Field investigations on reactive settling in an intermittent aeration sequencing batch reactor activated sludge process

2000 ◽  
Vol 41 (1) ◽  
pp. 127-135 ◽  
Author(s):  
A.A. Kazmi ◽  
H. Furumai

The overall reactions during settling in an intermittent aeration SBR activated sludge process have been studied on a full scale. Several field investigations were conducted during settling in different seasons. Nitrate, MLSS, phosphate and TOC profiles were obtained at specified depths. Mass balances of nitrogen were made in order to evaluate the effect of different MLSS and seasonal conditions on nitrogen removal during settling. Total nitrogen reduction of more than 30% was achieved during settling by maintaining high MLSS in order of 3000 mg/L. Residual DO plays an important role in causing delay of denitrification for lower MLSS sludge concentration. Phosphorus release was observed in the bottom of the reactor and its occurrence was well coincident with the pH decrease. Denitrification rates and their temperature dependency were determined. Temperature coefficient θ was found to be 1.083 (valid in the range of 17–27°C). Mass transfer limitation during batch sludge settling was discussed. It was found out from batch tests with and without mixing, that denitrification rate was reduced by 40% under mass transfer limiting conditions.

1996 ◽  
Vol 34 (1-2) ◽  
pp. 111-118 ◽  
Author(s):  
Kousei Sasaki ◽  
Yasuji Yamamoto ◽  
Kazushi Tsumura ◽  
Sachiko Ouchi ◽  
Yutaka Mori

We have developed a new intermittently aerated anaerobic-aerobic activated sludge process. This process employs 2 reactors connected in series, and is capable of controlling the duration of aerobic, anoxic and anaerobic conditions in both reactors by utilizing the ORP bending point, which corresponds to the termination of denitrification. One cycle of aeration and agitation takes approximately 120 minutes. In the 1st reactor, nitrification and phosphorus uptake occur in the aeration period, followed by denitrification and phosphorus release in the agitation period. In the 2nd reactor, nitrification and phosphorus uptake are conducted during aeration, and denitrification and weak phosphorus uptake during agitation. A one-year pilot plant experiment using sewage (22 m3/day) showed stable and high removal ratios of 98% for BOD, 92% for T-N, and 85% for T-P under conditions of HRT 20 hours and water temperature 9∼33°C.


2004 ◽  
Vol 50 (10) ◽  
pp. 203-212 ◽  
Author(s):  
D. Gapes ◽  
B.-M. Wilén ◽  
J. Keller

An experimental study was conducted to describe mass transfer impacts within nitrifying aggregates sourced from sequencing batch reactor (SBR) activated sludge systems. Flocculent and granular sludge with high nitrification activity was obtained in two laboratory SBR systems, supplied with a synthetic, ammonium-based feed. The flocculent biomass was fractionated using a sieving procedure, in order to obtain biomass fractions with different particle size distributions. The oxygen uptake rate (OUR) response to changes in dissolved oxygen concentration was measured under highly controlled conditions in a titrimetric and off-gas analysis (TOGA) sensor, and the results used to assess mass transfer effects. As the average particle size of the biomass increased, mass transfer limitations were found to increase significantly. Empirically fitted, apparent KS,O2 values were demonstrated to be highly dependent on particle size, and reflect the mass transfer limitations occurring in the aggregates within a given system. Such parameters thus have little to do with the actual biokinetic parameter from which they are derived. The results obtained from the TOGA sensor study were consistent with those obtained from a microelectrode study on the same nitrifying granules. Together, these studies add considerable weight to the conclusion that consideration of external and internal mass transfer limitations is vital to the accurate description of activated sludge treatment processes, particularly those with a high oxygen uptake rate.


1993 ◽  
Vol 28 (10) ◽  
pp. 267-274 ◽  
Author(s):  
M. Imura ◽  
E. Suzuki ◽  
T. Kitao ◽  
S. Iwai

In order to apply a sequencing batch reactor activated sludge process to small scale treatment facilities, various experiments were conducted by manufacturing an experimental apparatus made of a factory-produced FRP cylinder transverse tank (Ø 2,500mm). Results of the verification test conducted for one year by leading the wastewater discharged from apartment houses into the experimental apparatus were as follows. Excellent performance was achieved without any addition of carbon source, irrespective of the organic compound concentration and the temperature of raw wastewater. Organic substances, nitrogen and phosphorus were removed simultaneously. Due to the automated operation format, stable performance was obtained with only periodic maintenance. Though water depth of the experimental plant was shallow, effective sedimentation of activated sludge was continued during the experimental period. Regarding the aerobic and anaerobic process, nitrification and denitrification occurred smoothly.


