Comparison of Enamel and Dentin Shear Bond Strengths of Current Dental Bonding Adhesives From Three Bond Generations

2013 ◽  
Vol 38 (6) ◽  
pp. E237-E245 ◽  
Author(s):  
MR Meharry ◽  
SM Moazzami ◽  
Y Li

SUMMARY Objective: Durability is still a major challenge in adhesive dentistry. One of the biggest areas of development has been to simplify the bonding process by using all-in-one adhesives. The aim of this study was to compare the shear bond strength (SBS) to dentin and enamel of nine dental bonding agents (DBAs) from three generations after simulated aging. Methods and Materials: For this study, 108 sound extracted human molars were randomly assigned to nine groups (n=12). The sample teeth were mounted in self-cure acrylic resin sectioned to provide paired enamel and dentin samples. All samples were polished with 240 and 600-grit silicon carbide sandpaper and randomly grouped according to the product and substrates (enamel or dentin). Herculite Ultra resin composite cylinders were bonded on each test surface, stored in 100% humidity at 37°C for 24 hours, and then thermocyled for 1,000 cycles at 5°C and 55°C. SBS testing was performed using an Ultratester at a crosshead speed of 0.5 mm/min. Statistical analysis included two-factor analysis of variance, one-sample Wilcoxon and Kruskal-Wallis tests, and the Scheffe post hoc test at an alpha level of 0.05 using SAS version 9.2. Results: Significant differences in SBS were observed between the sixth- and seventh-generation DBAs (p=0.002) but not between the sixth- and fourth-generation DBAs. Scheffe post hoc tests for the sixth-generation DBAs showed that some DBAs yielded significantly higher enamel SBS than others, but not as much as dentin SBS. As for the seventh-generation DBAs, similar post hoc tests showed significant variations in SBS between substrates (enamel and dentin) and DBAs tested. Significant main effects were also found for the different substrates for the fourth-generation (F[1,96]=10.532; p=0.003) and seventh-generation (F[1,96]=22.254; p<0.001) DBAs, but not for the sixth-generation DBAs (F[1,96]=1.895, p=0.172). The SBS was higher on dentin than enamel for the fourth- and seventh-generation DBAs. Conclusion: As expected, fourth- and sixth-generation DBAs generally showed stronger SBS values than the seventh-generation all-in-one DBAs. The new sixth-generation DBA OptiBond XTR (Kerr) showed strong SBS values to both substrates and performed well in comparison to the other DBAs tested.

2022 ◽  
Vol 10 (1) ◽  
pp. 13
Author(s):  
Tomas Vilde ◽  
Cameron A. Stewart ◽  
Yoav Finer

Despite their popularity, resin composite restorations fail earlier and at higher rates than comparable amalgam restorations. One of the reasons for these rates of failure are the properties of current dental bonding agents. Modern bonding agents are vulnerable to gradual chemical and mechanical degradation from a number of avenues such as daily use in chewing, catalytic hydrolysis facilitated by salivary or bacterial enzymes, and thermal fluctuations. These stressors have been found to work synergistically, all contributing to the deterioration and eventual failure of the hybrid layer. Due to the expense and difficulty in conducting in vivo experiments, in vitro protocols meant to accurately simulate the oral environment’s stressors are important in the development of bonding agents and materials that are more resistant to these processes of degradation. This narrative review serves to summarize the currently employed methods of aging dental materials and critically appraise them in the context of our knowledge of the oral environment’s parameters.


2015 ◽  
Vol 40 (5) ◽  
pp. 480-491 ◽  
Author(s):  
HM El-Damanhoury ◽  
M Gaintantzopoulou

SUMMARY The aim of this study was to compare five all-in-one bonding agents with respect to microleakage, microtensile bond strength (μTBS), degree of conversion (DC) and the impact of cavity configuration. The materials tested were Adper Easy Bond, Clearfil S3 Bond, iBond, Optibond All-in-One, Xeno IV, and Adper Single Bond Plus as a control. The DC of each adhesive was measured on the surfaces of dentin discs (n=5) by attenuated total reflectance Fourier transform infrared spectroscopy. One hundred and forty-four extracted human molars were randomly divided and assigned to one of the five tested adhesives and the control group. The μTBS to dentin was measured on flat occlusal dentin with and without thermocycling and to the gingival floor dentin of class II cavities (n=8). All specimens were restored with Filtek Z250 resin composite. Class II samples were immersed in a 5% methylene blue dye solution for 24 hours, and microleakage was examined under a stereomicroscope. Micromorphological analysis of demineralized/deproteinized specimens was done using scanning electron microscopy. The DC and microleakage data were statistically analyzed by one-way analysis of variance (ANOVA) and μTBS data by two-way ANOVA followed by a Bonferroni multiple comparison post hoc test (α=0.05) and Weibull-distribution survival analysis. The relation between different variables and μTBS and microleakage was tested by the Pearson correlation coefficient and regression statistics. A moderate direct relation between DC and μTBS durability was found for all the adhesives tested. Significant wide variations exist among the results obtained for single-bottle adhesives tested regarding their μTBS and microleakage. Some of the all-in-one materials tested have shown significantly inferior results under a high C-factor or after aging. The use of these materials should be carefully considered.


