scholarly journals Investigation of Human Cardiac Fiber Architecture with Multiple diffusion MRI schemes at Multi-Scales based on Simulation Data

2020 ◽  
Author(s):  
Hongbo DU ◽  
Lihui wang ◽  
Jianping HUANG

Abstract Background Diffusion tensor imaging (DTI), diffusion spectrum imaging (DSI) and Q-ball imaging (QBI) are currently three main diffusion MRI (dMRI) schemes available for non-invasive investigation of cardiac fiber architecture. Although DSI and QBI have undoubtedly greater potential to reveal complex cardiac fiber structures than DTI, it however remains unclear to which level and at which scale they provide more gain for investigating cardiac fiber structure.Method This work attends to provide a quantitative description of cardiac fiber architecture derived from different schemes at various scales. Due to the limit of the spatial resolution of clinical MRI scanner and with the absence of the ground-truth, it is difficult to give the accurate description. To deal with this issue, we simulate firstly DTI, DSI and QBI of a cardiac fiber model with the structure a priori known at different scales, and then the estimation accuracy, the diffusion metrics and the helix and transverse angles of cardiac fiber obtained by different schemes at different scales are calculated. Results The results show that although DSI and QBI can distinguish multiple fiber orientations, they are readily to generate false positive and false negative fibers which influence therefore the estimation accuracy. When there are multiple fiber orientations in one voxel, the diffusion anisotropy detected by DTI is higher than DSI and QBI, the range of helix and transverse angle decreases with increasing of the scales, and that detected by DSI is larger than DTI and QBI. Conclusion The results showed that the proposed dMRI simulator provides a valuable tool for simulating realistic DW images of whole human hearts, which can be used as the gold standard to study the fiber structures of the heart.

2019 ◽  
Vol 3 (4) ◽  
pp. 1038-1050 ◽  
Author(s):  
Céline Delettre ◽  
Arnaud Messé ◽  
Leigh-Anne Dell ◽  
Ophélie Foubet ◽  
Katja Heuer ◽  
...  

The anatomical wiring of the brain is a central focus in network neuroscience. Diffusion MRI tractography offers the unique opportunity to investigate the brain fiber architecture in vivo and noninvasively. However, its reliability is still highly debated. Here, we explored the ability of diffusion MRI tractography to match invasive anatomical tract-tracing connectivity data of the ferret brain. We also investigated the influence of several state-of-the-art tractography algorithms on this match to ground truth connectivity data. Tract-tracing connectivity data were obtained from retrograde tracer injections into the occipital, parietal, and temporal cortices of adult ferrets. We found that the relative densities of projections identified from the anatomical experiments were highly correlated with the estimates from all the studied diffusion tractography algorithms (Spearman’s rho ranging from 0.67 to 0.91), while only small, nonsignificant variations appeared across the tractography algorithms. These results are comparable to findings reported in mouse and monkey, increasing the confidence in diffusion MRI tractography results. Moreover, our results provide insights into the variations of sensitivity and specificity of the tractography algorithms, and hence into the influence of choosing one algorithm over another.


2021 ◽  
Author(s):  
Tristan K. Kuehn ◽  
Farah N. Mushtaha ◽  
Ali R. Khan ◽  
Corey A. Baron