1993 ◽  
Vol 28 (11-12) ◽  
pp. 513-521 ◽  
Author(s):  
Kousei Sasaki ◽  
Yasuji Yamamoto ◽  
Kazushi Tsumura ◽  
Shigeru Hatsumata ◽  
Masahiro Tatewaki

The 2-tank intermittent aeration method is an anaerobic-aerobic activated sludge process of time-sharing type in which 2 complete mixing reaction tanks are connected in series, and aeration and agitation are periodically repeated in each tank. We have developed a new control system for the process which can secure anaerobic, anoxic and aerobic conditions through a combination of DO and ORP-Bending-point (corresponding to termination of denitrification) emergence time control. In the 1st tank, nitrification and phosphorus uptake occur in the aeration period, followed by denitrification and phosphorus release in the agitation. The 2nd tank performs nitrification and phosphorus uptake in the aeration and denitrification in the agitation. One cycle of aeration and agitation is approximately 2 hours. This control system was applied to the test plant (influent flow rate: 225 I/day) for two months under the conditions of HRT 16 hours and temperature 20 ±2 °C. We achieved stable and high removal ratios: TOC 94.9 %, T-N 89.4 %, and T-P 95.5 %. We also investigated the mechanisms of nitrogen and phosphorus removal and their material balance.


1998 ◽  
Vol 34 (2) ◽  
pp. 1-14 ◽  
Author(s):  
YUZURU KIMOCHI ◽  
YUHEI INAMORI ◽  
NOBORU FURUYA ◽  
TOICHI EBISUNO ◽  
MASATOSHI MATSUMURA

1985 ◽  
Vol 17 (11-12) ◽  
pp. 315-316
Author(s):  
Mitsumasa Okada ◽  
Ryuichi Sudo

