Treatment of wine distillery wastewater by high rate anaerobic digestion

2007 ◽  
Vol 56 (2) ◽  
pp. 9-16 ◽  
Author(s):  
X.L. Melamane ◽  
R. Tandlich ◽  
J.E. Burgess

Wine distillery wastewaters (WDW) are acidic and have a high content of potential organic pollutants. This causes high chemical oxygen demand (COD) values. Polyphenols constitute a significant portion of this COD, and limit the efficiency of biological treatment of WDWs. WDW starting parameters were as follows: pH 3.83, 4,185 mg/l soluble COD (CODs) and 674.6 mg/l of phenols. During operation, amendments of CaCO3 and K2HPO4, individually or in combination, were required for buffering the digester. Volatile fatty acid concentrations were <300 mg/l throughout the study, indicating degradation of organic acids present. Mean CODs removal efficiency for the 130 day study was 87%, while the mean polyphenol, removal efficiency was 63%. Addition of 50 mg/l Fe3 +  between days 86 and 92 increased the removal efficiencies of CODs to 97% and of polyphenols to 65%. Addition of Co3 +  improved removal efficiencies to 97% for CODs and 92% for polyphenols. Optimization of anaerobic treatment was achieved at 30% WDW feed strength. Removal efficiencies of 92% and 84% were recorded at increased feed strength from days 108 to 130. High removal efficiencies of CODs and polyphenols after day 82 were attributed to the addition of macronutrients and micronutrients that caused pH stability and thus stimulated microbial activity.

RSC Advances ◽  
2017 ◽  
Vol 7 (38) ◽  
pp. 23714-23726 ◽  
Author(s):  
Xin Zhou ◽  
Zeqian Zhang ◽  
Yaxin Li

Biokinetic models of high-strength coking wastewater with a high chemical oxygen demand (COD) was efficiently treated by a novel pilot-scale four-stage biofilm anaerobic–anoxic–oxic–oxic (FB-A2/O2) system.


2004 ◽  
Vol 49 (5-6) ◽  
pp. 281-288 ◽  
Author(s):  
S.J. Kim ◽  
P.Y. Yang

A two-stage entrapped mixed microbial cell (2SEMMC) process which separates nitrification and denitrification phases by the installation of the anoxic and oxic EMMC reactors packed with EMMC carriers was operated with 6, 4, 3, and 2 hours of hydraulic retention time (HRT) using simulated domestic wastewater. The activated sludge was immobilized using cellulose acetate for the EMMC carriers. Similar soluble chemical oxygen demand (SCOD) removal efficiencies of 90-97% were observed for all HRTs (SCOD loading rate of 0.84-2.30 g/L/d) applied. In order to achieve more than 80 % of TN removal efficiency, the HRT should be maintained higher than 4 hours (less than 0.24 g/L/d of TN loading rate). Denitrification was a rate-limiting step which controlled overall TN removal efficiency at TN loading rate of 0.15-0.31 g/L/d although nitrification efficiencies achieved 97-99 %. The effluent TSS of less than 25 mg/L in the 2SEMMC process was maintained at the SCOD loading rate of less than 1.23 g/L/d with back-washing intervals of 5 and 10 days in the anoxic and oxic EMMC reactors, respectively. The minimum HRT of 4 hours is required for high removal efficiencies of organics (average 95.6 %) and nitrogen (average 80.5 %) in the 2SEMMC process with 3 times of recirculation ratio.


2019 ◽  
Vol 80 (4) ◽  
pp. 707-716 ◽  
Author(s):  
Min Sang ◽  
Miansong Huang ◽  
Wei Zhang ◽  
Wu Che ◽  
Huichao Sun

Abstract Bioretention is an effective technology for urban stormwater management, but the nutrient removal in conventional bioretention systems is highly variable. Thus, a pilot bioretention column experiment was performed to evaluate the nutrient control of systems with commercial activated carbon and river sediment-derived biochar. Significant chemical oxygen demand (COD) and total phosphorus (TP) leaching were found with the addition of activated carbon and biochar, but total nitrogen (TN) leaching was significantly improved when activated carbon was used as the medium. During a semi-synthetic runoff experiment, the bioretention systems containing two types of fluvial biochar showed relatively better COD and TN control (average mass removal efficiencies and cumulative removal efficiencies) than commercial activated carbon. However, the average TP mass removal efficiency with commercial activated carbon (95% ± 3%) was significantly higher than biochar (48% ± 20% and 56 ± 14%). The addition of biochar in the media increased the nitrogen removal efficiency, and the addition of activated carbon significantly increased the phosphorous removal efficiency. Therefore, both biochar and activated carbon are effective materials for bioretention, and fluvial biochar provides an alternative approach to comprehensively utilize river sediment.


