scholarly journals A Recognition Algorithm of VGPO Jamming Based on Discrete Chirp-Fourier Transform

2020 ◽  
Author(s):  
Chuanzhang Wu ◽  
Baixiao Chen

Abstract We address the recognition problem of velocity gate pull-off (VGPO) jamming from the target echo signal for the velocity automatic tracking system. To this end, we resort to the discrete chirp-Fourier transform (DCFT) to jointly estimate the chirp rates and frequencies of the target and jamming signals. Firstly, the scaling characteristic of the DCFT algorithm is explored. Then we highlight the quantitative effect of the VGPO jamming signal by analyzing the jointly estimated result in each pulse. The effective effect indicates that the relationship between the estimated chirp rate and the pulse is similar to that between the frequency offset of VGPO jamming and the time when the estimated frequency is unchanged. Finally, by utilizing the analytical result and extracting the feature of the mean square to variance ratio (MSVR) of the normalized estimated chirp rate, the VGPO jamming can be recognized. Simulation results show that, for a time when the estimated frequency is unchanged, the MSVR of VGPO jamming decreases with the pulse numbers increases, and is always larger than that of a target which is steady. Comparing to other methods, the proposed method can correctly recognize the jamming signal with jamming-to-noise ratio (JNR) 5dB which shows better recognition performance, and is also effective within a shorter period.

2020 ◽  
Author(s):  
Chuanzhang Wu ◽  
Baixiao Chen

Abstract This paper addresses the recognition problem of velocity gate pull-off (VGPO) jamming from the target echo signal for the velocity-based tracking system. The discrete chirp-Fourier transform (DCFT) is studied in this paper to jointly estimate the chirp rates and frequencies of the target and jamming signals. Firstly, the scaling characteristic of the DCFT algorithm is explored. Then we focus on the quantitative effect of the VGPO jamming signal by analyzing the jointly estimated results in each pulse. The quantitative effect indicates that, as long as the estimated frequency is unchanged, the relationship between the estimated chirp rate and the pulse numbers is similar to the relationship between the frequency offset of VGPO jamming and the time. Finally, by utilizing the joint estimated results in each pulse repetition interval and calculating the mean square to variance ratio (MSVR) of the normalized estimated chirp rate, the VGPO jamming can be recognized. Simulation results show that the jamming signal and the target echo become distinguishable with the proposed feature. Comparing to the existing works, the proposed method can correctly recognize the jamming signal with lower jamming-to-noise ratio (JNR) 5dB with less data needed, which means it can work effectively in the early stage of interference implementation and shows great potential in practical applications.


2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Shoma Hattori ◽  
Shinji Nozue ◽  
Yoshiaki Ihara ◽  
Koji Takahashi

AbstractTo evaluate the expiratory sounds produced during swallowing recorded simultaneously with videofluorographic examination of swallowing (VF) using fast Fourier transform (FFT), and to examine the relationship between dysphagia and its acoustic characteristics. A total of 348 samples of expiratory sounds were collected from 61 patients with dysphagia whose expiratory sounds were recorded during VF. The VF results were evaluated by one dentist and categorized into three groups: safe group (SG), penetration group (PG), and aspiration group (AG). The duration and maximum amplitude of expiratory sounds produced were measured as the domain characteristics on the time waveform of these sounds and compared among the groups. Time window-length appropriate for FFT and acoustic discriminate values (AD values) of SG, PG, and AG were also investigated. The groups were analyzed using analysis of variance and Scheffé's multiple comparison method. The maximum amplitude of SG was significantly smaller than those of PG and AG. The mean duration in SG (2.05 s) was significantly longer than those in PG (0.84 s) and AG (0.96 s). The AD value in SG was significantly lower than those in PG and AG. AD value detects penetration or aspiration, and can be useful in screening for dysphagia.


2012 ◽  
Vol 2012 ◽  
pp. 1-13 ◽  
Author(s):  
Yufeng Lu ◽  
Alireza Kasaeifard ◽  
Erdal Oruklu ◽  
Jafar Saniie

A fractional fourier transform (FrFT) based chirplet signal decomposition (FrFT-CSD) algorithm is proposed to analyze ultrasonic signals for NDE applications. Particularly, this method is utilized to isolate dominant chirplet echoes for successive steps in signal decomposition and parameter estimation. FrFT rotates the signal with an optimal transform order. The search of optimal transform order is conducted by determining the highest kurtosis value of the signal in the transformed domain. A simulation study reveals the relationship among the kurtosis, the transform order of FrFT, and the chirp rate parameter in the simulated ultrasonic echoes. Benchmark and ultrasonic experimental data are used to evaluate the FrFT-CSD algorithm. Signal processing results show that FrFT-CSD not only reconstructs signal successfully, but also characterizes echoes and estimates echo parameters accurately. This study has a broad range of applications of importance in signal detection, estimation, and pattern recognition.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Jianyun Ni ◽  
Jing Luo ◽  
Wubin Liu