Abstract–Phosphorus removal by biological means in continuous-flow aerobic/ anaerobic activated sludge processes is now in a stage of full-scale operations. The similar aerobic/anaerobic treatment is also found in biological processes for nitrogen removal by nitrification followed by denitrification. These processes are successfully applied not only to continuous-flow system but also to sequencing batch reactor (SBR) activated sludge processes, whereas little attempts have been reported on phosphorus removal in SBR activated sludge processes. It is most probable that both phosphorus and nitrogen in addition to organic matter can be removed by the SBR activated sludge processes if aerobic and anaerobic treatments were properly incorporated into a cycle of batch operation. Laboratory scale experiments on aerobic/anaerobic operations of the SBR processes were conducted aiming at simultaneous removal of phosphorus, nitrogen, and organic matter without any addition of chemicals. SBR of 5 1 in working volume was fed with synthetic wastewater in which TOC = 120-200 mg/l, BOD = 200-400 mg/l, total phosphorus = 6-12 mg/1 and total nitrogen = 36-60 mg/1. The following sequence of operations were conducted in a batch cycle; 1) mixing and inflow of wastewater, 2) aeration and mixing, 3) mixing, 4) aeration and mixing, 5) settling and 6) decanting. It was secured from continuous monitoring of dissolved oxygen concentration in the mixed liquor that both anaerobic (stages 1 and 3) and aerobic (stages 2 and 4) treatments were repeated twice in a cycle. In some operations, stages 3 and 4 were omitted for comparison, i.e. anaerobic and aerobic treatments were conducted only once per cycle. The volume of mixed liquor before the inflow of wastewater at the beginning of a cycle (low level) ranged from 33 % to 50 % of that during full volume stages from 2 to 5 (high level). In stage 6, the supernatant was discharged down to the low level and followed by the next cycle of operation. The length of time for a cycle of operation was β h or 9.5 h. Among various types of operations tried, the following sequence was the best in the quality of effluent; 1) 2 h for mixing and inflow, 2) 3 h for aeration and mixing, 3) 3 h for mixing, 4) 20 min for aeration and mixing, 5) 1 h for settling, and 6) 10 min for decanting in a cycle of 9.5 h if influent BOD, total phosphorus and total nitrogen concentrations were 400 mg/1, 12 mg/1 and 60 mg/1, respectively, and BOD loading was 0.68 kg/cu m/d. Total phosphorus and nitrogen concentrations in the effluent were 1.2 mg/1 and 8.0 mg/1, respectively. Similar results were obtained in operations where anaerobic and aerobic treatments were repeated twice in a cycle. In operations where effluent quality was satisfactory, release of phosphorus from the sludge was observed in stage 1. The reactor concentration of filterable total phosphorus (FTP) increased rapidly and its maximum value observed at the end of the stage was ca. 50 mg/1. Phosphorus uptake under aerobic condition (stage 2) decreased FTP to the level of effluent FTP. The luxury uptake of phosphorus by the sludge was noted, i.e. phosphorus content in the sludge ranged from 2.0 % to 4.0 %(w/w). The release of phosphorus from the sludge and subsequent luxury uptake were not significant during stages 3 to 4, hence, further removal of phosphorus was not remarkable. Nitrate nitrogen concentration increased during stage 2 by nitrification. Denitrification was noted both in stages 1 and 3. In stage 1, filterable total organic carbon (FTOC) increased by the inflow of wastewater. It should be, therefore, utilized for denitrification as hydrogen donor. FTOC decreased rapidly after the initiation of aeration in stage 2 and little FTOC remained after the latter half of stage 2. Intracellular organic substances of the sludge, therefore, were regarded to be utilized for denitrification without any addition of chemicals at stage 3. In the best operation, from 50% to 70% out of total nitrogen inflow was removed by denitrification. Effluent BOD was less than 10 mg/l. Although further investigations would be required to determine optimum scheduling in a cycle such as the combination of anaerobic and aerobic periods, the ratio between low and high levels in the reactor, the length of a cycle, and etc. for a given wastewater, the SBR activated sludge process would be a promising wastewater treatment process for simultaneous removal of phosphorus, nitrogen and organiC matter by a single reactor. In spite of complicated operational sequence, full scale automatic operations of SBR activated sludge process would be possible economically even in small-scale plants by using recently advanced microcomputer technology.


2011 ◽  
Vol 46 (1) ◽  
pp. 9-16 ◽  
Author(s):  
Oytun Hanhan ◽  
Güçlü Insel ◽  
Nevin Ozgur Yagci ◽  
Nazik Artan ◽  
Derin Orhon

2008 ◽  
Vol 58 (1) ◽  
pp. 239-245 ◽  
Author(s):  
M. Naso ◽  
A. Chiavola ◽  
E. Rolle

This paper provides new insights on the application of the ozonation process for the reduction of the activated sludge production in a sequencing batch reactor (SBR). The study was performed in two identical lab-scale SBRs plant, one for experimental activities (Exp SBR) and one used as control (Control SBR), both fed with domestic sewage. A fraction of the activated sludge collected from the Exp SBR at the end of the aerobic react phase was periodically subjected to ozonation for 30 minutes at three different specific dosages (0.05, 0.07 and 0.37 g O3/gSS) and then recirculated before the beginning of the following cycle. Recirculation of the ozonated sludge to the Exp SBR did not appreciably affect the efficiency of the biological nitrogen and carbon removal processes. Nonetheless, an improvement of the denitrification kinetic was observed. Mixed liquor volatile and suspended solids (MLSS and MLVSS, respectively) concentrations in the reactor decreased significantly with time for long term application of the ozonation treatment. Kinetic batch tests on unstressed sludge taken from Control SBR indicated that the different oxidant dosages (0.05, 0.07 and 0.37 g O3/gSS) and durations of the ozonation process (10, 20 and 30 minutes) used remarkably affected chemical oxygen demand (COD) and organic nitrogen fractioning. In particular, soluble and biodegradable fractions seemed to be higher at lower dosage and longer contact time.


Sign in / Sign up

Export Citation Format

Share Document