Potable reuse of wastewater effluent through an integrated soil aquifer treatment (SAT) - membrane system

2003 ◽  
Vol 3 (3) ◽  
pp. 25-33
Author(s):  
C. Jarusutthirak ◽  
G. Amy ◽  
D. Foss

Soil aquifer treatment (SAT) has been shown to provide significant reductions of wastewater effluent organic matter (EfOM). While SAT can renovate wastewater effluent to levels commensurate with potable reuse, SAT represents only a single treatment barrier. Membrane filtration has been demonstrated to be an alternative treatment process for wastewater reclamation. However, the performance of membrane filtration is significantly constrained by membrane fouling, reducing membrane productivity in terms of flux decline. Soil aquifer treatment (SAT) is used as a primary barrier in the reclamation system to remove a complex suite of chemical and biological contaminants in wastewater. This study of membrane filtration of SAT-source waters is intended to determine the benefits of the SAT system in terms of membrane fouling reduction with membrane filtration providing a secondary barrier. Membrane treatment of SAT-recovered water provides a multiple barrier exhibiting additional organic matter removal. Moreover, the SAT system also provides for storage of reclaimed water. The synergy between SAT and membrane treatment has led to the concept of an integrated SAT-membrane system for potable reuse.

Membranes ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 369
Author(s):  
Shengji Xia ◽  
Xinran Zhang ◽  
Yuanchen Zhao ◽  
Fibor J. Tan ◽  
Pan Li ◽  
...  

The membrane separation process is being widely used in water treatment. It is very important to control membrane fouling in the process of water treatment. This study was conducted to evaluate the efficiency of a pre-oxidation-coagulation flat ceramic membrane filtration process using different oxidant types and dosages in water treatment and membrane fouling control. The results showed that under suitable concentration conditions, the effect on membrane fouling control of a NaClO pre-oxidation combined with a coagulation/ceramic membrane system was better than that of an O3 system. The oxidation process changed the structure of pollutants, reduced the pollution load and enhanced the coagulation process in a pre-oxidation-coagulation system as well. The influence of the oxidant on the filtration system was related to its oxidizability and other characteristics. NaClO and O3 performed more efficiently than KMnO4. NaClO was more conducive to the removal of DOC, and O3 was more conducive to the removal of UV254.


2004 ◽  
Vol 4 (5-6) ◽  
pp. 215-222 ◽  
Author(s):  
A.R. Costa ◽  
M.N. de Pinho

Membrane fouling by natural organic matter (NOM), namely by humic substances (HS), is a major problem in water treatment for drinking water production using membrane processes. Membrane fouling is dependent on membrane morphology like pore size and on water characteristics namely NOM nature. This work addresses the evaluation of the efficiency of ultrafiltration (UF) and Coagulation/Flocculation/UF performance in terms of permeation fluxes and HS removal, of the water from Tagus River (Valada). The operation of coagulation with chitosan was evaluated as a pretreatment for minimization of membrane fouling. UF experiments were carried out in flat cells of 13.2×10−4 m2 of membrane surface area and at transmembrane pressures from 1 to 4 bar. Five cellulose acetate membranes were laboratory made to cover a wide range of molecular weight cut-off (MWCO): 2,300, 11,000, 28,000, 60,000 and 75,000 Da. Severe fouling is observed for the membranes with the highest cut-off. In the permeation experiments of raw water, coagulation prior to membrane filtration led to a significant improvement of the permeation performance of the membranes with the highest MWCO due to the particles and colloidal matter removal.


2018 ◽  
Vol 19 (3) ◽  
pp. 855-863 ◽  
Author(s):  
T. Miyoshi ◽  
Y. Takahashi ◽  
T. Suzuki ◽  
R. Nitisoravut ◽  
C. Polprasert

Abstract This study investigated the performance of a hybrid membrane filtration system to produce industrial water from highly-colored surface water. The system consists of a membrane filtration process with appropriate pretreatments, including coagulation, pre-chlorination, and anion exchange (IE) process. The results of the pilot-scale experiments revealed that the hybrid system can produce treated water with color of around 5 Pt-Co, dissolved manganese concentration of no more than 0.05 mg/L, and a silt density index (SDI) of no more than 5 when sufficient coagulant and sodium hypochlorite were dosed. Although the IE process effectively reduced the color of the water, a moderate increase in the color of the IE effluent was observed when there was a significant increase in the color of the raw water. This resulted in a severe membrane fouling, which was likely to be attributed to the excess production of inorganic sludge associated with the increased coagulant dosage required to achieve sufficient reduction of color. Such severe membrane fouling can be controlled by optimising the backwashing and relaxation frequencies during the membrane filtration. These results indicate that the hybrid system proposed is a suitable technology for treating highly-colored surface water.


