaching, supervision, and law enforcement against businesses violating the applicable regulations, providing waste water treatment facilities, as well as the development of Tukad Rangda as water tourism area through the involvement of community participation.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Dibo Hou ◽  
Shu Liu ◽  
Jian Zhang ◽  
Fang Chen ◽  
Pingjie Huang ◽  
...  

This study proposes a probabilistic principal component analysis- (PPCA-) based method for online monitoring of water-quality contaminant events by UV-Vis (ultraviolet-visible) spectroscopy. The purpose of this method is to achieve fast and sound protection against accidental and intentional contaminate injection into the water distribution system. The method is achieved first by properly imposing a sliding window onto simultaneously updated online monitoring data collected by the automated spectrometer. The PPCA algorithm is then executed to simplify the large amount of spectrum data while maintaining the necessary spectral information to the largest extent. Finally, a monitoring chart extensively employed in fault diagnosis field methods is used here to search for potential anomaly events and to determine whether the current water-quality is normal or abnormal. A small-scale water-pipe distribution network is tested to detect water contamination events. The tests demonstrate that the PPCA-based online monitoring model can achieve satisfactory results under the ROC curve, which denotes a low false alarm rate and high probability of detecting water contamination events.


Sign in / Sign up

Export Citation Format

Share Document