Performance Analysis of the Rotating Biological Contactor Process Based on Particle Fraction and Improvement of Final Effluent Quality

1991 ◽  
Vol 23 (7-9) ◽  
pp. 1457-1466 ◽  
Author(s):  
Kazuhiro Tanaka ◽  
Minoru Tada ◽  
Mitsuo Ito ◽  
Noritugu Shimizu

Biofilm processes are, in general, suitable for small-scale wastewater treatment plants. However, final effluent qualities of biofilm processes are not as good as those of activated sludge processes due to fine particles remaining in the effluents. To improve the effluent qualities of the Rotating Biological Contactors (RBC) process, the behavior of fine particles through the process and the removal of fine particles with solids-liquid separation methods, rapid filtration and coagulation-filtration, were investigated using the particle fraction method. The results are as follows:–An increase of the hydraulic retention time (HRT) in the RBC reactor reduced the amount of fine particles and increased the amount of coarse suspended solids of 44 µm or more in diameter, which are easily removed by clarification. Thus, the final effluent qualities were improved by the increase of HRT.–Suspended solids in effluent from the RBC process at the standard loading are so fine that improvement of the quality is not expected by only lowering the overflow rate of a final clarifier. In contrast, rapid filtration or a coagulation-filtration process is effective. The supended solid concentration and transparency of the effluent from the final clarifier was improved by a factor of two to four, and then BOD of the final effluent was removed by 40-85%.

2004 ◽  
Vol 49 (5-6) ◽  
pp. 39-46 ◽  
Author(s):  
K.-I. Gil ◽  
E. Choi

The recycle water from sludge processing in municipal wastewater treatment plants causes many serious problems in the efficiency and stability of the mainstream process. Thus, the design approach for recycle water is an important part of any biological nutrient removal system design when a retrofit technology is required for upgrading an existing plant. Moreover, the application of nitrogen removal from recycle water using the nitritation process has recently increased due to economic reasons associated with an effective carbon allocation as well as the minimization of aeration costs. However, for the actual application of recycle water nitritation, it has not been fully examined whether or not additional volume would be required in an existing plant. In this paper, the addition of recycle water nitritation to an existing plant was evaluated based on a volume analysis and estimation of final effluent quality. It was expected that using the reserve volume of the aeration tank in existing plants, recycle water nitritation could be applied to a plant without any enlargement. With the addition of recycle water nitritation, it was estimated that the final effluent quality would be improved and stabilized, especially in the winter season.


1987 ◽  
Vol 19 (3-4) ◽  
pp. 483-494 ◽  
Author(s):  
K. Tanaka ◽  
A. Oshima ◽  
B. E. Rittmann

Rotating Biological Contactors (RBC) have only recently been introduced in Japan as a means of providing secondary treatment to domestic wastewaters. The use of RBCs appears to be particularly attractive for small communities because of their low energy demand and reduced O-M requirements. To evaluate and demonstrate the feasibility of the process as an alternative to conventional secondary treatment, a field study was performed at three municipal facilities in Japan. A single, fundamental model of biofilm kinetics was shown to be capable of accurately predicting soluble BOD5 removals throughout the RBC. Model and field study results indicated that effluent soluble BOD5 should be 3 to 7 mg/l for conventional loads. Approximately 30 percent of the RBC effluent solids were found to be fine particles having a settling velocity of less than 10 to 15 m/day and which exerted 60 to 70 percent of the final effluent total BOD5. Therefore, special attention must he given to solids-liquid separation of the RBC effluent to ensure that the final effluent is of acceptable quality. Several solids-liquid separation methods, including direct screening of RBC effluent, were shown to be feasible in upgrading the effluent quality.


2020 ◽  
Vol 82 (7) ◽  
pp. 1380-1392
Author(s):  
Marcos von Sperling ◽  
Emmanuelle Machado Maia Nogueira Lima ◽  
Mirene Augusta de Andrade Moraes

Abstract A scientific basis is given to the traditional method of inferring effluent quality based on visualization of samples in transparent flasks. A scale of 1–6, with different printed grey intensities, is placed behind transparent PET bottles containing the sample, and gives an indication of the range of turbidity in the sample (1 is the most transparent and can only be visualized if the effluent is well clarified; in the other spectrum, 6 is the darkest and indicates highly turbid effluents). Turbidity has been correlated with total suspended solids (TSS), particulate biochemical oxygen demand (BOD) and particulate chemical oxygen demand (COD) based on thousands of monitored data collected in the effluent from seven different treatment processes in Brazil: upflow anaerobic sludge blanket (UASB) reactor, trickling filters, activated sludge, horizontal wetland, vertical wetland, polishing ponds and coarse filter after pond. The method is simple and instantaneous, can be used in virtually all places and in every visit of the operator to the remote treatment plant, allows recording of the image in smartphones, does not use any equipment, chemicals or energy, and has been showed to represent well the effluent quality of existing treatment plants. This essay is complementary and does not substitute specific traditional sampling and analysis, but allows easy inference of deterioration of effluent quality.


1990 ◽  
Vol 22 (7-8) ◽  
pp. 35-43
Author(s):  
K. D. Tracy ◽  
S. N. Hong

The anaerobic selector of the A/0™ process offers many advantages over conventional activated sludge processes with respect to process performance and operational stability. This high-rate, single-sludge process has been successfully demonstrated in full-scale operations for biological phosphorus removal and total nitrogen control in addition to BOD and TSS removal. This process can be easily utilized in upgrading existing treatment plants to meet stringent discharge limitations and to provide capacity expansion. Upgrades of two full-scale installations are described and performance data from the two facilities are presented.