This paper proposed a novel 3D palmprint recognition algorithm by combining 3D palmprint features using D-S fusion theory. Firstly, the structured light imaging is used to acquire the 3D palmprint data. Secondly, two types of unique features, including mean curvature feature and Gaussian curvature feature, are extracted. Thirdly, the belief function of the mean curvature recognition and the Gaussian curvature recognition was assigned, respectively. Fourthly, the fusion belief function from the proposed method was determined by the Dempster-shafer (D-S) fusion theory. Finally, palmprint recognition was accomplished according to the classification criteria. A 3D palmprint database with 1000 range images from 100 individuals was established, on which extensive experiments were performed. The results show that the proposed method 3D palmprint recognition is much more robust to illumination variations and condition changes of palmprint than MCR and GCR. Meanwhile, by fusing mean curvature and Gaussian curvature feature, the experimental results are promising (the average equal error rate of 0.404%). In the future, imaging technique needs further improvement for a better recognition performance.


1991 ◽  
Vol 65 (03) ◽  
pp. 263-267 ◽  
Author(s):  
A M H P van den Besselaar ◽  
R M Bertina

SummaryIn a collaborative trial of eleven laboratories which was performed mainly within the framework of the European Community Bureau of Reference (BCR), a second reference material for thromboplastin, rabbit, plain, was calibrated against its predecessor RBT/79. This second reference material (coded CRM 149R) has a mean International Sensitivity Index (ISI) of 1.343 with a standard error of the mean of 0.035. The standard error of the ISI was determined by combination of the standard errors of the ISI of RBT/79 and the slope of the calibration line in this trial.The BCR reference material for thromboplastin, human, plain (coded BCT/099) was also included in this trial for assessment of the long-term stability of the relationship with RBT/79. The results indicated that this relationship has not changed over a period of 8 years. The interlaboratory variation of the slope of the relationship between CRM 149R and RBT/79 was significantly lower than the variation of the slope of the relationship between BCT/099 and RBT/79. In addition to the manual technique, a semi-automatic coagulometer according to Schnitger & Gross was used to determine prothrombin times with CRM 149R. The mean ISI of CRM 149R was not affected by replacement of the manual technique by this particular coagulometer.Two lyophilized plasmas were included in this trial. The mean slope of relationship between RBT/79 and CRM 149R based on the two lyophilized plasmas was the same as the corresponding slope based on fresh plasmas. Tlowever, the mean slope of relationship between RBT/79 and BCT/099 based on the two lyophilized plasmas was 4.9% higher than the mean slope based on fresh plasmas. Thus, the use of these lyophilized plasmas induced a small but significant bias in the slope of relationship between these thromboplastins of different species.


Author(s):  
Shivananda B Nayak ◽  
Dharindra Sawh ◽  
Brandon Scott ◽  
Vestra Sears ◽  
Kareshma Seebalack ◽  
...  

Purpose: i) To determine the relationship between the cardiac biomarkers ST2 and NT-proBNP with ejection fraction (EF) in heart failure (HF) patients. ii) Assess whether a superiority existed between the aforementioned cardiac markers in diagnosing the HF with reduced EF. iii) Determine the efficacy of both biomarkers in predicting a 30-day cardiovascular event and rehospitalization in patients with HF with reduced EF iv) To assess the influence of age, gender, BMI, anaemia and renal failure on the ST2 and NT-proBNP levels. Design and Methods: A prospective double-blind study was conducted to obtain data from a sample of 64 cardiology patients. A blood sample was collected to test for ST2 and NT-proBNP. An echocardiogram (to obtain EF value), electrocardiogram and questionnaire were also obtained. Results: Of the 64 patients enrolled, 59.4% of the population had an EF less than 40%. At the end of the 30- day period, 7 patients were warded, 37 were not warded, one died and 17 were non respondent. Both biomarkers were efficacious at diagnosing HF with a reduced EF. However, neither of them were efficacious in predicting 30-day rehospitalization. The mean NT-proBNP values being: not rehospitalized (2114.7486) and 30 day rehospitalization (1008.42860) and the mean ST2 values being: not rehospitalized (336.1975), and 30-day rehospitalization. (281.9657). Conclusion: Neither ST2 or NT-proBNP was efficacious in predicting the short- term prognosis in HF with reduced EF. Both however were successful at confirming the diagnosis of HF in HF patients with reduced EF.