2003 ◽  
Vol 38 (2) ◽  
pp. 243-265 ◽  
Author(s):  
Catherine N. Mulligan ◽  
Bernard F. Gibbs

Abstract Biological treatment of wastewater has been employed successfully for many types of industries. Aerobic processes have been used extensively. Production of large amounts of sludge is the main problem and methods such as biofilters and membrane bioreactors are being developed to combat this phenomenon. Anaerobic waste treatment has undergone significant developments and is now reliable with low retention times. The UASB, the original high rate anaerobic reactor, is now becoming less popular than the EGSB reactor. New developments such as the Annamox process are highly promising for nitrogen removal. For metal removal, processes such as biosorption and biosurfactants combined with ultrafiltration membranes are under development. Biosurfactants have also shown promise as dispersing agents for oil spills. If space is available, wetlands can be used to reduce biological oxygen demand (BOD), total suspended solids (TSS), nutrients and heavy metals. These innovative processes are described in this paper in terms of applications, the stage of development, and future research needs particular to Canada.


2018 ◽  
Vol 78 (9) ◽  
pp. 1879-1892 ◽  
Author(s):  
Md Khalekuzzaman ◽  
Muhammed Alamgir ◽  
Mehedi Hasan ◽  
Md Nahid Hasan

Abstract In this research, a hybrid anaerobic baffled reactor (HABR) configuration was proposed consisting of a front sedimentation chamber and four regular baffled chambers followed by two floated filter media chambers for the treatment of domestic wastewater. Performance comparison of uninsulated and insulated HABRs was carried out operating at warm temperature (18.6–37.6 °C) under variable HRTs (30 h and 20 h). The study suggests that almost similar chemical oxygen demand (91% vs 88%), total suspended solids (90% vs 95%), turbidity (98% vs 97%), and volatile suspended solids (90% vs 93%) removal efficiencies were obtained for uninsulated and insulated HABRs. Higher removal of total nitrogen (TN) of 41%, NH4+-N of 44%, and NO3−-N of 91% were achieved by the insulated HABR compared to TN of 37%, NH4+-N of 36%, and NO3−-N of 84% by the uninsulated HABR, whereas lower PO43− removal efficiency of 17% was found in the insulated HABR compared to 24% in the uninsulated HABR. This indicated insulation increased nitrogen removal efficiencies by 4% for TN, 8% for NH4+-N and 7% for NO3−-N, but decreased PO43−removal efficiency by 7%.


Author(s):  
Amin Mojiri ◽  
John L. Zhou ◽  
Harsha Ratnaweera ◽  
Akiyoshi Ohashi ◽  
Noriatsu Ozaki ◽  
...  

Abstract Landfill leachate is characterised by high chemical and biological oxygen demand and generally consists of undesirable substances such as organic and inorganic contaminants. Landfill leachate may differ depending on the content and age of landfill contents, the degradation procedure, climate and hydrological conditions. We aimed to explain the characteristics of landfill leachate and define the practicality of using different techniques for treating landfill leachate. Different treatments comprising biological methods (e.g. bioreactors, bioremediation and phytoremediation) and physicochemical approaches (e.g. advanced oxidation processes, adsorption, coagulation/flocculation and membrane filtration) were investigated in this study. Membrane bioreactors and integrated biological techniques, including integrated anaerobic ammonium oxidation and nitrification/denitrification processes, have demonstrated high performance in ammonia and nitrogen elimination, with a removal effectiveness of more than 90%. Moreover, improved elimination efficiency for suspended solids and turbidity has been achieved by coagulation/flocculation techniques. In addition, improved elimination of metals can be attained by combining different treatment techniques, with a removal effectiveness of 40–100%. Furthermore, combined treatment techniques for treating landfill leachate, owing to its high chemical oxygen demand and concentrations of ammonia and low biodegradability, have been reported with good performance. However, further study is necessary to enhance treatment methods to achieve maximum removal efficiency.


Author(s):  
Junwon Park ◽  
Changsoo Kim ◽  
Youngmin Hong ◽  
Wonseok Lee ◽  
Hyenmi Chung ◽  
...  