1990 ◽  
Vol 22 (3-4) ◽  
pp. 139-144 ◽  
Author(s):  
S. Iwai ◽  
Y. Oshino ◽  
T. Tsukada

Although the ratio of sewer systems to population in Japan has been improving in recent years, the construction of sewer systems in small communities such as farming or fishing villages, etc. had lagged behind that of urban areas. However, construction of small-scale sewer systems in farming and fishing villages has been actively carried out in recent years. This report explains the history of the promotion of small-scale sewer systems, why submerged filter beds are being employed in many cases, and introduces the design, operation and maintenance of representative waste-water treatment plants in farming and fishing villages which incorporate de-nitrogen and dephosphorization.


1990 ◽  
Vol 22 (3-4) ◽  
pp. 65-72 ◽  
Author(s):  
H.-H. Schierup ◽  
H. Brix

Since 1983 approximately 150 full-scale emergent hydrophyte based wastewater treatment plants (reed beds) have been constructed in Denmark to serve small wastewater producers. The development of purification performance for 21 plants representing different soil types, vegetation, and hydraulic loading rates has been recorded. Cleaning efficiencies were typically in the range of 60-80% reduction for BOD, 25-50% reduction for total nitrogen, and 20-40% reduction for total phosphorus. The mean effluent BOD, total nitrogen and total phosphorus concentrations of the reed beds were 19 ± 10, 22 ± 9 and 6.7 ± 3.2 mg/l (mean ± SD), respectively. Thus, the general Danish effluent standards of 8 mg/l for N and 1.5 mg/l for P for sewage plants greater than 5,000 PE cannot be met by the present realised design of EHTS. The main problem observed in most systems is a poor development of horizontal hydraulic conductivity in the soil which results in surface run-off. Since the political demands for effluent quality will be more strict in the future, it is important to improve the performance of small decentral sewage treatment plants. On the basis of experiences from different types of macrophyte based and conventional low-technology wastewater treatment systems, a multi-stage system is suggested, consisting of sedimentation and sand filtration facilities followed by basins planted with emergent and submergent species of macrophytes and algal ponds.


1990 ◽  
Vol 22 (3-4) ◽  
pp. 49-56
Author(s):  
E. D. Smith ◽  
R. J. Scholze

This paper presents a review of collected experience of one of the U.S. Corps of Engineers research laboratories in the area of small systems for wastewater treatment. Findings and experiences are presented for the use of package plants such as rotating biological contactors (RBCs), and remote site waste treatment at military installations and recreation areas.


1987 ◽  
Vol 19 (12) ◽  
pp. 265-271
Author(s):  
P. R. Thomas ◽  
H. O. Phelps

The investigation was based on two facultative stabilization ponds initially designed to operate in parallel, and now receive wastewater in excess of their capacities from a fast expanding housing estate in the Caribbean Island of Trinidad. Because of the deterioration of the effluent quality relative to acceptable standards, an attempt was made to upgrade the ponds using water hyacinths at the early stages. However, from the results, it was clear that the introduction of water hyacinths in the test pond did not lead to any substantial improvement in the effluent because of the high loading on the pond. Therefore the ponds were modified to operate in series with surface aerators installed in the first pond. Initially, the effluent quality was monitored in terms of total suspended solids, volatile suspended solids, biochemical oxygen demand, faecal coliform bacteria, pH and dissolved oxygen with aeration in the first pond and no aquatic plants in the second pond. Although there was a significant improvement in the effluent quality, the values remained above the standards. As a result, water hyacinths were introduced in the second pond and the effluent quality monitored together with aeration in the first pond. The effluent quality improved with total suspended solids and biochemical oxygen demand values both as low as 10 mg/l in certain months, but additional treatment was needed to reduce faecal conforms.


1996 ◽  
Vol 33 (1) ◽  
pp. 81-87
Author(s):  
L. Van Vooren ◽  
P. Willems ◽  
J. P. Ottoy ◽  
G. C. Vansteenkiste ◽  
W. Verstraete

The use of an automatic on-line titration unit for monitoring the effluent quality of wastewater plants is presented. Buffer capacity curves of different effluent types were studied and validation results are presented for both domestic and industrial full-scale wastewater treatment plants. Ammonium and ortho-phosphate monitoring of the effluent were established by using a simple titration device, connected to a data-interpretation unit. The use of this sensor as the activator of an effluent quality proportional sampler is discussed.


1993 ◽  
Vol 28 (10) ◽  
pp. 33-41
Author(s):  
Jes la Cour Jansen ◽  
Bodil Mose Pedersen ◽  
Erik Moldt

Influent and effluent data from about 120 small wastewater treatment plants (100 - 2000 PE) have been collected and processed. Seven different types of plants are represented. The effluent quality and the treatment efficiency have been evaluated. The most common type of plant is mechanical/biological treatment plants. Some of them are nitrifying and some are also extended for chemical precipitation of phosphorus. Constructed wetlands and biological sandfilters are also represented among the small wastewater treatment plants.


Sign in / Sign up

Export Citation Format

Share Document