2017 ◽  
Vol 30 (1) ◽  
pp. 1-10 ◽  
Author(s):  
Thi Thu Nga Vu ◽  
Manon Montaner ◽  
Christelle Guigui

Wastewater effluents can be treated by an integrated membrane system combining membrane bioreactor (MBR) and reverse osmosis (RO) for effective removal of micropollutants in the field of high-quality water reuse. However, discharging the RO concentrate waste stream directly into the natural environment could lead to serious problems due to the toxic components contained in the concentrates (micropollutants, salts, organic matter). A possible solution could be the recirculation of RO concentrate waste to the MBR. However, such an operation should be studied in detail since the recirculation of non-biodegradable organic matter or high concentrations of salts and micropollutants could directly or indirectly contribute to MBR membrane fouling and modification of the biodegradation activity. In this context, the work reported here focused on the recirculation of such concentrates in an MBR, paying specific attention to MBR membrane fouling. Lab-scale experiments were performed on a continuous MBR-RO treatment line with RO concentrate recirculation. The main goal was to determine the recovery of the RO unit and of the global process that maintained good process performance in terms of biodegradation and MBR fouling. The results demonstrate that the impact of the toxic flow on activated sludge depends on the recovery of the RO step but the same trends were observed regardless of the organic matter and salt contents of the concentrates: the concentration of proteins increased slightly. Size-exclusion high performance liquid chromatography (HPLC-SEC) was employed to study the effects of RO concentrate on the production of protein-like soluble microbial products (SMPs) and demonstrated a significant peak of protein-like substances corresponding to 10-100 kDa and 100-1 000 kDa molecules in the supernatant. Thus a significant increase in the propensity for sludge fouling was observed, which could be attributed to the increased quantity of protein-like substances. Finally, the effect of the concentrate on sludge activity was studied and no significant effect was observed on biodegradation, indicating that the return of the concentrate to the MBR could be a good alternative.


2011 ◽  
Vol 64 (8) ◽  
pp. 1685-1691 ◽  
Author(s):  
T. Li ◽  
B. Z. Dong ◽  
Z. Liu ◽  
W. H. Chu

Algogenic organic matter (AOM) was extracted from blue-green algae (cyanobacteria) and its characteristic was determined by various methods including high-pressure size-exclusion chromatography (HP-SEC), hydrophobic and hydrophilic fractionation, molecular weight (MW) fractionation and fluorescence excitation emission matrix (EEM). The results revealed that AOM was hydrophilic fractionation predominantly, accounting for 78%. The specific ultraviolet absorbance of AOM was 1.1 L/(mg m) only. The analysis for MW distribution demonstrated that organic matter greater than 30,000 MW accounted for over 40% and was composed of mostly neutral hydrophilic compound. EEM analyses revealed that protein-like and humic-substances existed in AOM. A test for membrane filtration exhibited that AOM could make ultrafiltration membrane substantial flux decline, which can be attributed to membrane pore clog caused by neutral hydrophilic compound with larger MW.


2008 ◽  
Vol 58 (8) ◽  
pp. 1535-1539 ◽  
Author(s):  
L. Sabina ◽  
B. Kus ◽  
H.-K. Shon ◽  
J. Kandasamy

Organic characterisation in rainwater was investigated in terms of dissolved organic carbon (DOC) and molecular weight distribution (MWD) after powdered activated carbon (PAC) adsorption. PAC adsorption was used as pretreatment to membrane filtration to reduce membrane fouling. The MW of organic matter in rainwater used in this study was in the range of 43,000 Da to 30 Da. Each peak of organic matter consisted of biopolymers (polysaccharides and proteins), humic and fulvic acids, building blocks, low MW acids (hydrolysates of humic substances), low MW neutrals and amphiphilics. Rainwater contained the majority of hydrophilic compounds up to 72%. PAC adsorption removed 33% of total DOC. The removal efficiencies of the hydrophobic and hydrophilic fractions after PAC adsorption were 50% and 27%, respectively. PAC adsorption was found to preferentially remove the hydrophobic fraction. The majority of the smaller MW of 1,100 Da, 820 Da, 550 Da, 90 Da and 30 Da was removed after PAC adsorption. The MFI values decreased from 1,436 s/L2 to 147 s/L2 after PAC adsorption. It was concluded that PAC adsorption can be used as a pretreatment to membrane filtration with rainwater.


Membranes ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 845
Author(s):  
Ziyan Wang ◽  
Keqiang Liu ◽  
Ya Gao ◽  
Guanhua Li ◽  
Zhenyu Li ◽  
...  

Insufficient removal of microplastics (MPs) and nanoplastics (NPs) may exert negative effects on the environment and human health during wastewater reclamation. The fertilizer-driven forward osmosis (FDFO) is an emerging potential technology to generate high-quality water for irrigation of hydroponic systems. In this study, the removal of MPs/NPs by the FDFO process together with their impact on FDFO membrane fouling was investigated, due to FDFO’s low molecular weight cut-off and energy requirement by using fertilizer as draw solution. Plastic particles with two different sizes (100 nm and 1 μm) and extracellular polymers released by real wastewater bacteria were utilized as model compounds for FDFO performance comparison. Results show that FDFO membrane system could generate high-quality irrigation water with only fertilizer, completely removing extracellular polymers, MPs and NPs from wastewater. It was found that the MPs and NPs themselves do not cause a significant membrane fouling. Moreover, it could help to reduce the membrane fouling caused by extracellular substances. That is probably because MPs and NPs helped to form a loose and porous fouling layer. Therefore, the FDFO process could be a long-term stable (low fouling) process for the reclamation of wastewater with high-quality requirements.


Sign in / Sign up

Export Citation Format

Share Document