scholarly journals Modelling and Optimization of Photovoltaic Serpentine Type Thermal Solar Collector With Thermal Energy Storage System For Hot Water and Electricity Generation For Single Residential Building

Author(s):  
Srimanickam Baskaran ◽  
Christopher Sathiya Satchi ◽  
Saranya Amirtharajan ◽  
Metilda Manuel Swami Durai

Abstract Increasing surface temperature significantly affects the electrical performance of photovoltaic (PV) panels. A closed-loop forced circulation serpentine tube design of cooling water system is used to effectively manage the surface temperature of PV panels. A real-time experiment was first carried out with a PV panel with a cooling system at HTF flow rates of 60 kg h-1, 120 kg h-1, and 180 kg h-1. Based on the experimentation, a correlation for a nominal operating cell temperature (NOCT) and thermal efficiency for collector was developed for experimental validation of useful energy gained, cell temperature and electric power generation. The developed corrections are validated with electrical power and useful energy gained in photovoltaic serpentine thermal solar collector (PV/STSC) and fit into experimental results with a deviation of 1% and 2.5 % respectively. Further, with the help of developed correlations, a system was developed in the TRNSYS tool through which an optimization study was performed based on electric and hot water demand. The findings indicate that an optimal system with an 8 m2 PV/STSC area, a HTF flow rate of 60 kg h-1, and TES system having a volume and height of 280 l and 0.8 m could meet 91 % and 33 % of the hot water demand for Ac loads and 78 % or DC loads, respectively.

2018 ◽  
Vol 7 (3) ◽  
Author(s):  
Amiral Aziz

Pangkalan Susu Coal Fire Steam Power Plants (CFSPP) are planned to build in Tanjung Pasir Village, Langkat Regency taking sea water as cooling condenser of power plants, and through it back into the sea. To explore the possibilities of re-entry of the circulation of hot water to the intake, it is necessary to study the termal dispersion within the framework of those plans. In this study, numerical modeling to determine termal distribution pattern that comes out from CFSPP outlet. From the study it could be concluded that with the given intake inlet – discharge outfall design configuration and under the worst scenario, cooling water system of Pangkalan Susu unit 3 & 4 is safe i.e. re-circulation of warmcooling water will not happen. The Pangkalan Susu unit 3 & 4 will consume intact sea water (30.5oC). However, the Pangkalan Susu unit 1 & 2 will be influenced by the warm cooling system that may decrease its cooling system efficiency since its inlet is covered by shattered sea water (31.2oC – 32.2oC).keywords : thermal dispersion, power plant. numerical modeling


Energies ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1281 ◽  
Author(s):  
Alok Dayanand ◽  
Muhsin Aykapadathu ◽  
Nazmi Sellami ◽  
Mehdi Nazarinia

This paper presents the experimental investigation of a novel cross-compound parabolic concentrator (CCPC). For the first time, a CCPC module was designed to simultaneously work as an electricity generator and collect the thermal energy present in the module which is generated due to the incident irradiation. This CCPC module consists of two regions: an absorber surface atop the rig and a reflective region below that to reflect the irradiation onto the photovoltaic (PV) cell, coupled together to form an absorptive/reflective CCPC (AR-CCPC) module. A major issue in the use of PV cells is the decrease in electrical conversion efficiency with the increase in cell temperature. This module employs an active cooling system to decrease the PV cell temperature, optimizing the electrical performance and absorbing the heat generated within the module. This system was found to have an overall efficiency of 63%, which comprises the summation of the electrical and thermal efficiency posed by the AR-CCPC module.


A completed study of a solar hot water heating system installed in a school showed an annual average efficiency of 15%, the low efficiency largely caused by the unfavourable pattern of use in schools. Field studies, in 80 existing and 12 new houses, of a simple domestic hot water system have been initiated to ascertain the influence of the occupants on the actual performance of solar collector systems. The development of testing methods of solar collectors and solar water heating systems is being undertaken in close collaboration with the B.S.I. and the E.E.C. Solar space heating is being investigated in two experimental low energy house laboratories, one using conventional solar collectors with interseasonal heat storage and the other a heat pump with an air solar collector. Studies of the cost-effectiveness of solar collector applications to buildings in the U.K. show that they are far less cost-effective than other means of conserving energy in buildings.


Author(s):  
Jan Albers ◽  
Giovanni Nurzia ◽  
Felix Ziegler

The efficient operation of a solar cooling system strongly depends on the chiller behaviour under part-load conditions since driving energy and cooling load are never constant. For this reason the performance of a single stage, hot water driven 30 kW H2O/LiBr-absorption chiller employed in a solar cooling system with a field of 350 m2 evacuated tube collectors has been analysed under part-load conditions with both simulations and experiments. A simulation model has been developed for the whole absorption chiller (Type Yazaki WFC-10), where all internal mass and energy balances are solved. The connection to the external heat reservoirs of hot, chilled and cooling water is done by lumped and distributed UA-values for the main heat exchangers. In addition to an analytical evaporator model — which is described in detail — experimental correlations for UA-values have been used for condenser, generator and solution heat exchanger. For the absorber a basic model based on Nusselt theory has been employed. The evaporator model was developed taking into account the distribution of refrigerant on the tube bundle as well as the change in operation from a partially dry to an overflowing evaporator. A linear model is derived to calculate the wetted area. The influence of these effects on cooling capacity and COP is calculated for three different combinations of hot and cooling water temperature. The comparison to experimental data shows a good agreement in the various operational modes of the evaporator. The model is able to predict the transition from partially dry to an overflowing evaporator quite well. The present deviations in the domain with high refrigerant overflow can be attributed to the simple absorber model and the linear wetted area model. Nevertheless the results of this investigation can be used to improve control strategies for new and existing solar cooling systems.