2013 ◽  
Vol 14 (4) ◽  
pp. 622-628
Author(s):  
Walaa Ahmed ◽  
Wafa El-Badrawy ◽  
Gajanan Kulkarni ◽  
Anuradha Prakki ◽  
Omar El-Mowafy

ABSTRACT Aim This study investigated the effect of different fiber inserts (glass and polyethylene), bonding agents, and resin composites on the gingival margin microleakage of class V composite restorations. Materials and methods Sixty premolars were sterilized and mounted in acrylic resin bases. Class V cavities were prepared buccally and lingually, 1 mm below the cementoenamel junction, comprising 12 groups (n = 10). In the experimental groups fiber inserts were cut and placed at the gingival seat, while the control groups had no inserts. Combinations of two composite materials, Filtek-Z250 and Filtek-LS (3M-ESPE), and four bonding agents, Clearfil SE bond (Kuraray) (C), Scotch Bond Multipurpose (3M-ESPE) (SB), Prime and Bond NT (Dentsply) (PB), and Filtek-LS (3M-ESPE) (LS) were used. Restorations were incrementally inserted and polymerized for 40s. Specimens were then stored in distilled water for 7 days and thermocycled for 500 cycles. Teeth surfaces were sealed with nail polish except for 1 mm around restoration margins and immersed in 2% red procion dye. Teeth were then sectioned buccolingually and dye penetration was assessed with five-point scale. Data were statistically-analyzed by Kruskal-Wallis, ANOVA and Tukey's tests (α = 5%). Results Mean microleakage scores varied from 0.40 (Groups C, C with polyethylene, LS, LS with polyethylene) to 1.50 (SB). Conclusion Different bonding agents led to differences in microleakage scores where C and LS showed significantly lower microleakage than PB. SB had highest mean microleakage score, however, incorporation of fibers resulted in significant reduction in microleakage. Clinical significance Class V resin composite restorations bonded with a total-etch adhesive had a significant reduction in mean microleakage scores when glass or polyethylene fibers were placed at the gingival cavo-surface margin. In contrast, for two self-etch adhesive systems, the incorporation of fibers had no significant effect on mean microleakage scores. How to cite this article Ahmed W, El-Badrawy W, Kulkarni G, Prakki A, El-Mowafy O. Gingival Microleakage of Class V Composite Restorations with Fiber Inserts. J Contemp Dent Pract 2013;14(4):622-628.


2019 ◽  
Vol 3 (Supplement_1) ◽  
Author(s):  
Velarie Ansu ◽  
Stephanie Dickinson ◽  
Alyce Fly

Abstract Objectives To determine which digit and hand have the highest and lowest skin carotenoid scores, to compare inter-and-intra-hand variability of digits, and to determine if results are consistent with another subject. Methods Two subjects’ first(F1), second(F2), third(F3) and fifth(F5) digits on both hands were measured for skin carotenoids with a Veggie Meter, for 3 times on each of 18 days over a 37-day period. Data were subjected to ANOVA in a factorial treatment design to determine main effects for hand (2 levels), digits (4), and days (18) along with interactions. Differences between digits were determined by Tukey's post hoc test. Results There were significant hand x digit, hand x day, digit x day, and hand x digit x day interactions and significant simple main effects for hand, digit, and day (all P < 0.001). Mean square errors were 143.67 and 195.62 for subject A and B, respectively, which were smaller than mean squares for all main effects and interactions. The mean scores ± SD for F1, F2, F3, and F5 digits for the right vs left hands for subject A were F1:357.13 ± 45.97 vs 363.74 ± 46.94, F2:403.17 ± 44.77 vs. 353.20 ± 44.13, F3:406.76 ± 43.10 vs. 357.11 ± 45.13, and F5:374.95 ± 53.00 vs. 377.90 ± 47.38. For subject B, the mean scores ± SD for digits for the right vs left hands were F1:294.72 ± 61.63 vs 280.71 ± 52.48, F2:285.85 ± 66.92 vs 252.67 ± 67.56, F3:268.56 ± 57.03 vs 283.22 ± 45.87, and F5:288.18 ± 34.46 vs 307.54 ± 40.04. The digits on the right hand of both subjects had higher carotenoid scores than those on the left hands, even though subjects had different dominant hands. Subject A had higher skin carotenoid scores on the F3 and F2 digits for the right hand and F5 on the left hand. Subject B had higher skin carotenoid scores on F5 (right) and F1 (left) digits. Conclusions The variability due to hand, digit, and day were all greater than that of the 3 replicates within the digit-day for both volunteers. This indicates that data were not completely random across the readings when remeasuring the same finger. Different fingers displayed higher carotenoid scores for each volunteer. There is a need to conduct a larger study with more subjects and a range of skin tones to determine whether the reliability of measurements among digits of both hands is similar across the population. Funding Sources Indiana University.