Sensors ◽  
2020 ◽  
Vol 21 (1) ◽  
pp. 52
Author(s):  
Tianyi Zhang ◽  
Abdallah El Ali ◽  
Chen Wang ◽  
Alan Hanjalic ◽  
Pablo Cesar

Recognizing user emotions while they watch short-form videos anytime and anywhere is essential for facilitating video content customization and personalization. However, most works either classify a single emotion per video stimuli, or are restricted to static, desktop environments. To address this, we propose a correlation-based emotion recognition algorithm (CorrNet) to recognize the valence and arousal (V-A) of each instance (fine-grained segment of signals) using only wearable, physiological signals (e.g., electrodermal activity, heart rate). CorrNet takes advantage of features both inside each instance (intra-modality features) and between different instances for the same video stimuli (correlation-based features). We first test our approach on an indoor-desktop affect dataset (CASE), and thereafter on an outdoor-mobile affect dataset (MERCA) which we collected using a smart wristband and wearable eyetracker. Results show that for subject-independent binary classification (high-low), CorrNet yields promising recognition accuracies: 76.37% and 74.03% for V-A on CASE, and 70.29% and 68.15% for V-A on MERCA. Our findings show: (1) instance segment lengths between 1–4 s result in highest recognition accuracies (2) accuracies between laboratory-grade and wearable sensors are comparable, even under low sampling rates (≤64 Hz) (3) large amounts of neutral V-A labels, an artifact of continuous affect annotation, result in varied recognition performance.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Satoru Kanda ◽  
Takumi Hara ◽  
Ryosuke Fujino ◽  
Keiko Azuma ◽  
Hirotsugu Soga ◽  
...  

AbstractThis study aimed to investigate the relationship between autofluorescence (AF) signal measured with ultra-wide field imaging and visual functions in patients with cone-rod dystrophy (CORD). A retrospective chart review was performed for CORD patients. We performed the visual field test and fundus autofluorescence (FAF) measurement and visualized retinal structures with optical coherence tomography (OCT) on the same day. Using binarised FAF images, we identified a low FAF area ratio (LFAR: low FAF/30°). Relationships between age and logMAR visual acuity (VA), central retinal thickness (CRT), central choroidal thickness (CCT), mean deviation (MD) value, and LFAR were investigated. Thirty-seven eyes of 21 CORD patients (8 men and 13 women) were enrolled. The mean patient age was 49.8 years. LogMAR VA and MD were 0.52 ± 0.47 and − 17.91 ± 10.59 dB, respectively. There was a significant relationship between logMAR VA and MD (p = 0.001). LogMAR VA significantly correlated with CRT (p = 0.006) but not with other parameters. Conversely, univariate analysis suggested a significant relationship between MD and LFAR (p = 0.001). In the multivariate analysis, LFAR was significantly associated with MD (p = 0.002). In conclusion, it is useful to measure the low FAF area in patients with CORD. The AF measurement reflects the visual field deterioration but not VA in CORD.


2020 ◽  
pp. 088506662098250
Author(s):  
Chad M. Conner ◽  
William H. Perucki ◽  
Andre Gabriel ◽  
David M. O’Sullivan ◽  
Antonio B. Fernandez

Introduction: There is a paucity of data evaluating the impact of heart rate (HR) during Targeted Temperature Management (TTM) and neurologic outcomes. Current resuscitation guidelines do not specify a HR goal during TTM. We sought to determine the relationship between HR and neurologic outcomes in a single-center registry dataset. Methods: We retrospectively studied 432 consecutive patients who completed TTM (33°C) after cardiac arrest from 2008 to 2017. We evaluated the relationship between neurologic outcomes and HR during TTM. Pittsburgh Cerebral Performance Categories (CPC) at discharge were used to determine neurological recovery. Statistical analysis included chi square, Student’s t-test and Mann-Whitney U. A logistic regression model was created to evaluate the strength of contribution of selected variables on the outcome of interest. Results: Approximately 94,000 HR data points from 432 patients were retrospectively analyzed; the mean HR was 82.17 bpm over the duration of TTM. Favorable neurological outcomes were seen in 160 (37%) patients. The mean HR in the patients with a favorable outcome was lower than the mean HR of those with an unfavorable outcome (79.98 bpm vs 85.67 bpm p < 0.001). Patients with an average HR of 60-91 bpm were 2.4 times more likely to have a favorable neurological outcome compared to than HR’s < 60 or > 91 (odds ratio [OR] = 2.36, 95% confidence interval [CI] 1.61-3.46, p < 0.001). Specifically, mean HR’s in the 73-82 bpm range had the greatest rate of favorable outcomes (OR 3.56, 95% CI 1.95-6.50), p < 0.001. Administration of epinephrine, a history of diabetes mellitus and hypertension all were associated with worse neurological outcomes independent of HR. Conclusion: During TTM, mean HRs between 60-91 showed a positive association with favorable outcomes. It is unclear whether a specific HR should be targeted during TTM or if heart rates between 60-91 bpm might be a sign of less neurological damage.


Sign in / Sign up

Export Citation Format

Share Document