AbstractPurposeTo introduce a method to create 3D-printed axon-mimetic phantoms with complex fibre orientations to characterize the performance of diffusion MRI models and representations in the presence of orientation dispersion.MethodsAn extension to an open source 3D printing package was created to 3D print a set of five 3D-printed axon-mimetic (3AM) phantoms with various combinations of bending and crossing fibre orientations. A two-shell diffusion MRI scan of the five phantoms in water was performed at 9.4T. Diffusion tensor imaging (DTI), diffusion kurtosis imaging (DKI), the ball and stick model, neurite orientation density and dispersion imaging (NODDI), and Bingham-NODDI were all fit to the resulting diffusion MRI data. A fiducial in each phantom was used to register a ground truth map of that phantom’s crossing angles and/or arc radius to the diffusion-weighted images. Metrics from each model and representation were compared to the ground-truth maps, and a quadratic regression model was fit to each combination of output metric and ground-truth metric.ResultsThe mean diffusivity (MD) metric defined by DTI was insensitive to crossing angle, but increased with fibre curvature. Axial diffusivity (AD) decreased sharply with increasing crossing angle. DKI’s diffusivity metrics replicated the trends seen in DTI, and its mean kurtosis (MK) metric, decreased with fibre curvature, except in regions with high crossing angles. The estimated stick volume fraction in the ball and stick model decreased with increasing fibre curvature and crossing angle. NODDI’s intra-neurite volume fraction was insensitive to crossing angle, and its orientation dispersion index (ODI) was strongly correlated to crossing angle. Bingham-NODDI’s intra-neurite volume fraction was also insensitive to crossing angle, while its primary ODI (ODIP) was also strongly correlated to crossing angle and its secondary ODI (ODIS) was insensitive to crossing angle. For both NODDI models, the volume fractions of the extra-neurite and CSF compartments had low reliability with no clear relationship to crossing angle.ConclusionsThis study demonstrates that inexpensive 3D-printed axon-mimetic phantoms can be used to investigate the effect of fibre curvature and crossings on diffusion MRI representations and models of diffusion signal. As a proof of concept, the dependence of several representations and models on fibre dispersion/crossing were investigated. As expected, Bingham-NODDI was best able to characterize planar fibre dispersion in the phantoms.


2019 ◽  
Author(s):  
Xuan Gu ◽  
Anders Eklund

PurposeSusceptibility distortions impact diffusion MRI data analysis and is typically corrected during preprocessing. Correction strategies involve three classes of methods: registration to a structural image, the use of a fieldmap, or the use of images acquired with opposing phase encoding directions. It has been demonstrated that phase encoding based methods outperform the other two classes, but unfortunately, the choice of which phase encoding based method to use is still an open question due to the absence of any systematic comparisons.MethodsIn this paper we quantitatively evaluated six popular phase encoding based methods for correcting susceptibility distortions in diffusion MRI data. We employed a framework that allows for the simulation of realistic diffusion MRI data with susceptibility distortions. We evaluated the ability for methods to correct distortions by comparing the corrected data with the ground truth. Four diffusion tensor metrics (FA, MD, eigenvalues and eigenvectors) were calculated from the corrected data and compared with the ground truth. We also validated two popular indirect metrics using both simulated data and real data. The two indirect metrics are the difference between the corrected LR and AP data, and the FA standard deviation over the corrected LR, RL, AP and PA data.ResultsWe found that DR-BUDDI and TOPUP offered the most accurate and robust correction compared to the other four methods using both direct and indirect evaluation metrics. EPIC and HySCO performed well in correcting b0 images but produced poor corrections for diffusion weighted volumes, and also they produced large errors for the four diffusion tensor metrics. We also demonstrate that the indirect metric (the difference between corrected LR and AP data) gives a different ordering of correction quality than the direct metric.ConclusionWe suggest researchers to use DR-BUDDI or TOPUP for susceptibility distortion correction. The two indirect metrics (the difference between corrected LR and AP data, and the FA standard deviation) should be interpreted together as a measure of distortion correction quality. We also suggest that indirect metrics must be interpreted cautiously when evaluating methods for correcting susceptibility distortions in diffusion MRI data.


2019 ◽  
Author(s):  
C. Delettre ◽  
A. Messé ◽  
L-A. Dell ◽  
O. Foubet ◽  
K. Heuer ◽  
...  

AbstractThe anatomical wiring of the brain is a central focus in network neuroscience. Diffusion MRI tractography offers the unique opportunity to investigate the brain fiber architecture in vivo and non invasively. However, its reliability is still highly debated. Here, we explored the ability of diffusion MRI tractography to match invasive anatomical tract-tracing connectivity data of the ferret brain. We also investigated the influence of several state-of-the-art tractography algorithms on this match to ground truth connectivity data. Tract-tracing connectivity data were obtained from retrograde tracer injections into the occipital, parietal and temporal cortices of adult ferrets. We found that the relative densities of projections identified from the anatomical experiments were highly correlated with the estimates from all the studied diffusion tractography algorithms (Spearman’s rho ranging from 0.67 to 0.91), while only small, non-significant variations appeared across the tractography algorithms. These results are comparable to findings reported in mouse and monkey, increasing the confidence in diffusion MRI tractography results. Moreover, our results provide insights into the variations of sensitivity and specificity of the tractography algorithms and hence, into the influence of choosing one algorithm over another.