2021 ◽  
Vol 9 (1) ◽  
pp. 8
Author(s):  
Murtadha AlAli ◽  
Nikolaos Silikas ◽  
Julian Satterthwaite

Objective: To evaluate and compare the surface roughness and gloss of a DMA-free composite and Bis-GMA-free composite with a DMA-based composite before and after toothbrushing simulation. Materials and Methods: Fifteen dimensionally standardised composite specimens of three nano-hybrid resin composites (Tetric EvoCeram, Admira Fusion, and Venus Diamond) were used. Five specimens from each composite were polished and then subjected to a toothbrushing simulator. Surface roughness (Ra) and gloss were measured before toothbrushing and after 5000, 10,000, 15,000, and 20,000 toothbrushing cycles. The data was analysed using 5 × 3 ANOVA to assess surface roughness and gloss values and pairwise comparisons in the form of Tukey post hoc tests were performed to interpret main effects. Results: For all tested materials, surface roughness increased, and gloss decreased after toothbrushing abrasion. Surface roughness (Ra) values ranged from 0.14 to 0.22 μm at baseline and increased to between 0.41 and 0.49 μm after 20,000 toothbrushing cycles. Gloss values ranged between 31.9 and 50.6 GU at baseline and between 5.1 and 19.5 GU after 20,000 toothbrushing cycles. The lowest initial Ra value was detected in Venus Diamond and the highest initial gloss value was detected in Tetric EvoCeram. Conclusions: Simulated toothbrushing abrasion led to an increase in surface roughness and a decrease in gloss for all tested materials. Venus Diamond had the smoothest surface and Tetric EvoCeram had the glossiest surface after polishing and following 20,000 cycles of toothbrushing abrasion. Admira Fusion demonstrated the roughest surface and had the lowest gloss values before and after toothbrushing abrasion.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Ahmed Mohammed Hassan ◽  
Ahmed Ali Goda ◽  
Kusai Baroudi

Objective. The aim of this study was to evaluate the effect of different disinfectant agents on bond strength of two types of resin composite materials.Methods. A total of 80 sound posterior teeth were used. They were divided into four groups(n=20)according to the dentin surface pretreatment (no treatment, chlorhexidine gluconate 2%, sodium hypochlorite 4%, and EDTA 19%). Each group was divided into two subgroups according to the type of adhesive (prime and bond 2.1 and Adper easy one). Each subgroup was further divided into two subgroups according to the type of resin composite (TPH spectrum and Tetric EvoCeram). Shear bond strength between dentin and resin composite was measured using Universal Testing Machine. Data collected were statistically analyzed byt-test and one-way ANOVA followed by Tukey’spost hoctest.Results. It was found that dentin treated with EDTA recorded the highest shear bond strength values followed by sodium hypochlorite and then chlorhexidine groups while the control group showed the lowest shear bond strength.Conclusions. The surface treatment of dentin before bonding application has a great effect on shear bond strength between resin composite and dentin surface.


2011 ◽  
Vol 36 (5) ◽  
pp. 492-501 ◽  
Author(s):  
B Stawarczyk ◽  
R Hartmann ◽  
L Hartmann ◽  
M Roos ◽  
M Özcan ◽  
...  