2020 ◽  
Vol 12 (15) ◽  
pp. 6071
Author(s):  
Nikola Pokorny ◽  
Tomáš Matuška

Photovoltaic–thermal collector generates electrical and thermal energy simultaneously from the same area. In this paper performance analysis of a potentially very promising application of a glazed photovoltaic–thermal collector for domestic hot water preparation in multifamily building is presented. Solar system in multifamily building can be installed on the roof or integrated in the façade of the building. The aim of this simulation study is to show difference of thermal and electrical performance between façade and roof installation of a glazed photovoltaic-thermal collectors at three European locations. Subsequently, this study shows benefit of photovoltaic-thermal collector installation in comparison with side-by-side installation of conventional system. For the purpose of simulation study, mathematical model of glazed photovoltaic-thermal collector has been experimentally validated and implemented into TRNSYS. A solar domestic hot water system with photovoltaic–thermal collectors generates more electrical and thermal energy in comparison with a conventional system across the whole of Europe for a particular installation in a multifamily building. The specific thermal yield of the photovoltaic–thermal system ranges between 352 and 582 kWh/m2. The photovoltaic–thermal system electric yield ranges between 63 and 149 kWh/m2. The increase in electricity production by the photovoltaic–thermal system varies from 19% to 32% in comparison with a conventional side-by-side system. The increase in thermal yield differs between the façade and roof alternatives. Photovoltaic-thermal system installation on the roof has higher thermal yield than conventional system and the increase of thermal yield ranges from 37% to 53%. The increase in thermal yield of façade photovoltaic-thermal system is significantly higher in comparison with a conventional system and ranges from 71% to 81%.


2013 ◽  
Vol 6 (2) ◽  
pp. 99-114 ◽  
Author(s):  
E. J. Pieterse-Quirijns ◽  
E. J. M. Blokker ◽  
E. van der Blom ◽  
J. H. G. Vreeburg

Abstract. Existing Dutch guidelines for the design of the drinking water and hot water system of non-residential buildings are based on outdated assumptions on peak water demand or on unfounded assumptions on hot water demand. They generally overestimate peak demand values required for the design of an efficient and reliable water system. Recently, a procedure was developed based on the end-use model SIMDEUM to derive design-demand-equations for peak demand values of both cold and hot water during various time steps for several types and sizes of non-residential buildings, viz. offices, hotels and nursing homes. In this paper, the design-demand-equations are validated with measurements of cold and hot water patterns on a per second base and with surveys. The good correlation between the simulated water demand patterns and the measured patterns indicates that the basis of the design-demand-equations, the SIMDEUM simulated standardised buildings, is solid. Surveys were held to investigate whether the construction of the standardised buildings based on the dominant variable corresponds with practice. Surveys show that it is difficult to find relationships to equip the standardised buildings with users and appliances. However, the validation proves that with a proper estimation of the number of users and appliances in only the dominant functional room of the standardised buildings, SIMDEUM renders a realistic cold and hot water diurnal demand pattern. Furthermore, the new design-demand-equations based on these standardised buildings give a better prediction of the measured peak values for cold water flow than the existing guidelines. Moreover, the new design-demand-equations can predict hot water use well. In this paper it is illustrated that the new design-demand-equations lead to reliable and improved designs of building installations and water heater capacity, resulting in more hygienic and economical installations.


2012 ◽  
Vol 512-515 ◽  
pp. 2171-2174 ◽  
Author(s):  
Quan Ying Yan ◽  
Ran Huo ◽  
Li Li Jin

Physical and numerical models of the radiant ceiling cooling system were built and numerically simulated. The results showed that the lower the temperature of cooling water is, the lower surface temperature the ceiling has, and the bigger the cooling capacity is. The bigger the depth of tubes is, the higher the surface temperature and the smaller the cooling capacity. The differences are not evident. The bigger the distance of tubes is, the bigger the surface temperature is and the smaller the cooling capacity is. The diameter of tubes has a few influences on the surface temperature and the cooling capacity. Results in this paper can provide basis and guide for the design of the project, the selection of parameters and the feasibility of the system.


Author(s):  
Ru Yang ◽  
Geng-Yi Lin

A large solar hot water system can be utilized to provide driving energy for heating system, heat-driven cooling system, as well as to provide hot water. This research addresses the effects of the storage tank design parameters on the performance of a large-scale solar hot water system with a horizontal storage tank. Most literatures only considered the stratification performance of the thermal storage tank itself instead of considering the overall system performance. Also, there is lack of experimental research data available for the design purpose. Therefore, this study employs a numerical simulation technique to study the design parameters effect of a horizontal thermal storage tank on the performance of a large-scale solar hot water system. In this study, the ANSYS-CFX program is employed to calculate the flow and temperature distributions inside horizontal thermal storage tank. Then the inlets and outlets of the tank are combined with the TRNSYS program to simulate the entire system performance under the weather of three representative cities of Taiwan, (Taipei, Taichung and, Kaohsiung). The results of the present study indicate that the vertical stratification baffles in the tank have important effects on system performance improvement. Quantitative increase of solar fraction of the total load is obtained. The comparison with the system with vertical storage tank is provided. The results of the present study can provide important reference for the large solar hot water system design in improving system efficiency.