2020 ◽  
Vol 77 (4) ◽  
pp. 1609-1622
Author(s):  
Franziska Mathies ◽  
Catharina Lange ◽  
Anja Mäurer ◽  
Ivayla Apostolova ◽  
Susanne Klutmann ◽  
...  

Background: Positron emission tomography (PET) of the brain with 2-[F-18]-fluoro-2-deoxy-D-glucose (FDG) is widely used for the etiological diagnosis of clinically uncertain cognitive impairment (CUCI). Acute full-blown delirium can cause reversible alterations of FDG uptake that mimic neurodegenerative disease. Objective: This study tested whether delirium in remission affects the performance of FDG PET for differentiation between neurodegenerative and non-neurodegenerative etiology of CUCI. Methods: The study included 88 patients (82.0±5.7 y) with newly detected CUCI during hospitalization in a geriatric unit. Twenty-seven (31%) of the patients were diagnosed with delirium during their current hospital stay, which, however, at time of enrollment was in remission so that delirium was not considered the primary cause of the CUCI. Cases were categorized as neurodegenerative or non-neurodegenerative etiology based on visual inspection of FDG PET. The diagnosis at clinical follow-up after ≥12 months served as ground truth to evaluate the diagnostic performance of FDG PET. Results: FDG PET was categorized as neurodegenerative in 51 (58%) of the patients. Follow-up after 16±3 months was obtained in 68 (77%) of the patients. The clinical follow-up diagnosis confirmed the FDG PET-based categorization in 60 patients (88%, 4 false negative and 4 false positive cases with respect to detection of neurodegeneration). The fraction of correct PET-based categorization did not differ between patients with delirium in remission and patients without delirium (86% versus 89%, p = 0.666). Conclusion: Brain FDG PET is useful for the etiological diagnosis of CUCI in hospitalized geriatric patients, as well as in patients with delirium in remission.


2021 ◽  
Vol 13 (10) ◽  
pp. 1955
Author(s):  
Maria Daniela Graziano ◽  
Alfredo Renga

The recognition of wakes generated by dark vessels is a tremendous and interesting challenge in the field of maritime surveillance by Synthetic Aperture Radar (SAR) images. The paper aims at assessing the detection performance in different scenarios by processing Sentinel-1 SAR images along with ground truth data. Results confirm that the Radon-based approach is an effective technique for wake-based detection of dark vessels, and they lead to a deeper understanding of the effects of different sea and wind conditions. In general, the best applicative scenario is a marine image characterized by homogeneous sea clutter; the presence of natural surface film or strong transition from low wind speed areas to more windy zones worsen the detection performance. Nonetheless, the proposed approach features dark vessel detection capabilities by identifying their wakes, without any a priori knowledge of their positions.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1137
Author(s):  
Ondřej Holešovský ◽  
Radoslav Škoviera ◽  
Václav Hlaváč ◽  
Roman Vítek

We compare event-cameras with fast (global shutter) frame-cameras experimentally, asking: “What is the application domain, in which an event-camera surpasses a fast frame-camera?” Surprisingly, finding the answer has been difficult. Our methodology was to test event- and frame-cameras on generic computer vision tasks where event-camera advantages should manifest. We used two methods: (1) a controlled, cheap, and easily reproducible experiment (observing a marker on a rotating disk at varying speeds); (2) selecting one challenging practical ballistic experiment (observing a flying bullet having a ground truth provided by an ultra-high-speed expensive frame-camera). The experimental results include sampling/detection rates and position estimation errors as functions of illuminance and motion speed; and the minimum pixel latency of two commercial state-of-the-art event-cameras (ATIS, DVS240). Event-cameras respond more slowly to positive than to negative large and sudden contrast changes. They outperformed a frame-camera in bandwidth efficiency in all our experiments. Both camera types provide comparable position estimation accuracy. The better event-camera was limited by pixel latency when tracking small objects, resulting in motion blur effects. Sensor bandwidth limited the event-camera in object recognition. However, future generations of event-cameras might alleviate bandwidth limitations.