SUMMARY This study tested the impact of Gluma Desensitizer on the shear bond strength (SBS) of two conventional (RelyX ARC, Panavia 21) and two self-adhesive (RelyX Unicem, G-Cem) resin luting cements after water storage and thermocycling. Human third molars (N=880) were embedded in acrylic resin. The buccal dentin was exposed. Teeth were randomly divided into four main groups, and the following cements were adhered: 1) RelyX ARC, 2) Panavia 21, 3) RelyX Unicem, and 4) G-Cem. In half of the teeth in each group, dentin was treated with Gluma Desensitizer. In the conventional cement groups, the corresponding etchant and adhesive systems were applied. SBS of the cements was tested after 1 hour (initial); at 1, 4, 9, 16, and 25 days of water storage; and at 1, 4, 9, 16, and 25 days of thermocycling. SBS data were analyzed by one-way analysis of variance (ANOVA); this was followed by the post hoc Scheffé test and a t-test. Overall, the highest mean SBS (MPa) was obtained by RelyX ARC (ranging from 14.6 ± 3.9 to 17.6 ± 5.2) and the lowest by Panavia 21 in combination with Gluma Desensitizer (ranging from 0.0 to 2.9 ± 1.0). All tested groups with and without desensitizer showed no significant decrease after aging conditions compared with baseline values (p&gt;0.05). Only the Panavia 21/Gluma Desensitizer combination showed a significant decrease after 4 days of thermocyling compared with initial values and 1 day thermocycling. Self-adhesive cements with Gluma Desensitizer showed increased SBS after aging conditions (ranging from 7.4 ± 1.4 to 15.2 ± 3) compared with groups without desensitizer (ranging from 2.6 ± 1.2 to 8.8 ± 2.9). No cohesive failures in dentin were observed in any of the test groups. Although self-adhesive cements with and without desensitizer presented mainly adhesive failures after water storage (95.8%) and thermocyling (100%), conventional cement (RelyX ARC) showed mainly mixed failures (90.8% and 89.2%, after water storage and thermocyling, respectively). Application of the Gluma Desensitizer to dentin before cementation had a positive effect on the SBS of self-adhesive cements.


Author(s):  
Amin Khaleghi ◽  
Amin Archin ◽  
Mojtaba Azarian Borujeni

Introduction: This study aimed to evaluate the antibacterial and antifungal effect of Ag and zinc oxide nanoparticles to complete denture acrylic resin. Materials & Methods: In this experimental laboratory study, 144 samples were evaluated. The powder of acrylic resin (PMMA Ivoclar Vivadent, Lichenstein SR Triplex Hot) was mixed homogeneously in the ultrasonic apparatus with Ag (purity: 99.99%, size: 20nm, spherical) and ZnO (purity: 99%, size: 10-30 nm, nearly spherical) particles with mass fraction 0.5, 1 ,2 and 5. The microorganisms of this study were Candida albicans and Streptococcus mutans. The growth rate of microorganisms was measured by spectrophotometer based on turbidity and readings at 600 nm. Data were analyzed by ANOVA and Tukey post hoc tests. The significance level was set at 0.05. Results: Increasing Ag and ZnO nanoparticles to acrylic resin reduced the growth of Candida Albicans and Streptococcus Mutans. Even the concentration of 0.5% significantly reduced the growth of microorganisms. Complete growth inhibition was in the concentration of 5% after 24 and 48 hours. Conclusion: Increasing the Ag and ZnO nanoparticles to acrylic resin reduced the growth of microorganisms.


2005 ◽  
Vol 100 (2) ◽  
pp. 488-492 ◽  
Author(s):  
Neala Ambrosi-Randić ◽  
Alessandra Pokrajac-Bulian ◽  
Vladimir Takšić

320 Croatian female students ( M = 20.4 yr.) were recruited to examine the validity and reliability of figural scales using different numbers of stimuli (3, 5, 7, and 9) and different serial presentation (serial and nonserial order). A two-way analysis of variance (4 numbers × 2 orders of stimuli) was performed on ratings of current self-size and ideal size as dependent variables. Analysis indicated a significant main effect of number of stimuli. This, together with post hoc tests indicated that ratings were significantly different for a scale of three figures from scales of more figures, which in turn did not differ among themselves. Main effects of order of stimuli, as well as the interaction, were not significant. The results support the hypothesis that the optimal number of figures on a scale is seven plus (or minus) two.


2015 ◽  
Vol 132 (32) ◽  
pp. n/a-n/a ◽  
Author(s):  
Xiaoxia Wang ◽  
Beili Pang ◽  
Qianqian Zhu ◽  
Jianhua Yu ◽  
Hongzhou Dong ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document