In this study, we analyzed 27 pharmaceuticals in liquid and solid phase samples collected from the unit processes of four different sewage treatment plants (STPs) to evaluate their distribution and behavior of the pharmaceuticals. The examination of the relative distributions of various categories of pharmaceuticals in the influent showed that non-steroidal anti-inflammatory drugs (NSAIDs) were the most dominant. While the relative distribution of antibiotics in the influent was not high (i.e., 3%–5%), it increased to 14%–30% in the effluent. In the four STPs, the mass load of the target pharmaceuticals was reduced by 88%–95% mainly in the biological treatment process, whereas the ratio of pharmaceuticals in waste sludge to those in the influent (w/w) was only 2%. In all the STPs, the removal efficiencies for the stimulant caffeine, NSAIDs (acetaminophen, naproxen, and acetylsalicylic acid), and the antibiotic cefradine were high; they were removed mainly by biological processes. Certain compounds, such as the NSAID ketoprofen, contrast agent iopromide, lipid regulator gemfibrozil, and antibiotic sulfamethoxazole, showed varying removal efficiencies depending on the contribution of biodegradation and sludge sorption. In addition, a quantitative meta-analysis was performed to compare the pharmaceutical removal efficiencies of the biological treatment processes in the four STPs, which were a membrane bioreactor (MBR) process, sequencing batch reactor (SBR) process, anaerobic–anoxic–oxic (A2O) process, and moving-bed biofilm reactor (MBBR) process. Among the biological processes, the removal efficiency was in the order of MBR > SBR > A2O > MBBR. Among the tertiary treatment processes investigated, powdered activated carbon showed the highest removal efficiency of 18%–63% for gemfibrozil, ibuprofen, ketoprofen, atenolol, cimetidine, and trimethoprim.


2012 ◽  
Vol 65 (4) ◽  
pp. 713-720 ◽  
Author(s):  
Ying-Hua Li ◽  
Hai-Bo Li ◽  
Jing Pan ◽  
Xin Wang ◽  
Tie-Heng Sun

This study was to investigate domestic treatment efficiency of a subsurface wastewater infiltration (SWI) system over time. The performances of a young SWI system (in Shenyang University, China, fully operated for one year) and a mature SWI system (in Shenyang Normal University, China, fully operated for seven years) under the same operation mode were contrasted through field-scale experiments for one year. The performance assessment for these systems is based on physical and chemical parameters collected. The removal efficiencies within the young system were relatively high if compared with the mature one: for biochemical oxygen demand (BOD), chemical oxygen demand (COD), suspended solids (SS), ammonia nitrogen (NH3-N) and total phosphorus (TP) were 95.0, 89.1, 98.1, 87.6 and 98.4%, respectively. However, the removal efficiencies decreased over time. The mean removal efficiencies for the mature SWI system were as follows: BOD (89.6%), COD (87.2%), SS (82.6%), NH3-N (69.1%) and TP (74.4%). The results indicate that the mature SWI system successfully removed traditional pollutants such as BOD from domestic wastewater. However, the nutrient reduction efficiencies (including NH3-N and TP) decreased after seven years of operation of the mature SWI system. Meanwhile, the SWI system did not decrease the receiving surface water quality.


2013 ◽  
Vol 67 (3) ◽  
pp. 587-593 ◽  
Author(s):  
L. Yerushalmi ◽  
M. Alimahmoodi ◽  
C. N. Mulligan

Simultaneous removal of carbon, nitrogen and phosphorus was examined along with reduced generation of biological sludge during the treatment of synthetic wastewater and hog waste by the BioCAST technology. This new multi-environment wastewater treatment technology contains both suspended and immobilized microorganisms, and benefits from the presence of aerobic, microaerophilic, anoxic and anaerobic conditions for the biological treatment of wastewater. The influent concentrations during the treatment of synthetic wastewater were 1,300–4,000 mg chemical oxygen demand (COD)/L, 42–115 mg total nitrogen (TN)/L, and 19–40 mg total phosphorus (TP)/L. The removal efficiencies reached 98.9, 98.3 and 94.1%, respectively, for carbon, TN and TP during 225 days of operation. The removal efficiencies of carbon and nitrogen showed a minimal dependence on the nitrogen-to-phosphorus (N/P) ratio, while the phosphorus removal efficiency showed a remarkable dependence on this parameter, increasing from 45 to 94.1% upon the increase of N/P ratio from 3 to 4.5. The increase of TN loading rate had a minimal impact on COD removal rate which remained around 1.7 kg/m3 d, while it contributed to increased TP removal efficiency. The treatment of hog waste with influent COD, TN and TP concentrations of 960–2,400, 143–235 and 25–57 mg/L, respectively, produced removal efficiencies up to 89.2, 69.2 and 47.6% for the three contaminants, despite the inhibitory effects of this waste towards biological activity. The treatment system produced low biomass yields with average values of 3.7 and 8.2% during the treatment of synthetic wastewater and hog waste, respectively.


Sign in / Sign up

Export Citation Format

Share Document