2021 ◽  
Vol 8 (1) ◽  
pp. 205395172110135
Author(s):  
Florian Jaton

This theoretical paper considers the morality of machine learning algorithms and systems in the light of the biases that ground their correctness. It begins by presenting biases not as a priori negative entities but as contingent external referents—often gathered in benchmarked repositories called ground-truth datasets—that define what needs to be learned and allow for performance measures. I then argue that ground-truth datasets and their concomitant practices—that fundamentally involve establishing biases to enable learning procedures—can be described by their respective morality, here defined as the more or less accounted experience of hesitation when faced with what pragmatist philosopher William James called “genuine options”—that is, choices to be made in the heat of the moment that engage different possible futures. I then stress three constitutive dimensions of this pragmatist morality, as far as ground-truthing practices are concerned: (I) the definition of the problem to be solved (problematization), (II) the identification of the data to be collected and set up (databasing), and (III) the qualification of the targets to be learned (labeling). I finally suggest that this three-dimensional conceptual space can be used to map machine learning algorithmic projects in terms of the morality of their respective and constitutive ground-truthing practices. Such techno-moral graphs may, in turn, serve as equipment for greater governance of machine learning algorithms and systems.


Author(s):  
CHENGGUANG ZHU ◽  
zhongpai Gao ◽  
Jiankang Zhao ◽  
Haihui Long ◽  
Chuanqi Liu

Abstract The relative pose estimation of a space noncooperative target is an attractive yet challenging task due to the complexity of the target background and illumination, and the lack of a priori knowledge. Unfortunately, these negative factors have a grave impact on the estimation accuracy and the robustness of filter algorithms. In response, this paper proposes a novel filter algorithm to estimate the relative pose to improve the robustness based on a stereovision system. First, to obtain a coarse relative pose, the weighted total least squares (WTLS) algorithm is adopted to estimate the relative pose based on several feature points. The resulting relative pose is fed into the subsequent filter scheme as observation quantities. Second, the classic Bayes filter is exploited to estimate the relative state except for moment-of-inertia ratios. Additionally, the one-step prediction results are used as feedback for WTLS initialization. The proposed algorithm successfully eliminates the dependency on continuous tracking of several fixed points. Finally, comparison experiments demonstrate that the proposed algorithm presents a better performance in terms of robustness and convergence time.


2018 ◽  
Vol 5 (6) ◽  
pp. e502 ◽  
Author(s):  
Barbara Spanò ◽  
Giovanni Giulietti ◽  
Valerio Pisani ◽  
Manuela Morreale ◽  
Elisa Tuzzi ◽  
...  

ObjectivesTo apply advanced diffusion MRI methods to the study of normal-appearing brain tissue in MS and examine their correlation with measures of clinical disability.MethodsA multi-compartment model of diffusion MRI called neurite orientation dispersion and density imaging (NODDI) was used to study 20 patients with relapsing-remitting MS (RRMS), 15 with secondary progressive MS (SPMS), and 20 healthy controls. Maps of NODDI were analyzed voxel-wise to assess the presence of abnormalities within the normal-appearing brain tissue and the association with disease severity. Standard diffusion tensor imaging (DTI) parameters were also computed for comparing the 2 techniques.ResultsPatients with MS showed reduced neurite density index (NDI) and increased orientation dispersion index (ODI) compared with controls in several brain areas (p < 0.05), with patients with SPMS having more widespread abnormalities. DTI indices were also sensitive to some changes. In addition, patients with SPMS showed reduced ODI in the thalamus and caudate nucleus. These abnormalities were associated with scores of disease severity (p < 0.05). The association with the MS functional composite score was higher in patients with SPMS compared with patients with RRMS.ConclusionsNODDI and DTI findings are largely overlapping. Nevertheless, NODDI helps interpret previous findings of increased anisotropy in the thalamus of patients with MS and are consistent with the degeneration of selective axon populations.


Sign in / Sign up

Export Citation Format

Share Document